Masaaki Sakamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masaaki Sakamoto has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Hitoshi Kubosawa
Department of Pathology, Chiba Municipal Aoba Hospital, Japan
3 shared publicationsHitoshi Watanabe
Department of Orthopaedic Surgery, Chiba Municipal Aoba Hospital, Japan
2 shared publicationsAkiyoshi Saito
Department of Orthopaedic Surgery, School of Medicine, Nihon University
1 shared publication- Carla Sabus
Department of Physical Therapy and Rehabilitation Science, Tufts University, Medford, MA
1 shared publication Donna Fry
Emmanuel B. John
1 shared publicationGanbaatar Namuun
School of Health Technology, Health Science University of Mongolia
1 shared publication
Latest Publications
- Open Access
- 25 August 2020
- Published by Hindawi Limited in Case Reports in Orthopedics
- Vol. 2020, 1-4
Intramedullary Nail Fixation with Autologous Bone Marrow Transplantation in an Incomplete Atypical Femoral Fracture Patient: Use of Bone Marrow Extracted from the Hollow Reamer
The present report describes an incomplete atypical femoral fracture (AFF) patient who underwent simultaneous autogenous bone transplantation to the resected fracture region during intramedullary nail fixation. A 73-year-old female with a history of multiple myeloma had been undergoing treatment with intravenous drip injections of Zoledronic Acid. She was introduced to our department due to the left lateral thigh pain, with no trauma incidence. An anteroposterior radiograph showed a transverse thin fracture line with localized periosteal and endosteal thickening, which is compatible with subtrochanteric incomplete AFF. A biochemical investigation revealed the existence of severely suppressed bone turnover. She underwent intramedullary nail fixation for fear of a complete fracture. After the fixation, the cortical bone at the fracture region was excised as a wedge-shaped block, and bone marrow extracted from the hollow reamer was simultaneously transplanted to the resected fracture region. Histological examination showed few bone formation features at the fracture line in the excised lateral cortical bone. At 7 months after surgery, radiographs demonstrated complete bone repair, and no clinical problems were observed two years postoperatively. To the best of our knowledge, this is the first report in which autogenous bone marrow transplantation, noninvasive to the iliac crest, was performed in an incomplete AFF patient. We believe that this low invasive procedure can be a useful technique for AFF treatment.
- 25 August 2020
- Published by Hindawi Limited in Case Reports in Orthopedics
- Vol. 2020, 1-4
Open AccessIntramedullary Nail Fixation with Autologous Bone Marrow Transplantation in an Incomplete Atypical Femoral Fracture Patient: Use of Bone Marrow Extracted from the Hollow Reamer
The present report describes an incomplete atypical femoral fracture (AFF) patient who underwent simultaneous autogenous bone transplantation to the resected fracture region during intramedullary nail fixation. A 73-year-old female with a history of multiple myeloma had been undergoing treatment with intravenous drip injections of Zoledronic Acid. She was introduced to our department due to the left lateral thigh pain, with no trauma incidence. An anteroposterior radiograph showed a transverse thin fracture line with localized periosteal and endosteal thickening, which is compatible with subtrochanteric incomplete AFF. A biochemical investigation revealed the existence of severely suppressed bone turnover. She underwent intramedullary nail fixation for fear of a complete fracture. After the fixation, the cortical bone at the fracture region was excised as a wedge-shaped block, and bone marrow extracted from the hollow reamer was simultaneously transplanted to the resected fracture region. Histological examination showed few bone formation features at the fracture line in the excised lateral cortical bone. At 7 months after surgery, radiographs demonstrated complete bone repair, and no clinical problems were observed two years postoperatively. To the best of our knowledge, this is the first report in which autogenous bone marrow transplantation, noninvasive to the iliac crest, was performed in an incomplete AFF patient. We believe that this low invasive procedure can be a useful technique for AFF treatment.
- Open Access
- 1 May 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 859-868
Identification of eyes at risk of acute primary angle-closure in elderly Japanese patients
Purpose: To identify from the anterior segment the structural variables of the eyes that can be used to distinguish acute primary angle-closure (APAC) eyes or primary angle-closure suspect (PACS) eyes from normal eyes. Patients and methods: We used a Pentacam scanner to measure participants’ anterior eye segments. We assessed each anterior segment structure variable on the basis of receiver operating characteristic curves using the area under the curve (AUC). Results: AUCs for eyes in men with APAC were 1.000 for central anterior chamber depth (ACD), 0.982 for peripheral ACD, 0.916 for anterior chamber angle (ACA), and 0.992 for anterior chamber volume (ACV). AUCs for eyes in women with APAC were 0.997 for central ACD, 0.942 for peripheral ACD, 0.922 for ACA, and 0.946 for ACV. AUCs for eyes in men with PACS were 0.933 for central ACD, 0.930 for peripheral ACD, 0.887 for ACA, and 0.937 for ACV. AUCs for eyes in women with PACS were 0.960 for central ACD, 0.957 for peripheral ACD, 0.937 for ACA, and 0.937 for ACV. The negative predictive values (%) in men with APAC were 100 for all the four variables (central ACD, peripheral ACD, ACA, and ACV). The negative predictive values (%) in women with APAC were 100 for central ACD, 98.7 for peripheral ACD, 97.1 for ACA, and 97.9 for ACV. The negative predictive values (%) in men with PACS were 98.6 for central ACD, 100 for peripheral ACD, 98.5 for ACA, and 99.4 for ACV. The negative predictive values (%) in women with PACS were 100 for central ACD, 98.7 for peripheral ACD, 97.1 for ACA, and 97.9 for ACV. Conclusions: The central ACD, peripheral ACD, ACA, and ACV measurements seem to be excellent markers to identify eyes without APAC or PACS.
- 1 May 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 859-868
Open AccessIdentification of eyes at risk of acute primary angle-closure in elderly Japanese patients
Purpose: To identify from the anterior segment the structural variables of the eyes that can be used to distinguish acute primary angle-closure (APAC) eyes or primary angle-closure suspect (PACS) eyes from normal eyes. Patients and methods: We used a Pentacam scanner to measure participants’ anterior eye segments. We assessed each anterior segment structure variable on the basis of receiver operating characteristic curves using the area under the curve (AUC). Results: AUCs for eyes in men with APAC were 1.000 for central anterior chamber depth (ACD), 0.982 for peripheral ACD, 0.916 for anterior chamber angle (ACA), and 0.992 for anterior chamber volume (ACV). AUCs for eyes in women with APAC were 0.997 for central ACD, 0.942 for peripheral ACD, 0.922 for ACA, and 0.946 for ACV. AUCs for eyes in men with PACS were 0.933 for central ACD, 0.930 for peripheral ACD, 0.887 for ACA, and 0.937 for ACV. AUCs for eyes in women with PACS were 0.960 for central ACD, 0.957 for peripheral ACD, 0.937 for ACA, and 0.937 for ACV. The negative predictive values (%) in men with APAC were 100 for all the four variables (central ACD, peripheral ACD, ACA, and ACV). The negative predictive values (%) in women with APAC were 100 for central ACD, 98.7 for peripheral ACD, 97.1 for ACA, and 97.9 for ACV. The negative predictive values (%) in men with PACS were 98.6 for central ACD, 100 for peripheral ACD, 98.5 for ACA, and 99.4 for ACV. The negative predictive values (%) in women with PACS were 100 for central ACD, 98.7 for peripheral ACD, 97.1 for ACA, and 97.9 for ACV. Conclusions: The central ACD, peripheral ACD, ACA, and ACV measurements seem to be excellent markers to identify eyes without APAC or PACS.
- Open Access
- 16 March 2016
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2016, 1-4
Unusual MRI Findings in a Polio Survivor
A 63-year-old male consulted our institution due to worsening of right hip pain for approximately one month. The patient had no apparent functional disorders besides rigidity of the right ankle secondary to childhood poliomyelitis. Plain radiographs demonstrated narrowing of the right hip joint space. Magnetic resonance imaging (MRI) showed unusual findings in the right gluteus medius muscle, suspecting a malignant musculoskeletal tumor. Further examinations clarified acute inflammation caused byStaphylococcus aureuswith no atypia. After treatment, serum inflammatory markers normalized and MRI showed homogeneous fat signal intensity in the muscle, which was consistent with poliomyelitis. Total hip arthroplasty was performed due to progression of osteoarthritis. Intraoperative findings showed flaccidity of the gluteus medius muscle, and histological examination of the specimen also was compatible with poliomyelitis. Postoperatively there was no hip instability and the patient has been able to resume his previous physical activity. To our knowledge, this is the first report regarding polio survivors combined with septic arthritis, and sole MRI examination was unable to lead to the diagnosis. The current patient demonstrates the possibility that the involved muscles in poliomyelitis exist even in asymptomatic regions, which will be helpful for accurate diagnosis and life guidance in polio survivors.
- 16 March 2016
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2016, 1-4
Open AccessUnusual MRI Findings in a Polio Survivor
A 63-year-old male consulted our institution due to worsening of right hip pain for approximately one month. The patient had no apparent functional disorders besides rigidity of the right ankle secondary to childhood poliomyelitis. Plain radiographs demonstrated narrowing of the right hip joint space. Magnetic resonance imaging (MRI) showed unusual findings in the right gluteus medius muscle, suspecting a malignant musculoskeletal tumor. Further examinations clarified acute inflammation caused byStaphylococcus aureuswith no atypia. After treatment, serum inflammatory markers normalized and MRI showed homogeneous fat signal intensity in the muscle, which was consistent with poliomyelitis. Total hip arthroplasty was performed due to progression of osteoarthritis. Intraoperative findings showed flaccidity of the gluteus medius muscle, and histological examination of the specimen also was compatible with poliomyelitis. Postoperatively there was no hip instability and the patient has been able to resume his previous physical activity. To our knowledge, this is the first report regarding polio survivors combined with septic arthritis, and sole MRI examination was unable to lead to the diagnosis. The current patient demonstrates the possibility that the involved muscles in poliomyelitis exist even in asymptomatic regions, which will be helpful for accurate diagnosis and life guidance in polio survivors.
- Open Access
- 4 March 2014
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2014, 1-4
Titanium Alloy Stem as a Cause for Adverse Reaction to Metal Debris after Bipolar Hemiarthroplasty
A 68-year-old male with failure of bipolar hemiarthroplasty consistent with adverse reaction to metal debris (ARMD) who presented with a painful cystic lesion and lower extremity swelling was encountered. However, revision surgical findings showed no apparent cause of ARMD previously described in the literature, such as corrosion at the head-neck junction and articular abrasion. Therefore, it was difficult to make a definite diagnosis of failure secondary to ARMD, which consequently led to the decision to perform two-stage revision procedure, though the stem was firmly fixed. Postoperative analysis in the retrieval tissues showed that the metal debris mainly originated from the titanium alloy stem itself. Although this is a very rare case, one should be aware that even the well-fixed femoral components themselves have the potential to be the cause of ARMD.
- 4 March 2014
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2014, 1-4
Open AccessTitanium Alloy Stem as a Cause for Adverse Reaction to Metal Debris after Bipolar Hemiarthroplasty
A 68-year-old male with failure of bipolar hemiarthroplasty consistent with adverse reaction to metal debris (ARMD) who presented with a painful cystic lesion and lower extremity swelling was encountered. However, revision surgical findings showed no apparent cause of ARMD previously described in the literature, such as corrosion at the head-neck junction and articular abrasion. Therefore, it was difficult to make a definite diagnosis of failure secondary to ARMD, which consequently led to the decision to perform two-stage revision procedure, though the stem was firmly fixed. Postoperative analysis in the retrieval tissues showed that the metal debris mainly originated from the titanium alloy stem itself. Although this is a very rare case, one should be aware that even the well-fixed femoral components themselves have the potential to be the cause of ARMD.
- Open Access
- 1 January 2012
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 24 (5) , 373-377
The Effect of Muscle Fatigue Using Short Term Transcutaneous Electrical Nerve Stimulation
Several studies found have that transcutaneous electrical nerve stimulation (TENS) is effective for reducing pain and improving physical function. But the influence of TENS on muscle fatigue is still unclear. The purpose of this study was to determine the influence of TENS on muscle fatigue. [Methods] The subjects were ten healthy males. To establish the muscle activity, subjects performed maximum isometric exertion 15 times and electromyography was recorded (TaskI). After this, subjects of the study group received TENS and subjects of the control group rested for 5 minutes. After the intervention each group again performed maximum isometric exertion as in Task1 (TaskII), and VAS and muscle elasticity were measured. [Results] We found that in the study group, the significant decrease in muscle activity during TaskII began later than in TaskI. Furthermore, we found that the fourth trial had a larger in muscle activity than that of the first trial in TaskI in both groups and TaskII of the study group. Conversely, In TaskII performed by the control group, we observed significant decreases. [Conclusions] From the result of this research, we believe that TENS electronically influenced the nervous system to prevent muscle fatigue.
- 1 January 2012
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 24 (5) , 373-377
Open AccessThe Effect of Muscle Fatigue Using Short Term Transcutaneous Electrical Nerve Stimulation
Several studies found have that transcutaneous electrical nerve stimulation (TENS) is effective for reducing pain and improving physical function. But the influence of TENS on muscle fatigue is still unclear. The purpose of this study was to determine the influence of TENS on muscle fatigue. [Methods] The subjects were ten healthy males. To establish the muscle activity, subjects performed maximum isometric exertion 15 times and electromyography was recorded (TaskI). After this, subjects of the study group received TENS and subjects of the control group rested for 5 minutes. After the intervention each group again performed maximum isometric exertion as in Task1 (TaskII), and VAS and muscle elasticity were measured. [Results] We found that in the study group, the significant decrease in muscle activity during TaskII began later than in TaskI. Furthermore, we found that the fourth trial had a larger in muscle activity than that of the first trial in TaskI in both groups and TaskII of the study group. Conversely, In TaskII performed by the control group, we observed significant decreases. [Conclusions] From the result of this research, we believe that TENS electronically influenced the nervous system to prevent muscle fatigue.
- 1 January 2012
- Published by Wolters Kluwer Health in Journal of Physical Therapy Education
- Vol. 26 (1) , 29-39
Establishing and Upgrading Physical Therapist Education in Developing Countries: Four Case Examples of Service by Japan and United States Physical Therapist Programs to Nigeria, Suriname, Mongolia, and Jordan
Background and Purpose. Physical therapist (PT) professional (entry-level) education programs are non-existent in most developing countries. The PT professional education programs that do exist in some developing countries may need to upgrade and strengthen their existing curricula. Many of these programs are in significant need of additional PT faculty and advanced education for their existing PT faculty. Efforts to create or enhance PT education programs in developing countries are frequently limited by inadequate human and material resources. Method/Model Description and Evaluation. This paper describes and discusses 4 models of collaboration and international partnerships in which educators and PT education programs in developed countries with more human and material resources partner with universities in developing countries to help establish or enhance PT education programs. Experiences of PT education programs in the US working with programs in Nigeria, Suriname, and Jordan, and a program in Japan working with a program in Mongolia, are presented. Outcomes. The models of collaboration between service and host countries resulted in provision of online education to practicing physical therapists, consultation on curriculum, short-term teaching/consulting for existing and developing programs, and PhD education of foreign PTs with the intention that they return to their country of origin as faculty members in PT programs. Discussion and Conclusion. These case examples of international collaboration serve as models for other PT programs and educators to form similar international partnerships and to develop new models.
- 1 January 2012
- Published by Wolters Kluwer Health in Journal of Physical Therapy Education
- Vol. 26 (1) , 29-39
Establishing and Upgrading Physical Therapist Education in Developing Countries: Four Case Examples of Service by Japan and United States Physical Therapist Programs to Nigeria, Suriname, Mongolia, and Jordan
Background and Purpose. Physical therapist (PT) professional (entry-level) education programs are non-existent in most developing countries. The PT professional education programs that do exist in some developing countries may need to upgrade and strengthen their existing curricula. Many of these programs are in significant need of additional PT faculty and advanced education for their existing PT faculty. Efforts to create or enhance PT education programs in developing countries are frequently limited by inadequate human and material resources. Method/Model Description and Evaluation. This paper describes and discusses 4 models of collaboration and international partnerships in which educators and PT education programs in developed countries with more human and material resources partner with universities in developing countries to help establish or enhance PT education programs. Experiences of PT education programs in the US working with programs in Nigeria, Suriname, and Jordan, and a program in Japan working with a program in Mongolia, are presented. Outcomes. The models of collaboration between service and host countries resulted in provision of online education to practicing physical therapists, consultation on curriculum, short-term teaching/consulting for existing and developing programs, and PhD education of foreign PTs with the intention that they return to their country of origin as faculty members in PT programs. Discussion and Conclusion. These case examples of international collaboration serve as models for other PT programs and educators to form similar international partnerships and to develop new models.
- Open Access
- 1 January 1994
- Published by Japan Society of Powder and Powder Metallurgy in Journal of the Japan Society of Powder and Powder Metallurgy
- Vol. 41 (3) , 335-339
Properties of the New Cu-Sn-P-Pb-Graphite Bearing Material with Steel Backing.
Sintered lead bronze alloys with steel backing have been widely used as the bearing material of wrapped type bushings, because of their high loading capability and wear resistance under the boundary lubrication. Small end bearings of connecting rods in the automotive engines are the typical application of these. As the recent automotive components are applied on severe conditions, such as higher load, higher temperature, newly advanced materials have been demanded for bearings having properties of higher loading capability, lower friction loss or better wear resistance. Authors have studied on a new sintered Cu-Sn-P-Pb-Graphite bearing material with steel backing for such demands as the above by carrying out the friction and wear tests with the bushing type test machine and also, by conducting the engine bench test for the small end bearing of connecting rod. Through these tests it was found that this Cu-Sn-P-Pb-Graphite material showed better friction and wear properties, compared with conventional lead bronze, due to the better alloy structural stability of the material itself against the high load under the high temperature and the solid lubricating effect of dispersed graphite in the material, at the condition of metalcontacting with the shaft.
- 1 January 1994
- Published by Japan Society of Powder and Powder Metallurgy in Journal of the Japan Society of Powder and Powder Metallurgy
- Vol. 41 (3) , 335-339
Open AccessProperties of the New Cu-Sn-P-Pb-Graphite Bearing Material with Steel Backing.
Sintered lead bronze alloys with steel backing have been widely used as the bearing material of wrapped type bushings, because of their high loading capability and wear resistance under the boundary lubrication. Small end bearings of connecting rods in the automotive engines are the typical application of these. As the recent automotive components are applied on severe conditions, such as higher load, higher temperature, newly advanced materials have been demanded for bearings having properties of higher loading capability, lower friction loss or better wear resistance. Authors have studied on a new sintered Cu-Sn-P-Pb-Graphite bearing material with steel backing for such demands as the above by carrying out the friction and wear tests with the bushing type test machine and also, by conducting the engine bench test for the small end bearing of connecting rod. Through these tests it was found that this Cu-Sn-P-Pb-Graphite material showed better friction and wear properties, compared with conventional lead bronze, due to the better alloy structural stability of the material itself against the high load under the high temperature and the solid lubricating effect of dispersed graphite in the material, at the condition of metalcontacting with the shaft.
- Open Access
- 1 January 1991
- Published by Society of Physical Therapy Science in Journal of exercise physiology
- Vol. 6 (3) , 165-169
Trunk Strength in Patients with Low Back Pain.
- 1 January 1991
- Published by Society of Physical Therapy Science in Journal of exercise physiology
- Vol. 6 (3) , 165-169
Open AccessTrunk Strength in Patients with Low Back Pain.