CTClément Tronche

Clément Tronche

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Clément Tronche has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Collimated beam formation in 3D acoustic sonic crystals

    by A L Vanel, M Dubois, C Tronche, S Fu, Y-T Wang, G Dupont, A D Rakić, K Bertling, R Abdeddaim, S Enoch, et al.

    We demonstrate strongly collimated beam formation, at audible frequencies, in a three-dimensional acoustic phononic crystal where the wavelength is commensurate with the crystal elements; the crystal is a seemingly simple rectangular cuboid constructed from closely-spaced spheres, and yet demonstrates rich wave phenomena acting as a canonical three-dimensional metamaterial. We employ theory, numerical simulation and experiments to design and interpret this collimated beam phenomenon and use a crystal consisting of a finite rectangular cuboid array of 4 × 10 × 10 polymer spheres 1.38 cm in diameter in air, arranged in a primitive cubic cell with the centre-to-centre spacing of the spheres, i.e. the pitch, as 1.5 cm. Collimation effects are observed in the time domain for chirps with central frequencies at 14.2 kHz and 18 kHz, and we deployed a laser feedback interferometer or Self-Mixing Interferometer – a recently proposed technique to observe complex acoustic fields—that enables experimental visualisation of the pressure field both within the crystal and outside of the crystal. Numerical exploration using a higher-order multi-scale finite element method designed for the rapid and detailed simulation of 3D wave physics further confirms these collimation effects and cross-validates with the experiments. Interpretation follows using High Frequency Homogenization and Bloch analysis whereby the different origin of the collimation at these two frequencies is revealed by markedly different isofrequency surfaces of the sonic crystal.


  • Open Access

    Demonstration of Pressure Wave Observation by Acousto-Optic Sensing Using a Self-Mixing Interferometer

    by Sébastien Maqueda, Julien Perchoux, Clément Tronche, José Javier Imas González, Marc Genetier, Maylis Lavayssière, Yohan Barbarin

    In this paper, we demonstrate that a compact and inexpensive interferometric sensor based on the self-mixing effect in the laser cavity can be used for the characterization of shock waves. The sensor measures the changes in the refractive index induced by the shock wave. It is based on the self-mixing interferometry scheme. We describe the architecture of the dynamic sensor and the design of the experimental setup used for the characterization that involves a shock tube. Thus, we detail the experimental measurements for shock wave pressure amplitude of 5 bar and address their interpretation with regard to the most admitted models for acousto-optics.


  • An embedded 2D imager for microscale flowmetry based on optical feedback interferometry

    by R. da Costa Moreira, A. Quotb, C. Tronche, F. Jayat, A. Luna-Arriaga, T. Bosch, J. Perchoux

    We present a compact and embedded imager based on the Optical Feedback Interferometry (OFI) sensing scheme that gives quantitative information about the velocity in fluids at micro-scale through the Doppler-Fizeau effect. This sensor can reach a spatial imaging resolution up to 5 μm in 2D scanning using a MEMS 2 axis beam-steering mirror. As an illustration of the imager performances, a 500 μm circular channel flow profile is measured. An image (300×50 pixels) of a 100 μm square section channel is successfully obtained thus validating the device.


  • Open Access

    Optical Feedback Interferometry for Velocity Measurement of Parallel Liquid-Liquid Flows in a Microchannel

    by Evelio E. Ramírez-Miquet, Julien Perchoux, Karine Loubière, Clément Tronche, Laurent Prat, Oscar Sotolongo-Costa

    Optical feedback interferometry (OFI) is a compact sensing technique with recent implementation for flow measurements in microchannels. We propose implementing OFI for the analysis at the microscale of multiphase flows starting with the case of parallel flows of two immiscible fluids. The velocity profiles in each phase were measured and the interface location estimated for several operating conditions. To the authors knowledge, this sensing technique is applied here for the first time to multiphase flows. Theoretical profiles issued from a model based on the Couette viscous flow approximation reproduce fairly well the experimental results. The sensing system and the analysis presented here provide a new tool for studying more complex interactions between immiscible fluids (such as liquid droplets flowing in a microchannel).


  • Optical Feedback Interferometry sensor for flow characterization inside ex-vivo vessel

    by Adam Quotb, Evelio E. Ramirez-Miquet, Clement Tronche, Julien Perchoux

    Pressure myograph systems allow the study of pharmacological effects of drugs and other vasoactive compounds on small isolated vessels by image processing. In this work, we present a new pressure myograph system based on Optical Feedback Interferometry (OFI) sensor that gives information about local velocity in fluids and enables reconstruction of a velocity profile inside a vessel. OFI is a self-aligned interferometric technique that uses the laser as both the light source and the receiver thus offering high sensitivity, fast response, and a simple and compact optical design. The local Doppler flow velocity is directly measured inside ex-vivo rat vessel with a step of 100 μm thus avoiding the need to use complex image processing and models based profile calculation for extracting flow velocity. This technique will be useful to investigate hemodynamics in microcirculation by measuring unsteady irregular blood.