Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yaniv Mayer has a total of 119 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hybrid Funnel Technique Reduces Marginal Bone Loss Versus Conventional Drilling: A 3‐Year, Prospective, Non‐randomized, Controlled Clinical Trial

    by Luigi Canullo, Yaniv Mayer, Federica Mattalia, Iole D'URso, Filiberto Mastrangelo, Vito Carlo Alberto Caponio

    Purpose: This study aimed to compare marginal bone loss (MBL) associated with Hybrid Funnel Technique (HFT) and conventional drill osteotomy for implant site preparation when bioactive implants are used, testing the null hypothesis that no significant differences occur at 1‐ and 3 years. Materials and Methods: This prospective non‐randomized controlled clinical trial included patients undergoing implant rehabilitation with bioactive‐surface implants. Implants were placed using either conventional subtractive drilling (control group) or HFT (test group), which combines selective cortical preparation with medullary osteocompaction. The primary outcome was radiographic MBL at 3‐year follow‐up. Secondary outcomes included bleeding on probing (BoP) and plaque index (PI). Statistical analyses were performed at implant level, and linear mixed‐effects models were used to account for clustering within patients and adjust for potential confounders. Results: A total of 87 implants in 43 patients were analyzed (42 control, 45 HFT). At 1‐year follow‐up, the test group reported significantly lower MBL (0.33 ± 0.43 mm vs. mean = 0.78 ± 0.82 mm; Mann–Whitney p ‐ value = 0.006). At 3 years, MBL was significantly higher in the conventional site preparation group compared with the HFT group (1.34 ± 0.79 mm vs. 0.46 ± 0.69 mm; p < 0.001). In multivariate mixed‐effects analysis, the implant site preparation technique was the only variable independently associated with MBL at 3 years ( β = −1.10 mm, 95% CI = −1.675 to −0.527, p < 0.001), while insertion torque and other baseline variables showed no significant association. In addition, the HFT group demonstrated significantly lower BoP and PI scores, indicating more favorable peri‐implant soft tissue conditions. Conclusions: Despite the use of identical bioactive‐surface implants, implant site preparation technique significantly influenced peri‐implant bone remodeling. HFT demonstrated superior preservation of marginal bone over 3 years, suggesting that reduction of cortical compression during osteotomy provides a biological advantage. Implant site preparation remains a key determinant of long‐term peri‐implant bone stability.

  • Open Access

    Dimensional Stability of Printed Dental Model: Stability over Time at Different Storage Temperatures

    by Yaniv Skvirsky, Tahel Oguen Alon, Mohammad Shehada, Yaniv Mayer, Zvi Gutmacher

    Background and Objectives: Dental models are essential for diagnosis and prosthetic treatment planning and have traditionally been fabricated from gypsum. With the growing adoption of digital workflows, 3D-printed dental models are increasingly used; however, concerns remain regarding their dimensional stability over time. This study evaluated the temporal dimensional changes of gypsum and 3D-printed dental models under different storage conditions and assessed the uniformity of these changes across the models. Methods: A fully dentate maxillary typodont was scanned to create a reference model. Sixteen gypsum casts (Type IV dental stone) and 48 3D-printed models from three materials were fabricated. Models were stored at either 4 °C or room temperature and rescanned at predefined intervals over 28 days. Dimensional accuracy was analyzed using 3D inspection software (Geomagic Control X 2022.1.0), with trueness measured by root mean square deviation and precision by standard deviation across the full arch and five predefined regions. Statistical analysis was performed using a Bayesian hierarchical linear model, with significance set at pd > 97.5%. Results: Printed models demonstrated significantly higher precision than gypsum models at baseline and day 28 under both storage conditions, with no significant differences among printed materials. In terms of trueness, selected printed groups showed lower deviations than gypsum at baseline, while one material exhibited the best performance at day 28. Gypsum models remained relatively stable over time, whereas printed models showed time-dependent, region-specific dimensional changes, primarily in posterior regions, with maximum deviations of up to 0.026 mm. Conclusions: 3D-printed dental models exhibit limited but nonuniform dimensional changes over time, while gypsum models remain comparatively stable. Localized distortions, particularly in posterior regions, should be considered when printed models are used for precise prosthetic applications.


  • Open Access

    Implant Failure Rate in Transcrestal and Lateral Window Sinus Augmentations: A Descriptive Retrospective Cohort Study

    by Eran Gabay, Yuval Shafran, Tarek Mtanis, Eli E. Machtei, Ofir Ginesin, Hadar Zigdon-Giladi, Yaniv Mayer

    Objectives: This study aimed to describe implant survival rates and associated risk factors in patients treated with two sinus augmentation techniques—Lateral Window (LW) and Transcrestal (TC)—at a single center. Methods: A retrospective cohort analysis was performed using medical records of patients who underwent maxillary sinus augmentation and subsequent dental implant placement between 2015 and 2019 at the Rambam Healthcare Center. Data on demographic variables, surgical approach, graft materials, implant characteristics, and clinical outcomes were collected from electronic medical records. Results: A total of 135 patients met the inclusion criteria, contributing 144 TC procedures (with 144 implants) and 46 LW procedures (90 implants) to the final analysis. The overall implant failure rate was 7.7%, with a significantly higher failure rate for TC (11.11%) compared to LW (2.22%). Procedure type was a significant predictor of implant survival (OR 1.62); however, as residual bone height (RBH) data were unavailable, confounding by indication cannot be excluded and this finding should be interpreted with caution. Implant length demonstrated a significant influence on outcomes (OR 1.28 per mm increase); shorter implants (8 mm) exhibited lower survival rates (81.3%) compared to 10 mm implants (92.3%). Smoking status was identified as a negative predictor of implant survival (OR 0.23). Schneiderian membrane ruptures occurred in nine cases, seven of which were LW procedures. Smoking was the only factor affecting graft survival (OR 0.29). Conclusions: In this retrospective cohort, implant survival rates were higher in the LW group than in the TC group; however, given that individual residual bone height data were unavailable and case assignment, although governed by standardized departmental criteria, was not randomized, the possibility of confounding by indication cannot be excluded. Smoking and shorter implants were significant risk factors for implant failure. Smoking was also associated with graft failure.


  • Open Access

    Large Language Models and Retrieval‐Augmented Platforms for the Diagnosis and Management of Periodontal Diseases: A Blinded Expert‐Rated Comparative Study of 11 Systems

    by Yaniv Mayer, Bertha Demetriou, Giulio Rasperini, Eran Gabay, Rok Gašperšič, Darko Božić, Javier Calatrava, Ofir Ginesin, Hadar Zigdon Giladi, Ricardo Faria Almeida

    Aim: To compare retrieval‐augmented systems with general‐purpose large language models (LLMs) on standardised periodontal clinical vignettes. Materials and Methods: Eleven AI systems were evaluated: nine general‐purpose LLMs, one general‐purpose retrieval‐augmented platform (Perplexity) and one medical‐domain retrieval‐augmented platform (OpenEvidence). Each responded to 30 synthetic vignettes covering acute, chronic and complex periodontal scenarios. Six blinded periodontists scored responses on a 5‐point Likert scale for accuracy, safety, freedom from hallucinations and completeness in a randomised block design. Friedman and Conover–Iman tests with Holm correction were applied; mixed‐effects and ordinal models served as sensitivity analyses. Results: At least one parameter scored dangerous (≤ 2) in 3.3%–46.7% of responses across platforms, despite mean composite scores (3.28–4.86) exceeding the rubric midpoint of 3.0. Between‐model differences were significant ( p < 0.001), with a small‐to‐medium overall effect (Kendall's W = 0.17) and large within‐category effects ( W up to 0.82). Perplexity, OpenEvidence and Claude 4.7 Opus formed a top tier. Conclusion: Retrieval‐augmented systems rated highest, but this advantage was confounded with response length. The dangerous‐response spread argues against undifferentiated use. These tools should assist, not replace, specialist judgement.

  • Open Access

    Large Language Models and Retrieval-Augmented Platforms for Dental Implant Complications: A Blinded, Expert-Rated Benchmarking Study

    by Yaniv Mayer, Luigi Canullo, Marton Kivovics, Hadar Zigdon Giladi, Eran Gabay, Ofir Ginesin


  • Open Access

    Methodological Evaluation of Micro-CT Analytical Parameters for Quantifying Bone Loss in a Murine Maxillary Peri-Implantitis Model

    by Ofir Ginesin, Shiran Barsheshet-Karif, Yaniv Mayer, Eran Gabay, Yotam Bar-On, Hadar Zigdon-Giladi, Zvi Gutmacher

    Background: Peri-implantitis is a prevalent inflammatory condition leading to progressive bone loss around dental implants. In vivo studies widely use murine peri-implantitis models. Micro-computed tomography (micro-CT) is the gold standard method used to assess peri-implant bone changes in those models. However, no standardized protocol exists for image analysis, limiting comparability across studies. Objective: This study aimed to evaluate the effect of different micro-CT analysis parameters on bone measurements in a ligature-induced peri-implantitis mouse model. Methods: Seventeen C57BL/6J mice were divided into peri-implantitis (n = 8) and healthy (n = 9) groups. Following extraction and implant placement in the maxillary first molar region, peri-implantitis was induced via silk ligature placement. Micro-CT scans were analyzed by varying the volume of interest (VOI) size (2-thread vs. 5-thread spans), threshold values for bone and implant visualization, and measurement dimensionality (2D linear vs. 3D volumetric). Statistical significance (p < 0.05) was determined using unpaired t-tests or Mann–Whitney U tests, following Shapiro–Wilk normality assessment. Results: The 2-thread VOI yielded a highly significant difference in bone volume fraction (BV/TV) between groups (68.86 ± 4.97% vs. 50 ± 4.32%, p < 0.0001, Cohen’s d = 4.05), while the 5-thread VOI showed no significant difference. Thresholds of 60 and 200 were utilized for bone and implant segmentation, respectively, selected based on high inter-examiner reliability (Cohen’s kappa = 0.844 and 0.825, respectively). Two-dimensional analysis confirmed greater mesio-distal loss in the peri-implantitis group. Conclusions: A 2-thread coronal VOI combined with optimized thresholds provides a promising analytical approach for evaluating localized peri-implant bone changes in this exploratory model. While this approach demonstrated pronounced responsiveness within our dataset, further external validation across different imaging systems and operators is required to establish its role as a universal standard.

  • Open Access

    Early Osteogenic and Stromal Marker Responses of Osteoblast-like and Bone-Marrow Stromal Cell Lines to a Hyaluronic Acid-Coated Xenogeneic Bone Graft: An Exploratory In Vitro Analysis

    by Yaniv Mayer, Hia Abu Sada, Hadar Zigdon Giladi, Eran Gabay, Ofri Doppelt-Flikshtain, Ofir Ginesin

    Background: To investigate whether coating xenogeneic bone grafts with hyaluronic acid influences early osteogenic and fibrotic marker expression in vitro. Methods: Three xenograft materials were evaluated, including one hyaluronic acid-coated product and two uncoated deproteinized bovine bone mineral products, all commercially available. Human osteoblast-like cells (U2OS) and bone marrow stromal cells (HS5) were cultured with material extracts. Proliferation was assessed using XTT assay at 24 and 48 h. Cell adhesion was evaluated through fluorescence microscopy. Osteogenic markers (RUNX2, COL1A1) and fibrotic markers (COL3A1, TGF-β3) were quantified using quantitative real-time PCR. Statistical analysis employed one-way ANOVA with Benjamini–Krieger–Yekutieli (BKY) two-stage FDR correction for datasets that met the normality assumption, and the Kruskal–Wallis test with Dunn’s post hoc test for non-normally distributed data (HS5 XTT assay). Pairwise comparisons were restricted to each xenograft group versus the untreated control; an adjusted p-value < 0.05 was considered statistically significant. Results: At 48 h, the HA-coated xenograft (Xeno1) showed the highest mean metabolic activity in U2OS cells (0.538 ± 0.056) compared with the uncoated Xeno2 (0.450 ± 0.120) and Xeno3 (0.439 ± 0.073); however, after FDR correction no statistically significant differences were observed between groups. The coated material was associated with upregulation of early osteogenic markers, 2.61-fold RUNX2 upregulation (p = 0.01) compared to untreated cells. Both coated and uncoated xenografts demonstrated equivalent suppression of fibrotic markers in HS5 cells, reducing COL3A1 by 92.7% (p = 0.001) and TGF-β3 by 92.1% (p = 0.001). Conclusions: These exploratory in vitro findings suggest that HA coating may enhance early osteogenic marker expression. The observed effects on stromal markers warrant further investigation using primary cells, additional fibrotic endpoints (e.g., TGF-β1, ACTA2), and in vivo models before translational conclusions can be drawn.


  • Open Access

    Image Resolution's Impact on Artificial Intelligence & Human Accuracy in Full-Mouth Radiographic Analysis

    by Yaniv Mayer, Eran Gabay, Samah Jazmawi, Yaniv Skvirsky, Tarek Mtanis, Márton Kivovics, Sharonit Helft Sahar, Ofir Ginesin, Hadar Zigdon Giladi, Zvi Gutmacher


  • Open Access

    Salivary characteristics and oral microbial dynamics in patients before and after maxillectomy with obturator prosthesis: a pilot prospective cohort study

    by Thabet Asbi, Yaniv Mayer, Rafael Sarikov, Jamil A. Shibli, Ilan Hirsh, Doron Haim, Amin Boukhari, Zvi Gutmacher

    Maxillectomy produces extensive oral and maxillofacial defects that disrupt normal physiology and often require obturator prostheses for functional and aesthetic rehabilitation. Although these devices are routinely used, their influence on salivary characteristics and oral microbiota remains insufficiently understood. To compare pre- and postoperative salivary parameters, periodontal indices, and selected microbial species in patients undergoing partial maxillectomy and rehabilitated with obturator prostheses. In this pilot prospective cohort study, 14 adults scheduled for maxillectomy were evaluated. Unstimulated whole saliva was collected at baseline and at 6–8 months post maxillectomy. Clinical examinations assessed salivary flow, viscosity, periodontal indices, and semi-quantitative microbial profiles using commercial hybridization assays. Statistical tests were selected according to data type. Probing depth increased modestly (3.7 ± 0.7 mm to 3.9 ± 0.8 mm; P = 0.02), while plaque and gingival indices showed no significant changes. No significant changes were detected in either salivary flow and viscosity (6.97 ± 1.86 ml to 8.58 ± 2.29 ml, P = 0.58 and 1.50 ± 0.97 cps to 1.54 ± 0.96 cps, P = 0.64, respectively). Similarly, no statistically significant changes were detected in the prevalence of the selected microbial species, although a non-significant decrease in Aggregatibacter actinomycetemcomitans and an increase in Porphyromonas gingivalis were observed. Most other fungal and bacterial species showed similar prevalence across time points. Within the early postoperative period, salivary characteristics and oral microbial patterns remained generally unchanged following maxillectomy and obturator placement. Given the small and heterogeneous cohort, these preliminary outcomes warrant cautious interpretation and underscore the need for larger studies with extended follow-up time.