Edgar Cruz-Valeriano
Edgar Cruz-Valeriano has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Christian Ivan Enriquez Flores
CINVESTAV Unidad Querétaro, Lib. Norponiente 2000, Real de Juriquilla, 76230 Querétaro, Qro., Mexico
4 shared publications - Jose Juan Gervacio Arciniega
CONACYT-Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla 3 , Av. San Claudio y Av. 18 sur, Col. San Manuel Ciudad Universitaria, Puebla Pue. 72570, Mexico
4 shared publications - Eduardo A. Murillo‐Bracamontes
Centro de Nanociencias y Nanotecnología (CNyN), Universidad Nacional Autónoma de México (UNAM) 2 , km. 107, Carretera Tijuana-Ensenada, Ensenada, Baja California C.P. 22860, Mexico
3 shared publications - Jose Martin Yañez Limon
Centro de Investigación y de Estudios Avanzados del IPN-Unidad Querétaro
3 shared publications M. A. Palomino-Ovando
Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla 1 , Av. San Claudio y Av. 18 sur, Col. San Manuel Ciudad Universitaria, Puebla Pue. 72570, Mexico
3 shared publications- Miller Toledo Solano
Benemérita Universidad Autónoma de Puebla
3 shared publications
Latest Publications
- Open Access
- 27 December 2022
- Published by Editorial CSIC in Revista de Metalurgia
- Vol. 58 (4) , e231
TiN hard coating as a candidate reference material for surface metrology in chemistry: characterization and quantification by bulk and surface analyses techniques
This study presents the synthesis and characterization of TiN hard coatings as a candidate reference material for surface metrology in chemistry. TiN coatings were grown on a silicon wafer with (111) orientation using dc reactive magnetron sputtering. X-ray diffraction confirms that the diffraction phase of TiN coatings is polycrystalline, electron microscopy demonstrates that the TiN coatings presents pyramidal-shaped grains ranging from sub-micrometer to nano-size scale and with an average thickness of 666 nm. According to micro Raman results, the presence of LO phonon modes confirms that the TiN coatings are crystalline in nature and no impurities are detected. The mechanical properties at the nanoscale are evaluated using resonance tracking acoustic force atomic microscopy. The chemical composition of the TiN reveals a close 1:1 atomic ratio. The ANOVA is used to evaluate the homogeneity of the TiN via a homogeneity test according to the ISO Guide 35:2017, while, regarding the chemical composition of the Ti, the Fisher’s test demonstrates that the batch can be considered as homogeneous.
- 27 December 2022
- Published by Editorial CSIC in Revista de Metalurgia
- Vol. 58 (4) , e231
Open AccessTiN hard coating as a candidate reference material for surface metrology in chemistry: characterization and quantification by bulk and surface analyses techniques
This study presents the synthesis and characterization of TiN hard coatings as a candidate reference material for surface metrology in chemistry. TiN coatings were grown on a silicon wafer with (111) orientation using dc reactive magnetron sputtering. X-ray diffraction confirms that the diffraction phase of TiN coatings is polycrystalline, electron microscopy demonstrates that the TiN coatings presents pyramidal-shaped grains ranging from sub-micrometer to nano-size scale and with an average thickness of 666 nm. According to micro Raman results, the presence of LO phonon modes confirms that the TiN coatings are crystalline in nature and no impurities are detected. The mechanical properties at the nanoscale are evaluated using resonance tracking acoustic force atomic microscopy. The chemical composition of the TiN reveals a close 1:1 atomic ratio. The ANOVA is used to evaluate the homogeneity of the TiN via a homogeneity test according to the ISO Guide 35:2017, while, regarding the chemical composition of the Ti, the Fisher’s test demonstrates that the batch can be considered as homogeneous.
- Open Access
- 1 November 2020
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (11) , 116411
Structural and mechanical properties study of CNx/MoS2 multilayer coatings obtained by sputtering
This work documents the study of samples of CNx/MoS2 multilayer coatings, deposited by magnetron sputtering technique, using 10% and 16% of N2 concentration in the Ar/N2 gas mixture to obtain two sample sets with different nitrogen concentrations in the CNx layers. The samples were grown on Si (100) and AISI 304 steel substrates to carry out different characterizations. The microstructure of the samples was investigated by scanning electron microscopy (SEM), atomic force microscopy (AFM) and x-ray diffraction (XRD). The chemical structure and vibrational modes present in the multilayer coatings were evaluated using x-ray photoelectron spectroscopy (XPS), and Raman spectroscopy, respectively. The analysis revealed that the CNx layers are amorphous, while the MoS2 layers show a polycrystalline structure with basal planes perpendicular to the substrate surface. Finally, the mechanical properties were evaluated by nanoindentation and pin on disk tests, respectively. The results revealed that the concentration of N in the CNx layer is fundamental in determining the mechanical properties. In the test carried out in a humid environment, the samples with the lowest concentration of N in the CNx layers present lower values in the coefficient of friction.
- 1 November 2020
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (11) , 116411
Open AccessStructural and mechanical properties study of CNx/MoS2 multilayer coatings obtained by sputtering
This work documents the study of samples of CNx/MoS2 multilayer coatings, deposited by magnetron sputtering technique, using 10% and 16% of N2 concentration in the Ar/N2 gas mixture to obtain two sample sets with different nitrogen concentrations in the CNx layers. The samples were grown on Si (100) and AISI 304 steel substrates to carry out different characterizations. The microstructure of the samples was investigated by scanning electron microscopy (SEM), atomic force microscopy (AFM) and x-ray diffraction (XRD). The chemical structure and vibrational modes present in the multilayer coatings were evaluated using x-ray photoelectron spectroscopy (XPS), and Raman spectroscopy, respectively. The analysis revealed that the CNx layers are amorphous, while the MoS2 layers show a polycrystalline structure with basal planes perpendicular to the substrate surface. Finally, the mechanical properties were evaluated by nanoindentation and pin on disk tests, respectively. The results revealed that the concentration of N in the CNx layer is fundamental in determining the mechanical properties. In the test carried out in a humid environment, the samples with the lowest concentration of N in the CNx layers present lower values in the coefficient of friction.
- 21 October 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (15) , 159902
Publisher’s Note: “Piezoresponse force microscopy imaging and its correlation with cantilever spring constant and frequency” [J. Appl. Phys 128, 084101 (2020)]
- 21 October 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (15) , 159902
Publisher’s Note: “Piezoresponse force microscopy imaging and its correlation with cantilever spring constant and frequency” [J. Appl. Phys 128, 084101 (2020)]
- 24 August 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (8) , 084101
Piezoresponse force microscopy imaging and its correlation with cantilever spring constant and frequency
Single-frequency piezoresponse force microscopy (PFM) images of a BiFeO3/DyScO3(110) thin film, obtained with long (kc = 0.82 N/m) and short (kc = 7.64 N/m) cantilevers, were analyzed as a function of the applied voltage frequency. For long cantilevers, the electrostatic and electrostrictive contributions were identified. These contributions were reduced with a frequency near the second mode of the contact resonance; while for short cantilevers, the first mode was necessary. A method for domain structure analyses, to discriminate a ferroelectric behavior from a non-ferroelectric, through the optimization of PFM images, is also described. The analysis can be extended to cantilevers with different spring constants and ferroelectric materials.
- 24 August 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (8) , 084101
Piezoresponse force microscopy imaging and its correlation with cantilever spring constant and frequency
Single-frequency piezoresponse force microscopy (PFM) images of a BiFeO3/DyScO3(110) thin film, obtained with long (kc = 0.82 N/m) and short (kc = 7.64 N/m) cantilevers, were analyzed as a function of the applied voltage frequency. For long cantilevers, the electrostatic and electrostrictive contributions were identified. These contributions were reduced with a frequency near the second mode of the contact resonance; while for short cantilevers, the first mode was necessary. A method for domain structure analyses, to discriminate a ferroelectric behavior from a non-ferroelectric, through the optimization of PFM images, is also described. The analysis can be extended to cantilevers with different spring constants and ferroelectric materials.
- Open Access
- 19 May 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (19) , 194102
Discrimination of a ferroelectric from a non-ferroelectric response in PFM by phase analyses at the harmonics of the applied Vac
In the last few decades, piezoresponse force microscopy (PFM) has been a valuable tool to analyze ferroelectric materials at nanoscale. Domain switching and phase-hysteresis loops acquired by PFM had been taken as a proof of ferroelectricity; however, these two characteristics have been observed in non-ferroelectric materials, generating uncertainty of the characterizations carried out by PFM. To resolve this problem, strategies have been developed but they are difficult to implement or still fail depending on the measurement conditions. In this work, we provide a simple method to effectively differentiate ferroelectric from non-ferroelectric signals in PFM analyses. It is based on the comparison of the phases of the PFM signals obtained at the first and the second harmonics of the contact resonant frequency of the Vac applied between the tip and the bottom electrode. To illustrate the effectiveness and simplicity of the method, analyses were conducted on a ferroelectric PZT film, a non-ferroelectric glass and SrTiO3 sample, and a KNN ceramic with ferroelectric and non-ferroelectric zones.
- 19 May 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (19) , 194102
Open AccessDiscrimination of a ferroelectric from a non-ferroelectric response in PFM by phase analyses at the harmonics of the applied Vac
In the last few decades, piezoresponse force microscopy (PFM) has been a valuable tool to analyze ferroelectric materials at nanoscale. Domain switching and phase-hysteresis loops acquired by PFM had been taken as a proof of ferroelectricity; however, these two characteristics have been observed in non-ferroelectric materials, generating uncertainty of the characterizations carried out by PFM. To resolve this problem, strategies have been developed but they are difficult to implement or still fail depending on the measurement conditions. In this work, we provide a simple method to effectively differentiate ferroelectric from non-ferroelectric signals in PFM analyses. It is based on the comparison of the phases of the PFM signals obtained at the first and the second harmonics of the contact resonant frequency of the Vac applied between the tip and the bottom electrode. To illustrate the effectiveness and simplicity of the method, analyses were conducted on a ferroelectric PZT film, a non-ferroelectric glass and SrTiO3 sample, and a KNN ceramic with ferroelectric and non-ferroelectric zones.
- Open Access
- 4 May 2020
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 11 (1) , 703-716
Stochastic excitation for high-resolution atomic force acoustic microscopy imaging: a system theory approach
In this work, a high-resolution atomic force acoustic microscopy imaging technique is developed in order to obtain the local indentation modulus at the nanoscale level. The technique uses a model that gives a qualitative relationship between a set of contact resonance frequencies and the indentation modulus. It is based on white-noise excitation of the tip–sample interaction and uses system theory for the extraction of the resonance modes. During conventional scanning, for each pixel, the tip–sample interaction is excited with a white-noise signal. Then, a fast Fourier transform is applied to the deflection signal that comes from the photodiodes of the atomic force microscopy (AFM) equipment. This approach allows for the measurement of several vibrational modes in a single step with high frequency resolution, with less computational cost and at a faster speed than other similar techniques. This technique is referred to as stochastic atomic force acoustic microscopy (S-AFAM), and the frequency shifts of the free resonance frequencies of an AFM cantilever are used to determine the mechanical properties of a material. S-AFAM is implemented and compared with a conventional technique (resonance tracking-atomic force acoustic microscopy, RT-AFAM). A sample of a graphite film on a glass substrate is analyzed. S-AFAM can be implemented in any AFM system due to its reduced instrumentation requirements compared to conventional techniques.
- 4 May 2020
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 11 (1) , 703-716
Open AccessStochastic excitation for high-resolution atomic force acoustic microscopy imaging: a system theory approach
In this work, a high-resolution atomic force acoustic microscopy imaging technique is developed in order to obtain the local indentation modulus at the nanoscale level. The technique uses a model that gives a qualitative relationship between a set of contact resonance frequencies and the indentation modulus. It is based on white-noise excitation of the tip–sample interaction and uses system theory for the extraction of the resonance modes. During conventional scanning, for each pixel, the tip–sample interaction is excited with a white-noise signal. Then, a fast Fourier transform is applied to the deflection signal that comes from the photodiodes of the atomic force microscopy (AFM) equipment. This approach allows for the measurement of several vibrational modes in a single step with high frequency resolution, with less computational cost and at a faster speed than other similar techniques. This technique is referred to as stochastic atomic force acoustic microscopy (S-AFAM), and the frequency shifts of the free resonance frequencies of an AFM cantilever are used to determine the mechanical properties of a material. S-AFAM is implemented and compared with a conventional technique (resonance tracking-atomic force acoustic microscopy, RT-AFAM). A sample of a graphite film on a glass substrate is analyzed. S-AFAM can be implemented in any AFM system due to its reduced instrumentation requirements compared to conventional techniques.
- Open Access
- 17 December 2019
- Published by Beilstein Institut in Beilstein Archives
- Vol. 2019 (1) , 159
Stochastic excitation for high-resolution Atomic Force Acoustic Microscopy imaging: a system theory approach.
In this work, a high-resolution Atomic Force Acoustic Microscopy imaging technique is shown in order to obtain the local indentation modulus at nanoscale using a model which gives a quantitative relationship between a set of contact resonance frequencies and indentation modulus through a white-noise excitation. This technique is based on white-noise excitation for system identification due to non-linearities in the tip-sample interaction. During a conventional scanning, a Fast Fourier Transform is applied to the deflection signal which comes from the photo-diodes of the Atomic Force Microscopy (AFM) for each pixel, while the tip-sample interaction is excited by a white-noise signal. This approach allows the measurement of several vibrational modes in a single step with high frequency resolution, less computational data and at a faster speed than other similar techniques. This technique is referred to as Stochastic Atomic Force Acoustic Microscopy (S-AFAM), where the frequency shifts with respect to free resonance frequencies for an AFM cantilever can be used to determine the mechanical properties of a material. S-AFAM is implemented and compared to a conventional technique (Resonance Tracking-Atomic Force Microscopy, RT-AFAM), where a graphite film over a glass substrate sample is analyzed. S-AFAM can be implemented in any AFM system due to its reduced instrumentation compared to conventional techniques.
- 17 December 2019
- Published by Beilstein Institut in Beilstein Archives
- Vol. 2019 (1) , 159
Open AccessStochastic excitation for high-resolution Atomic Force Acoustic Microscopy imaging: a system theory approach.
In this work, a high-resolution Atomic Force Acoustic Microscopy imaging technique is shown in order to obtain the local indentation modulus at nanoscale using a model which gives a quantitative relationship between a set of contact resonance frequencies and indentation modulus through a white-noise excitation. This technique is based on white-noise excitation for system identification due to non-linearities in the tip-sample interaction. During a conventional scanning, a Fast Fourier Transform is applied to the deflection signal which comes from the photo-diodes of the Atomic Force Microscopy (AFM) for each pixel, while the tip-sample interaction is excited by a white-noise signal. This approach allows the measurement of several vibrational modes in a single step with high frequency resolution, less computational data and at a faster speed than other similar techniques. This technique is referred to as Stochastic Atomic Force Acoustic Microscopy (S-AFAM), where the frequency shifts with respect to free resonance frequencies for an AFM cantilever can be used to determine the mechanical properties of a material. S-AFAM is implemented and compared to a conventional technique (Resonance Tracking-Atomic Force Microscopy, RT-AFAM), where a graphite film over a glass substrate sample is analyzed. S-AFAM can be implemented in any AFM system due to its reduced instrumentation compared to conventional techniques.
- 6 September 2018
- Published by Springer Nature in Applied Physics A
- Vol. 124 (10) , 667
Dielectric constant measurement using atomic force microscopy of dielectric films: a system theory approach
- 6 September 2018
- Published by Springer Nature in Applied Physics A
- Vol. 124 (10) , 667
Dielectric constant measurement using atomic force microscopy of dielectric films: a system theory approach