Mário Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mário Santos has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Jaime Batista Santos
University of Coimbra, ARISE, CEMMPRE
28 shared publications - Miguel Caixinha
Department of Electrical and Computers Engineering, University of Coimbra, Portugal
10 shared publications Elena Velte
5 shared publications- Lorena Itati Petrella
University of Coimbra
5 shared publications - Pedro M. Faia
University of Coimbra
5 shared publications - Ana Martins Amaro
University of Coimbra, Centre of Mechanical Engineering, Materials and Processes (CEMMPRE-ARISE), Department of Mechanical Engineering, 3040-248 Coimbra, Portugal
4 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG
Application of Ultrasonic Non-destructive Testing
This Special Issue Reprint focuses on cutting-edge ideas, methodologies, and experimental results related to the applications of ultrasonic non-destructive testing (UNDT) and evaluation. As a vital technique in modern industry, ultrasound plays a critical role in guaranteeing the safety and structural integrity of metallic and composite components used in demanding sectors such as aerospace, civil, and geological engineering. This volume compiles the latest research and development achievements, covering advanced testing and evaluation methods, novel equipment development, and innovative approaches to non-destructive measurements. The contributions collected in this Reprint explore key areas including the following: ultrasonic non-destructive testing and evaluation (UNDT/UNDE); ultrasonic-based structural health monitoring and damage detection; material characterization and NDT of composites; ultrasound phased arrays and guided waves; process monitoring and advanced ultrasound sensors; transducers, and sensor networks; instruments, devices, and systems designed for ultrasound research and industrial applications; propagation of ultrasound in civil, aerospace, and geological materials.
- 9 November 2026
- Published by MDPI AG
Open AccessApplication of Ultrasonic Non-destructive Testing
This Special Issue Reprint focuses on cutting-edge ideas, methodologies, and experimental results related to the applications of ultrasonic non-destructive testing (UNDT) and evaluation. As a vital technique in modern industry, ultrasound plays a critical role in guaranteeing the safety and structural integrity of metallic and composite components used in demanding sectors such as aerospace, civil, and geological engineering. This volume compiles the latest research and development achievements, covering advanced testing and evaluation methods, novel equipment development, and innovative approaches to non-destructive measurements. The contributions collected in this Reprint explore key areas including the following: ultrasonic non-destructive testing and evaluation (UNDT/UNDE); ultrasonic-based structural health monitoring and damage detection; material characterization and NDT of composites; ultrasound phased arrays and guided waves; process monitoring and advanced ultrasound sensors; transducers, and sensor networks; instruments, devices, and systems designed for ultrasound research and industrial applications; propagation of ultrasound in civil, aerospace, and geological materials.
- Open Access
- 31 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (15) , 155006
Computational modelling of liver fibrosis stages: the role of 3D Voronoi structural connectivity in elastography simulations
Objective . This study proposes a novel 3D modelling framework based on Voronoi tessellation to simulate the progression of liver fibrosis across all METAVIR stages (F0–F4), addressing the limitations of traditional simplified 2D geometries in representing hepatic tissue heterogeneity. Approach . A 3D structural model was developed where microstructural connectivity was translated into macroscopic elastic properties. Numerical simulations of shear wave propagation were performed using the k -Wave toolbox, using GPU acceleration to process high-resolution 3D volumes. The framework’s performance was validated by comparing simulated Young’s modulus values with clinical gold standards from existing literature. Main results . A collagen fibre velocity of 7.55 m s −1 was obtained using a calibration method to match clinical data results. The simulations demonstrated a good correlation ( R 2 = 0.976) with clinical data. A critical structural percolation threshold was identified during the transition from F2 to F3, where isolated collagen clusters merge into interconnected bridges, causing a marked increase stiffness increment. Furthermore, a significant discrepancy was observed between dimensions, with 2D models underestimating cirrhosis stiffness (F4) by approximately 35% compared to 3D estimations (15.23 kPa vs 23.57 kPa). Significance . The findings underscore the necessity of accounting for 3D structural connectivity to achieve accurate elastography modelling. This validated framework provides a robust virtual environment for developing advanced diagnostic sequences and improves the understanding of wave propagation in heterogeneous fibrotic tissues, potentially refining non-invasive fibrosis staging.
- 31 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (15) , 155006
Open AccessComputational modelling of liver fibrosis stages: the role of 3D Voronoi structural connectivity in elastography simulations
Objective . This study proposes a novel 3D modelling framework based on Voronoi tessellation to simulate the progression of liver fibrosis across all METAVIR stages (F0–F4), addressing the limitations of traditional simplified 2D geometries in representing hepatic tissue heterogeneity. Approach . A 3D structural model was developed where microstructural connectivity was translated into macroscopic elastic properties. Numerical simulations of shear wave propagation were performed using the k -Wave toolbox, using GPU acceleration to process high-resolution 3D volumes. The framework’s performance was validated by comparing simulated Young’s modulus values with clinical gold standards from existing literature. Main results . A collagen fibre velocity of 7.55 m s −1 was obtained using a calibration method to match clinical data results. The simulations demonstrated a good correlation ( R 2 = 0.976) with clinical data. A critical structural percolation threshold was identified during the transition from F2 to F3, where isolated collagen clusters merge into interconnected bridges, causing a marked increase stiffness increment. Furthermore, a significant discrepancy was observed between dimensions, with 2D models underestimating cirrhosis stiffness (F4) by approximately 35% compared to 3D estimations (15.23 kPa vs 23.57 kPa). Significance . The findings underscore the necessity of accounting for 3D structural connectivity to achieve accurate elastography modelling. This validated framework provides a robust virtual environment for developing advanced diagnostic sequences and improves the understanding of wave propagation in heterogeneous fibrotic tissues, potentially refining non-invasive fibrosis staging.
- Open Access
- 12 February 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (2) , 86
Non-Destructive Evaluation of Impact-Damaged Sandwich Composites: Influence of Fiber Type
This study deals with the evaluation of impact-damaged sandwich composites using different fiber types (carbon, glass, and Kevlar), where the outer layers, or “skins”, were made from the same type of fiber, while the inner layer, or “core”, consisted of a different fiber type, with the aim of improving the damage resistance and tolerance of composite materials. To achieve this goal, the following research question was formulated: can the type of core fiber used in sandwich composites primarily determine their structural response under impact? To obtain a consolidated answer, various configurations manufactured were subjected to low-velocity impact tests to induce damage. The next step involved evaluating the extent and distribution of damage across various samples using ultrasonic C-scan techniques, along with assessing the impact bending stiffness (IBS) property, a widely recognized method for measuring the structural response of composites. It was observed that the different composite configurations presented distinct absorbed energy and, consequently, different damages, which was confirmed by the IBS and the C-scan methods. The glass–carbon–glass (GCG) sandwich composite demonstrated superior performance in mitigating damage compared to the other sandwich designs. The core material was verified as the main factor influencing the response of the sandwich composite.
- 12 February 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (2) , 86
Open AccessNon-Destructive Evaluation of Impact-Damaged Sandwich Composites: Influence of Fiber Type
This study deals with the evaluation of impact-damaged sandwich composites using different fiber types (carbon, glass, and Kevlar), where the outer layers, or “skins”, were made from the same type of fiber, while the inner layer, or “core”, consisted of a different fiber type, with the aim of improving the damage resistance and tolerance of composite materials. To achieve this goal, the following research question was formulated: can the type of core fiber used in sandwich composites primarily determine their structural response under impact? To obtain a consolidated answer, various configurations manufactured were subjected to low-velocity impact tests to induce damage. The next step involved evaluating the extent and distribution of damage across various samples using ultrasonic C-scan techniques, along with assessing the impact bending stiffness (IBS) property, a widely recognized method for measuring the structural response of composites. It was observed that the different composite configurations presented distinct absorbed energy and, consequently, different damages, which was confirmed by the IBS and the C-scan methods. The glass–carbon–glass (GCG) sandwich composite demonstrated superior performance in mitigating damage compared to the other sandwich designs. The core material was verified as the main factor influencing the response of the sandwich composite.
- Open Access
- 22 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (21) , 4144
Ultrasonic A-Scan Signals Data Augmentation Using Electromechanical System Modelling to Enhance Cataract Classification Methods
The use of artificial intelligence in diverse diagnosis areas has significantly increased in the past few years because of the advantages it represents in clinical routine. Among the diverse diagnostic techniques, the use of ultrasounds is often preferred because of their simplicity, low cost, non-invasiveness, and non-ionizing characteristic. However, obtaining an adequate number of patients and data for training and testing machine learning models is challenging. To overcome this limitation, a novel approach is proposed for simulating data produced by ultrasonic diagnostic devices. The implemented method was based on a clinical prototype for eye cataract diagnosis, although the method can be extended to other applications as well. The proposed model encompasses the electric-to-acoustic signal conversion in the ultrasonic transducer, the wave propagation through the biological medium, and the subsequent acoustic-to-electric signal conversion in the transducer. Electrical modelling of the transducer was performed using a two-port network approach, while the acoustic wave propagation was modelled by using the k-Wave MATLAB toolbox. It was verified that the holistic modelling approach enabled the generation of synthetic data augmentation, presenting high similarity with real data.
- 22 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (21) , 4144
Open AccessUltrasonic A-Scan Signals Data Augmentation Using Electromechanical System Modelling to Enhance Cataract Classification Methods
The use of artificial intelligence in diverse diagnosis areas has significantly increased in the past few years because of the advantages it represents in clinical routine. Among the diverse diagnostic techniques, the use of ultrasounds is often preferred because of their simplicity, low cost, non-invasiveness, and non-ionizing characteristic. However, obtaining an adequate number of patients and data for training and testing machine learning models is challenging. To overcome this limitation, a novel approach is proposed for simulating data produced by ultrasonic diagnostic devices. The implemented method was based on a clinical prototype for eye cataract diagnosis, although the method can be extended to other applications as well. The proposed model encompasses the electric-to-acoustic signal conversion in the ultrasonic transducer, the wave propagation through the biological medium, and the subsequent acoustic-to-electric signal conversion in the transducer. Electrical modelling of the transducer was performed using a two-port network approach, while the acoustic wave propagation was modelled by using the k-Wave MATLAB toolbox. It was verified that the holistic modelling approach enabled the generation of synthetic data augmentation, presenting high similarity with real data.
- Open Access
- 29 July 2024
- Published by MDPI AG in Preprints.org
Ultrasonic A-scan Signals Data Augmentation using Electromechanical System Modelling to Enhance Cataract Classification Methods
A thorough understanding of the type and severity of cataracts is crucial for accurately estimating the optimal phacoemulsification energy. In preceding research efforts, an innovative clinical prototype known as the Eye Scan Ultrasound System (ESUS) was developed to facilitate the automated characterization of cataracts. To evaluate the effectiveness of the prototype as a medical tool, extensive data must be collected from several patients with and without cataracts. However, obtaining an adequate number of patients and data for training and testing machine learning models is challenging. To overcome this limitation, the authors implemented a simulated prototype model of the ESUS system, to augment the data. The proposed model encompasses the electric-to-acoustic signal conversion in the ultrasonic transducer, the wave propagation through the eye, and the subsequent acoustic-to-electric signal conversion. Electrical modelling of the transducer was done using a two-port network and the wave propagation was modelled by using the k-Wave MATLAB toolbox. This holistic modelling approach enabled the generation of synthetic data augmentation, presenting great similarity with real data. The synthetic data can then be employed together with real data for the purpose of cataract classification.
- 29 July 2024
- Published by MDPI AG in Preprints.org
Open AccessUltrasonic A-scan Signals Data Augmentation using Electromechanical System Modelling to Enhance Cataract Classification Methods
A thorough understanding of the type and severity of cataracts is crucial for accurately estimating the optimal phacoemulsification energy. In preceding research efforts, an innovative clinical prototype known as the Eye Scan Ultrasound System (ESUS) was developed to facilitate the automated characterization of cataracts. To evaluate the effectiveness of the prototype as a medical tool, extensive data must be collected from several patients with and without cataracts. However, obtaining an adequate number of patients and data for training and testing machine learning models is challenging. To overcome this limitation, the authors implemented a simulated prototype model of the ESUS system, to augment the data. The proposed model encompasses the electric-to-acoustic signal conversion in the ultrasonic transducer, the wave propagation through the eye, and the subsequent acoustic-to-electric signal conversion. Electrical modelling of the transducer was done using a two-port network and the wave propagation was modelled by using the k-Wave MATLAB toolbox. This holistic modelling approach enabled the generation of synthetic data augmentation, presenting great similarity with real data. The synthetic data can then be employed together with real data for the purpose of cataract classification.
- Open Access
- 2 June 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 157, 106610
Animal model for in-vivo Nuclear Cataract. Lens hardness and elasticity assessment.
- 2 June 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 157, 106610
Open AccessAnimal model for in-vivo Nuclear Cataract. Lens hardness and elasticity assessment.
- Open Access
- 26 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (11) , 6523
Adhesive Single-Lap Joint Evaluation Using Ultrasound Guided Waves
This work deals with the evaluation of adhesive single-lap joints using ultrasound guided waves; in particular, it is intended to characterize the signal propagation when defects are present in the adhesive joint by simulation and experimental approaches. The propagation of guided waves in the joint is developed from matrix formulations. The behavior of the guided wave modes that exist in the bonded region is characterized. It is found that its amplitudes can be estimated from the properties of the incoming wave that propagates in the non-bonded region. It is verified that the excitation of these modes is related to the degree to which the shapes of both modes match each other. A 3D simulation of two aluminum-bonded plates using 500 kHz ultrasonic transducers in a pitch-and-catch configuration was implemented using the Matlab k-Wave toolbox. Scattering effects, due to some defects located in the bond line of the joints, were simulated. The experimental setup with some artificial defects produced in the aluminum joints was used in order to compare it with the simulation. Qualitative agreement was observed between the two approaches. The observed deviation can be due to the different characteristics of the experimental and simulated defects.
- 26 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (11) , 6523
Open AccessAdhesive Single-Lap Joint Evaluation Using Ultrasound Guided Waves
This work deals with the evaluation of adhesive single-lap joints using ultrasound guided waves; in particular, it is intended to characterize the signal propagation when defects are present in the adhesive joint by simulation and experimental approaches. The propagation of guided waves in the joint is developed from matrix formulations. The behavior of the guided wave modes that exist in the bonded region is characterized. It is found that its amplitudes can be estimated from the properties of the incoming wave that propagates in the non-bonded region. It is verified that the excitation of these modes is related to the degree to which the shapes of both modes match each other. A 3D simulation of two aluminum-bonded plates using 500 kHz ultrasonic transducers in a pitch-and-catch configuration was implemented using the Matlab k-Wave toolbox. Scattering effects, due to some defects located in the bond line of the joints, were simulated. The experimental setup with some artificial defects produced in the aluminum joints was used in order to compare it with the simulation. Qualitative agreement was observed between the two approaches. The observed deviation can be due to the different characteristics of the experimental and simulated defects.
- Open Access
- 9 May 2023
- Published by MDPI AG in Preprints.org
Adhesive Single-Lap Joints Evaluation Using Ultrasonic Guided Waves
This work deals with the evaluation of adhesive single-lap joints using ultrasonic guided waves. An adhesive bonded lap joint can be modelled as a three-layer system made up of two adherents and an adhesive. The propagation of guided waves in the joint is developed from matrix formulations. The behavior of the different guided wave modes that propagate in the bonded region is characterized and it is found that their relative amplitudes can be estimated based on the properties of the incoming wave that propagates in the non-bonded region. It was verified that the excitation of these modes is ruled by the degree in which the shapes of both modes match each other. A 3D simulation of two aluminium bonded plates using 500 kHz ultrasonic transducers in a pitch and catch configuration was implemented using the Matlab k-Wave toolbox. Scattering effects due to some produced defects located in the bond line of the lap joints were simulated. Experimental setup with some artificial defects produced in the aluminum joints were used in order to compare with the simulated. Qualitative agreement was observed for the two approaches. The observed deviation can be due to the different characteristics of the experimental and simulated defects.
- 9 May 2023
- Published by MDPI AG in Preprints.org
Open AccessAdhesive Single-Lap Joints Evaluation Using Ultrasonic Guided Waves
This work deals with the evaluation of adhesive single-lap joints using ultrasonic guided waves. An adhesive bonded lap joint can be modelled as a three-layer system made up of two adherents and an adhesive. The propagation of guided waves in the joint is developed from matrix formulations. The behavior of the different guided wave modes that propagate in the bonded region is characterized and it is found that their relative amplitudes can be estimated based on the properties of the incoming wave that propagates in the non-bonded region. It was verified that the excitation of these modes is ruled by the degree in which the shapes of both modes match each other. A 3D simulation of two aluminium bonded plates using 500 kHz ultrasonic transducers in a pitch and catch configuration was implemented using the Matlab k-Wave toolbox. Scattering effects due to some produced defects located in the bond line of the lap joints were simulated. Experimental setup with some artificial defects produced in the aluminum joints were used in order to compare with the simulated. Qualitative agreement was observed for the two approaches. The observed deviation can be due to the different characteristics of the experimental and simulated defects.
- Open Access
Phase-Resolved Optical Coherence Elastography: An Insight into Tissue Displacement Estimation
Robust methods to compute tissue displacements in optical coherence elastography (OCE) data are paramount, as they play a significant role in the accuracy of tissue elastic properties estimation. In this study, the accuracy of different phase estimators was evaluated on simulated OCE data, where the displacements can be accurately set, and on real data. Displacement () estimates were computed from (i) the original interferogram data and two phase-invariant mathematical manipulations of the interferogram: (ii) its first-order derivative () and (iii) its integral (). We observed a dependence of the phase difference estimation accuracy on the initial depth location of the scatterer and the magnitude of the tissue displacement. However, by combining the three phase-difference estimates (, the error in phase difference estimation could be minimized. By using , the median root-mean-square error associated with displacement prediction in simulated OCE data was reduced by 85% and 70% in data with and without noise, respectively, in relation to the traditional estimate. Furthermore, a modest improvement in the minimum detectable displacement in real OCE data was also observed, particularly in data with low signal-to-noise ratios. The feasibility of using to estimate agarose phantoms’ Young’s modulus is illustrated.Open AccessPhase-Resolved Optical Coherence Elastography: An Insight into Tissue Displacement Estimation
Robust methods to compute tissue displacements in optical coherence elastography (OCE) data are paramount, as they play a significant role in the accuracy of tissue elastic properties estimation. In this study, the accuracy of different phase estimators was evaluated on simulated OCE data, where the displacements can be accurately set, and on real data. Displacement () estimates were computed from (i) the original interferogram data and two phase-invariant mathematical manipulations of the interferogram: (ii) its first-order derivative () and (iii) its integral (). We observed a dependence of the phase difference estimation accuracy on the initial depth location of the scatterer and the magnitude of the tissue displacement. However, by combining the three phase-difference estimates (, the error in phase difference estimation could be minimized. By using , the median root-mean-square error associated with displacement prediction in simulated OCE data was reduced by 85% and 70% in data with and without noise, respectively, in relation to the traditional estimate. Furthermore, a modest improvement in the minimum detectable displacement in real OCE data was also observed, particularly in data with low signal-to-noise ratios. The feasibility of using to estimate agarose phantoms’ Young’s modulus is illustrated. - Open Access
- 8 September 2022
- Published by MDPI AG in Electronics
- Vol. 11 (18) , 2836
Computational Simulation of Microflaw Detection in Carbon-Fiber-Reinforced Polymers
The evaluation of microflaws in carbon-fiber-reinforced composite laminate (CFRP) via ultrasound requires the knowledge of some important factors in addition to its structural composition. Since the laminates are heterogeneous, the high-frequency requirements to acquire high-resolution signals have limitations due to the great scattering that prevents good signal-to-noise ratios. Additionally, the ultrasonic probe’s spatial and lateral resolution characteristics are important parameters for determining the detectability level of microflaws. Modelling appears as a good approach to evaluating the abovementioned factors and the probability of detection of defects in the micron range because it makes it possible to reduce the time and cost associated with developments based on experimental tests. Concerning the subject of this work, simulation is the best way to evaluate the detectability level of the proposed defects since experimental samples are not available. In this work, the simulation was implemented using the Matlab k-Wave toolbox. A 2D matrix for mimicking a CFRP was constructed with 1 μm of resolution. Four different defect types in the micron range were created in the matrix. The simulated and experimental results presented good agreement. It was concluded that the highest frequency probe that could be used to detect the simulated defects without ambiguity was 25 MHz.
- 8 September 2022
- Published by MDPI AG in Electronics
- Vol. 11 (18) , 2836
Open AccessComputational Simulation of Microflaw Detection in Carbon-Fiber-Reinforced Polymers
The evaluation of microflaws in carbon-fiber-reinforced composite laminate (CFRP) via ultrasound requires the knowledge of some important factors in addition to its structural composition. Since the laminates are heterogeneous, the high-frequency requirements to acquire high-resolution signals have limitations due to the great scattering that prevents good signal-to-noise ratios. Additionally, the ultrasonic probe’s spatial and lateral resolution characteristics are important parameters for determining the detectability level of microflaws. Modelling appears as a good approach to evaluating the abovementioned factors and the probability of detection of defects in the micron range because it makes it possible to reduce the time and cost associated with developments based on experimental tests. Concerning the subject of this work, simulation is the best way to evaluate the detectability level of the proposed defects since experimental samples are not available. In this work, the simulation was implemented using the Matlab k-Wave toolbox. A 2D matrix for mimicking a CFRP was constructed with 1 μm of resolution. Four different defect types in the micron range were created in the matrix. The simulated and experimental results presented good agreement. It was concluded that the highest frequency probe that could be used to detect the simulated defects without ambiguity was 25 MHz.