Eiji Itoi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eiji Itoi has a total of 399 co-authors. Here are the top co-authors by number of shared publications:
Nobuyuki Yamamoto
Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan
43 shared publications- Nobuyuki Yamamoto
Department of Sports Medicine and Reconstruction of Motion Function, Tohoku University School of Medicine, Sendai, Japan
24 shared publications - Jun Kawakami
Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan
16 shared publications Hirotaka Sano
Division of Orthopedic Surgery, Sendai City Hospital, Sendai, Japan
15 shared publications- Hirotaka Sano
Division of Orthopedics, Sendai City Hospital, Sendai, Japan
14 shared publications Taku Hatta
Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan
14 shared publications
Latest Publications
- Open Access
- 17 July 2026
- Published by Elsevier in Journal of Shoulder and Elbow Arthroplasty
- Vol. 10 (4)
Fatty change in rotator cuff muscles following reverse total shoulder arthroplasty: does the humeral component design matter?
- 17 July 2026
- Published by Elsevier in Journal of Shoulder and Elbow Arthroplasty
- Vol. 10 (4)
Open AccessFatty change in rotator cuff muscles following reverse total shoulder arthroplasty: does the humeral component design matter?
- Open Access
- 21 February 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 224, 4-19
Bone regeneration, tendon fiber formation, and angiogenesis are enhanced by the multifaceted effects of biodegradable octacalcium phosphate and gelatin scaffold materials
- 21 February 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 224, 4-19
Open AccessBone regeneration, tendon fiber formation, and angiogenesis are enhanced by the multifaceted effects of biodegradable octacalcium phosphate and gelatin scaffold materials
- Open Access
- 28 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (3) , 101636
Optimizing reverse total shoulder arthroplasty for combined loss of elevation and external rotation: latissimus dorsi and teres major transfer, lateralization, or both?
- 28 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (3) , 101636
Open AccessOptimizing reverse total shoulder arthroplasty for combined loss of elevation and external rotation: latissimus dorsi and teres major transfer, lateralization, or both?
- Open Access
- 13 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (2) , 101624
Fatty change and muscle atrophy in patients with rotator cuff tears: a prospective study with a mean 6-year follow-up
- 13 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (2) , 101624
Open AccessFatty change and muscle atrophy in patients with rotator cuff tears: a prospective study with a mean 6-year follow-up
- Open Access
- 5 August 2025
- Published by Elsevier in JSES International
- Vol. 9 (6) , 1953-1958
Long-term outcomes of arthroscopic Bankart repair: a 10-year follow-up study
- 5 August 2025
- Published by Elsevier in JSES International
- Vol. 9 (6) , 1953-1958
Open AccessLong-term outcomes of arthroscopic Bankart repair: a 10-year follow-up study
- Open Access
- 14 June 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1731-1738
Uncemented vs. cemented reverse total shoulder arthroplasty with latissimus dorsi and teres major transfer
- 14 June 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1731-1738
Open AccessUncemented vs. cemented reverse total shoulder arthroplasty with latissimus dorsi and teres major transfer
- Open Access
- 2 April 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (12) , 2678-2684
The conventional magnetic resonance method may overestimate off-track Hill-Sachs lesions
- 2 April 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (12) , 2678-2684
Open AccessThe conventional magnetic resonance method may overestimate off-track Hill-Sachs lesions
- 3 March 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-10
The reverse shoulder arthroplasty angle may contribute to overt inferior inclination: comparison with alternative parameters
Purpose Radiographic measurements have gained wide acceptance in anticipating the risk of inappropriate glenoid component positioning in reverse shoulder arthroplasty (RSA). This study aims to investigate whether the RSA angle overcorrects the base plate inclination, tilting it inferiorly, compared to the base plate correction angle (BCA), which provides neutral inclination and lateralization. Methods One hundred normal anteroposterior shoulder radiographs were evaluated to determine the average values of the RSA angle, BCA, base plate orientation angle (BOA), and the base plate shoulder angle (BSA), which represents the amount of overcorrection accomplished via the RSA angle beyond the BCA’s scope. The interobserver reliability among two independent testers was assessed by the intraclass correlation coefficient. A t-test was applied to compare the mean values of the BCA and RSA angle. Results The mean BOA and BCA values were 118° ± 5.7° and 17° ± 4.6°, respectively. The RSA angle value was 23° ± 6°. Compared to the BCA, the RSA angle overcorrected the base plate inclination by 15° ± 5° (BSA). The Student’s t-test showed a statistically significant difference between the values of the BCA and RSA angle (p-value = 0.000). The interobserver reliability was excellent for all angle measurements among two independent testers. Conclusion The RSA angle and the BOA/BCA are reliable radiographic measurements to determine the inclination of the inferior glenoid segment prior to RSA. However, surgeons need to consider the inherent inferior inclination associated with positioning the base plate according to the RSA angle (15° ± 5°).
- 3 March 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-10
The reverse shoulder arthroplasty angle may contribute to overt inferior inclination: comparison with alternative parameters
Purpose Radiographic measurements have gained wide acceptance in anticipating the risk of inappropriate glenoid component positioning in reverse shoulder arthroplasty (RSA). This study aims to investigate whether the RSA angle overcorrects the base plate inclination, tilting it inferiorly, compared to the base plate correction angle (BCA), which provides neutral inclination and lateralization. Methods One hundred normal anteroposterior shoulder radiographs were evaluated to determine the average values of the RSA angle, BCA, base plate orientation angle (BOA), and the base plate shoulder angle (BSA), which represents the amount of overcorrection accomplished via the RSA angle beyond the BCA’s scope. The interobserver reliability among two independent testers was assessed by the intraclass correlation coefficient. A t-test was applied to compare the mean values of the BCA and RSA angle. Results The mean BOA and BCA values were 118° ± 5.7° and 17° ± 4.6°, respectively. The RSA angle value was 23° ± 6°. Compared to the BCA, the RSA angle overcorrected the base plate inclination by 15° ± 5° (BSA). The Student’s t-test showed a statistically significant difference between the values of the BCA and RSA angle (p-value = 0.000). The interobserver reliability was excellent for all angle measurements among two independent testers. Conclusion The RSA angle and the BOA/BCA are reliable radiographic measurements to determine the inclination of the inferior glenoid segment prior to RSA. However, surgeons need to consider the inherent inferior inclination associated with positioning the base plate according to the RSA angle (15° ± 5°).
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 274-282
Is the Subscapularis Function Preserved after the Latarjet Procedure? A Quantitative Analysis Using Positron Emission Tomography
Aizawa K, et al. Clin Orthop Surg. 2024 Dec;17:e3. https://doi.org/10.4055/cios24079
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 274-282
Open AccessIs the Subscapularis Function Preserved after the Latarjet Procedure? A Quantitative Analysis Using Positron Emission Tomography
Aizawa K, et al. Clin Orthop Surg. 2024 Dec;17:e3. https://doi.org/10.4055/cios24079
- Open Access
- 6 September 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (17) , 5294
Changes in the Articular Cartilage Thickness in Patients with Symptomatic Rotator Cuff Tears: A Prospective Study with a Mean 5-Year Follow-Up
Objectives: The purpose of this study was to prospectively investigate the progression of cartilage thinning in patients with symptomatic rotator cuff tears using MRI. Methods: Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2019. Of these, 28 shoulders of 27 patients (mean age, 65 years) who underwent at least two magnetic resonance imaging (MRI) examinations were prospectively enrolled. They all received conservative treatment. The mean follow-up was 67 months. Changes in cartilage thickness and the combined cartilage and subchondral bone thickness at the initial and final MRI were measured using a RadiAnt DICOM-viewer (Medixant, Poznan, Poland). The cartilage thickness of the humeral head was measured in the oblique coronal and sagittal images. The glenoid cartilage was measured in the axial and oblique coronal images. Results: At an average period of 5 years, 12 of 28 shoulders (42%) showed more than a 30% decrease in cartilage thickness in the humeral head. The glenoid showed cartilage thinning in only one shoulder (4%). In the humeral head, progressive cartilage thinning was seen mainly in the anterior and posterior parts of the humeral head in the sagittal plane. In the glenoid, progressive cartilage thinning was seen on the entire surface except the posterior area. There was no significant difference in cartilage thickness between the first and final follow-ups for both the humeral head and the glenoid. Conclusions: A total of 12 of 28 shoulders (42%) showed more than a 30% decrease in cartilage thickness in the humeral head, which was mainly observed in the anterior and posterior areas of the humeral head.
- 6 September 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (17) , 5294
Open AccessChanges in the Articular Cartilage Thickness in Patients with Symptomatic Rotator Cuff Tears: A Prospective Study with a Mean 5-Year Follow-Up
Objectives: The purpose of this study was to prospectively investigate the progression of cartilage thinning in patients with symptomatic rotator cuff tears using MRI. Methods: Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2019. Of these, 28 shoulders of 27 patients (mean age, 65 years) who underwent at least two magnetic resonance imaging (MRI) examinations were prospectively enrolled. They all received conservative treatment. The mean follow-up was 67 months. Changes in cartilage thickness and the combined cartilage and subchondral bone thickness at the initial and final MRI were measured using a RadiAnt DICOM-viewer (Medixant, Poznan, Poland). The cartilage thickness of the humeral head was measured in the oblique coronal and sagittal images. The glenoid cartilage was measured in the axial and oblique coronal images. Results: At an average period of 5 years, 12 of 28 shoulders (42%) showed more than a 30% decrease in cartilage thickness in the humeral head. The glenoid showed cartilage thinning in only one shoulder (4%). In the humeral head, progressive cartilage thinning was seen mainly in the anterior and posterior parts of the humeral head in the sagittal plane. In the glenoid, progressive cartilage thinning was seen on the entire surface except the posterior area. There was no significant difference in cartilage thickness between the first and final follow-ups for both the humeral head and the glenoid. Conclusions: A total of 12 of 28 shoulders (42%) showed more than a 30% decrease in cartilage thickness in the humeral head, which was mainly observed in the anterior and posterior areas of the humeral head.