MLMorten Enemark Lund

Morten Enemark Lund

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Morten Enemark Lund has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Extending Musculoskeletal Modelling Validation Beyond Gait: Knee Loading and Kinematics During Daily Activities

    by Enrico De Pieri, Sara C. Sarabadani Tafreshi, Sabrina Hörmann, Morten E. Lund, Philipp Damm, Pascal Schütz, William R. Taylor, Marc Bandi, Jörn Seebeck

    Musculoskeletal (MSK) modelling enables non-invasive estimation of internal body loads, which could inform the design of novel orthopedic implants and guide personalized treatment strategies. Extensive validation is a pre-requisite for the translation of MSK-modelling frameworks into clinical applications. This study validates predicted knee loads and local kinematics across multiple activities of daily living (ADLs) using motion-capture data from 184 activity cycles collected in six subjects performing five ADLs from the CAMS-Knee datasets. Personalized models incorporated subject-specific anthropometric, radiographic, and implantation data, along with a 6-DOF elastic-foundation contact model between implant components and a surgically balanced ligament model derived from cadaveric testing. Across activities, predicted knee contact force magnitudes showed good agreement with instrumented implant measurements (RMSE 0.46 BW; R² = 0.81). The highest accuracy was found during level walking, whereas stair descent exhibited the largest discrepancies. Predicted implant kinematics showed qualitatively similar trends to fluoroscopic measurements across all ADLs, although with varying levels of accuracy across different degrees of freedom. EMG comparisons revealed broadly consistent activation timing between model predictions and experimental data, although gastrocnemius activation was poorly estimated during stair descent and downhill walking. By validating MSK model predictions across the complete range of activities available in the CAMS- Knee datasets, this study extends validation beyond previously analysed gait or bending tasks and reveals activity-specific discrepancies that reflect current limitations in modelling assumptions and would remain undetected in single-activity analyses. These findings provide a robust basis for future refinement of MSK models and support their development toward clinically meaningful applications.

  • Open Access

    Motion capture dataset of 137 post-operative total hip replacement patients performing activities of daily living

    by David E. Lunn, Enrico De Pieri, Graham J. Chapman, Morten E. Lund, Stephen J. Ferguson, Anthony C. Redmond

    Three-dimensional motion capture is a powerful tool in clinical and engineering applications, but it can be time consuming, expensive, and difficult to access patient populations. Here, we present an open-access dataset comprising 3D motion capture and ground reaction force data from 137 post-operative total hip replacement patients performing eight activities of daily living (ADLs): normal walking, fast walking, stair ascent, stair descent, sit-to-stand, stand-to-sit, lunge, and squat. Data were collected using a 10-camera Vicon system and two AMTI force plates, and are provided in C3D and txt file format, compatible with inverse dynamic analysis platforms (e.g Visual 3D, MOKKA) and musculoskeletal modelling platforms (e.g. OpenSim, AnyBody). Each file includes synchronised marker trajectories, analog force data, and participant metadata (e.g. age, sex, BMI, operated limb, time since surgery). This dataset offers a unique opportunity to study functional biomechanics across a range of ADLs, enabling applications in musculoskeletal modelling, rehabilitation assessment, and the development of machine learning algorithms.


  • Open Access

    A generic detailed multibody model for simulating thoracic spine and ribcage kinematics

    by Hamed Shayestehpour, Søren Tørholm, Michael Damsgaard, Morten Enemark Lund, Christian Wong, John Rasmussen

    A reliable and comprehensive multibody musculoskeletal model of the thoracic spine and ribcage can offer valuable insight into the biomechanics of healthy and curved spines. In this study, we developed a generic rigid-body thoracic spine and ribcage model, which is kinematically determinate and controlled by spinal posture. A newly devised averaging constraint was implemented to model the kinematics of individual ribs and the sternum. Rib motion validation confirmed that the movement of adjacent ribs matched measured data across different tasks. We simulated 39 adolescent idiopathic scoliosis subjects aged 7–17 years, with an average (SD) Cobb angle of 15.9 (8.2) degrees. The average errors of multiple scoliosis metrics were less than 4 degrees for angle parameters, 5 mm for displacement parameters, and 3 percent for the ratio parameter. The model is straightforward and can simulate various daily activities (e.g., spinal articulation and breathing) while accurately capturing pathological deformities conforming to experimental data. It is available to the public on the open science platform Zenodo and will also be accessible through the AnyBody Managed Model Repository.


  • AnyPyTools

    by Morten Enemark Lund

  • The AnyBody Managed Model Repository (AMMR)

    by Morten Enemark Lund, Søren Tørholm, Sune Timm Simonsen, Bjørn Keller Engelund


  • The AnyBody Managed Model Repository (AMMR)

    by Morten Enemark Lund, Søren Tørholm, Sune Timm Simonsen, Bjørn Keller Engelund

  • Open Access

    AnyPyTools: A Python package for reproducible research with the AnyBody Modeling System

    by Morten Lund, John Rasmussen, Michael Andersen

    The AnyPyTools package provides a Python interface to automate multibody musculoskeletal model simulations in the AnyBody Modeling System. The main advantage of AnyPyTools is that it enables reproducible research for the AnyBody Modeling System, and bridges the gap to the whole ecosystem of open source scientific Python packages.


  • Open Access

    Effects of a semi-rigid ankle brace on ankle joint loading during landing on inclined surfaces

    by Ilias Theodorakos, Jan Rueterbories, Morten E. Lund, Eric Eils, Michael S. Andersen, Mark De Zee, Uwe G. Kersting

    Ankle bracing is commonly used to prevent ankle sprain occurrences. The present study investigated the effects of a semi-rigid ankle brace on the ankle joint complex during landing on inclined surfaces. Seventeen recreational athletes performed a single leg landing task onto three different surface alignments (everted, neutral, inverted), with and without the brace. Ground reaction forces (GRF), kinematics, and brace pressure were recorded. Six two-way repeated measures MANOVA tested for differences in GRF, talocrural and subtalar kinematics and kinetics. Participants landed with a significantly less plantar flexed (P < 0.001) and more everted (P = 0.001) foot during the braced condition. Although no differences were observed for the joint moments, an increased subtalar compression force (P = 0.009) was observed with the brace. Landing on the inverted surface resulted in significantly higher peak magnitudes of the vertical and the mediolateral GRF and the talocrural inversion moment compared to landing on the neutral surface. Ankle bracing altered ankle kinematics by restricting the ROM of the ankle joint complex. This study confirmed that landing on inverted surfaces may increase the risk for lateral ankle ligaments injuries. The significantly higher subtalar compression force during the brace condition might contribute to overuse injuries.


  • Open Access

    Development and functional demonstration of a wireless intraoral inductive tongue computer interface for severely disabled persons

    by Lotte N. S. Andreasen Struijk, Eugen R. Lontis, Michael Gaihede, Hector A. Caltenco, Morten Enemark Lund, Henrik Schioeler, Bo Bentsen

    Purpose: Individuals with tetraplegia depend on alternative interfaces in order to control computers and other electronic equipment. Current interfaces are often limited in the number of available control commands, and may compromise the social identity of an individual due to their undesirable appearance. The purpose of this study was to implement an alternative computer interface, which was fully embedded into the oral cavity and which provided multiple control commands. Methods: The development of a wireless, intraoral, inductive tongue computer was described. The interface encompassed a 10-key keypad area and a mouse pad area. This system was embedded wirelessly into the oral cavity of the user. The functionality of the system was demonstrated in two tetraplegic individuals and two able-bodied individuals Results: The system was invisible during use and allowed the user to type on a computer using either the keypad area or the mouse pad. The maximal typing rate was 1.8 s for repetitively typing a correct character with the keypad area and 1.4 s for repetitively typing a correct character with the mouse pad area. Conclusion: The results suggest that this inductive tongue computer interface provides an esthetically acceptable and functionally efficient environmental control for a severely disabled user.