Antonio Gustavo González
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Antonio Gustavo González has a total of 152 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Pablos
Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, 41012 Seville, Spain
18 shared publications - María Jesús Martín
University of Seville
17 shared publications - Antonio Castellanos
Faculty of Physics, University of Seville, Avda. Reina Mercedes s/n, 41012 Seville, Spain
16 shared publications - Ana Maria Cameán
Area of Toxicology, Faculty of Pharmacy, University of Sevilla, Spain
15 shared publications - M. Angeles Herrador
University of Seville
15 shared publications - Antonio Ramos
Universidad de Sevilla
14 shared publications
Latest Publications
- Open Access
- 22 August 2018
- Published by IntechOpen
A Practical Way to ISO/GUM Measurement Uncertainty for Analytical Assays Including In-House Validation Data
In this contribution, we outline the estimation of measurement uncertainty of analytical assays in a practical way, according to the so-called reconciliation paradigm, by considering the heritance of uncertainties according to the ISO Guide to the expression of uncertainty in measurement (ISO/GUM) approach and the accuracy (bias and precision) study coming from the in-house method validation. A cause and effect analysis is performed by using the Ishikawa diagram or fishbone plot, consisting of a hierarchical structure reaching a final outcome that is the analytical result. The procedure is illustrated with a case study. This procedure may be very suitable for processing data in accreditation of routine assays.
- 22 August 2018
- Published by IntechOpen
Open AccessA Practical Way to ISO/GUM Measurement Uncertainty for Analytical Assays Including In-House Validation Data
In this contribution, we outline the estimation of measurement uncertainty of analytical assays in a practical way, according to the so-called reconciliation paradigm, by considering the heritance of uncertainties according to the ISO Guide to the expression of uncertainty in measurement (ISO/GUM) approach and the accuracy (bias and precision) study coming from the in-house method validation. A cause and effect analysis is performed by using the Ishikawa diagram or fishbone plot, consisting of a hierarchical structure reaching a final outcome that is the analytical result. The procedure is illustrated with a case study. This procedure may be very suitable for processing data in accreditation of routine assays.
- 8 January 2018
- Published by American Society for Enology and Viticulture in American Journal of Enology and Viticulture
- Vol. 69 (2) , 167-175
Classification of Spanish Red Wines Using Artificial Neural Networks with Enological Parameters and Mineral Content
Spanish red wines from the Canary Islands were categorized into seven classes, and 20 samples from each DO studied, Tacoronte-Acentejo (class T), Valle de la Orotava (class O), “Ycoden-Daute-Isora” (class YDI), Abona (class A), Valle de Güímar (class VG) “La Gomera” (class G) and “La Palma” (class P) were studied. Metals (B, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Ni, Na, Pb, and Zn) and physico-chemical (pH, volatile acidity, total acidity, malic acid, acetic acid, reducing sugars, alcohol content, free sulphur dioxide, total sulphur dioxide, and total polyphenols) were considered as suitable descriptors to differentiate between classes. Supervised learning pattern recognition procedures were applied. Linear discriminant analysis led to good results up to about 80% of correct classification. To improve the results, another kind of algorithms able to model non-linear separation between classes was considered: Artificial Neural Networks. Accordingly, excellent results were obtained, with 100% of the 140 wines correctly placed in the associated seven classes. Our results are in good agreement with the working hypothesis of differentiation between wines coming from different locations including different islands and also different sites in the Tenerife Island.
- 8 January 2018
- Published by American Society for Enology and Viticulture in American Journal of Enology and Viticulture
- Vol. 69 (2) , 167-175
Classification of Spanish Red Wines Using Artificial Neural Networks with Enological Parameters and Mineral Content
Spanish red wines from the Canary Islands were categorized into seven classes, and 20 samples from each DO studied, Tacoronte-Acentejo (class T), Valle de la Orotava (class O), “Ycoden-Daute-Isora” (class YDI), Abona (class A), Valle de Güímar (class VG) “La Gomera” (class G) and “La Palma” (class P) were studied. Metals (B, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Ni, Na, Pb, and Zn) and physico-chemical (pH, volatile acidity, total acidity, malic acid, acetic acid, reducing sugars, alcohol content, free sulphur dioxide, total sulphur dioxide, and total polyphenols) were considered as suitable descriptors to differentiate between classes. Supervised learning pattern recognition procedures were applied. Linear discriminant analysis led to good results up to about 80% of correct classification. To improve the results, another kind of algorithms able to model non-linear separation between classes was considered: Artificial Neural Networks. Accordingly, excellent results were obtained, with 100% of the 140 wines correctly placed in the associated seven classes. Our results are in good agreement with the working hypothesis of differentiation between wines coming from different locations including different islands and also different sites in the Tenerife Island.
- 1 October 2017
- Published by Elsevier in Food and Chemical Toxicology
- Vol. 108, 10-18
Estimation of dietary intake and target hazard quotients for metals by consumption of wines from the Canary Islands
- 1 October 2017
- Published by Elsevier in Food and Chemical Toxicology
- Vol. 108, 10-18
Estimation of dietary intake and target hazard quotients for metals by consumption of wines from the Canary Islands
- Open Access
- 5 July 2017
- Published by IntechOpen
Practical Considerations on Indirect Calibration in Analytical Chemistry
Indirect or methodological calibration in chemical analysis is outlined. The establishment of calibration curves is introduced and discussed. Linear calibration is presented and considered in three scenarios commonly faced in chemical analysis: external calibration (EC) when there are no matrix effects in the sample analysis; standard addition calibration (SAC) when these effects are present and internal standard calibration (ISC) in cases of intrinsic variability of the analytical signal or possible losses of the analyte in stages prior to the measurement. In each kind of calibration, the uncertainty and confidence interval for the determined analyte concentration are given.
- 5 July 2017
- Published by IntechOpen
Open AccessPractical Considerations on Indirect Calibration in Analytical Chemistry
Indirect or methodological calibration in chemical analysis is outlined. The establishment of calibration curves is introduced and discussed. Linear calibration is presented and considered in three scenarios commonly faced in chemical analysis: external calibration (EC) when there are no matrix effects in the sample analysis; standard addition calibration (SAC) when these effects are present and internal standard calibration (ISC) in cases of intrinsic variability of the analytical signal or possible losses of the analyte in stages prior to the measurement. In each kind of calibration, the uncertainty and confidence interval for the determined analyte concentration are given.
- Open Access
- 18 December 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (5) , 1567-1571
A multiple hollow fibre liquid-phase microextraction method for the determination of halogenated solvent residues in olive oil
The present paper describes a method based on the extraction of analytes by multiple hollow fibre liquid-phase microextraction and detection by ion-trap mass spectrometry and electron capture detectors after gas chromatographic separation. The limits of detection are in the range of 0.13–0.67 μg kg−1, five orders of magnitude lower than those reached with the European Commission Official method of analysis, with three orders of magnitude of linear range (from the quantification limits to 400 μg kg−1 for all the analytes) and recoveries in fortified olive oils in the range of 78–104 %. The main advantages of the analytical method are the absence of sample carryover (due to the disposable nature of the membranes), high enrichment factors in the range of 79–488, high throughput and low cost. The repeatability of the analytical method ranged from 8 to 15 % for all the analytes, showing a good performance.
- 18 December 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (5) , 1567-1571
Open AccessA multiple hollow fibre liquid-phase microextraction method for the determination of halogenated solvent residues in olive oil
The present paper describes a method based on the extraction of analytes by multiple hollow fibre liquid-phase microextraction and detection by ion-trap mass spectrometry and electron capture detectors after gas chromatographic separation. The limits of detection are in the range of 0.13–0.67 μg kg−1, five orders of magnitude lower than those reached with the European Commission Official method of analysis, with three orders of magnitude of linear range (from the quantification limits to 400 μg kg−1 for all the analytes) and recoveries in fortified olive oils in the range of 78–104 %. The main advantages of the analytical method are the absence of sample carryover (due to the disposable nature of the membranes), high enrichment factors in the range of 79–488, high throughput and low cost. The repeatability of the analytical method ranged from 8 to 15 % for all the analytes, showing a good performance.
- 1 November 2012
- Published by Elsevier in Food Chemistry
- Vol. 135 (1) , 309-313
Mineral profile of “fino” wines using inductively coupled plasma optical emission spectrometry methods
- 1 November 2012
- Published by Elsevier in Food Chemistry
- Vol. 135 (1) , 309-313
Mineral profile of “fino” wines using inductively coupled plasma optical emission spectrometry methods
- 23 July 2012
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 31 (10) , 2233-2238
Cylindrospermopsin determination in water by LC-MS/MS: Optimization and validation of the method and application to real samples
A new method for determining dissolved cylindrospermopsin (CYN) in waters using solid-phase extraction (SPE) with graphitized carbon cartridges and quantification by liquid chromatography coupled with tandem mass spectrometry is described and discussed. The method has been suitably validated: the linear range covered is from 0.900 to 125 µg CYN/L. Limits of detection and quantification were 0.5 and 0.9 µg CYN/L, respectively, and allow CYN determination at concentrations below the guideline proposed of 1 µg CYN/L in natural waters. The method exhibits mean recoveries from 83 to 95%, and intermediate precision (relative standard deviation (%)) values from 5 to 12%, ensuring adequacy against the Association of Official Analytical Chemists guidelines. The method is robust against the following three influential factors considered in the cleanup stage: the batch of the graphitized carbon cartridges, the flow rate of the water sample through the cartridge, and the final redissolved water volume after SPE treatment. The method has been successfully applied to detection and quantification of CYN in water samples from aquaria of a toxicological in vivo laboratory experiment. Environ. Toxicol. Chem. 2012; 31: 2233–2238. © 2012 SETAC
- 23 July 2012
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 31 (10) , 2233-2238
Cylindrospermopsin determination in water by LC-MS/MS: Optimization and validation of the method and application to real samples
A new method for determining dissolved cylindrospermopsin (CYN) in waters using solid-phase extraction (SPE) with graphitized carbon cartridges and quantification by liquid chromatography coupled with tandem mass spectrometry is described and discussed. The method has been suitably validated: the linear range covered is from 0.900 to 125 µg CYN/L. Limits of detection and quantification were 0.5 and 0.9 µg CYN/L, respectively, and allow CYN determination at concentrations below the guideline proposed of 1 µg CYN/L in natural waters. The method exhibits mean recoveries from 83 to 95%, and intermediate precision (relative standard deviation (%)) values from 5 to 12%, ensuring adequacy against the Association of Official Analytical Chemists guidelines. The method is robust against the following three influential factors considered in the cleanup stage: the batch of the graphitized carbon cartridges, the flow rate of the water sample through the cartridge, and the final redissolved water volume after SPE treatment. The method has been successfully applied to detection and quantification of CYN in water samples from aquaria of a toxicological in vivo laboratory experiment. Environ. Toxicol. Chem. 2012; 31: 2233–2238. © 2012 SETAC
- Open Access
- 1 March 2011
- Published by Springer Nature in Tree Genetics & Genomes
- Vol. 7 (4) , 781-798
Improving the quality of African robustas: QTLs for yield- and quality-related traits in Coffea canephora
- 1 March 2011
- Published by Springer Nature in Tree Genetics & Genomes
- Vol. 7 (4) , 781-798
Open AccessImproving the quality of African robustas: QTLs for yield- and quality-related traits in Coffea canephora