Toshiyuki Hayase
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Toshiyuki Hayase has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
- Kenichi Funamoto
Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
27 shared publications - Atsushi Shirai
Tohoku University
22 shared publications Atsushi Shirai
Institute of Fluid Science, Tohoku University, Sendai, 980-8577, Japan
9 shared publications- Kouji Nagata
Department of Mechanical Engineering and Science, Kyoto University, Kyoto 615-8540, Japan
9 shared publications Seiichi Sudo
Akita Prefectural University
7 shared publications- Makoto Ohta
Institute of Fluid Science, Tohoku University, Sendai, Japan
6 shared publications
Latest Publications
- Open Access
- 1 April 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (4) , 045105
Numerical analysis of hemodynamic changes and blood stagnation in the left ventricle by internal structures and torsional motion
It is generally believed that thrombus formation does not occur in the left ventricle (LV) because of the high speed of blood flow. However, the LV has complex internal structures such as trabeculae carneae (TC) and papillary muscles (PM) on its inner wall, which may cause blood stagnation resulting in thrombus formation. In this study, the effects of the TC, PM, and torsional motion on the hemodynamics in the LV were investigated by computational fluid dynamics (CFD) analyses. An LV model was reconstructed from magnetic resonance imaging, and the shape was modified to mimic TC and PM. Then, the CFD analyses of blood flow were performed using several different combinations of TC, PM, and torsional motion. As the results, the presence of TC decreased the time-averaged wall shear stress and increased the relative residence time (RRT) of a blood stagnation index at the apex of the LV model. The TC-induced blood stagnation was also confirmed by a transportation analysis of the passive scalar. These hemodynamic changes were attributed to the fact that TC blocked the large vortex structures generated during the diastole, thus preventing them from reaching the apex. Moreover, the PM only affected the hemodynamics in its immediate vicinity, and torsional motion caused irregular changes to the RRT level and distribution at the apex. Therefore, the complex internal structures and torsional motion of the LV could cause blood stagnation.
- 1 April 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (4) , 045105
Open AccessNumerical analysis of hemodynamic changes and blood stagnation in the left ventricle by internal structures and torsional motion
It is generally believed that thrombus formation does not occur in the left ventricle (LV) because of the high speed of blood flow. However, the LV has complex internal structures such as trabeculae carneae (TC) and papillary muscles (PM) on its inner wall, which may cause blood stagnation resulting in thrombus formation. In this study, the effects of the TC, PM, and torsional motion on the hemodynamics in the LV were investigated by computational fluid dynamics (CFD) analyses. An LV model was reconstructed from magnetic resonance imaging, and the shape was modified to mimic TC and PM. Then, the CFD analyses of blood flow were performed using several different combinations of TC, PM, and torsional motion. As the results, the presence of TC decreased the time-averaged wall shear stress and increased the relative residence time (RRT) of a blood stagnation index at the apex of the LV model. The TC-induced blood stagnation was also confirmed by a transportation analysis of the passive scalar. These hemodynamic changes were attributed to the fact that TC blocked the large vortex structures generated during the diastole, thus preventing them from reaching the apex. Moreover, the PM only affected the hemodynamics in its immediate vicinity, and torsional motion caused irregular changes to the RRT level and distribution at the apex. Therefore, the complex internal structures and torsional motion of the LV could cause blood stagnation.
- Open Access
- 29 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-14
Blood pressure estimation based on pulse rate variation in a certain period
Availability of daily continuous blood pressure (DCBP) has a strong impact to realization of healthy society. However, existing methods to obtain blood pressure of cuff type and cuff-less types utilizing correlation with pulse waveform, pulse transit time or pulse rate; or computation of circulation model are not suitable to obtain DCBP. Here we implemented a method based on a simple circulatory system model using pulse rate measurement to overcome the limitations, and showed that it provides appropriate estimation of DCBP. The present model consists of a circulatory dynamic system model and an inverse model of a circulatory control system with input of pulse rate and six model parameters representing standard pulse rate, elasticity of systemic arteries, peripheral vascular resistance, and characteristics of resistance and stroke volume control. Validity of the DCBP estimation method was examined by preliminary experiment for one subject in four days and that for four subjects in one day. DCBP estimation was performed with 24-hour pulse rate measurement by a wearable device and sphygmomanometer measurement for parameter determination and verification. Mean absolute errors in systolic/diastolic pressures were appropriate ones for preliminary experiments with 9.4/6.4 mmHg in four days and 7.3/5.9 mmHg in five subjects.
- 29 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-14
Open AccessBlood pressure estimation based on pulse rate variation in a certain period
Availability of daily continuous blood pressure (DCBP) has a strong impact to realization of healthy society. However, existing methods to obtain blood pressure of cuff type and cuff-less types utilizing correlation with pulse waveform, pulse transit time or pulse rate; or computation of circulation model are not suitable to obtain DCBP. Here we implemented a method based on a simple circulatory system model using pulse rate measurement to overcome the limitations, and showed that it provides appropriate estimation of DCBP. The present model consists of a circulatory dynamic system model and an inverse model of a circulatory control system with input of pulse rate and six model parameters representing standard pulse rate, elasticity of systemic arteries, peripheral vascular resistance, and characteristics of resistance and stroke volume control. Validity of the DCBP estimation method was examined by preliminary experiment for one subject in four days and that for four subjects in one day. DCBP estimation was performed with 24-hour pulse rate measurement by a wearable device and sphygmomanometer measurement for parameter determination and verification. Mean absolute errors in systolic/diastolic pressures were appropriate ones for preliminary experiments with 9.4/6.4 mmHg in four days and 7.3/5.9 mmHg in five subjects.
- 27 January 2020
- Published by Springer Nature in Metallurgical and Materials Transactions B
- Vol. 51 (2) , 581-588
Real-Time Estimation of Molten Steel Flow in Continuous Casting Mold
- 27 January 2020
- Published by Springer Nature in Metallurgical and Materials Transactions B
- Vol. 51 (2) , 581-588
Real-Time Estimation of Molten Steel Flow in Continuous Casting Mold
- Open Access
- 4 October 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (10) , 675
Viscosity Estimation of a Suspension with Rigid Spheres in Circular Microchannels Using Particle Tracking Velocimetry
Suspension flows are ubiquitous in industry and nature. Therefore, it is important to understand the rheological properties of a suspension. The key to understanding the mechanism of suspension rheology is considering changes in its microstructure. It is difficult to evaluate the influence of change in the microstructure on the rheological properties affected by the macroscopic flow field for non-colloidal particles. In this study, we propose a new method to evaluate the changes in both the microstructure and rheological properties of a suspension using particle tracking velocimetry (PTV) and a power-law fluid model. Dilute suspension (0.38%) flows with fluorescent particles in a microchannel with a circular cross section were measured under low Reynolds number conditions (Re ≈ 10−4). Furthermore, the distribution of suspended particles in the radial direction was obtained from the measured images. Based on the power-law index and dependence of relative viscosity on the shear rate, we observed that the non-Newtonian properties of the suspension showed shear-thinning. This method will be useful in revealing the relationship between microstructural changes in a suspension and its rheology.
- 4 October 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (10) , 675
Open AccessViscosity Estimation of a Suspension with Rigid Spheres in Circular Microchannels Using Particle Tracking Velocimetry
Suspension flows are ubiquitous in industry and nature. Therefore, it is important to understand the rheological properties of a suspension. The key to understanding the mechanism of suspension rheology is considering changes in its microstructure. It is difficult to evaluate the influence of change in the microstructure on the rheological properties affected by the macroscopic flow field for non-colloidal particles. In this study, we propose a new method to evaluate the changes in both the microstructure and rheological properties of a suspension using particle tracking velocimetry (PTV) and a power-law fluid model. Dilute suspension (0.38%) flows with fluorescent particles in a microchannel with a circular cross section were measured under low Reynolds number conditions (Re ≈ 10−4). Furthermore, the distribution of suspended particles in the radial direction was obtained from the measured images. Based on the power-law index and dependence of relative viscosity on the shear rate, we observed that the non-Newtonian properties of the suspension showed shear-thinning. This method will be useful in revealing the relationship between microstructural changes in a suspension and its rheology.
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Conference on Frontiers in Bioengineering
- Vol. 2018.29, 1C26
Fundamental Study of MR-Measurement-Integrated Simulation of Heart-Aorta-System
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Conference on Frontiers in Bioengineering
- Vol. 2018.29, 1C26
Fundamental Study of MR-Measurement-Integrated Simulation of Heart-Aorta-System
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Tohoku Branch
- Vol. 2018.53, 161-162
182 Elucidation of Mechanisms of FBG vital sensing by Ultrasonic-Measurement-Integrated simulation:
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Tohoku Branch
- Vol. 2018.53, 161-162
182 Elucidation of Mechanisms of FBG vital sensing by Ultrasonic-Measurement-Integrated simulation:
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 13 (2) , 17-00597
Numerical analysis of the effect of trabeculae carneae models on blood flow in a left ventricle model constructed from magnetic resonance images
Although the blood flow velocity in a left ventricle (LV) has been considered to be sufficiently fast to prevent thrombus formation, internal wall structures, such as trabeculae carneae (TC) and papillary muscle, recently received attention as possible causes of reduced near-wall blood flow. As a fundamental consideration of this problem, this study established a method for constructing an unsteady LV model from magnetic resonance (MR) images and investigated the effect of a few simplified TC structures on the blood flow in the model. The LV model at arbitrary time steps was constructed by deforming a computational mesh generated from MR images at a reference time step. The validity of the proposed construction scheme was confirmed by comparison with the configuration of an LV model extracted from MR images. Numerical analysis was performed for the unsteady blood flow in LV models with and without two simplified TC structures. The flow field in the model with the internal structure differed from that in the model without the internal structure near the wall, and flow separation caused by the internal structure decreased wall shear stress on the rear of the internal structure. The computational results provide fundamental information for the complex interaction between the internal structures and the blood flow in an LV.
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 13 (2) , 17-00597
Numerical analysis of the effect of trabeculae carneae models on blood flow in a left ventricle model constructed from magnetic resonance images
Although the blood flow velocity in a left ventricle (LV) has been considered to be sufficiently fast to prevent thrombus formation, internal wall structures, such as trabeculae carneae (TC) and papillary muscle, recently received attention as possible causes of reduced near-wall blood flow. As a fundamental consideration of this problem, this study established a method for constructing an unsteady LV model from magnetic resonance (MR) images and investigated the effect of a few simplified TC structures on the blood flow in the model. The LV model at arbitrary time steps was constructed by deforming a computational mesh generated from MR images at a reference time step. The validity of the proposed construction scheme was confirmed by comparison with the configuration of an LV model extracted from MR images. Numerical analysis was performed for the unsteady blood flow in LV models with and without two simplified TC structures. The flow field in the model with the internal structure differed from that in the model without the internal structure near the wall, and flow separation caused by the internal structure decreased wall shear stress on the rear of the internal structure. The computational results provide fundamental information for the complex interaction between the internal structures and the blood flow in an LV.
- Open Access
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 12 (4) , 17-00189
Effects of upstream bifurcation and bend on the blood flow in a cerebral aneurysm
Mechanisms of development, growth, and rupture of a cerebral aneurysm have been studied by computational fluid dynamics (CFD), calculating hemodynamic parameters, such as wall shear stress, oscillatory shear index (OSI), and relative residence time (RRT). It is well known that the upstream velocity profile and upstream vessel shape influence the computational results. However, few studies have dealt with cases involving a bifurcation upstream of a cerebral aneurysm. Furthermore, the fluid-dynamic effects of multiple structural elements of upstream vessel shape, such as a bifurcation and a bend, on the results of CFD remain unknown. The purpose of this study was to elucidate the fluid-dynamic effects of multiple structural elements of upstream vessel shape such as bifurcation and bend on blood flow and hemodynamic parameters inside an aneurysm. Computations were performed for blood flow in a cerebral aneurysm with upstream sequential elements of a bifurcation, a bend, and a straight section, using four models with different upstream boundaries, i.e., before the bifurcation, after the bifurcation before the bend, after the bend, and after the straight section just before the cerebral aneurysm. The results were compared to elucidate the effect of each upstream structural element on the blood flow and hemodynamic parameters in the cerebral aneurysm. Differences in OSI and RRT resulting from changes in the velocity distribution were observed locally in the aneurysm between the models. It was also found that the effect of the bifurcation on the velocity distribution was greater than that of the bend.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 12 (4) , 17-00189
Open AccessEffects of upstream bifurcation and bend on the blood flow in a cerebral aneurysm
Mechanisms of development, growth, and rupture of a cerebral aneurysm have been studied by computational fluid dynamics (CFD), calculating hemodynamic parameters, such as wall shear stress, oscillatory shear index (OSI), and relative residence time (RRT). It is well known that the upstream velocity profile and upstream vessel shape influence the computational results. However, few studies have dealt with cases involving a bifurcation upstream of a cerebral aneurysm. Furthermore, the fluid-dynamic effects of multiple structural elements of upstream vessel shape, such as a bifurcation and a bend, on the results of CFD remain unknown. The purpose of this study was to elucidate the fluid-dynamic effects of multiple structural elements of upstream vessel shape such as bifurcation and bend on blood flow and hemodynamic parameters inside an aneurysm. Computations were performed for blood flow in a cerebral aneurysm with upstream sequential elements of a bifurcation, a bend, and a straight section, using four models with different upstream boundaries, i.e., before the bifurcation, after the bifurcation before the bend, after the bend, and after the straight section just before the cerebral aneurysm. The results were compared to elucidate the effect of each upstream structural element on the blood flow and hemodynamic parameters in the cerebral aneurysm. Differences in OSI and RRT resulting from changes in the velocity distribution were observed locally in the aneurysm between the models. It was also found that the effect of the bifurcation on the velocity distribution was greater than that of the bend.
- Open Access
- 27 July 2016
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (5) , 719-731
Photoplethysmography and ultrasonic-measurement-integrated simulation to clarify the relation between two-dimensional unsteady blood flow field and forward and backward waves in a carotid artery
Understanding the spatiotemporal change in hemodynamics is essential for the basic research of atherosclerosis. The objective of this study was to establish a methodology to clarify the relation between a two-dimensional (2D) unsteady blood flow field and forward and backward propagating waves in a carotid artery. This study utilized photoplethysmography (PPG) for blood pressure measurement and two-dimensional ultrasonic-measurement-integrated (2D-UMI) simulation for flow field analysis. The validity of the methodology was confirmed in an experiment for a carotid artery of a healthy volunteer. Synchronization between the pressure measurement and flow field analysis was achieved with an error of <10 ms. A 2D unsteady blood flow field in the carotid artery was characterized in relation to forward and backward waves. 2D-UMI simulation reproduced the flow field in which the wall shear stress takes a maximum at the time of the backward wave superiority in the systolic phase, whereas 2D ordinary simulation failed to reproduce this feature because of poor reproducibility of velocity distribution. In conclusion, the proposed methodology using PPG and 2D-UMI simulation was shown to be a potential tool to clarify the relation between 2D unsteady blood flow field and the forward and backward waves in a carotid artery.
- 27 July 2016
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (5) , 719-731
Open AccessPhotoplethysmography and ultrasonic-measurement-integrated simulation to clarify the relation between two-dimensional unsteady blood flow field and forward and backward waves in a carotid artery
Understanding the spatiotemporal change in hemodynamics is essential for the basic research of atherosclerosis. The objective of this study was to establish a methodology to clarify the relation between a two-dimensional (2D) unsteady blood flow field and forward and backward propagating waves in a carotid artery. This study utilized photoplethysmography (PPG) for blood pressure measurement and two-dimensional ultrasonic-measurement-integrated (2D-UMI) simulation for flow field analysis. The validity of the methodology was confirmed in an experiment for a carotid artery of a healthy volunteer. Synchronization between the pressure measurement and flow field analysis was achieved with an error of <10 ms. A 2D unsteady blood flow field in the carotid artery was characterized in relation to forward and backward waves. 2D-UMI simulation reproduced the flow field in which the wall shear stress takes a maximum at the time of the backward wave superiority in the systolic phase, whereas 2D ordinary simulation failed to reproduce this feature because of poor reproducibility of velocity distribution. In conclusion, the proposed methodology using PPG and 2D-UMI simulation was shown to be a potential tool to clarify the relation between 2D unsteady blood flow field and the forward and backward waves in a carotid artery.
- 2 May 2016
- Published by ASME International in Journal of Fluids Engineering
- Vol. 138 (8) , 081103
Fluid Vibration Induced by High-Shear-Rate Flow in a T-Junction
For laminar flow in the side branch of a T-junction, periodic fluid vibrations occur with the Strouhal number independent of characteristic flow conditions. As the mechanics is unknown, an experiment was performed to establish the underlying cause in high-shear-rate flow. The fluid vibration appears along both the shearing separation layer and the boundary between two vortices immediately downstream of the side branch, where the shear rates are several orders larger than those further downstream. This vibration is caused by flow instability induced in two types of high-shear-rate flow confirming that is a universal phenomenon associated with the geometry of the T-junction.
- 2 May 2016
- Published by ASME International in Journal of Fluids Engineering
- Vol. 138 (8) , 081103
Fluid Vibration Induced by High-Shear-Rate Flow in a T-Junction
For laminar flow in the side branch of a T-junction, periodic fluid vibrations occur with the Strouhal number independent of characteristic flow conditions. As the mechanics is unknown, an experiment was performed to establish the underlying cause in high-shear-rate flow. The fluid vibration appears along both the shearing separation layer and the boundary between two vortices immediately downstream of the side branch, where the shear rates are several orders larger than those further downstream. This vibration is caused by flow instability induced in two types of high-shear-rate flow confirming that is a universal phenomenon associated with the geometry of the T-junction.