MÇMuharrem Erhan Çömlekoğlu

Muharrem Erhan Çömlekoğlu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Muharrem Erhan Çömlekoğlu has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of bur grit size on the marginal adaptation of glass ceramic restorations

    by Büşra Sümbül, Anas Omer Abdelbagi Mohamed, Muharrem Erhan Çömlekoğlu, Mine Dündar Çömlekoğlu

    Purpose: This in vitro study aimed to investigate the effect of different grit sizes of dental burs on the marginal adaptation of lithium‐reinforced glass–ceramic restorations. The objective was to determine if finishing with fine‐grit burs after initial preparation with coarser‐grit burs enhances the marginal adaptation of restorations produced using computer‐aided design and computer‐aided manufacturing (CAD‐CAM) technology. Materials and methods: Fifty impacted human molar teeth with intact enamel were extracted and divided into five groups ( n = 10 per group). For group 1, a neutral band chamfer bur (107 µm) was used, while for group 2, a black band bur (181 µm) was used. A green band bur (151 µm) was used for group 3. For group 4, preparation was done using a black band bur and finished with the red band bur (46 µm), while for group 5, a green band bur was used for preparation and finished with the red band bur. Three‐dimensional (3D) scans of the prepared teeth were obtained using an intraoral scanner (Virtuo Vivo, Dental Wings), and CAD software was used to design the crowns. The restorations were milled from lithium disilicate blocks (IPS e.max CAD, Ivoclar Vivadent) on a chairside milling machine (M10, Camcube). Marginal gap assessment on the buccal, mesial, palatal/lingual, and distal surfaces by a stereomicroscope at 20× magnification and with 840 LP/mm resolution was performed. The measurements were performed for 32 equidistant points per sample, totaling 1600 points. ImageJ software was used for the analysis. Additionally, scanning electron microscopy (SEM) was used on 10 samples for validation. Statistical analysis was conducted using the Kruskal–Wallis and Mann–Whitney U tests at the 0.05 significance level. Results: There was a statistically significant difference in marginal adaptation between the different groups, with groups 4 (Black–Red) and 5 (Green–Red) showing a better marginal fit ( p < 0.05). Within each group, no significant difference was observed between the buccal, mesial, distal, and palatal sides. Conclusion: Finishing tooth preparation with a fine‐grit red diamond bur after using coarser‐grit burs significantly enhances the marginal adaptation of glass–ceramic restorations produced by CAD‐CAM technology. This technique could lead to better clinical outcomes in patients treated with such restorations.

  • Open Access

    Impact of Different Substructure and Superstructure Materials on Bone Stress Distribution in All-on-4 Prosthetic Restorations

    by Ege Çolak, Erhan Çömlekoğlu, Mehmet Sonugelen, Makbule Heval Şahan

    Aim: This study aimed to examine whether different framework and superstructure materials in All-on-4 prosthetic restorations affect load distribution in peri-implant bone. Materials and Methods: Four implants were placed according to the All-on-4 concept, with distal implants angled at 30 degrees. Framework materials (cobalt-chromium alloy, titanium, PEEK, zirconia) and superstructure materials (composite, zirconia) created eight combinations. 3D models were designed using Rhinoceros 4.0 and VRMesh, then imported into Algor Fempro for finite element analysis. A 150N force was applied perpendicular to the occlusal surfaces of the left first molar and premolar. Results: The PEEK framework group showed the highest maximum principal stress values in the cortical bone near the applied force. The zirconia superstructure group exhibited lower maximum principal stress values than the composite group. Minimum principal stress was lower in the composite superstructure compared to the zirconia superstructure. For the cantilever section, the peak minimum principal stress values in the cortical bone were inversely proportional to the elastic modulus of the frameworks: PEEK > titanium > Cr-Co > zirconia. Conclusions: The PEEK framework and composite superstructure groups generated higher tensile forces in the cortical bone surrounding the implants. The highest compression values were observed in the PEEK framework, followed by titanium, Cr-Co, and zirconia. Greater stress accumulation was found in the cortical bone with the composite superstructure compared to the zirconia superstructure.

  • Clinical wear and quality assessment of monolithic and lithium disilicate layered zirconia restorations

    by Muharrem Erhan Çömlekoğlu, Firuzan Tekeroğlu, Mine Dündar Çömlekoğlu, Mutlu Özcan, L. Şebnem Türkün, Gamze Paken

    Background: Wear and quality assessments of translucent monolithic zirconia and CAD‐on® restorations were performed.Methods: Forty 3‐unit posterior fixed partial denture (FPD) in 18 patients (age:18–50 years) were made from translucent monolithic zirconia (tm) (Zenostar T) and zirconia‐frameworked, lithium disilicate layered (c) (CAD‐on), materials in a split‐mouth design. Restorations were digitally fabricated and their internal and marginal adaptations were measured before cementation followed by luting (Multilink Speed). Clinical evaluations were made by modified United States Public Health Service criteria at baseline, 6, 12, and 24‐months. Wear of the restorations and the antagonists were digitally evaluated after optical scanning of stone casts at 1st week and 24 m through a software (Cerec 4.4). Statistical analysis was made (analysis of variance, Shapiro‐Wilk, Friedman and Wilcoxon tests (SPSS 20)) at α = 0.05 significance level.Results: At 24 m, all restorations were clinically acceptable. Insignificant differences were found between tm and c restorations (P > 0.05). Mean internal and marginal adaptation of c restorations were significantly better (145 µm (premolar)‐174 µm (molar)) than tm (190 µm (premolar)‐207 µm (molar)) (P < 0.05). C restorations significantly caused more wear (0.3 ± 0.1 mm) than tm (0.1 ± 0.07 mm) on the antagonistic dentition (P < 0.05).Conclusions: Translucent monolithic zirconia restorations caused less wear and antagonist wear than CAD‐on restorations. CAD‐on restorations exhibited higher internal and marginal adaptation.


  • Detection of the hybrid layer biodegradation initiation factor with a scanning electron microscope

    by Gamze Paken, Muharrem Erhan Çömlekoğlu, Mehmet Sonugelen

    The purpose of this study was to elucidate the origin of initiation of hybrid layer biodegradation. Ninety caries‐free human third molars were divided into three surface groups: enamel, dentin, and NaOCl‐treated dentin. (n = 30/group) Each group was divided into three subgroups (n = 10/group) of luting resin materials with etch‐and‐rinse; self‐etch and self‐adhesive systems. Resin composite blocks and sticks were fabricated and adhered onto dentin and enamel surfaces. The bond strength values were evaluated with micro shear test and statistical analysis were made. On the other hand, teeth were sectioned with a slow‐speed saw into multiple beams. After thermocycling, samples were kept in 50% silver nitrate solution. Samples were analyzed with SEM in back‐scattered mode. According to the micro‐shear bond tests, higher bond strength values were observed in etch‐and‐rinse system. Bond strength values in self‐adhesive and etch‐and‐rinse groups were significantly higher than self‐etch groups in dentin surface and dentin surface treatment with NaOCl. Back‐scattered scanning electron microscope results showed that, different degradation mechanism was observed. The present study indicates that, due to the acid etching in dentin, collagen biodegradation was observed within the hybrid layer. On the enamel surfaces, resin degradation was related with resin monomers in adhesive systems.


  • The role of concentrated growth factor on implant stability: A preliminary study

    by B. Özveri Koyuncu, K. İçPınar Çelik, M. Özden Yüce, T. Günbay, M.E. Çömlekoğlu


  • Open Access

    In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment

    by Akın Aladağ, Didem Oğuz, Muharrem Erhan Çömlekoğlu, Ender Akan

    Aladağ A, et al. J Adv Prosthodont. 2019 Apr;11(2):120-127. https://doi.org/10.4047/jap.2019.11.2.120


  • Immediate definitive individualized abutments reduce peri-implant bone loss: a randomized controlled split-mouth study on 16 patients

    by M Erhan Çömlekoğlu, Nejat Nizam, Mine Dündar Çömlekoğlu

    This paper aims to observe peri-implant time-related vertical bone level and soft tissue changes with immediate, non-detached glass-ceramic (lithium-disilicate) individualized abutments and dis-/reconnections.


  • Open Access

    Factors Affecting the Final Colour of Laminate Veneers: Review

    by Ece Şengün, M. Erhan Çömlekoğlu, Gökhan Yilmaz

    Ön dişlerdeki renklenme, form bozukluğu, çapraşıklık, kırılmalar dental anlamda estetik sorunların başında gelmektedir. Koruyucu diş hekimliği kavramının önem kazanmasıyla birlikte son yıllarda diş dokularından, özellikle de mine dokusundan, çok daha az madde kaldırılarak estetik tedaviler yapılabilmektedir. Bu nedenle, daha ince hazırlanan seramik lamina venerlere gereksinim duyulmaktadır. Işık geçirgenliği yüksek seramik materyallerinden üretilen lamina venerlerin kalınlıkları azaldıkça, opaklıkları da azalır ve ışık geçirgenlikleri artar. Bu nedenle, altta bulunan dişin ve rezin simanların renk özellikleri daha çok ön plana çıkmaktadır. Lamina venerlerin estetik başarısı ve renk uyumu; kullanılan seramiğin tipi, ışık geçirgenliği, kalınlığı, alttaki dişin rengi, kullanılan rezin simanın rengi, ışık geçirgenliği ve kalınlığı, glazür tabakası gibi faktörlere bağlıdır. Dolayısı ile tedavi sürecinde bunların hepsi bir bütün olarak değerlendirilmelidir. Lamina vener yapılacak dişin renginin fazla koyu olması durumunda ise; alttaki rengi maskeleyebilmek için bu parametrelerde değişiklikler gerekebilmektedir. Bu derleme çalışmasında, seramik lamina venerlerin final rengine etki eden seramiklerin ışık geçirgenliği, rezin simanların ışık geçirgenliği ile rengi, alttaki dişin rengi, glazür işlemleri gibi faktörler incelenerek, lamina venerlerin rengini etkileyen faktörlerle ilgili yapılan çalışmaların sonuçları üzerinde durulmuştur.Discoloration, fractures, malformation are the major esthetic problems at anterior region. With the increasing popularity of minimal invasive dentistry, removal of tooth structure, especially enamel, has started to be reduced and these problems can be solved by less enamel preparation. For this reason, thinner laminate veneers are required. When the thickness of veneers with high translucency is decreased, opacity of ceramics is decreased and properties of abutment tooth and resin cement color become more important. Color matching and esthetic success of laminate veneers depend on ceramic type, translucency and thickness of ceramics, translucency and color of resin cements, cement thickness and glaze of ceramics. Therefore it should be evaluated as a whole unit during the treatment process. The parameters affecting the final color may be changed when the abutment tooth is too dark and its colour should be masked. In this review article, ceramics with high translucency and resin cements affecting the final color of laminate veneers have been described and the results of the studies on the factors that may affect the final color of laminate veneers have been reviewed.

  • Open Access

    SABİT PROTETİK RESTORASYONLARDA KULLANILAN GÜNCEL TASARIM VE ÜRETİM YÖNTEMLERİ

    by Burcu Kanat Ertürk, Mine Dündar Çömlekoğlu, Erhan Çömlekoğlu, Mehmet Ali Güngör

    SABİT PROTETİK RESTORASYONLARDA KULLANILAN GÜNCEL TASARIM VE ÜRETİM YÖNTEMLERİ