SFShahrokh Farhangi

Shahrokh Farhangi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shahrokh Farhangi has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal Design of PV Inverter Using LCOE Index

    by Morteza Tadbiri-Nooshabadi, Jean-Luc Schanen, Shahrokh Farhangi, Hossein Iman-Eini, Corentin Rizet

    This work uses design optimization of a power electronics converter to achieve the best levelized cost of energy in a PV application. The methodology uses detailed models of power electronics’ active and passive components to determine the cost and performances of the solid-state energy conversion and connect them to the system-level vision. The deterministic algorithm used for converter sizing allows taking into account a large number of variables and constraints. Methodology, models, and some illustrations of the results are provided in this paper. A sensitivity analysis was also conducted on the cost model.


  • Fuzzy Logic-based Control of D-SSSC under nonlinear conditions of power system

    by Mohammad Rastegar, Mehdi Saradarzadeh, Shahrokh Farhangi

    In this paper, a Fuzzy Logic Control (FLC) applied to distribution-synchronous series compensator (D-SSSC) based on the cascaded H-bridge (CHB) converter is introduced. The proposed FLC provides proper operation of the control system of SSSC during the nonlinear conditions of the power system which are unavoidable in the transmissions and distribution lines especially due to the characteristics of new power systems which are being more popular. The proposed control strategy uses a novel operation mode identification to provide a proper response considering common nonlinearities in the power system. Both the conventional control method and the proposed control method have been applied to a distribution network via MATLAB/SIMULINK®. The results validated that SSSC properly could control power flow in distribution lines accurately despite the dynamic nonlinearities of the power system.


  • An Improved and Fast MPPT Algorithm for PV Systems Under Partially Shaded Conditions

    by Masoud Etezadinejad, Behzad Asaei, Shahrokh Farhangi, Amjad Anvari-Moghaddam

    The use of solar power in some applications is challenging due to sudden changes in irradiance level and the fast occurrence of partial shading condition (PSC). For this reason, maximum power point tracking (MPPT) methods employed in photovoltaic (PV) applications allow for very fast detection and tracking of the maximum power point (MPP) during a partial shading condition. This fast reaction should minimize the power losses, have minimum steady-state oscillation and be accurate. In this paper, an analytical approach is proposed to track the real MPP in uniform irradiance condition (UIC) and PSC via the use of analytical formulas of the PV system behavior. The proposed method exhibits a rapid tracking speed, stable steady-state performance, and low sampling rate in all conditions. The characteristics and performance of the proposed algorithm under UIC and PSC are investigated and demonstrated through simulations and experimental tests.


  • Fast Artificial Neural Network Based Method for Estimation of the Global Maximum Power Point in Photovoltaic Systems

    by Sara Allahabadi, Hossein Iman-Eini, Shahrokh Farhangi

    In partially shaded photovoltaic (PV) arrays, the power-voltage curve displays multiple maxima, one of which is the global maximum power point (GMPP). One of the major concerns related to PV systems is to locate and track the GMPP in all circumstances to boost efficiency. Combining conventional hill climbing (HC) algorithm and artificial neural networks (ANNs), a new two-stage GMPP tracking method is introduced in this article that aims to be fast and accurate. Moreover, it does not require irradiance or temperature sensors. In the first stage, the current-voltage (I-V) curve is sampled at specific points determined based on the array I-V curve analysis with the objective to be the minimum samples possible that can reflect the changes of irradiance and temperature. Then a simple feedforward ANN is employed to estimate the neighborhood of the GMPP using these samples. In the second stage, the HC algorithm is adopted to ensure the GMPP is tracked precisely. The proposed method is validated by simulations in MATLAB/Simulink environment and experimental tests under uniform irradiance condition, partial shading conditions, and a wide range of temperatures.


  • A Novel Zero Voltage Transition soft-switching PWM Boost Converter with low voltage stress

    by Ali Haji Ali Biglo, Shahrokh Farhangi, Hossein Iman-Eini

    This paper presents a new fully soft switching boost converter with one auxiliary switch that provides Zero Voltage Transition (ZVT) for the main switch in Continues Current Mode (CCM). The auxiliary circuit provides soft switching condition for both switches and all diodes in both turn on and turn off operation that can provide better efficiency and reliability for converter. Furthermore, reverse recovery problems of diodes and EMI noise of switches are alleviated. Simulation tests are conducted in PLECS software and results are included to verify theoretical analyses and feasibility of the proposed soft switching structure.


  • Optimal Photovoltaic Multi-String Inverter Topology Selection Based on Reliability and Cost Analysis

    by Afshin Nazer, Sina Driss, Amir Mousa Haddadi, Shahrokh Farhangi

    Inverters are the most vulnerable parts of the photovoltaic (PV) power plants. Therefore, choosing an appropriate inverter topology to maximize the reliability and availability of the PV power plants is very important, especially in the large scale power plants. This paper proposes a novel index of Total Financial Losses (TFL) to compare different inverter topologies from reliability and energy losses points of view. Initial cost, repair cost, financial losses due to the downtime and element losses, and environmental conditions are considered in evaluating the TFL index. Using this universal index, the optimal inverter topology and its switching frequency are determined when the TFL is minimum. Regarding the fact that the reliability of power electronic devices is strongly dependent on their power losses and ambient conditions, the exact failure rates of vulnerable elements such as capacitors, switches, diodes, and cooling system are calculated. The system availability and frequencies of encountering the failure states are determined using the Markov method. Finally, the optimal photovoltaic inverter of 150 kW range is selected out of commonly used two-level and three-level topologies.


  • Three-Phase Filter-Clamped Transformerless Inverter for Grid-Connected Photovoltaic Systems with Low Leakage Current

    by Ramin Rahimi, Masoud Farhadi, Gholam Reza Moradi, Babak Farhangi, Shahrokh Farhangi

    In this paper, a Filter-Clamped (FC) inverter is employed as a three-phase grid-connected Transformerless Photovoltaic (TLPV) inverter. TLPV inverters are more efficient and more cost-effective compared to the alternatives based on high and low-frequency isolation transformers. On the other hand, TLPV inverters generate high leakage current due to the removal of the isolation transformer. Prior-art TLPV topologies have been developed to overcome this issue by either adding more semiconductor switches to block potential leakage current paths or modifying the control method. In contrast, the FC inverter addresses the leakage current issue without adding any extra component or improving the control technique. Thus, it is a promising solution to TLPV systems. Having decreased the leakage current, the FC inverter improves the THD of grid injected current and the efficiency compared to the conventional three-phase Full-Bridge (FB) inverter. Simulations and experiments are provided to validate the effectiveness of the FC inverter in terms of reduced leakage current, improved grid current THD, and improved overall efficiency.


  • Fault-Tolerant Method to Reduce Voltage Stress of Submodules in Postfault Condition for Regenerative MMC-Based Drive

    by Saleh Farzamkia, Masoud Noushak, Hossein Iman-Eini, Arash Khoshkbar-Sadigh, Shahrokh Farhangi

    In this article, we propose a fault-tolerant strategy to recover the full performance of a modular multilevel converter (MMC) under submodule (SM) fault condition for regenerative medium-voltage drive applications. The proposed method has the feature to retrieve line voltage amplitude during the postfault condition back to its nominal value. In this method, the missing capacity of the converter due to the fault condition is compensated by all remaining healthy SMs. The main advantage of the proposed method in comparison with previous works is that it imposes a lower voltage stress on switches in postfault conditions without severe circulating current. Remaining healthy SMs also operate at a similar condition, which leads to the feature of homogeneous distribution of loss and temperature in all parts of the converter. The proposed method is applicable for the regenerative MMC-based drives as well as the back-to-back configuration of MMC without adding cost or complexity to the whole system. A generalized approach is presented and its result is compared with other methods. The simulation and experimental results are provided to validate the performance and feasibility of the proposed method that can effectively enhance the fault-tolerant capability of this converter.


  • High Frequency Resonance Analysis of DFIG Based Wind Power System

    by Karen Abbaskhanian, Mohsen Hamzeh, Shahrokh Farhangi

    Doubly fed induction generator (DFIG)-based wind power system may suffer from high frequency resonance (HFR), due to impedance interaction between wind system and the network. Impedance modeling of DFIG along with its partial back-to-back converters and the medium-length $\pi$ -model distribution line is conducted in this study. Analyses of HFR is carried out based on impedance models using bode diagrams. Influences of different factors such as distribution line distance and converters' current controller gains have been investigated. Moreover, the aggravation of HFR oscillations on voltage and current waveforms are compared. Time-domain simulation in MATLAB-SIMULINK software has been adopted to validate impedance modeling and analyses.