Caroline Livan Anyi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Caroline Livan Anyi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andre Gebauer
Ludwig-Maximilians-University Munich Germany
1 shared publication Fauzan Ahmad
Universiti Teknologi Malaysia, Malaysia-Japan International Institute of Technology, Kuala Lumpur 54100, Malaysia
1 shared publicationHamzah Arof
University of Malaya, Department of Electrical Engineering, Faculty of Engineering, Kuala Lumpur 50603, Malaysia
1 shared publication- Jan Kodet
Czech Technical University in Prague, Brehova 7, 115 19 Prague, Czech Republic
1 shared publication - Jon-Paul. R. Wells
School of Physical and Chemical Sciences University of Canterbury PB4800 8140 Christchurch New Zealand
1 shared publication - Karl Ulrich Schreiber
Technical University of Munich
1 shared publication
Latest Publications
- Open Access
Rotation Sensing Lasers in General Relativity: Some Technical Notes and Current Advances
We review the current status of large ring laser gyroscopes having the potential to contribute to terrestrial measurements of general relativistic precessions. At this point in time, although these devices possess the raw sensitivity for such a measurement, they remain limited by long-term geometric instability, detection noise and imperfections in the physical models required to isolate geophysical effects. Furthermore, minute non-reciprocal biases provide a null-shift error and therefore no currently constructed laser system meets the requirement of absolute rotation rate sensing. Nevertheless, we are of the view that these are surmountable problems and the ability of ring laser gyroscopes to measure low frequency to DC signals has vastly increased in the last decade.
Open AccessRotation Sensing Lasers in General Relativity: Some Technical Notes and Current Advances
We review the current status of large ring laser gyroscopes having the potential to contribute to terrestrial measurements of general relativistic precessions. At this point in time, although these devices possess the raw sensitivity for such a measurement, they remain limited by long-term geometric instability, detection noise and imperfections in the physical models required to isolate geophysical effects. Furthermore, minute non-reciprocal biases provide a null-shift error and therefore no currently constructed laser system meets the requirement of absolute rotation rate sensing. Nevertheless, we are of the view that these are surmountable problems and the ability of ring laser gyroscopes to measure low frequency to DC signals has vastly increased in the last decade.
- 1 October 2016
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 55 (10) , 106112-6
High-power Q-switched erbium-ytterbium codoped fiber laser using multiwalled carbon nanotubes saturable absorber
Due to an enormous potential of pulsed lasers in applications such as manufacturing, metrology, environmental sensing, and biomedical diagnostics, a high-power and stable Q-switched erbium-ytterbium codoped double-clad fiber laser (EYDFL) incorporating of multiwall carbon nanotubes (MWCNTs) saturable absorber (SA) made based on polyvinyl alcohol (PVA) with a 3∶2 ratio is demonstrated. The SA was fabricated by mixing a dilute PVA solution with an MWCNTs homogeneous solution. Subsequently, the mixture was sonicated and centrifuged to produce a homogeneous suspension that was left to dry at room temperature to form the MWCNTs-PVA film. The SA was formed by inserting the film between a pair of FC/PC fiber connectors. Then, it was integrated into the EYDFL’s ring cavity, which uses a 5-m-long erbium-ytterbium codoped fiber (EYDF). The lasing threshold for the Q-switched EYDFL was at 330 mW. At the maximum available pump power of 900 mW, the proposed EYDFL produced Q-switched pulses with a repetition rate of 74.85 kHz, pulsewidth of ∼3.6 μs, and an average output power of about 5 mW. The maximum energy per pulse of ∼85 nJ was obtained at pump power of ∼700 mW with peak power of 21 mW.
- 1 October 2016
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 55 (10) , 106112-6
High-power Q-switched erbium-ytterbium codoped fiber laser using multiwalled carbon nanotubes saturable absorber
Due to an enormous potential of pulsed lasers in applications such as manufacturing, metrology, environmental sensing, and biomedical diagnostics, a high-power and stable Q-switched erbium-ytterbium codoped double-clad fiber laser (EYDFL) incorporating of multiwall carbon nanotubes (MWCNTs) saturable absorber (SA) made based on polyvinyl alcohol (PVA) with a 3∶2 ratio is demonstrated. The SA was fabricated by mixing a dilute PVA solution with an MWCNTs homogeneous solution. Subsequently, the mixture was sonicated and centrifuged to produce a homogeneous suspension that was left to dry at room temperature to form the MWCNTs-PVA film. The SA was formed by inserting the film between a pair of FC/PC fiber connectors. Then, it was integrated into the EYDFL’s ring cavity, which uses a 5-m-long erbium-ytterbium codoped fiber (EYDF). The lasing threshold for the Q-switched EYDFL was at 330 mW. At the maximum available pump power of 900 mW, the proposed EYDFL produced Q-switched pulses with a repetition rate of 74.85 kHz, pulsewidth of ∼3.6 μs, and an average output power of about 5 mW. The maximum energy per pulse of ∼85 nJ was obtained at pump power of ∼700 mW with peak power of 21 mW.