Walid Chakroun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Walid Chakroun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Nesreen Ghaddar
Department of Mechanical Engineering, American University of Beirut, Beirut 1107 2020, Lebanon
4 shared publications Kamel Ghali
Mechanical Engineering Department, American University of Beirut, Beirut, Lebanon
3 shared publicationsSorour Alotaibi
2 shared publications- Sorour Alotaibi
Mechanical Engineering Department, College of Engineering and Petroleum, Kuwait University, P.O. Box 5969, Safat 13060, Kuwait
2 shared publications Carine Habchi
1 shared publication- Carlos Fernández-Peruchena
Mathematics PhD at National Renewable Energy Centre (CENER), Paseo de la Innovación 7, 31621 Sarriguren, Spain. Tel.: (+34) 948 25 28 00
1 shared publication
Latest Publications
- Open Access
- 20 December 2025
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 29
Investigation of Flexible Power Plants with Pressurized Water Reactor: Thermodynamic and Energy Transfer Analyses
- 20 December 2025
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 29
Open AccessInvestigation of Flexible Power Plants with Pressurized Water Reactor: Thermodynamic and Energy Transfer Analyses
- 11 March 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (7) , 807-822
Ventilation increase using radiative cooling and phase change material at no additional energy cost in high ambient temperature countries
In this work, a passive system composed of a radiative cooling (RC) panel combined with two phase change material (PCM) storage tanks was integrated with a conventional air conditioning (AC) system to minimize energy consumption of cooling the high temperature fresh air in the hot climate like Kuwait. The cooling power produced by the RC panel was used to charge the PCM storage tanks. One of these tanks was used for precooling the supplied fresh air (tank 1) and another for enhancing the coefficient of performance (COP) of the AC system by cooling the ambient air entering the condenser (tank 2). A mathematical model was developed for the proposed system and simulations were conducted for a typical Kuwaiti residence for the entire summer season extending from April to October. It was found that tank 1 resulted in an increase in the fresh air intake at zero energy expenses from 30 l/s/person to 190 l/s/person, with no required ventilation load from the AC system. Furthermore, tank 2 enhanced the COP by 10.5%. Thus, the overall energy consumption of the AC system was reduced by 22.3% with respect to the conventional AC system.
- 11 March 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (7) , 807-822
Ventilation increase using radiative cooling and phase change material at no additional energy cost in high ambient temperature countries
In this work, a passive system composed of a radiative cooling (RC) panel combined with two phase change material (PCM) storage tanks was integrated with a conventional air conditioning (AC) system to minimize energy consumption of cooling the high temperature fresh air in the hot climate like Kuwait. The cooling power produced by the RC panel was used to charge the PCM storage tanks. One of these tanks was used for precooling the supplied fresh air (tank 1) and another for enhancing the coefficient of performance (COP) of the AC system by cooling the ambient air entering the condenser (tank 2). A mathematical model was developed for the proposed system and simulations were conducted for a typical Kuwaiti residence for the entire summer season extending from April to October. It was found that tank 1 resulted in an increase in the fresh air intake at zero energy expenses from 30 l/s/person to 190 l/s/person, with no required ventilation load from the AC system. Furthermore, tank 2 enhanced the COP by 10.5%. Thus, the overall energy consumption of the AC system was reduced by 22.3% with respect to the conventional AC system.
- 15 February 2022
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (4)
Performance Assessment of Seawater, Wet and Dry Cooling in a 50-MW Parabolic Trough Collectors Concentrated Solar Power Plant in Kuwait
Kuwait is a country with great potential for concentrated solar power (CSP) due to its high solar resource. The current work analyzes the potential of the application of CSP technology in the country and its particularities. Specifically, the current work examines a CSP plant with parabolic trough collector (PTC) technology and how this technology is affected in its performance depending on the location (inland or coastal) and the refrigeration system (wet, dry, or seawater cooled). The modeling methodology is based on a two-step approach: first, the Rankine steam power cycle is modeled in detail in a state-of-the-art steady-state simulation environment, obtaining the performance of the power cycle for each cooling technology; second, the power cycle performance maps are integrated into a detailed transient system-level simulation model of the complete CSP plant in order to perform annual yield simulations for the different representative locations of the climate of Kuwait. These results provide valuable information on both the potential of this technology for its more immediate application such as electricity generation and other future applications such as the desalination of seawater where the location must necessarily be coastal.
- 15 February 2022
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (4)
Performance Assessment of Seawater, Wet and Dry Cooling in a 50-MW Parabolic Trough Collectors Concentrated Solar Power Plant in Kuwait
Kuwait is a country with great potential for concentrated solar power (CSP) due to its high solar resource. The current work analyzes the potential of the application of CSP technology in the country and its particularities. Specifically, the current work examines a CSP plant with parabolic trough collector (PTC) technology and how this technology is affected in its performance depending on the location (inland or coastal) and the refrigeration system (wet, dry, or seawater cooled). The modeling methodology is based on a two-step approach: first, the Rankine steam power cycle is modeled in detail in a state-of-the-art steady-state simulation environment, obtaining the performance of the power cycle for each cooling technology; second, the power cycle performance maps are integrated into a detailed transient system-level simulation model of the complete CSP plant in order to perform annual yield simulations for the different representative locations of the climate of Kuwait. These results provide valuable information on both the potential of this technology for its more immediate application such as electricity generation and other future applications such as the desalination of seawater where the location must necessarily be coastal.
- 1 May 2019
- Published by Elsevier in Building and Environment
- Vol. 155, 118-126
Comparison of removal effectiveness of mixed versus displacement ventilation during vacuuming session
- 1 May 2019
- Published by Elsevier in Building and Environment
- Vol. 155, 118-126
Comparison of removal effectiveness of mixed versus displacement ventilation during vacuuming session
- 1 October 2016
- Published by Elsevier in Building and Environment
- Vol. 107, 29-42
The effect of PCM placement on torso cooling vest for an active human in hot environment
- 1 October 2016
- Published by Elsevier in Building and Environment
- Vol. 107, 29-42
The effect of PCM placement on torso cooling vest for an active human in hot environment
- 1 October 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (10) , 2684-2695
Air quality in rooms conditioned by chilled ceiling and mixed displacement ventilation for energy saving
- 1 October 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (10) , 2684-2695
Air quality in rooms conditioned by chilled ceiling and mixed displacement ventilation for energy saving
- 1 March 2005
- Published by Elsevier in Desalination
- Vol. 173 (1) , 13-24
A reverse osmosis desalting plant operated by gas turbines
- 1 March 2005
- Published by Elsevier in Desalination
- Vol. 173 (1) , 13-24
A reverse osmosis desalting plant operated by gas turbines