Bo Jakobsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bo Jakobsen has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
- Kristine Niss
“Glass and Time”, IMFUFA, Department of Science and Environment, Roskilde University, Postbox 260, DK-4000 Roskilde, Denmark
13 shared publications - Jeppe C. Dyre
Roskilde University
12 shared publications Niels Boye Olsen
Roskilde University “Glass and Time”, IMFUFA, Department of Sciences Postbox 260, DK-4000 Roskilde, Denmark
12 shared publicationsTage Christensen
Roskilde University “Glass and Time”, IMFUFA, Department of Sciences Postbox 260, DK-4000 Roskilde, Denmark
12 shared publications- Henning Friis Poulsen
Department of Physics Technical University of Denmark Kongens Lyngby Denmark
10 shared publications - Tina Hecksher
“Glass and Time,” IMFUFA, Department of Science and Environment, Roskilde University 1 , Universitetsvej 1, Roskilde 4000
9 shared publications
Latest Publications
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Solvothermal vapor annealing and environmental control setup with adjustable magnetic field module for grazing incidence small-angle x-ray scattering studies
A compact, modular environmental control and solvothermal vapor annealing chamber designed for maintaining a controlled atmosphere with regard to solvent humidity and temperature is presented. The setup allows ex situ and in situ Grazing Incidence Small-Angle X-ray Scattering (GISAXS) investigations of thin film self-assembly and reorganization. Its modular slotting system enables stable reconfiguration, including the integration of an adjustable magnetic field module. The temperature is maintained via a water-based heating and cooling loop supplemented by resistive elements, and the solvent vapor environment is regulated using a commercial controlled mixing and evaporation unit. The performance of the setup is validated through measurements of fill and quench times together with magnetic field mapping using Gauss meter measurements and finite element simulations. Furthermore, the versatility of the setup is demonstrated with three research examples using the chamber for solvothermal vapor annealing of block copolymer thin films together with lab-based ex situ and in situ GISAXS measurements. The portable new design offers robust environmental control and flexibility for advanced thin film investigations both in the lab and at large scale facilities. The design can be adapted for Grazing Incidence Small-Angle Neutron Scattering, GISANS.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Solvothermal vapor annealing and environmental control setup with adjustable magnetic field module for grazing incidence small-angle x-ray scattering studies
A compact, modular environmental control and solvothermal vapor annealing chamber designed for maintaining a controlled atmosphere with regard to solvent humidity and temperature is presented. The setup allows ex situ and in situ Grazing Incidence Small-Angle X-ray Scattering (GISAXS) investigations of thin film self-assembly and reorganization. Its modular slotting system enables stable reconfiguration, including the integration of an adjustable magnetic field module. The temperature is maintained via a water-based heating and cooling loop supplemented by resistive elements, and the solvent vapor environment is regulated using a commercial controlled mixing and evaporation unit. The performance of the setup is validated through measurements of fill and quench times together with magnetic field mapping using Gauss meter measurements and finite element simulations. Furthermore, the versatility of the setup is demonstrated with three research examples using the chamber for solvothermal vapor annealing of block copolymer thin films together with lab-based ex situ and in situ GISAXS measurements. The portable new design offers robust environmental control and flexibility for advanced thin film investigations both in the lab and at large scale facilities. The design can be adapted for Grazing Incidence Small-Angle Neutron Scattering, GISANS.
- 8 November 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (46) , 29003-29014
Density scaling and isodynes in glycerol–water mixtures
This paper presents dielectric and neutron spectroscopy data on two different glycerol–water mixtures at elevated pressures.
- 8 November 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (46) , 29003-29014
Density scaling and isodynes in glycerol–water mixtures
This paper presents dielectric and neutron spectroscopy data on two different glycerol–water mixtures at elevated pressures.
- Open Access
- 1 June 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (6)
Solvothermal vapor annealing setup for thin film treatment: A compact design with in situ solvent vapor concentration probe
A compact setup for in situ solvothermal vapor annealing of thin polymer films in the temperature range from room temperature to 70 °C is presented. The design is optimized to avoid solvent condensation in tubes and other components. The setup consists of a chamber, a gas delivery system, a commercial film-thickness measuring device, and a solvent vapor concentration sensor. The chamber is equipped with heaters and thermometers and is thermally insulated. It has windows to allow for penetration of xrays together with a sample table with a gas distributer to ensure homogeneous swelling of the polymer film. The computer-controlled gas delivery system has two different components, which can be used separately or in parallel (for mixed gas solvent annealing): (a) mass flow controllers and a bubbler system and (b) a commercial “controlled evaporation and mixing” system. The film-swelling ratio is determined in situ using optical reflectometry, and the solvent concentration in the exhaust gas is continuously monitored by UV-absorption. Test results are presented where the setup is used for swelling of ∼100 nm thick polystyrene and polyisoprene homopolymer films with toluene and acetone, respectively.
- 1 June 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (6)
Open AccessSolvothermal vapor annealing setup for thin film treatment: A compact design with in situ solvent vapor concentration probe
A compact setup for in situ solvothermal vapor annealing of thin polymer films in the temperature range from room temperature to 70 °C is presented. The design is optimized to avoid solvent condensation in tubes and other components. The setup consists of a chamber, a gas delivery system, a commercial film-thickness measuring device, and a solvent vapor concentration sensor. The chamber is equipped with heaters and thermometers and is thermally insulated. It has windows to allow for penetration of xrays together with a sample table with a gas distributer to ensure homogeneous swelling of the polymer film. The computer-controlled gas delivery system has two different components, which can be used separately or in parallel (for mixed gas solvent annealing): (a) mass flow controllers and a bubbler system and (b) a commercial “controlled evaporation and mixing” system. The film-swelling ratio is determined in situ using optical reflectometry, and the solvent concentration in the exhaust gas is continuously monitored by UV-absorption. Test results are presented where the setup is used for swelling of ∼100 nm thick polystyrene and polyisoprene homopolymer films with toluene and acetone, respectively.
- Open Access
- 22 May 2019
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 21 (1-2) , 47-57
Huginn: A Peltier-based sub-cryostat for neutron scattering
A longstanding problem in facility based experiments is the time one must wait whilst changing sample temperature. This issue is most often confronted at cryogenic temperatures above 100 K, where thermal response times can be very slow. These can be
- 22 May 2019
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 21 (1-2) , 47-57
Open AccessHuginn: A Peltier-based sub-cryostat for neutron scattering
A longstanding problem in facility based experiments is the time one must wait whilst changing sample temperature. This issue is most often confronted at cryogenic temperatures above 100 K, where thermal response times can be very slow. These can be
- 1 February 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (2) , 023904
High-pressure cell for simultaneous dielectric and neutron spectroscopy
In this article, we report on the design, manufacture, and testing of a high-pressure cell for simultaneous dielectric and neutron spectroscopy. This cell is a unique tool for studying dynamics on different time scales, from kilo- to picoseconds, covering universal features such as the α relaxation and fast vibrations at the same time. The cell, constructed in cylindrical geometry, is made of a high-strength aluminum alloy and operates up to 500 MPa in a temperature range between roughly 2 and 320 K. In order to measure the scattered neutron intensity and the sample capacitance simultaneously, a cylindrical capacitor is positioned within the bore of the high-pressure container. The capacitor consists of two concentric electrodes separated by insulating spacers. The performance of this setup has been successfully verified by collecting simultaneous dielectric and neutron spectroscopy data on dipropylene glycol, using both backscattering and time-of-flight instruments. We have carried out the experiments at different combinations of temperature and pressure in both the supercooled liquid and glassy state.
- 1 February 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (2) , 023904
High-pressure cell for simultaneous dielectric and neutron spectroscopy
In this article, we report on the design, manufacture, and testing of a high-pressure cell for simultaneous dielectric and neutron spectroscopy. This cell is a unique tool for studying dynamics on different time scales, from kilo- to picoseconds, covering universal features such as the α relaxation and fast vibrations at the same time. The cell, constructed in cylindrical geometry, is made of a high-strength aluminum alloy and operates up to 500 MPa in a temperature range between roughly 2 and 320 K. In order to measure the scattered neutron intensity and the sample capacitance simultaneously, a cylindrical capacitor is positioned within the bore of the high-pressure container. The capacitor consists of two concentric electrodes separated by insulating spacers. The performance of this setup has been successfully verified by collecting simultaneous dielectric and neutron spectroscopy data on dipropylene glycol, using both backscattering and time-of-flight instruments. We have carried out the experiments at different combinations of temperature and pressure in both the supercooled liquid and glassy state.
- Open Access
- 3 October 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (98) , 95910-95919
A multiple length scale description of the mechanism of elastomer stretching
Conventionally, the stretching of rubber is modeled exclusively by rotations of segments of the embedded polymer chains; i.e. changes in entropy. However models have not been tested on all relevant length scales due to a lack of appropriate probes. Here we present a universal X-ray based method for providing data on the structure of rubbers in the 2–50 Å range. First results relate to the elongation of a silicone rubber. We identify several non-entropic contributions to the free energy and describe the associated structural changes. By far the largest contribution comes from structural changes within the individual monomers, but among the contributions is also an elastic strain, acting between chains, which is 3–4 orders of magnitude smaller than the macroscopic strain, and of the opposite sign, i.e. extension of polymer chains in the direction perpendicular to the stretch. This may be due to trapped entanglements relaxing to positions close to the covalent crosslinks.
- 3 October 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (98) , 95910-95919
Open AccessA multiple length scale description of the mechanism of elastomer stretching
Conventionally, the stretching of rubber is modeled exclusively by rotations of segments of the embedded polymer chains; i.e. changes in entropy. However models have not been tested on all relevant length scales due to a lack of appropriate probes. Here we present a universal X-ray based method for providing data on the structure of rubbers in the 2–50 Å range. First results relate to the elongation of a silicone rubber. We identify several non-entropic contributions to the free energy and describe the associated structural changes. By far the largest contribution comes from structural changes within the individual monomers, but among the contributions is also an elastic strain, acting between chains, which is 3–4 orders of magnitude smaller than the macroscopic strain, and of the opposite sign, i.e. extension of polymer chains in the direction perpendicular to the stretch. This may be due to trapped entanglements relaxing to positions close to the covalent crosslinks.
- Open Access
- 1 May 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (5) , 055019
Thermalization calorimetry: A simple method for investigating glass transition and crystallization of supercooled liquids
We present a simple method for fast and cheap thermal analysis on supercooled glass-forming liquids. This “Thermalization Calorimetry” technique is based on monitoring the temperature and its rate of change during heating or cooling of a sample for which the thermal power input comes from heat conduction through an insulating material, i.e., is proportional to the temperature difference between sample and surroundings. The monitored signal reflects the sample’s specific heat and is sensitive to exo- and endothermic processes. The technique is useful for studying supercooled liquids and their crystallization, e.g., for locating the glass transition and melting point(s), as well as for investigating the stability against crystallization and estimating the relative change in specific heat between the solid and liquid phases at the glass transition.
- 1 May 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (5) , 055019
Open AccessThermalization calorimetry: A simple method for investigating glass transition and crystallization of supercooled liquids
We present a simple method for fast and cheap thermal analysis on supercooled glass-forming liquids. This “Thermalization Calorimetry” technique is based on monitoring the temperature and its rate of change during heating or cooling of a sample for which the thermal power input comes from heat conduction through an insulating material, i.e., is proportional to the temperature difference between sample and surroundings. The monitored signal reflects the sample’s specific heat and is sensitive to exo- and endothermic processes. The technique is useful for studying supercooled liquids and their crystallization, e.g., for locating the glass transition and melting point(s), as well as for investigating the stability against crystallization and estimating the relative change in specific heat between the solid and liquid phases at the glass transition.
- 9 December 2015
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 143 (22) , 221101
Communication: High pressure specific heat spectroscopy reveals simple relaxation behavior of glass forming molecular liquid
The frequency dependent specific heat has been measured under pressure for the molecular glass forming liquid 5-polyphenyl-4-ether in the viscous regime close to the glass transition. The temperature and pressure dependences of the characteristic time scale associated with the specific heat is compared to the equivalent time scale from dielectric spectroscopy performed under identical conditions. It is shown that the ratio between the two time scales is independent of both temperature and pressure. This observation is non-trivial and demonstrates the existence of specially simple molecular liquids in which different physical relaxation processes are both as function of temperature and pressure/density governed by the same underlying “inner clock.” Furthermore, the results are discussed in terms of the recent conjecture that van der Waals liquids, like the measured liquid, comply to the isomorph theory.
- 9 December 2015
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 143 (22) , 221101
Communication: High pressure specific heat spectroscopy reveals simple relaxation behavior of glass forming molecular liquid
The frequency dependent specific heat has been measured under pressure for the molecular glass forming liquid 5-polyphenyl-4-ether in the viscous regime close to the glass transition. The temperature and pressure dependences of the characteristic time scale associated with the specific heat is compared to the equivalent time scale from dielectric spectroscopy performed under identical conditions. It is shown that the ratio between the two time scales is independent of both temperature and pressure. This observation is non-trivial and demonstrates the existence of specially simple molecular liquids in which different physical relaxation processes are both as function of temperature and pressure/density governed by the same underlying “inner clock.” Furthermore, the results are discussed in terms of the recent conjecture that van der Waals liquids, like the measured liquid, comply to the isomorph theory.
- 12 November 2015
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 143 (18) , 181102
Communication: Slow supramolecular mode in amine and thiol derivatives of 2-ethyl-1-hexanol revealed by combined dielectric and shear-mechanical studies
In this paper, we present results of dielectric and shear-mechanical studies for amine (2-ethyl-1-hexylamine) and thiol (2-ethyl-1-hexanethiol) derivatives of the monohydroxy alcohol, 2-ethyl-1-hexanol. The amine and thiol can form hydrogen bonds weaker in strength than those of the alcohol. The combination of dielectric and shear-mechanical data enables us to reveal the presence of a relaxation mode slower than the α-relaxation. This mode is analogous to the Debye mode seen in monohydroxy alcohols and demonstrates that supramolecular structures are present for systems with lower hydrogen bonding strength. We report some key features accompanying the decrease in the strength of the hydrogen bonding interactions on the relaxation dynamics close to the glass-transition. This includes changes (i) in the amplitude of the Debye and α-relaxations and (ii) the separation between primary and secondary modes.
- 12 November 2015
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 143 (18) , 181102
Communication: Slow supramolecular mode in amine and thiol derivatives of 2-ethyl-1-hexanol revealed by combined dielectric and shear-mechanical studies
In this paper, we present results of dielectric and shear-mechanical studies for amine (2-ethyl-1-hexylamine) and thiol (2-ethyl-1-hexanethiol) derivatives of the monohydroxy alcohol, 2-ethyl-1-hexanol. The amine and thiol can form hydrogen bonds weaker in strength than those of the alcohol. The combination of dielectric and shear-mechanical data enables us to reveal the presence of a relaxation mode slower than the α-relaxation. This mode is analogous to the Debye mode seen in monohydroxy alcohols and demonstrates that supramolecular structures are present for systems with lower hydrogen bonding strength. We report some key features accompanying the decrease in the strength of the hydrogen bonding interactions on the relaxation dynamics close to the glass-transition. This includes changes (i) in the amplitude of the Debye and α-relaxations and (ii) the separation between primary and secondary modes.