Pieter E. Oomen
Pieter E. Oomen has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Elisabeth Verpoorte
University of Groningen, Groningen Research Institute of Pharmacy (GRIP), Pharmaceutical Analysis, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands
6 shared publications B.H.C. Westerink
Brains On-Line BV, Groningen, the Netherlands; University of Groningen Institute of Pharmacy, Groningen, the Netherlands
2 shared publications- Klaus Mathwig
IMEC within OnePlanet Research Center, Bronland 10, 6708 WH Wageningen, The Netherlands
2 shared publications M.G. de Vries
Brains On-Line BV, Groningen, The Netherlands
2 shared publications- Ryan C. Chiechi
University of Groningen
2 shared publications Yanxi Zhang
Stratingh Institute for Chemistry and Zernike Institute for Advanced Materials
2 shared publications
Latest Publications
- 14 November 2026
- Published by Wiley in Drug Testing and Analysis
Quantitative Analysis of Lysergic Acid Diethylamide: A Ring Study Among Five Swiss Drug Checking Services
Lysergic acid diethylamide (LSD) is a serotonergic psychedelic with active dosages in the microgram range. Accurate information about the LSD content of blotters is essential for harm reduction. However, drug checking services (DCS) across Europe have reported that service users expect LSD contents to be considerably higher than what is measured analytically, raising questions about the accuracy and reliability of current methods used in DCS settings. This study presents an interlaboratory ring trial on LSD quantification within the context of drug checking. Five Swiss DCS laboratories participated, each employing different analytical techniques (HPLC‐DAD, GC–MS, and HPLC–MS/MS) and extraction procedures. Three sample types were distributed: two LSD‐infused blotters and one methanolic LSD solution. The quantitative results were corrected based on purity determined by proton nuclear magnetic resonance spectroscopy (qNMR) of the reference standard. Interlaboratory variability was low, with relative standard deviations of 8%–16.5% and mean accuracy ranging from −5.3% to −13.0%. Variability was higher for the liquid sample. The largest deviations were reported for mass spectrometry‐based methods. The study confirmed the reliability of LSD quantification across participating DCS laboratories. Additional factors that could potentially contribute to the reported discrepancy were discussed: limited stability of LSD, potential inconsistencies in clandestine blotter production methods, and user expectations shaped by marketing or anecdotal reports. The findings support the accuracy of current LSD quantification methods in drug checking settings and provide a foundation for future proficiency testing. Reliable chemical data is essential for accurate dosing and effective harm reduction.
- 14 November 2026
- Published by Wiley in Drug Testing and Analysis
Quantitative Analysis of Lysergic Acid Diethylamide: A Ring Study Among Five Swiss Drug Checking Services
Lysergic acid diethylamide (LSD) is a serotonergic psychedelic with active dosages in the microgram range. Accurate information about the LSD content of blotters is essential for harm reduction. However, drug checking services (DCS) across Europe have reported that service users expect LSD contents to be considerably higher than what is measured analytically, raising questions about the accuracy and reliability of current methods used in DCS settings. This study presents an interlaboratory ring trial on LSD quantification within the context of drug checking. Five Swiss DCS laboratories participated, each employing different analytical techniques (HPLC‐DAD, GC–MS, and HPLC–MS/MS) and extraction procedures. Three sample types were distributed: two LSD‐infused blotters and one methanolic LSD solution. The quantitative results were corrected based on purity determined by proton nuclear magnetic resonance spectroscopy (qNMR) of the reference standard. Interlaboratory variability was low, with relative standard deviations of 8%–16.5% and mean accuracy ranging from −5.3% to −13.0%. Variability was higher for the liquid sample. The largest deviations were reported for mass spectrometry‐based methods. The study confirmed the reliability of LSD quantification across participating DCS laboratories. Additional factors that could potentially contribute to the reported discrepancy were discussed: limited stability of LSD, potential inconsistencies in clandestine blotter production methods, and user expectations shaped by marketing or anecdotal reports. The findings support the accuracy of current LSD quantification methods in drug checking settings and provide a foundation for future proficiency testing. Reliable chemical data is essential for accurate dosing and effective harm reduction.
- Open Access
- 10 September 2026
- Published by Elsevier in SSRN Electronic Journal
In Vitro Evaluation of Reactive Oxygen Species Sensor for In Vivo Monitoring of Periprosthetic Infection and Inflammation
Introduction: Differentiating wear-induced hip and knee implant failure, such as aseptic and septic loosening, is challenging and can result in unnecessary operations or untreated infections, worsening patient outcomes. These failure modes arise from overlapping biological pathways, but differ in local H₂O₂ levels, reaching up to 100 µM during infection versus 5 µM during inflammation. Continuous in vivo H₂O₂ monitoring could increase true positive diagnoses and reduce complications. This in vitro study evaluated an electrochemical H₂O₂ sensor under simulated healthy, inflamed, and infected joint conditions, to assess its ability to distinguish between these failure modes after protein adsorption.Methods: Platinum sensors coated with Nafion- and m-phenylenediamine were exposed to phosphate-buffered saline, protein-rich fluid containing synovial fluid protein analogues, or blood serum for up to 16 hours at 35 or 40oC and 7.4 or 6.7 pH.Results: Sensor sensitivity, noise, and limit of detection met the requirements for infection detection but were insufficient for reliably detecting inflammation, particularly after exposure to the protein-rich fluid. The linearity remained excellent across all conditions (<0.985). Noise levels were influenced by fabrication variability, decreasing the overall reproducibility.Conclusion: The sensors were able to distinguish conditions seen in an infected joint from those seen in an inflamed or healthy joint across all testing conditions, suggesting potential clinical utility for continuous in vivo infection monitoring. They were unable to distinguish conditions seen in an inflamed joint from those seen in a healthy joint. Longer test durations and broader biological interactions should be researched before starting in vivo studies.
- 10 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessIn Vitro Evaluation of Reactive Oxygen Species Sensor for In Vivo Monitoring of Periprosthetic Infection and Inflammation
Introduction: Differentiating wear-induced hip and knee implant failure, such as aseptic and septic loosening, is challenging and can result in unnecessary operations or untreated infections, worsening patient outcomes. These failure modes arise from overlapping biological pathways, but differ in local H₂O₂ levels, reaching up to 100 µM during infection versus 5 µM during inflammation. Continuous in vivo H₂O₂ monitoring could increase true positive diagnoses and reduce complications. This in vitro study evaluated an electrochemical H₂O₂ sensor under simulated healthy, inflamed, and infected joint conditions, to assess its ability to distinguish between these failure modes after protein adsorption.Methods: Platinum sensors coated with Nafion- and m-phenylenediamine were exposed to phosphate-buffered saline, protein-rich fluid containing synovial fluid protein analogues, or blood serum for up to 16 hours at 35 or 40oC and 7.4 or 6.7 pH.Results: Sensor sensitivity, noise, and limit of detection met the requirements for infection detection but were insufficient for reliably detecting inflammation, particularly after exposure to the protein-rich fluid. The linearity remained excellent across all conditions (<0.985). Noise levels were influenced by fabrication variability, decreasing the overall reproducibility.Conclusion: The sensors were able to distinguish conditions seen in an infected joint from those seen in an inflamed or healthy joint across all testing conditions, suggesting potential clinical utility for continuous in vivo infection monitoring. They were unable to distinguish conditions seen in an inflamed joint from those seen in a healthy joint. Longer test durations and broader biological interactions should be researched before starting in vivo studies.
- 26 October 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (1) , 588-621
Chemical Analysis of Single Cells
- 26 October 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (1) , 588-621
Chemical Analysis of Single Cells
- 21 August 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (19) , 2913-2916
Electrochemical sensing with single nanoskived gold nanowires bisecting a microchannel
We suspended a single nanoskived gold nanowire in a microfluidic channel. In this preliminary report, a 200 nm-diameter nanowire was used as an electrode to perform hydrodynamic voltammetry in the center of solution flow. Suspended nanowires exhibit superior current response due to highly efficient mass transport in the area of fastest flow.
- 21 August 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (19) , 2913-2916
Electrochemical sensing with single nanoskived gold nanowires bisecting a microchannel
We suspended a single nanoskived gold nanowire in a microfluidic channel. In this preliminary report, a 200 nm-diameter nanowire was used as an electrode to perform hydrodynamic voltammetry in the center of solution flow. Suspended nanowires exhibit superior current response due to highly efficient mass transport in the area of fastest flow.
- 1 October 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 988, 50-57
Controlled, synchronized actuation of microdroplets by gravity in a superhydrophobic, 3D-printed device
- 1 October 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 988, 50-57
Controlled, synchronized actuation of microdroplets by gravity in a superhydrophobic, 3D-printed device
- Top Cited PapersOpen Access
- 19 June 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (13) , 7053-7061
Fused Deposition Modeling 3D Printing for (Bio)analytical Device Fabrication: Procedures, Materials, and Applications
In this work, the use of fused deposition modeling (FDM) in a (bio)analytical/lab-on-a-chip research laboratory is described. First, the specifications of this 3D printing method that are important for the fabrication of (micro)devices were characterized for a benchtop FDM 3D printer. These include resolution, surface roughness, leakage, transparency, material deformation, and the possibilities for integration of other materials. Next, the autofluorescence, solvent compatibility, and biocompatibility of 12 representative FDM materials were tested and evaluated. Finally, we demonstrate the feasibility of FDM in a number of important applications. In particular, we consider the fabrication of fluidic channels, masters for polymer replication, and tools for the production of paper microfluidic devices. This work thus provides a guideline for (i) the use of FDM technology by addressing its possibilities and current limitations, (ii) material selection for FDM, based on solvent compatibility and biocompatibility, and (iii) application of FDM technology to (bio)analytical research by demonstrating a broad range of illustrative examples.
- 19 June 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (13) , 7053-7061
Top Cited PapersOpen AccessFused Deposition Modeling 3D Printing for (Bio)analytical Device Fabrication: Procedures, Materials, and Applications
In this work, the use of fused deposition modeling (FDM) in a (bio)analytical/lab-on-a-chip research laboratory is described. First, the specifications of this 3D printing method that are important for the fabrication of (micro)devices were characterized for a benchtop FDM 3D printer. These include resolution, surface roughness, leakage, transparency, material deformation, and the possibilities for integration of other materials. Next, the autofluorescence, solvent compatibility, and biocompatibility of 12 representative FDM materials were tested and evaluated. Finally, we demonstrate the feasibility of FDM in a number of important applications. In particular, we consider the fabrication of fluidic channels, masters for polymer replication, and tools for the production of paper microfluidic devices. This work thus provides a guideline for (i) the use of FDM technology by addressing its possibilities and current limitations, (ii) material selection for FDM, based on solvent compatibility and biocompatibility, and (iii) application of FDM technology to (bio)analytical research by demonstrating a broad range of illustrative examples.
- 25 July 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (18) , 3394-3414
Implementing oxygen control in chip-based cell and tissue culture systems
Oxygen is essential in the energy metabolism of cells, as well as being an important regulatory parameter influencing cell differentiation and function. Interest in precise oxygen control for in vitro cultures of tissues and cells continues to grow, especially with the emergence of the organ-on-a-chip and the desire to emulate in vivo conditions. This was recently discussed in this journal in a Critical Review by Brennan et al. (Lab Chip (2014). DOI: 10.1039/C4LC00853G). Microfluidics can be used to introduce flow to facilitate nutrient supply to and waste removal from in vitro culture systems. Well-defined oxygen gradients can also be established. However, cells can quickly alter the oxygen balance in their vicinity. In this Tutorial Review, we expand on the Brennan paper to focus on the implementation of oxygen analysis in these systems to achieve continuous monitoring. Both electrochemical and optical approaches for the integration of oxygen monitoring in microfluidic tissue and cell culture systems will be discussed. Differences in oxygen requirements from one organ to the next are a challenging problem, as oxygen delivery is limited by its uptake into medium. Hence, we discuss the factors determining oxygen concentrations in solutions and consider the possible use of artificial oxygen carriers to increase dissolved oxygen concentrations. The selection of device material for applications requiring precise oxygen control is discussed in detail, focusing on oxygen permeability. Lastly, a variety of devices is presented, showing the diversity of approaches that can be employed to control and monitor oxygen concentrations in in vitro experiments.
- 25 July 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (18) , 3394-3414
Implementing oxygen control in chip-based cell and tissue culture systems
Oxygen is essential in the energy metabolism of cells, as well as being an important regulatory parameter influencing cell differentiation and function. Interest in precise oxygen control for in vitro cultures of tissues and cells continues to grow, especially with the emergence of the organ-on-a-chip and the desire to emulate in vivo conditions. This was recently discussed in this journal in a Critical Review by Brennan et al. (Lab Chip (2014). DOI: 10.1039/C4LC00853G). Microfluidics can be used to introduce flow to facilitate nutrient supply to and waste removal from in vitro culture systems. Well-defined oxygen gradients can also be established. However, cells can quickly alter the oxygen balance in their vicinity. In this Tutorial Review, we expand on the Brennan paper to focus on the implementation of oxygen analysis in these systems to achieve continuous monitoring. Both electrochemical and optical approaches for the integration of oxygen monitoring in microfluidic tissue and cell culture systems will be discussed. Differences in oxygen requirements from one organ to the next are a challenging problem, as oxygen delivery is limited by its uptake into medium. Hence, we discuss the factors determining oxygen concentrations in solutions and consider the possible use of artificial oxygen carriers to increase dissolved oxygen concentrations. The selection of device material for applications requiring precise oxygen control is discussed in detail, focusing on oxygen permeability. Lastly, a variety of devices is presented, showing the diversity of approaches that can be employed to control and monitor oxygen concentrations in in vitro experiments.
- 5 February 2016
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 10 (2) , 2852-2859
Bisecting Microfluidic Channels with Metallic Nanowires Fabricated by Nanoskiving
This paper describes the fabrication of millimeter-long gold nanowires that bisect the center of microfluidic channels. We fabricated the nanowires by nanoskiving and then suspended them over a trench in a glass structure. The channel was sealed by bonding it to a complementary poly(dimethylsiloxane) structure. The resulting structures place the nanowires in the region of highest flow, as opposed to the walls, where it approaches zero, and expose their entire surface area to fluid. We demonstrate active functionality, by constructing a hot-wire anemometer to measure flow through determining the change in resistance of the nanowire as a function of heat dissipation at low voltage (<5 V). Further, passive functionality is demonstrated by visualizing individual, fluorescently labeled DNA molecules attached to the wires. We measure rates of flow and show that, compared to surface-bound DNA strands, elongation saturates at lower rates of flow and background fluorescence from nonspecific binding is reduced.
- 5 February 2016
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 10 (2) , 2852-2859
Bisecting Microfluidic Channels with Metallic Nanowires Fabricated by Nanoskiving
This paper describes the fabrication of millimeter-long gold nanowires that bisect the center of microfluidic channels. We fabricated the nanowires by nanoskiving and then suspended them over a trench in a glass structure. The channel was sealed by bonding it to a complementary poly(dimethylsiloxane) structure. The resulting structures place the nanowires in the region of highest flow, as opposed to the walls, where it approaches zero, and expose their entire surface area to fluid. We demonstrate active functionality, by constructing a hot-wire anemometer to measure flow through determining the change in resistance of the nanowire as a function of heat dissipation at low voltage (<5 V). Further, passive functionality is demonstrated by visualizing individual, fluorescently labeled DNA molecules attached to the wires. We measure rates of flow and show that, compared to surface-bound DNA strands, elongation saturates at lower rates of flow and background fluorescence from nonspecific binding is reduced.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 224-227
How microtechnologies enable organs-on-a-chip
Engineering cellular microenvironments that more accurately reflect the in vivo situation is now recognized as being crucial for the improvement of the in vitro viability and in vivo-like function of cells or tissues. Microfluidic technologies have been increasingly applied since the late 1990's for this purpose, with a growing number of examples of perfused cell and tissue cultures in microfluidic chambers and channels. More recently, additional microfabricated features have been implemented in microfluidic structures to achieve 3-D cell culture systems which mimic not only in vivo fluid flows, but also the structure, transport, and mechanical properties of tissue in, for example, the lung or the intestine. The ultimate challenge becomes the combination of different organ functions into single, linked-compartment devices - the body-on-the-chip.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 224-227
How microtechnologies enable organs-on-a-chip
Engineering cellular microenvironments that more accurately reflect the in vivo situation is now recognized as being crucial for the improvement of the in vitro viability and in vivo-like function of cells or tissues. Microfluidic technologies have been increasingly applied since the late 1990's for this purpose, with a growing number of examples of perfused cell and tissue cultures in microfluidic chambers and channels. More recently, additional microfabricated features have been implemented in microfluidic structures to achieve 3-D cell culture systems which mimic not only in vivo fluid flows, but also the structure, transport, and mechanical properties of tissue in, for example, the lung or the intestine. The ultimate challenge becomes the combination of different organ functions into single, linked-compartment devices - the body-on-the-chip.
- 1 May 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 67, 677-686
In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device
- 1 May 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 67, 677-686
In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device