Mariana de Sousa Rabelo
Mariana de Sousa Rabelo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Umberto Demoner Ramos
Department of Clinical Dentistry Health Sciences Center Federal University of Espirito Santo (UFES) Vitoria ES Brazil
4 shared publications - Amanda Finger Stadler
Department of Periodontology, Endodontics, and Dental Hygiene Chapel Hill Adams School of Dentistry University of North Carolina Chapel Hill North Carolina USA
3 shared publications - Cristiano Susin
Department of Periodontology, Endodontics, and Dental Hygiene Adams School of Dentistry University of North Carolina at Chapel Hill Chapel Hill North Carolina USA
3 shared publications - Tiago Fiorini
Department of Conservative Dentistry - Periodontology, Federal University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
3 shared publications - Marta Liliana Musskopf
Department of Restorative Sciences Chapel Hill Adams School of Dentistry University of North Carolina Chapel Hill North Carolina USA
2 shared publications Adriana Moura Foz
Division of Periodontics Department of Stomatology School of Dentistry University of São Paulo São Paulo Brazil
1 shared publication
Latest Publications
- Open Access
- 19 October 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (1) , 40-51
Performance of a new implant system and drilling protocol—A minipig intraoral dental implant model study
Aim: A new implant system encompassing implants with a tri‐oval cross‐sectional design and a simplified site preparation protocol at low speed and no irrigation has been developed. The objective of this study was to assess the safety and efficacy of the new implant system using the minipig intraoral dental implant model.Methods: Eight Yucatan minipigs were included. Twelve weeks after extractions, four implants per animal were randomly placed and allowed to heal transmucosal for 13 weeks: two Ø3.5 × 10 mm implants with a back‐tapered collar and circular cross‐section (control) and two Ø3.5 × 11 mm implants with tri‐oval collar and cross‐section (test). MicroCT and histological analysis was performed.Results: Thirty‐two implants were placed; one implant for the control group was lost. Histologically, BIC was higher in the test compared with the control group (74.1% vs. 60.9%, p < .001). At the platform level, inflammation was statistically significantly higher albeit mild in the test compared with the control group. No other significant differences were observed between groups. MicroCT analysis showed that bone‐to‐implant‐contact (BIC) and trabecular thickness were statistically significantly higher for the test than the control group. Test group had significantly higher first BIC distance than controls on lingual sites.Conclusions: The present study results support the safety and efficacy of the new dental implant system and simplified site preparation protocol; human studies should be carried out to confirm these findings.
- 19 October 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (1) , 40-51
Open AccessPerformance of a new implant system and drilling protocol—A minipig intraoral dental implant model study
Aim: A new implant system encompassing implants with a tri‐oval cross‐sectional design and a simplified site preparation protocol at low speed and no irrigation has been developed. The objective of this study was to assess the safety and efficacy of the new implant system using the minipig intraoral dental implant model.Methods: Eight Yucatan minipigs were included. Twelve weeks after extractions, four implants per animal were randomly placed and allowed to heal transmucosal for 13 weeks: two Ø3.5 × 10 mm implants with a back‐tapered collar and circular cross‐section (control) and two Ø3.5 × 11 mm implants with tri‐oval collar and cross‐section (test). MicroCT and histological analysis was performed.Results: Thirty‐two implants were placed; one implant for the control group was lost. Histologically, BIC was higher in the test compared with the control group (74.1% vs. 60.9%, p < .001). At the platform level, inflammation was statistically significantly higher albeit mild in the test compared with the control group. No other significant differences were observed between groups. MicroCT analysis showed that bone‐to‐implant‐contact (BIC) and trabecular thickness were statistically significantly higher for the test than the control group. Test group had significantly higher first BIC distance than controls on lingual sites.Conclusions: The present study results support the safety and efficacy of the new dental implant system and simplified site preparation protocol; human studies should be carried out to confirm these findings.
- 21 September 2019
- Published by Wiley in Oral Diseases
- Vol. 25 (8) , 2020-2029
Influence of T2DM and prediabetes on blood DC subsets and function in subjects with periodontitis
Objective: To compare the myeloid and plasmacytoid DC counts and maturation status among subjects with/without generalized periodontitis (GP) and type 2 diabetes mellitus (T2DM).Methods: The frequency and maturation status of myeloid and plasmacytoid blood DCs were analyzed by flow cytometry in four groups of 15 subjects: healthy controls, T2DM with generalized CP (T2DM + GP), prediabetes with GP (PD + GP), and normoglycemics with GP (NG + GP). RT‐PCR was used to determine levels of Porphyromonas gingivalis in the oral biofilms and within panDCs. The role of exogenous glucose effects on differentiation and apoptosis of healthy human MoDCs was explored in vitro.Results: Relative to controls and to NG + GP, T2DM + GP showed significantly lower CD1c + and CD303 + DC counts, while CD141 + DCs were lower in T2DM + GP relative to controls. Blood DC maturation required for mobilization and immune responsiveness was not observed. A statistically significant trend was observed for P. gingivalis levels in the biofilms of groups as follows: controls P. gingivalis levels were observed in blood DCs of NG + GP than controls, whereas no differences were observed between controls and PD + GP/T2DM + GP. In vitro differentiation of MoDCs was significantly decreased, and apoptosis was increased by physiologically relevant glucose levels.Conclusion: Type 2 diabetes mellitus appears to inhibit important DC immune homeostatic functions, including expansion and bacterial scavenging, which might be mediated by hyperglycemia.
- 21 September 2019
- Published by Wiley in Oral Diseases
- Vol. 25 (8) , 2020-2029
Influence of T2DM and prediabetes on blood DC subsets and function in subjects with periodontitis
Objective: To compare the myeloid and plasmacytoid DC counts and maturation status among subjects with/without generalized periodontitis (GP) and type 2 diabetes mellitus (T2DM).Methods: The frequency and maturation status of myeloid and plasmacytoid blood DCs were analyzed by flow cytometry in four groups of 15 subjects: healthy controls, T2DM with generalized CP (T2DM + GP), prediabetes with GP (PD + GP), and normoglycemics with GP (NG + GP). RT‐PCR was used to determine levels of Porphyromonas gingivalis in the oral biofilms and within panDCs. The role of exogenous glucose effects on differentiation and apoptosis of healthy human MoDCs was explored in vitro.Results: Relative to controls and to NG + GP, T2DM + GP showed significantly lower CD1c + and CD303 + DC counts, while CD141 + DCs were lower in T2DM + GP relative to controls. Blood DC maturation required for mobilization and immune responsiveness was not observed. A statistically significant trend was observed for P. gingivalis levels in the biofilms of groups as follows: controls P. gingivalis levels were observed in blood DCs of NG + GP than controls, whereas no differences were observed between controls and PD + GP/T2DM + GP. In vitro differentiation of MoDCs was significantly decreased, and apoptosis was increased by physiologically relevant glucose levels.Conclusion: Type 2 diabetes mellitus appears to inhibit important DC immune homeostatic functions, including expansion and bacterial scavenging, which might be mediated by hyperglycemia.
- Open Access
- 12 March 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (S1) , 44-54
Safety and efficacy of a novel, gradually anodized dental implant surface: A study in Yucatan mini pigs
Background: A newly developed dental implant system combining advancements in surface chemistry, topography, nanostructure, color, and surface energy aims to address biological challenges and expand clinical applications.Purpose: To assess the short‐ and long‐term safety and efficacy of a novel, gradually anodized dental implant surface/anodized abutment.Materials and Methods: Twenty‐four Yucatan mini pigs (20‐24 months old) received two dental implants in each jaw quadrant. Each site was randomized to receive either a commercially available anodized implant/machined abutment or a gradually anodized implant/anodized abutment with a protective layer. Animals were euthanized at 3, 6, and 13 weeks. Microcomputed tomography and histological analyses were performed.Results: No significant histological differences in inflammation scores, epithelium length, bone‐to‐implant contact, or bone density were observed between groups for any healing time. Mucosal height was significantly higher at 3 weeks for controls (Δ = 0.2 mm); no differences were observed at 6 and 13 weeks. No significant differences in radiographic bone volume, bone‐to‐implant contact, trabecular thickness, and crestal bone levels were observed, irrespective of healing time. Trabecular spacing was borderline significant at 3 weeks in favor of the test implant sites; no differences were observed at 6 weeks. No significant differences were observed between experimental groups at 13 weeks.Conclusions: The new implant system yielded results comparable to a commercially available predicate device.
- 12 March 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (S1) , 44-54
Open AccessSafety and efficacy of a novel, gradually anodized dental implant surface: A study in Yucatan mini pigs
Background: A newly developed dental implant system combining advancements in surface chemistry, topography, nanostructure, color, and surface energy aims to address biological challenges and expand clinical applications.Purpose: To assess the short‐ and long‐term safety and efficacy of a novel, gradually anodized dental implant surface/anodized abutment.Materials and Methods: Twenty‐four Yucatan mini pigs (20‐24 months old) received two dental implants in each jaw quadrant. Each site was randomized to receive either a commercially available anodized implant/machined abutment or a gradually anodized implant/anodized abutment with a protective layer. Animals were euthanized at 3, 6, and 13 weeks. Microcomputed tomography and histological analyses were performed.Results: No significant histological differences in inflammation scores, epithelium length, bone‐to‐implant contact, or bone density were observed between groups for any healing time. Mucosal height was significantly higher at 3 weeks for controls (Δ = 0.2 mm); no differences were observed at 6 and 13 weeks. No significant differences in radiographic bone volume, bone‐to‐implant contact, trabecular thickness, and crestal bone levels were observed, irrespective of healing time. Trabecular spacing was borderline significant at 3 weeks in favor of the test implant sites; no differences were observed at 6 weeks. No significant differences were observed between experimental groups at 13 weeks.Conclusions: The new implant system yielded results comparable to a commercially available predicate device.
- Open Access
- 12 March 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (S1) , 34-43
Safety and efficacy of a novel anodized abutment on soft tissue healing in Yucatan mini‐pigs
Background It is well established that electrochemical anodization of implant surfaces contributes to osseointegration and long‐term implant survival. Few studies have investigated its effect on soft tissue healing. Purpose To evaluate the safety and efficacy of a novel abutment surface prepared by electrochemical oxidation compared to commercially available machined titanium abutments. Materials and Methods Twelve 16‐19 months‐old, Yucatan mini‐pigs received three dental implants in each mandibular jaw quadrant. Each side was randomized to receive either an anodized or a machined titanium abutment. Titanium healing caps were placed on both abutments. Animals were euthanized at 6 and 13 weeks. Radiographic and histological analyses were performed. Results No significant differences were observed histologically between groups in regard to inflammation, epithelium length, mucosal height, bone‐to‐implant contact, or bone density for any time point. Radiographically, crestal bone level change from baseline to 6 weeks was significantly lower for anodized than machined abutments (P = 0.046); no significant differences were observed at 13 weeks (P = 0.12). Conclusions The novel anodized abutment showed a comparable effect on soft and hard tissue healing/remodeling and inflammation reaction to standard titanium abutments. Clinical studies should confirm these findings and explore the positive radiographic results observed at the early time point.
- 12 March 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (S1) , 34-43
Open AccessSafety and efficacy of a novel anodized abutment on soft tissue healing in Yucatan mini‐pigs
Background It is well established that electrochemical anodization of implant surfaces contributes to osseointegration and long‐term implant survival. Few studies have investigated its effect on soft tissue healing. Purpose To evaluate the safety and efficacy of a novel abutment surface prepared by electrochemical oxidation compared to commercially available machined titanium abutments. Materials and Methods Twelve 16‐19 months‐old, Yucatan mini‐pigs received three dental implants in each mandibular jaw quadrant. Each side was randomized to receive either an anodized or a machined titanium abutment. Titanium healing caps were placed on both abutments. Animals were euthanized at 6 and 13 weeks. Radiographic and histological analyses were performed. Results No significant differences were observed histologically between groups in regard to inflammation, epithelium length, mucosal height, bone‐to‐implant contact, or bone density for any time point. Radiographically, crestal bone level change from baseline to 6 weeks was significantly lower for anodized than machined abutments (P = 0.046); no significant differences were observed at 13 weeks (P = 0.12). Conclusions The novel anodized abutment showed a comparable effect on soft and hard tissue healing/remodeling and inflammation reaction to standard titanium abutments. Clinical studies should confirm these findings and explore the positive radiographic results observed at the early time point.
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 33 (suppl 1) , e071
New strategies and developments for peri-implant disease
The aim of this illustrated review is to present the new strategies and developments to treatment and diagnosis of periimplant diseases. Periimplant disease is a subject of great concern for modern dentistry. The numbers of implant exhibiting biological complications grows as implant dentistry expands thought-out the world. Diagnosis and treatment of those diseases are still controversial and difficult. We present novel treatment for infection control and biological rationale of additional use of guided bone regeneration, with an illustrative explanation of the treatments presented with two cases.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 33 (suppl 1) , e071
Open AccessNew strategies and developments for peri-implant disease
The aim of this illustrated review is to present the new strategies and developments to treatment and diagnosis of periimplant diseases. Periimplant disease is a subject of great concern for modern dentistry. The numbers of implant exhibiting biological complications grows as implant dentistry expands thought-out the world. Diagnosis and treatment of those diseases are still controversial and difficult. We present novel treatment for infection control and biological rationale of additional use of guided bone regeneration, with an illustrative explanation of the treatments presented with two cases.