Karan Pratap Singh
Research Subjects
Karan Pratap Singh has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Vijay Laxmi Yadav
IIT BHU
4 shared publications Vineeta Gautam
Department of Chemical Engineering & Technology, IIT-BHU, Varanasi, Uttar Pradesh, 521005, India
3 shared publicationsAnchal Srivastava
Mahamana Innovative Technologies Welfare Society
2 shared publicationsVijay L. Yadav
Department of Chemical Engineering & Technology, IIT-BHU, Varanasi, Uttar Pradesh, 521005, India
1 shared publication- Vineeta Gautam
Department of Chemical Engineering & Technology, IIT (BHU), Varanasi 221005, U.P., India; Mahamana Innovative Technologies Welfare Society, Nawabganj, Bareilly 262406, U.P., India; Bineswar Brahma Engineering College, Chandrapara, Kokrajhar 783370, Assam, India
1 shared publication - Vineeta Gautam
Department of Chemical Engineering & Technology, IIT-BHU, Varanasi 221005, India
1 shared publication
Latest Publications
- 31 January 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (8) , 2173-2181
Polyaniline/MWCNTs/starch modified carbon paste electrode for non-enzymatic detection of cholesterol: application to real sample (cow milk)
Nanocomposite materials are potentially revolutionizing many technologies, including sensors. In this paper, we described the application of “PANI/MWCNTs/Starch” modified carbon paste electrode (PCS-CPE) as a simple and highly sensitive cholesterol sensor. This novel nano-composite material has integrated nano-morphology, where polyaniline could interact effectively with the additives; pi-pi stacking “MWCNTs,” and covalently bonded with starch. Specific binding sites (sugar chains), better electro-catalytic properties and fast electron transfer facilitated the oxidation of cholesterol. Fourier transform infrared spectra confirmed the interaction of cholesterol with the composite material. The sensing response of PCS was measured by cyclic voltammetry and chronoamperometry (0.1 M PBS-5 used as supporting electrolyte). As the amount of cholesterol increased in the test solution, cyclic voltammograms showed a rise of peak current (cathodic and anodic). Under the normal experimental conditions, the developed sensor exhibited wide linear dynamic range (0.032 to 5 mM) (upper limit is due to lack of solubility of cholesterol), high sensitivity (800 μAmM−1 cm−2), low detection limit (0.01 mM) and shorter response time (within 4–6 s). Analytical specificity, selectivity, and sensitivity during cholesterol estimation were compared with the response of some other analytes (ascorbic acid, glucose, l-dopa, urea and lactic acid). This novel sensor was successfully applied to estimate cholesterol in cow milk (used as a model real sample). The sensing platform is highly sensitive and shows a linear response towards cholesterol without using any additional redox mediator or enzyme, thus this material is extremely promising for the realization of a low-cost integrated cholesterol sensor device.
- 31 January 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (8) , 2173-2181
Polyaniline/MWCNTs/starch modified carbon paste electrode for non-enzymatic detection of cholesterol: application to real sample (cow milk)
Nanocomposite materials are potentially revolutionizing many technologies, including sensors. In this paper, we described the application of “PANI/MWCNTs/Starch” modified carbon paste electrode (PCS-CPE) as a simple and highly sensitive cholesterol sensor. This novel nano-composite material has integrated nano-morphology, where polyaniline could interact effectively with the additives; pi-pi stacking “MWCNTs,” and covalently bonded with starch. Specific binding sites (sugar chains), better electro-catalytic properties and fast electron transfer facilitated the oxidation of cholesterol. Fourier transform infrared spectra confirmed the interaction of cholesterol with the composite material. The sensing response of PCS was measured by cyclic voltammetry and chronoamperometry (0.1 M PBS-5 used as supporting electrolyte). As the amount of cholesterol increased in the test solution, cyclic voltammograms showed a rise of peak current (cathodic and anodic). Under the normal experimental conditions, the developed sensor exhibited wide linear dynamic range (0.032 to 5 mM) (upper limit is due to lack of solubility of cholesterol), high sensitivity (800 μAmM−1 cm−2), low detection limit (0.01 mM) and shorter response time (within 4–6 s). Analytical specificity, selectivity, and sensitivity during cholesterol estimation were compared with the response of some other analytes (ascorbic acid, glucose, l-dopa, urea and lactic acid). This novel sensor was successfully applied to estimate cholesterol in cow milk (used as a model real sample). The sensing platform is highly sensitive and shows a linear response towards cholesterol without using any additional redox mediator or enzyme, thus this material is extremely promising for the realization of a low-cost integrated cholesterol sensor device.
- 1 March 2016
- Published by Pleiades Publishing Ltd in Polymer Science, Series A
- Vol. 58 (2) , 206-219
Vibrational and gravimetric analysis of polyaniline/polysaccharide composite materials
- 1 March 2016
- Published by Pleiades Publishing Ltd in Polymer Science, Series A
- Vol. 58 (2) , 206-219
Vibrational and gravimetric analysis of polyaniline/polysaccharide composite materials
- 30 May 2015
- Published by Wiley in Polymer Composites
- Vol. 38 (3) , 496-506
Preparation and characterization of polyaniline, multiwall carbon nanotubes, and starch bionanocomposite material for potential bioanalytical applications
In this article, we are reporting the preparation and characterization of a multi‐component integrated nanocomposite material by the combination of a naturally occuring biocompatible biopolymer (Starch—a type of polysaccharide), functional conjugated synthetic polymer (Polyaniline “PANI”—a type of intrinsic conducting polymer) and nanosize tubular conducting template material (multiwalled carbon nanotubes “MWCNTs”—a type of carbonaceous nanotube structure). Comparative studies of the four material systems viz. system‐1: PANI, system‐2: PANI/MWCNTs, system‐3: PANI/Starch, and system‐4: PANI/MWCNTs/Starch have been carried out to understand the physical and chemical characteristics by using following instrumental techniques; UV‐Visible spectroscopy, fourier infrared spectroscopy, Raman, X‐ray diffraction, scanning electron microscopy, transmission electron microscopy, BET‐surface area, conductivity, thermal gravimetric analysis, differential scanning calorimetry, and cyclic voltammetry. Proposed nanocomposite material, PANI/MWCNTs/Starch has nanosized integrated porous morphology (∼200–300 nm) with interconnected architecture, while simultaneously having good conductivity and better electroactivity. Moreover, the presence of hydroxyl functionality empowers it with good dispersion ability which is further supported by good biodegradability and biocompatibility. These properties together attest the proposed system for promising applications in biosensors and screen printed electrode ink formulation. POLYM. COMPOS., 38:496–506, 2017. © 2015 Society of Plastics Engineers
- 30 May 2015
- Published by Wiley in Polymer Composites
- Vol. 38 (3) , 496-506
Preparation and characterization of polyaniline, multiwall carbon nanotubes, and starch bionanocomposite material for potential bioanalytical applications
In this article, we are reporting the preparation and characterization of a multi‐component integrated nanocomposite material by the combination of a naturally occuring biocompatible biopolymer (Starch—a type of polysaccharide), functional conjugated synthetic polymer (Polyaniline “PANI”—a type of intrinsic conducting polymer) and nanosize tubular conducting template material (multiwalled carbon nanotubes “MWCNTs”—a type of carbonaceous nanotube structure). Comparative studies of the four material systems viz. system‐1: PANI, system‐2: PANI/MWCNTs, system‐3: PANI/Starch, and system‐4: PANI/MWCNTs/Starch have been carried out to understand the physical and chemical characteristics by using following instrumental techniques; UV‐Visible spectroscopy, fourier infrared spectroscopy, Raman, X‐ray diffraction, scanning electron microscopy, transmission electron microscopy, BET‐surface area, conductivity, thermal gravimetric analysis, differential scanning calorimetry, and cyclic voltammetry. Proposed nanocomposite material, PANI/MWCNTs/Starch has nanosized integrated porous morphology (∼200–300 nm) with interconnected architecture, while simultaneously having good conductivity and better electroactivity. Moreover, the presence of hydroxyl functionality empowers it with good dispersion ability which is further supported by good biodegradability and biocompatibility. These properties together attest the proposed system for promising applications in biosensors and screen printed electrode ink formulation. POLYM. COMPOS., 38:496–506, 2017. © 2015 Society of Plastics Engineers