Evgeny Andreevich Levin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Evgeny Andreevich Levin has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Gennadij G. Knyazev
State Research Institute of Physiology, Siberian Branch of the Russian Academy of Medical Sciences, Novosibirsk, Russia
8 shared publications Alexander N. Savostyanov
6 shared publications- Alexander N. Savostyanov
Novosibirsk State University; Scientific Research Institute of Neurosciences and Medicine
5 shared publications - Andrey V. Bocharov
Novosibirsk State University; Scientific Research Institute of Neurosciences and Medicine
5 shared publications - A. A. Glushaeva
Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации, Новосибирск
3 shared publications - Gennady G. Knyazev
Institute of Neurosciences and Medicine, Novosibirsk, Russia
3 shared publications
Latest Publications
- Open Access
- 28 April 2025
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 29 (1) , 47-60
Automated selection of signal frequency filtering parameters for monitoring sensory evoked potentials: a pilot study
Introduction: The monitoring of somatosensory, visual and auditory evoked potentials (EP) is used to control the preservation of the corresponding functions. To detect promptly signs of their impairment, it is necessary to minimize the time intervals between consecutive recordings of EP. However, the low amplitude of the latter forces researchers to resort to averaging at recording them that involves the long-term accumulation of tens or hundreds of responses to repeated stimuli. Frequency filtering improves the signal-to-noise ratio and reduces the number of required averagings, but its optimal parameters vary among patients and their selection requires considerable time and highly qualified personnel. Objective: The study aimed to develop and test a method for automated selection of signal frequency filtering parameters using real data from intraoperative monitoring (IOM) of somatosensory and visual EPs and compare the results of automated selection with the choice made by an experienced neurophysiologist during surgery. Methods: The automated frequency filter selection technique was implemented in our own program, qt5-eeg-filters. It loads unfiltered EPs, filters them using a user-defined set of filters, compares the filtering results taking into account the reproducibility and amplitudes of the EPs, and provides the user with the recommended passband of the frequency filter. Unfiltered EPs of 23 patients (79 records) who underwent intraoperative neuromonitoring with personalized selection of filtering parameters were automatically analyzed using four variants of the filter optimality criterion. These variants were obtained by combining two parameters: (1) the method of assessing the reproducibility of EPs only by characteristics of the peaks (PV) or by a curve segment (CV) and (2) the peak amplitude values used, namely absolute (Abs) or relative values compared to background oscillations (Rel). For each variant, the correlation coefficients of the filtering parameters proposed by the program with those actually selected during IOM were calculated, and their differences were assessed. In addition, the proposed filters were evaluated by a neurophysiologist on a five-point scale for subsequent comparison of the four variants of the optimality criterion with each other. Nonparametric methods were used for statistical analysis: Spearman correlation and Friedman/Wilcoxon test. Results: With the optimality criteria of the AbsCV, RelCV, and RelPV types, the lower limit of the passband was higher than that selected by the neurophysiologist during IOM: p=0.00002, p=0.00003, and p=0.056, respectively, for visual EP (VEP), and p<0.00001, p<0.00001, and p=0.00002, respectively, for somatosensory EP (SSEP). With the same criteria, the upper limit of the passband was lower than that selected during IOM: p=0.00029, p=0.00002, and p=0.00037, respectively, for VEP, and p<0.00001, p<0.00001, and p=0.0002, respectively, for SSEP. Thus, with all these criteria, the program suggested using more "aggressive" filtering than the neurophysiologist actually used during the IOM (hereinafter referred to as "IOM filter"). With the optimality criterion of the AbsPV type, no clear trend was revealed; at the same time, the quality assessments of both SSEP and VEP selected with this criterion were the worst. The best quality assessments of the filters were obtained using the RelCV criterion for VEP (they did not differ significantly from the assessments for the IOM filter, p = 0.22) and AbsCV for SSEP (they were, however, worse than for the IOM filter, p = 0.0025). For both VEP and SSEP, positive correlations were observed between the quality assessments when using the IOM filter and the filters proposed by the program. For VEP they were 0.74 (p=0.00014), 0.72 (p=0.0003), 0.74 (p=0.00016) and 0.56 (p=0.019) when comparing the IOM filter with the filters obtained using the RelCV, AbsCV, RelPV and AbsPV criteria, respectively. For SSEP the corresponding correlations were 0.23 (p=0.085), 0.49 (p=0.00014), 0.45 (p=0.00050) and 0.57 (p=0.00001). In all cases when there were events that impaired the monitored function during IOM, the changes in EPs were reliably identified using both the IOM filters and the filters proposed by the program. However, the number of such events was insufficient for statistical analysis. Conclusion: We demonstrated the possibility of automated selection of frequency filtering parameters for sensory evoked potentials using a dataset obtained during real intraoperative neuromonitoring sessions. Prospects for the development of the method are associated with the extension of the analysis to the single-trial level. Received 2 December 2024. Accepted 11 December 2024. FundingThe study was supported by the Russian Science Foundation, grant No. 23-25-00322. The Foundation did not influence the development of the concept and design of the study, data collection and processing, interpretation of the results, preparation, publication, and other stages of the article creation. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: E.A. Levin, Ya.V. PisarevData collection and analysis: I.G. Mukhina, M.G. Kilchukov, A.A. Glushaeva, E.A. LevinStatistical analysis: M.G. Kilchukov, A.A. Glushaeva, E.A. LevinDrafting the article: E.A. Levin, Ya.V. PisarevCritical revision of the article: E.A. Levin, I.G. MukhinaFinal approval of the version to be published: E.A. Levin, Ya.V. Pisarev, I.G. Mukhina, A.A. Glushaeva, M.G. Kilchukov
- 28 April 2025
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 29 (1) , 47-60
Open AccessAutomated selection of signal frequency filtering parameters for monitoring sensory evoked potentials: a pilot study
Introduction: The monitoring of somatosensory, visual and auditory evoked potentials (EP) is used to control the preservation of the corresponding functions. To detect promptly signs of their impairment, it is necessary to minimize the time intervals between consecutive recordings of EP. However, the low amplitude of the latter forces researchers to resort to averaging at recording them that involves the long-term accumulation of tens or hundreds of responses to repeated stimuli. Frequency filtering improves the signal-to-noise ratio and reduces the number of required averagings, but its optimal parameters vary among patients and their selection requires considerable time and highly qualified personnel. Objective: The study aimed to develop and test a method for automated selection of signal frequency filtering parameters using real data from intraoperative monitoring (IOM) of somatosensory and visual EPs and compare the results of automated selection with the choice made by an experienced neurophysiologist during surgery. Methods: The automated frequency filter selection technique was implemented in our own program, qt5-eeg-filters. It loads unfiltered EPs, filters them using a user-defined set of filters, compares the filtering results taking into account the reproducibility and amplitudes of the EPs, and provides the user with the recommended passband of the frequency filter. Unfiltered EPs of 23 patients (79 records) who underwent intraoperative neuromonitoring with personalized selection of filtering parameters were automatically analyzed using four variants of the filter optimality criterion. These variants were obtained by combining two parameters: (1) the method of assessing the reproducibility of EPs only by characteristics of the peaks (PV) or by a curve segment (CV) and (2) the peak amplitude values used, namely absolute (Abs) or relative values compared to background oscillations (Rel). For each variant, the correlation coefficients of the filtering parameters proposed by the program with those actually selected during IOM were calculated, and their differences were assessed. In addition, the proposed filters were evaluated by a neurophysiologist on a five-point scale for subsequent comparison of the four variants of the optimality criterion with each other. Nonparametric methods were used for statistical analysis: Spearman correlation and Friedman/Wilcoxon test. Results: With the optimality criteria of the AbsCV, RelCV, and RelPV types, the lower limit of the passband was higher than that selected by the neurophysiologist during IOM: p=0.00002, p=0.00003, and p=0.056, respectively, for visual EP (VEP), and p<0.00001, p<0.00001, and p=0.00002, respectively, for somatosensory EP (SSEP). With the same criteria, the upper limit of the passband was lower than that selected during IOM: p=0.00029, p=0.00002, and p=0.00037, respectively, for VEP, and p<0.00001, p<0.00001, and p=0.0002, respectively, for SSEP. Thus, with all these criteria, the program suggested using more "aggressive" filtering than the neurophysiologist actually used during the IOM (hereinafter referred to as "IOM filter"). With the optimality criterion of the AbsPV type, no clear trend was revealed; at the same time, the quality assessments of both SSEP and VEP selected with this criterion were the worst. The best quality assessments of the filters were obtained using the RelCV criterion for VEP (they did not differ significantly from the assessments for the IOM filter, p = 0.22) and AbsCV for SSEP (they were, however, worse than for the IOM filter, p = 0.0025). For both VEP and SSEP, positive correlations were observed between the quality assessments when using the IOM filter and the filters proposed by the program. For VEP they were 0.74 (p=0.00014), 0.72 (p=0.0003), 0.74 (p=0.00016) and 0.56 (p=0.019) when comparing the IOM filter with the filters obtained using the RelCV, AbsCV, RelPV and AbsPV criteria, respectively. For SSEP the corresponding correlations were 0.23 (p=0.085), 0.49 (p=0.00014), 0.45 (p=0.00050) and 0.57 (p=0.00001). In all cases when there were events that impaired the monitored function during IOM, the changes in EPs were reliably identified using both the IOM filters and the filters proposed by the program. However, the number of such events was insufficient for statistical analysis. Conclusion: We demonstrated the possibility of automated selection of frequency filtering parameters for sensory evoked potentials using a dataset obtained during real intraoperative neuromonitoring sessions. Prospects for the development of the method are associated with the extension of the analysis to the single-trial level. Received 2 December 2024. Accepted 11 December 2024. FundingThe study was supported by the Russian Science Foundation, grant No. 23-25-00322. The Foundation did not influence the development of the concept and design of the study, data collection and processing, interpretation of the results, preparation, publication, and other stages of the article creation. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: E.A. Levin, Ya.V. PisarevData collection and analysis: I.G. Mukhina, M.G. Kilchukov, A.A. Glushaeva, E.A. LevinStatistical analysis: M.G. Kilchukov, A.A. Glushaeva, E.A. LevinDrafting the article: E.A. Levin, Ya.V. PisarevCritical revision of the article: E.A. Levin, I.G. MukhinaFinal approval of the version to be published: E.A. Levin, Ya.V. Pisarev, I.G. Mukhina, A.A. Glushaeva, M.G. Kilchukov
- Open Access
- 13 January 2025
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 15 (1) , 26
Intraoperative Monitoring of Sensory Evoked Potentials in Neurosurgery: A Personalized Approach
Sensory evoked potentials (EPs), namely, somatosensory, visual, and brainstem acoustic EPs, are used in neurosurgery to monitor the corresponding functions with the aim of preventing iatrogenic neurological complications. Functional deficiency usually precedes structural defect, being initially reversible, and prompt alarms may help surgeons achieve this aim. However, sensory EP registration requires presenting multiple stimuli and averaging of responses, which significantly lengthen this procedure. As delays can make intraoperative neuromonitoring (IONM) ineffective, it is important to reduce EP recording time. The possibility of speeding up EP recording relies on differences between IONM and outpatient clinical neurophysiology (CN). Namely, in IONM, the patient is her/his own control, and the neurophysiologist is less constrained by norms and standards than in outpatient CN. Therefore, neurophysiologists can perform a personalized selection of optimal locations of recording electrodes, frequency filter passbands, and stimulation rates. Varying some or all of these parameters, it is often possible to significantly improve the signal-to-noise ratio (SNR) for EPs and accelerate EP recording by up to several times. The aim of this paper is to review how this personalized approach is or may be applied during IONM for recording sensory EPs of each of the abovementioned modalities. Also, the problems hindering the implementation and dissemination of this approach and options for overcoming them are discussed here, as well as possible future developments.
- 13 January 2025
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 15 (1) , 26
Open AccessIntraoperative Monitoring of Sensory Evoked Potentials in Neurosurgery: A Personalized Approach
Sensory evoked potentials (EPs), namely, somatosensory, visual, and brainstem acoustic EPs, are used in neurosurgery to monitor the corresponding functions with the aim of preventing iatrogenic neurological complications. Functional deficiency usually precedes structural defect, being initially reversible, and prompt alarms may help surgeons achieve this aim. However, sensory EP registration requires presenting multiple stimuli and averaging of responses, which significantly lengthen this procedure. As delays can make intraoperative neuromonitoring (IONM) ineffective, it is important to reduce EP recording time. The possibility of speeding up EP recording relies on differences between IONM and outpatient clinical neurophysiology (CN). Namely, in IONM, the patient is her/his own control, and the neurophysiologist is less constrained by norms and standards than in outpatient CN. Therefore, neurophysiologists can perform a personalized selection of optimal locations of recording electrodes, frequency filter passbands, and stimulation rates. Varying some or all of these parameters, it is often possible to significantly improve the signal-to-noise ratio (SNR) for EPs and accelerate EP recording by up to several times. The aim of this paper is to review how this personalized approach is or may be applied during IONM for recording sensory EPs of each of the abovementioned modalities. Also, the problems hindering the implementation and dissemination of this approach and options for overcoming them are discussed here, as well as possible future developments.
- Open Access
- 27 December 2024
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 28 (4) , 68-77
Intraoperative stimulation mapping of sensory branches of the trigeminal nerve using unconditioned reflexes
Introduction: Intraoperative stimulation mapping enables to determine the location of nerves in the surgical field when visualization is difficult, as well as to identify visualized nerves, thereby reducing the risk of postoperative iatrogenic complications. Motor nerve mapping is widely used in neurosurgical procedures but only a few attempts at intraoperative sensory nerve mapping have been reported to date. The introduction of an effective method for mapping the sensory branches/portions of the trigeminal nerve can reduce the risk of complications such as facial hypo- and hyperesthesia after operations in the posterior cranial fossa. Objective: To demonstrate the possibility of using unconditioned reflex motor reactions for stimulation mapping of the sensory branches/portions of the trigeminal nerve.Methods: Intraoperative neuromonitoring records were analyzed in three patients with trigeminal neuralgia who underwent nerve stimulation mapping during microvascular decompression. The using of an extended to 40 ms time window for recording myographic responses enabled to record both short-latency direct motor responses to stimulation of motor nerves and long-latency reflex motor responses to stimulation of the sensory branches of the trigeminal nerve. Results: It was shown that unconditioned reflex reactions of the orbicularis oculi muscle (stimulation of the V1 portion of the trigeminal nerve, blink reflex) and tongue muscles (stimulation of V3, trigemino hypoglossal reflex) were successfully induced in patients under total intravenous anesthesia with both monopolar and bipolar stimulation. One patient also showed a reaction of the orbicularis oris muscle (stimulation of V2, snout reflex). The technique used enabled to differentiate not only the motor and sensory roots of the trigeminal nerve, but also its different sensory portions separately.Conclusion: The intraoperative stimulation mapping of sensory branches/portions of the trigeminal nerve via unconditioned reflex motor responses can be performed using the equipment and anesthesia regimen typical for motor nerve mapping. Received 10 October 2024. Revised 1 November 2024. Accepted 12 November 2024. Informed consentThe patients’ informed consent to use the records for medical purposes is obtained. FundingThe study was supported by the grant of Russian Science Foundation No. 23-25-00322. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsThe authors contributed equally to this article.
- 27 December 2024
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 28 (4) , 68-77
Open AccessIntraoperative stimulation mapping of sensory branches of the trigeminal nerve using unconditioned reflexes
Introduction: Intraoperative stimulation mapping enables to determine the location of nerves in the surgical field when visualization is difficult, as well as to identify visualized nerves, thereby reducing the risk of postoperative iatrogenic complications. Motor nerve mapping is widely used in neurosurgical procedures but only a few attempts at intraoperative sensory nerve mapping have been reported to date. The introduction of an effective method for mapping the sensory branches/portions of the trigeminal nerve can reduce the risk of complications such as facial hypo- and hyperesthesia after operations in the posterior cranial fossa. Objective: To demonstrate the possibility of using unconditioned reflex motor reactions for stimulation mapping of the sensory branches/portions of the trigeminal nerve.Methods: Intraoperative neuromonitoring records were analyzed in three patients with trigeminal neuralgia who underwent nerve stimulation mapping during microvascular decompression. The using of an extended to 40 ms time window for recording myographic responses enabled to record both short-latency direct motor responses to stimulation of motor nerves and long-latency reflex motor responses to stimulation of the sensory branches of the trigeminal nerve. Results: It was shown that unconditioned reflex reactions of the orbicularis oculi muscle (stimulation of the V1 portion of the trigeminal nerve, blink reflex) and tongue muscles (stimulation of V3, trigemino hypoglossal reflex) were successfully induced in patients under total intravenous anesthesia with both monopolar and bipolar stimulation. One patient also showed a reaction of the orbicularis oris muscle (stimulation of V2, snout reflex). The technique used enabled to differentiate not only the motor and sensory roots of the trigeminal nerve, but also its different sensory portions separately.Conclusion: The intraoperative stimulation mapping of sensory branches/portions of the trigeminal nerve via unconditioned reflex motor responses can be performed using the equipment and anesthesia regimen typical for motor nerve mapping. Received 10 October 2024. Revised 1 November 2024. Accepted 12 November 2024. Informed consentThe patients’ informed consent to use the records for medical purposes is obtained. FundingThe study was supported by the grant of Russian Science Foundation No. 23-25-00322. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsThe authors contributed equally to this article.
- Open Access
- 25 November 2024
- Published by MDPI AG in Preprints.org
Intraoperative Monitoring of Sensory Evoked Potentials in Neurosurgery: A Personalized Approach
Sensory evoked potentials (EPs), namely somatosensory, visual and brainstem acoustic EPs, are used in neurosurgery to monitor the corresponding functions with the aim of preventing iatrogenic neurological complications. Functional deficiency usually precede structural defect, being initially reversible, and prompt alarm may help surgeons to achieve this aim. However, sensory EPs registration requires presenting multiple stimuli and averaging of responses, which signifi-cantly lengthen this procedure. As delays can make intraoperative neuromonitoring (IONM) in-effective, it is important to reduce EP recording time. The possibility of speeding up EP recording relies on differences between IONM and clinical neurophysiology (CN; all sensory EPs were borrowed to IONM from CN). Namely, in IONM, the patient is her/his own control and neurophysiologist is less constrained by norms and standards when in CN. Therefore, neurophysiologist can perform personalized selection of op-timal locations of recording electrodes, frequency filters passbands and stimulation rates. Vary-ing some or all of these parameters, it is often possible to significantly improve signal-to-noise ratio (SNR) for EPs, and accelerate EP recording by up to several times. The aim of this paper is to review how this personalized approach is or may be applied during IONM for recording sensory EPs of each of abovementioned modalities. Also, the problems hindering implementation and dissemination of this approach and options for overcoming them are discussed here, as well as possible future developments.
- 25 November 2024
- Published by MDPI AG in Preprints.org
Open AccessIntraoperative Monitoring of Sensory Evoked Potentials in Neurosurgery: A Personalized Approach
Sensory evoked potentials (EPs), namely somatosensory, visual and brainstem acoustic EPs, are used in neurosurgery to monitor the corresponding functions with the aim of preventing iatrogenic neurological complications. Functional deficiency usually precede structural defect, being initially reversible, and prompt alarm may help surgeons to achieve this aim. However, sensory EPs registration requires presenting multiple stimuli and averaging of responses, which signifi-cantly lengthen this procedure. As delays can make intraoperative neuromonitoring (IONM) in-effective, it is important to reduce EP recording time. The possibility of speeding up EP recording relies on differences between IONM and clinical neurophysiology (CN; all sensory EPs were borrowed to IONM from CN). Namely, in IONM, the patient is her/his own control and neurophysiologist is less constrained by norms and standards when in CN. Therefore, neurophysiologist can perform personalized selection of op-timal locations of recording electrodes, frequency filters passbands and stimulation rates. Vary-ing some or all of these parameters, it is often possible to significantly improve signal-to-noise ratio (SNR) for EPs, and accelerate EP recording by up to several times. The aim of this paper is to review how this personalized approach is or may be applied during IONM for recording sensory EPs of each of abovementioned modalities. Also, the problems hindering implementation and dissemination of this approach and options for overcoming them are discussed here, as well as possible future developments.
- Open Access
- 6 September 2024
- Published by "MedINK" Publishing House in Russian journal of neurosurgery
- Vol. 26 (3) , 57-71
Intraoperative monitoring of visual evoked potentials: experience of 240 operations
Background. Intraoperative monitoring (IOM) of visual evoked potentials (VEPs) is used to inform surgeons about impacts on the visual system in order to prevent iatrogenic visual impairment. The VEP monitoring use become widespread only in the last decade; nowadays, there is no generally accepted methodology for its implementation, and the effectiveness of VEP monitoring and the factors determining it have not been sufficiently studied.Aim. The aim of the study was to investigate the factors influencing the VEP monitoring feasibility and effectiveness.Materials and methods. Data from 240 consecutive neurosurgical operations performed using VEP monitoring were retrospectively reviewed. IOM data (registration parameters, presence and type of VEP changes), patient characteristics (gender and age, tumor type and location, presence of preoperative visual dysfunctions), anesthesia parameters and postoperative changes in vision were studied. Statistical analysis was performed using χ2 and Mann–Whitney tests.Results. VEPs were obtained in 91.3 % of eyes with completely or partially preserved vision. The main factors reducing the chances to record VEPs successfully are preoperative visual disorders and the use of inhalation anesthesia. A personalized approach to the selection of reference electrodes and frequency filtering parameters makes it possible to reduce the number of averagings required for VEP recording and accelerate informing surgeons. With successful monitoring 59.1 % of eyes had no noticeable VEP changes; 5.8 % of eyes had signs of intraoperative improvement; 35.1 % had signs of deterioration. Among the last category, 60.7 % of eyes had full VEPs recovery afterwards. After surgery, new visual disorders were detected in 2.6 % of eyes without signs of intraoperative deterioration, in 6.7 % – with temporary deterioration, and in 19.3 % – with signs of deterioration persisted until IOM is finished. Assessing the sensitivity and specificity of VEP monitoring is hampered by the possibility of complications in the early postoperative period and IOM influence on the course and results of the operation. The proportion of total resections was maximal when VEP monitoring was successful. In the subgroup without preoperative visual impairments, the alarms during monitoring were associated with decrease in proportion of total resections proportion due to increase in proportion of subtotal resections.Conclusion. VEP monitoring with a personalized approach allows effective monitoring of visual functions preservation during neurosurgical operations.
- 6 September 2024
- Published by "MedINK" Publishing House in Russian journal of neurosurgery
- Vol. 26 (3) , 57-71
Open AccessIntraoperative monitoring of visual evoked potentials: experience of 240 operations
Background. Intraoperative monitoring (IOM) of visual evoked potentials (VEPs) is used to inform surgeons about impacts on the visual system in order to prevent iatrogenic visual impairment. The VEP monitoring use become widespread only in the last decade; nowadays, there is no generally accepted methodology for its implementation, and the effectiveness of VEP monitoring and the factors determining it have not been sufficiently studied.Aim. The aim of the study was to investigate the factors influencing the VEP monitoring feasibility and effectiveness.Materials and methods. Data from 240 consecutive neurosurgical operations performed using VEP monitoring were retrospectively reviewed. IOM data (registration parameters, presence and type of VEP changes), patient characteristics (gender and age, tumor type and location, presence of preoperative visual dysfunctions), anesthesia parameters and postoperative changes in vision were studied. Statistical analysis was performed using χ2 and Mann–Whitney tests.Results. VEPs were obtained in 91.3 % of eyes with completely or partially preserved vision. The main factors reducing the chances to record VEPs successfully are preoperative visual disorders and the use of inhalation anesthesia. A personalized approach to the selection of reference electrodes and frequency filtering parameters makes it possible to reduce the number of averagings required for VEP recording and accelerate informing surgeons. With successful monitoring 59.1 % of eyes had no noticeable VEP changes; 5.8 % of eyes had signs of intraoperative improvement; 35.1 % had signs of deterioration. Among the last category, 60.7 % of eyes had full VEPs recovery afterwards. After surgery, new visual disorders were detected in 2.6 % of eyes without signs of intraoperative deterioration, in 6.7 % – with temporary deterioration, and in 19.3 % – with signs of deterioration persisted until IOM is finished. Assessing the sensitivity and specificity of VEP monitoring is hampered by the possibility of complications in the early postoperative period and IOM influence on the course and results of the operation. The proportion of total resections was maximal when VEP monitoring was successful. In the subgroup without preoperative visual impairments, the alarms during monitoring were associated with decrease in proportion of total resections proportion due to increase in proportion of subtotal resections.Conclusion. VEP monitoring with a personalized approach allows effective monitoring of visual functions preservation during neurosurgical operations.
- 1 September 2023
- Published by Edizioni Minerva Medica in Journal of Neurosurgical Sciences
- Vol. 68 (1) , 142-143
Inhalational anesthesia during intraoperative monitoring of visual evoked potentials: taboo or option?
Article: Inhalational anesthesia during intraoperative monitoring of visual evoked potentials: taboo or option? - Journal of Neurosurgical Sciences 2023 Sep 13 - Minerva Medica - Journals
- 1 September 2023
- Published by Edizioni Minerva Medica in Journal of Neurosurgical Sciences
- Vol. 68 (1) , 142-143
Inhalational anesthesia during intraoperative monitoring of visual evoked potentials: taboo or option?
Article: Inhalational anesthesia during intraoperative monitoring of visual evoked potentials: taboo or option? - Journal of Neurosurgical Sciences 2023 Sep 13 - Minerva Medica - Journals
- 1 February 2022
- Published by Elsevier in Neurochirurgie
- Vol. 68 (2) , 223-227
Electrophysiological reactions to intraoperative irritation of the optic nerve. Case report and review of possible mechanisms
- 1 February 2022
- Published by Elsevier in Neurochirurgie
- Vol. 68 (2) , 223-227
Electrophysiological reactions to intraoperative irritation of the optic nerve. Case report and review of possible mechanisms
- Open Access
Associations of Hyperactivity and Inattention Scores with Theta and Beta Oscillatory Dynamics of EEG in Stop-Signal Task in Healthy Children 7–10 Years Old
In the current study, we aimed to investigate the associations between the natural variability in hyperactivity and inattention scores, as well as their combination with EEG oscillatory responses in the Stop-Signal task in a sample of healthy children. During performance, the Stop-Signal task EEGs were recorded in 94 Caucasian children (40 girls) from 7 to 10 years. Hyperactivity/inattention and inattention scores positively correlated with RT variability. Hyperactivity/inattention and inattention scores negatively correlated with an increase in beta spectral power in the first 200 ms after presentation of the Go stimulus. Such results are in line with the lack of arousal model in ADHD children and can be associated with less sensory arousal in the early stages of perception in children with symptoms of inattention. The subsequent greater increase in theta rhythm at about 300 ms after presentation of the Go stimulus in children with higher inattention scores may be associated with increased attention processes and compensation for insufficient vigilance in the early stages of perception.
Open AccessAssociations of Hyperactivity and Inattention Scores with Theta and Beta Oscillatory Dynamics of EEG in Stop-Signal Task in Healthy Children 7–10 Years Old
In the current study, we aimed to investigate the associations between the natural variability in hyperactivity and inattention scores, as well as their combination with EEG oscillatory responses in the Stop-Signal task in a sample of healthy children. During performance, the Stop-Signal task EEGs were recorded in 94 Caucasian children (40 girls) from 7 to 10 years. Hyperactivity/inattention and inattention scores positively correlated with RT variability. Hyperactivity/inattention and inattention scores negatively correlated with an increase in beta spectral power in the first 200 ms after presentation of the Go stimulus. Such results are in line with the lack of arousal model in ADHD children and can be associated with less sensory arousal in the early stages of perception in children with symptoms of inattention. The subsequent greater increase in theta rhythm at about 300 ms after presentation of the Go stimulus in children with higher inattention scores may be associated with increased attention processes and compensation for insufficient vigilance in the early stages of perception.
- 1 November 2015
- Published by Pleiades Publishing Ltd in Russian Journal of Genetics: Applied Research
- Vol. 5 (6) , 656-665
Association of anxiety level with polymorphic variants of serotonin transporter gene in Russians and Tuvinians
- 1 November 2015
- Published by Pleiades Publishing Ltd in Russian Journal of Genetics: Applied Research
- Vol. 5 (6) , 656-665
Association of anxiety level with polymorphic variants of serotonin transporter gene in Russians and Tuvinians