JPJoel Politi

Joel Politi

*This is an algorithmically generated author record based on publicly available information.

Joel Politi has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty

    by Thomas J. Blumenfeld, Joel Politi, Sean Croker, Tammy O’dEll, William Hamilton


  • Repair of Medial Collateral Ligament Injury During Total Knee Arthoplasty

    by Scott Stephens, Joel Politi, Jeffrey Backes, Tony Czaplicki

    Intraoperative midsubstance lacerations of the medial collateral ligament (MCL) must be addressed during surgery, and failure to obtain coronal plane stability could affect patient outcomes and satisfaction. This article reports our results of a series of patients who sustained an intraoperative MCL injury during a primary total knee arthroplasty and were treated by direct primary repair and no change in implant constraint or postoperative protocol. Over a 5-year period, 9 patients sustained this complication. We reviewed their subjective satisfaction and stability, as well as objective measures such as functional scores, physical examinations, and radiographs. Average patient age was 58 years, and mean patient body mass index was 43.3. All patients were satisfied with the procedure and demonstrated no instability on physical examination. Average Knee Society pain score was 91.5 and functional score was 73.3. No radiographic changes or signs of loosening were noted. This novel approach for intraoperative midsubstance lacerations of the MCL does not involve altering implants or postoperative protocols and has encouraging results.


  • Evaluation of Postoperative Fever and Leukocytosis in Patients After Total Hip and Knee Arthroplasty

    by Anthony P. Czaplicki, Jennifer E. Borger, Joel R. Politi, Bryan T. Chambers, Benjamin C. Taylor


    • 1 December 2011
      • Vol. 21, 199-203

    Evaluation of Primary Total Knee Arthroplasty Incision Closure with the Use of Continuous Bidirectional Barbed Suture.

    by Scott Stephens, Joel Politi, Ben C Taylor

    The purpose of this study is to determine whether operative time for primary total knee arthroplasty can be decreased with the use of a continuous barbed suture. Five hundred patients were retrospectively reviewed and divided into groups based on whether incision closure utilized a continuous barbed suture or an interrupted biodegradable suture. We identified additional variables to determine their relationship to operative time, including body mass index, age, gender, and side of replacement. The results demonstrated a decrease in operative time by an average of 4 minutes (P < .001) with the use of barbed suture, without an associated increase in complications. Statistically significant relationships were found between operative time and variables such as body mass index, age, and gender, but not side of replacement.


  • The Incidence of Femoral Component Version Change in Primary THA Using the S-ROM Femoral Component

    by Kirk A. Kindsfater, Joel R. Politi, Douglas A. Dennis, Christi J. Sychterz Terefenko

    Although use of modular femoral components in revision total hip arthroplasty (THA) is widely accepted, many still question the need for modular versatility in primary THA. This study examined a large cohort of primary THA patients implanted with a modular S-ROM femoral component (DePuy Orthopaedics, Warsaw, Indiana) to determine the percentage of hips in which the surgeon changed version of the femoral component to increase the intraoperative stability of the THA construct and/or to maximize hip range of motion without impingement. In a group of 1000 routine, primary THAs, femoral component version was changed in 479 hips (47.9%). This change in rotational position of the femoral stem ranged from 60° retroversion with respect to the position of the sleeve to 80° of anteversion with respect to the sleeve. Ten hips (1%) experienced dislocation within the first 3 postoperative months. There was no difference in the dislocation rate between those patients in which femoral component version was changed versus those in which version was not changed. Statistical analysis showed no correlation between the likelihood of changing stem version and any of the following clinical variables: patient age, sex, diagnosis, or surgeon. The high percentage of straightforward primary THAs in which it was deemed beneficial to change version of the stem combined with the lack of correlation between femoral version change and clinical variables leads us to conclude that the routine use of a stem that allows variable version may be advantageous when compared to a nonmodular stem, as it is not possible to preoperatively determine when changing version will be required.


  • Erratum to: THA With Delta Ceramic on Ceramic: Results of a Multicenter Investigational Device Exemption Trial

    by William G. Hamilton, James P. McAuley, Douglas A. Dennis, Jeffrey A. Murphy, Thomas J. Blumenfeld, Joel Politi

    The captions for Figs. 2 and 4 for this article parenthetically refer to arrows that are not present in the figures. The incorrect caption for Fig. 2 is: Fig. 2 Anteroposterior radiograph demonstrates fragmentation of the ceramic liner (arrow). The correct caption is: Fig. 2 Anteroposterior radiograph demonstrates fragmentation of the ceramic liner. The incorrect caption for Fig. 4 is: Fig. 4 Anteroposterior radiograph of a patient with a chipped ceramic liner. A small ceramic fragment (arrow) can be visualized. The correct caption is: Fig. 4 Anteroposterior radiograph of a patient with a chipped ceramic liner. A small ceramic fragment can be visualized. Fig. 3 incorrectly shows a picture of a 36-mm diameter head and chipped liner from a patient in a different study. A picture of the correct 28-mm diameter head and chipped liner is provided. Fig. 3The retrieved liner and head show the fractured rim of the liner and ceramic fragments

  • THA With Delta Ceramic on Ceramic: Results of a Multicenter Investigational Device Exemption Trial

    by William G. Hamilton, James P. McAuley, Douglas A. Dennis, Jeffrey A. Murphy, Thomas J. Blumenfeld, Joel Politi

    Although the published studies on the outcomes of total hip arthroplasty (THA) performed with currently available ceramic components show high survivorship and low bearing wear at midterm followup, concern over ceramic fracture and squeaking persist. For these reasons, the use of ceramic is limited. Recently, a new alumina matrix composite material (Delta ceramic) with improved material properties was developed to address these concerns. We report the early outcomes and complications of a prospective, randomized, multicenter trial of 263 patients (264 hips) at eight centers, comparing a Delta ceramic-on-ceramic (COC) articulation with a Delta ceramic head-crosslinked polyethylene bearing combination (COP). There were 177 COC hips and 87 COP hips. Complications were reported for all patients, whereas clinical and radiographic results were provided for the 233 patients with minimum 2-year followup (average, 31.2 months; range, 21–49 months). The Harris hip scores and clinical, radiographic, and survivorship outcomes were similar in both groups. There were four (2%) revisions in the COC group and two (2%) in the COP group. We encountered three intraoperative ceramic liner-related events. In addition, one patient receiving the COC underwent revision for chipping of the ceramic liner, and a second had ceramic fragmentation on followup radiographs but has not undergone revision. These liner related complications remain a concern. No patient reported squeaking in either group; this leaves us hopeful the new material will lessen the frequency of squeaking. In the short term, the Delta COC articulation provided similar functional scores and survivorship and complication rates with the ceramic head mated with crosslinked polyethylene. Level of Evidence: Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


  • AAHKT Supplement

    by Hari P. Bezwada, Michael P. Bolognesi, Michael N. Kang, Raymond H. Kim, Robert A. Malinzak, Michael R. O'Rourke, Joel R. Politi, William C. Schroer

  • S-ROM Hip Prosthesis: 10- to 14-Year Results

    by Damon C. Adamany, Joel R. Politi, Walter H. Hauser

    This retrospective study evaluated the results of 55 S-ROM femoral components (45 patients) at 10 to 14 years postoperatively. Twelve patients (15 hips) were lost to follow-up. Survivorship of the prosthesis was determined in the remaining 33 patients (40 hips). Harris hip scores and radiographic analyses were performed. Thirty-four hips were performed in a primary fashion and 6 for revision arthroplasty. There was 100% survival for aseptic loosening in the primary arthroplasty group and 1 failure in the revision group. This study shows excellent long-term results of the S-ROM prosthesis at 10 to 14 years.