Berend E. Westerhof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Berend E. Westerhof has a total of 194 co-authors. Here are the top co-authors by number of shared publications:
- Alun David Hughes
Institute of Cardiovascular Science, University College London, London, UK
4 shared publications Joanne A. Groeneveldt
Department of Pulmonary Medicine Amsterdam Universitair Medische Centra Vrije Universiteit Amsterdam Amsterdam Cardiovascular Sciences Amsterdam The Netherlands
4 shared publications- Bert Jan H van Den Born
Department of Public and Occupational Health, Amsterdam UMC, University of Amsterdam, Amsterdam Public Health Research Institute, Amsterdam, The Netherlands
3 shared publications Chen-Huan Chen
Department of Medicine, National Yang Ming Chiao Tung University, Department of Medical Education, Taipei Veterans General Hospital, Taiwan (C.-H.C., H.-M.C.).
3 shared publicationsFrances S. de Man
3 shared publications- Fuyou Liang
Key Laboratory of Hydrodynamics (MOE), Department of Engineering Mechanics, School of Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications
Latest Publications
- 1 September 2025
- Published by Wolters Kluwer Health in Hypertension
- Vol. 82 (9) , 1460-1468
Systolic BP Amplification: Systematic Review and Individual Participant Meta-Analysis
BACKGROUND: Systolic blood pressure (SBP) amplification is a physiological phenomenon related to the level of pressure difference between the aorta and brachial artery and is associated with cuff blood pressure (BP) measurement inaccuracy. However, knowledge on the invasively measured level of aortic-to-brachial SBP amplification is limited. This study aimed to explore this, as well as anticipated effects on hypertension classification. METHODS: A systematic review and individual participant data meta-analysis identified invasive brachial and aortic BP recorded in 1151 participants (62±12 years, 72% male). SBP amplification was calculated as brachial SBP minus aortic SBP. Hypertension classification (defined according to previously described thresholds for brachial and aortic BP) was compared between the aortic and brachial BP measures. RESULTS: There was a wide range of SBP amplification, which was similar between male and female (mean±SD, 8±9 mm Hg and 7±10 mm Hg, respectively) and decreased with increasing age. High SBP amplification (>15 mm Hg) was observed in 17.4% (male, 16.8% versus female, 19.5%; P =0.44), and low SBP amplification (P =0.95). The overall level of agreement between hypertension classification based on brachial and aortic BP was moderate (κ, 0.67; P <0.001; agreement, 87.4%). Agreement in hypertension classification was 65.0%, 38.1%, and 92.7% across classifications of optimal, prehypertension, and hypertension, respectively. CONCLUSIONS: In males and females there is wide variability in aortic-to-brachial SBP amplification. There were major theoretical differences in hypertension classification based on brachial versus aortic BP. This knowledge may help toward innovations for improving cuff BP measurement accuracy.
- 1 September 2025
- Published by Wolters Kluwer Health in Hypertension
- Vol. 82 (9) , 1460-1468
Systolic BP Amplification: Systematic Review and Individual Participant Meta-Analysis
BACKGROUND: Systolic blood pressure (SBP) amplification is a physiological phenomenon related to the level of pressure difference between the aorta and brachial artery and is associated with cuff blood pressure (BP) measurement inaccuracy. However, knowledge on the invasively measured level of aortic-to-brachial SBP amplification is limited. This study aimed to explore this, as well as anticipated effects on hypertension classification. METHODS: A systematic review and individual participant data meta-analysis identified invasive brachial and aortic BP recorded in 1151 participants (62±12 years, 72% male). SBP amplification was calculated as brachial SBP minus aortic SBP. Hypertension classification (defined according to previously described thresholds for brachial and aortic BP) was compared between the aortic and brachial BP measures. RESULTS: There was a wide range of SBP amplification, which was similar between male and female (mean±SD, 8±9 mm Hg and 7±10 mm Hg, respectively) and decreased with increasing age. High SBP amplification (>15 mm Hg) was observed in 17.4% (male, 16.8% versus female, 19.5%; P =0.44), and low SBP amplification (P =0.95). The overall level of agreement between hypertension classification based on brachial and aortic BP was moderate (κ, 0.67; P <0.001; agreement, 87.4%). Agreement in hypertension classification was 65.0%, 38.1%, and 92.7% across classifications of optimal, prehypertension, and hypertension, respectively. CONCLUSIONS: In males and females there is wide variability in aortic-to-brachial SBP amplification. There were major theoretical differences in hypertension classification based on brachial versus aortic BP. This knowledge may help toward innovations for improving cuff BP measurement accuracy.
- 1 March 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 138 (3) , 623-633
Combining hyperpolarized 129Xe MR imaging and spectroscopy to noninvasively estimate pulmonary vascular resistance
Cardiogenic oscillations in the 129Xe red blood cell (RBC) resonance decrease in precapillary pulmonary hypertension (PH) but are enhanced when capillary blood volume is reduced. To separate these effects, we developed a physiological model that used 129Xe gas exchange MRI to estimate blood volume, which was used to correct oscillation amplitude measurements. Corrected amplitudes correlated significantly with pulmonary vascular resistance, highlighting the potential for future noninvasive detection of PH.
- 1 March 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 138 (3) , 623-633
Combining hyperpolarized 129Xe MR imaging and spectroscopy to noninvasively estimate pulmonary vascular resistance
Cardiogenic oscillations in the 129Xe red blood cell (RBC) resonance decrease in precapillary pulmonary hypertension (PH) but are enhanced when capillary blood volume is reduced. To separate these effects, we developed a physiological model that used 129Xe gas exchange MRI to estimate blood volume, which was used to correct oscillation amplitude measurements. Corrected amplitudes correlated significantly with pulmonary vascular resistance, highlighting the potential for future noninvasive detection of PH.
- 1 February 2025
- Published by Wolters Kluwer Health in Hypertension
- Vol. 82 (2) , 347-356
Baroreflex Sensitivity and Long-Term Dementia Risk in Older Adults
BACKGROUND: Increased blood pressure (BP) variability is linked to dementia risk, but the relationship between baroreflex sensitivity (BRS), a fundamental mechanism for maintaining stable BP, and dementia risk is undetermined. METHODS: We tested the hypothesis that impaired BRS is associated with increased dementia risk in 1819 older adults (63% women; age, 71.0±6.3 years) from the community-based Rotterdam Study. Cardiac BRS was determined from a 5-minute beat-to-beat BP recording at supine rest between 1997 and 1999. Cardiac BRS measures the correlation between changes in consecutive beat-to-beat systolic BP and subsequent responses in heartbeat intervals, with a higher value indicating better BRS. The primary outcome was incident dementia ascertained from baseline through January 1, 2020; the secondary outcome was all-cause mortality. RESULTS: During a median follow-up of 14.8 years, 421 participants developed dementia. The association of cardiac BRS with dementia risk differed by antihypertensive medication use ( P interaction =0.03) and was only observed in participants not taking antihypertensives. Specifically, in those not taking antihypertensive medication, reduced BRS was associated with a higher risk of dementia (adjusted hazard ratio comparing bottom versus top quintiles, 1.60 [95% CI, 1.07–2.40]; P trend =0.02). Reduced BRS was also associated with an increased risk of death (corresponding hazard ratio, 1.76 [95% CI, 1.32–2.35]). The association remained after adjusting for average BP and BP variability. CONCLUSIONS: Impaired BRS partly explains hypertension-related brain damage and excessive dementia risk beyond conventional BP measures, making it a potential novel biomarker for the early detection and prevention of dementia.
- 1 February 2025
- Published by Wolters Kluwer Health in Hypertension
- Vol. 82 (2) , 347-356
Baroreflex Sensitivity and Long-Term Dementia Risk in Older Adults
BACKGROUND: Increased blood pressure (BP) variability is linked to dementia risk, but the relationship between baroreflex sensitivity (BRS), a fundamental mechanism for maintaining stable BP, and dementia risk is undetermined. METHODS: We tested the hypothesis that impaired BRS is associated with increased dementia risk in 1819 older adults (63% women; age, 71.0±6.3 years) from the community-based Rotterdam Study. Cardiac BRS was determined from a 5-minute beat-to-beat BP recording at supine rest between 1997 and 1999. Cardiac BRS measures the correlation between changes in consecutive beat-to-beat systolic BP and subsequent responses in heartbeat intervals, with a higher value indicating better BRS. The primary outcome was incident dementia ascertained from baseline through January 1, 2020; the secondary outcome was all-cause mortality. RESULTS: During a median follow-up of 14.8 years, 421 participants developed dementia. The association of cardiac BRS with dementia risk differed by antihypertensive medication use ( P interaction =0.03) and was only observed in participants not taking antihypertensives. Specifically, in those not taking antihypertensive medication, reduced BRS was associated with a higher risk of dementia (adjusted hazard ratio comparing bottom versus top quintiles, 1.60 [95% CI, 1.07–2.40]; P trend =0.02). Reduced BRS was also associated with an increased risk of death (corresponding hazard ratio, 1.76 [95% CI, 1.32–2.35]). The association remained after adjusting for average BP and BP variability. CONCLUSIONS: Impaired BRS partly explains hypertension-related brain damage and excessive dementia risk beyond conventional BP measures, making it a potential novel biomarker for the early detection and prevention of dementia.
- Open Access
- 16 January 2025
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 33 (7) , 1116-1124
Autonomic cardiac control independently predicts incident hypertension and systolic blood pressure in a multi-ethnic population: the HELIUS study
Aims: Cross-correlation baroreflex sensitivity (xBRS) and heart rate variability (HRV) are measures of autonomic cardiac control and are associated with hypertension. However, their value in predicting new-onset hypertension and changes in systolic blood pressure (SBP) remains elusive. Methods and results: We used longitudinal data of participants with and without a history of cardiovascular disease from the HEalthy Life In an Urban Setting (HELIUS) study. A non-invasive continuous finger blood pressure measurement at baseline was used to calculate xBRS and HRV. In normotensives at baseline, we calculated the odds ratio (OR) of developing hypertension at follow-up. In the full cohort, we assessed the change in SBP between baseline and follow-up using linear regression. Subgroup analyses were performed in the younger (<50 years) and older (≥50 years) participants. Median follow-up was 6.6 years (interquartile range 5.8–7.4). A 50% lower xBRS at baseline was independently associated with a 1.31 higher OR [95% confidence interval (CI) 1.09–1.57] of developing hypertension at follow-up. No significant associations between the standard deviation of the normal-to-normal interval (SDNN) or the square root of the mean of successive differences between adjacent normal-to-normal intervals (RMSSD), and new-onset hypertension were found. Compared to the lowest tertile, an xBRS in the highest tertile was associated with a 3.61 mmHg (95% CI 2.50–4.71) higher increase in SBP over time, whereas this was 1.11 mmHg (95% CI 0.12–2.09) and 1.76 mmHg (95% CI 0.73–2.79) for SDNN and RMSSD. Conclusion: In the general population, a lower xBRS is associated with increased odds of developing hypertension, and a steeper increase in SBP over time.
- 16 January 2025
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 33 (7) , 1116-1124
Open AccessAutonomic cardiac control independently predicts incident hypertension and systolic blood pressure in a multi-ethnic population: the HELIUS study
Aims: Cross-correlation baroreflex sensitivity (xBRS) and heart rate variability (HRV) are measures of autonomic cardiac control and are associated with hypertension. However, their value in predicting new-onset hypertension and changes in systolic blood pressure (SBP) remains elusive. Methods and results: We used longitudinal data of participants with and without a history of cardiovascular disease from the HEalthy Life In an Urban Setting (HELIUS) study. A non-invasive continuous finger blood pressure measurement at baseline was used to calculate xBRS and HRV. In normotensives at baseline, we calculated the odds ratio (OR) of developing hypertension at follow-up. In the full cohort, we assessed the change in SBP between baseline and follow-up using linear regression. Subgroup analyses were performed in the younger (<50 years) and older (≥50 years) participants. Median follow-up was 6.6 years (interquartile range 5.8–7.4). A 50% lower xBRS at baseline was independently associated with a 1.31 higher OR [95% confidence interval (CI) 1.09–1.57] of developing hypertension at follow-up. No significant associations between the standard deviation of the normal-to-normal interval (SDNN) or the square root of the mean of successive differences between adjacent normal-to-normal intervals (RMSSD), and new-onset hypertension were found. Compared to the lowest tertile, an xBRS in the highest tertile was associated with a 3.61 mmHg (95% CI 2.50–4.71) higher increase in SBP over time, whereas this was 1.11 mmHg (95% CI 0.12–2.09) and 1.76 mmHg (95% CI 0.73–2.79) for SDNN and RMSSD. Conclusion: In the general population, a lower xBRS is associated with increased odds of developing hypertension, and a steeper increase in SBP over time.
- Open Access
- 1 December 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (12) , 121001
Developing technologies to assess vascular ageing: a roadmap from VascAgeNet
Vascular ageing (vascular ageing) is the deterioration of arterial structure and function which occurs naturally with age, and which can be accelerated with disease. Measurements of vascular ageing are emerging as markers of cardiovascular risk, with potential applications in disease diagnosis and prognosis, and for guiding treatments. However, vascular ageing is not yet routinely assessed in clinical practice. A key step towards this is the development of technologies to assess vascular ageing. In this Roadmap, experts discuss several aspects of this process, including: measurement technologies; the development pipeline; clinical applications; and future research directions. The Roadmap summarises the state of the art, outlines the major challenges to overcome, and identifies potential future research directions to address these challenges.
- 1 December 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (12) , 121001
Open AccessDeveloping technologies to assess vascular ageing: a roadmap from VascAgeNet
Vascular ageing (vascular ageing) is the deterioration of arterial structure and function which occurs naturally with age, and which can be accelerated with disease. Measurements of vascular ageing are emerging as markers of cardiovascular risk, with potential applications in disease diagnosis and prognosis, and for guiding treatments. However, vascular ageing is not yet routinely assessed in clinical practice. A key step towards this is the development of technologies to assess vascular ageing. In this Roadmap, experts discuss several aspects of this process, including: measurement technologies; the development pipeline; clinical applications; and future research directions. The Roadmap summarises the state of the art, outlines the major challenges to overcome, and identifies potential future research directions to address these challenges.
- Top Cited PapersOpen Access
- 1 July 2023
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 325 (1) , H1-H29
Arterial pulse wave modeling and analysis for vascular-age studies: a review from VascAgeNet
Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals contain a wealth of information on the cardiovascular (CV) system that can be exploited to assess vascular age and identify individuals at elevated CV risk. We review the possibilities, limitations, complementarity, and differences of reduced-order, biophysical models of arterial PW propagation, as well as theoretical and empirical methods for analyzing PW signals and extracting clinically relevant information for vascular age assessment. We provide detailed mathematical derivations of these models and theoretical methods, showing how they are related to each other. Finally, we outline directions for future research to realize the potential of modeling and analysis of PW signals for accurate assessment of vascular age in both the clinic and in daily life.
- 1 July 2023
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 325 (1) , H1-H29
Top Cited PapersOpen AccessArterial pulse wave modeling and analysis for vascular-age studies: a review from VascAgeNet
Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals contain a wealth of information on the cardiovascular (CV) system that can be exploited to assess vascular age and identify individuals at elevated CV risk. We review the possibilities, limitations, complementarity, and differences of reduced-order, biophysical models of arterial PW propagation, as well as theoretical and empirical methods for analyzing PW signals and extracting clinically relevant information for vascular age assessment. We provide detailed mathematical derivations of these models and theoretical methods, showing how they are related to each other. Finally, we outline directions for future research to realize the potential of modeling and analysis of PW signals for accurate assessment of vascular age in both the clinic and in daily life.
- 1 February 2023
- Published by Wolters Kluwer Health in Hypertension
- Vol. 80 (2) , 316-324
Sex Differences in Blood Pressure and Potential Implications for Cardiovascular Risk Management
Background: Accurate blood pressure (BP) measurement is critical for optimal cardiovascular risk management. Age-related trajectories for cuff-measured BP accelerate faster in women compared with men, but whether cuff BP represents the intraarterial (invasive) aortic BP is unknown. This study aimed to determine the sex differences between cuff BP, invasive aortic BP, and the difference between the 2 measurements. Methods: Upper-arm cuff BP and invasive aortic BP were measured during coronary angiography in 1615 subjects from the Invasive Blood Pressure Consortium Database. This analysis comprised 22 different cuff BP devices from 28 studies. Results: Subjects were 64±11 years (range 40–89) and 32% women. For the same cuff systolic BP (SBP), invasive aortic SBP was 4.4 mm Hg higher in women compared with men. Cuff and invasive aortic SBP were higher in women compared with men, but the sex difference was more pronounced from invasive aortic SBP, was the lowest in younger ages, and the highest in older ages. Cuff diastolic blood pressure overestimated invasive diastolic blood pressure in both sexes. For cuff and invasive diastolic blood pressure separately, there were sex*age interactions in which diastolic blood pressure was higher in younger men and lower in older men, compared with women. Cuff pulse pressure underestimated invasive aortic pulse pressure in excess of 10 mm Hg for both sexes in older age. Conclusions: For the same cuff SBP, invasive aortic SBP was higher in women compared with men. How this translates to cardiovascular risk prediction needs to be determined, but women may be at higher BP-related risk than estimated by cuff measurements.
- 1 February 2023
- Published by Wolters Kluwer Health in Hypertension
- Vol. 80 (2) , 316-324
Sex Differences in Blood Pressure and Potential Implications for Cardiovascular Risk Management
Background: Accurate blood pressure (BP) measurement is critical for optimal cardiovascular risk management. Age-related trajectories for cuff-measured BP accelerate faster in women compared with men, but whether cuff BP represents the intraarterial (invasive) aortic BP is unknown. This study aimed to determine the sex differences between cuff BP, invasive aortic BP, and the difference between the 2 measurements. Methods: Upper-arm cuff BP and invasive aortic BP were measured during coronary angiography in 1615 subjects from the Invasive Blood Pressure Consortium Database. This analysis comprised 22 different cuff BP devices from 28 studies. Results: Subjects were 64±11 years (range 40–89) and 32% women. For the same cuff systolic BP (SBP), invasive aortic SBP was 4.4 mm Hg higher in women compared with men. Cuff and invasive aortic SBP were higher in women compared with men, but the sex difference was more pronounced from invasive aortic SBP, was the lowest in younger ages, and the highest in older ages. Cuff diastolic blood pressure overestimated invasive diastolic blood pressure in both sexes. For cuff and invasive diastolic blood pressure separately, there were sex*age interactions in which diastolic blood pressure was higher in younger men and lower in older men, compared with women. Cuff pulse pressure underestimated invasive aortic pulse pressure in excess of 10 mm Hg for both sexes in older age. Conclusions: For the same cuff SBP, invasive aortic SBP was higher in women compared with men. How this translates to cardiovascular risk prediction needs to be determined, but women may be at higher BP-related risk than estimated by cuff measurements.
- 30 August 2022
- Published by Wiley in The Journal of Physiology
- Vol. 600 (18) , 4045-4050
The nature of waves in the arteries in memoriam: Nico Westerhof and John Tyberg
This memorial remembers the lives of two distinguished researchers who made major contributions to cardiovascular physiology; NicoWesterhof (1937-2022) and John Tyberg (1938-2022). It is a joint memorial not because they collaborated closely but because they held very different views about the nature of waves in the arteries. Their papers and particularly their lively discussions at many scientific meetings stimulated interest in the subject. Both were thoughtful and articulate about their views, and the debates were polite and dignified. They never resolved their differences and, after outlining what these differences were, we will suggest that perhaps there is no resolution. The authors of this memorial were close to one or the other protagonist; a son, a son-in-law and two close collaborators. We all have different views about the nature of waves in the arteries, but we all share great respect for both men and felt that a joint memorial was a fitting way to remember them and their many contributions. All of the authors knew the subjects of this memorial as 'Nico' and 'John', and we will use these informal names throughout.
- 30 August 2022
- Published by Wiley in The Journal of Physiology
- Vol. 600 (18) , 4045-4050
The nature of waves in the arteries in memoriam: Nico Westerhof and John Tyberg
This memorial remembers the lives of two distinguished researchers who made major contributions to cardiovascular physiology; NicoWesterhof (1937-2022) and John Tyberg (1938-2022). It is a joint memorial not because they collaborated closely but because they held very different views about the nature of waves in the arteries. Their papers and particularly their lively discussions at many scientific meetings stimulated interest in the subject. Both were thoughtful and articulate about their views, and the debates were polite and dignified. They never resolved their differences and, after outlining what these differences were, we will suggest that perhaps there is no resolution. The authors of this memorial were close to one or the other protagonist; a son, a son-in-law and two close collaborators. We all have different views about the nature of waves in the arteries, but we all share great respect for both men and felt that a joint memorial was a fitting way to remember them and their many contributions. All of the authors knew the subjects of this memorial as 'Nico' and 'John', and we will use these informal names throughout.
- 11 July 2022
- Published by Wiley in The Journal of Physiology
- Vol. 600 (15) , 3635
Reply from Masafumi Fukumitsu, Anton Vonk Noordegraaf and Berend E. Westerhof
- 11 July 2022
- Published by Wiley in The Journal of Physiology
- Vol. 600 (15) , 3635
Reply from Masafumi Fukumitsu, Anton Vonk Noordegraaf and Berend E. Westerhof
- Open Access
- 27 April 2022
- Published by Wiley in The Journal of Physiology
- Vol. 600 (10) , 2327-2344
When right ventricular pressure meets volume: The impact of arrival time of reflected waves on right ventricle load in pulmonary arterial hypertension
Right ventricular (RV) wall tension in pulmonary arterial hypertension (PAH) is determined not only by pressure, but also by RV volume. A larger volume at a given pressure generates more wall tension. Return of reflected waves early after the onset of contraction, when RV volume is larger, may augment RV load. We aimed to elucidate: (1) the distribution of arrival times of peak reflected waves in treatment‐naïve PAH patients; (2) the relationship between time of arrival of reflected waves and RV morphology; and (3) the effect of PAH treatment on the arrival time of reflected waves. Wave separation analysis was conducted in 68 treatment‐naïve PAH patients. In the treatment‐naïve condition, 54% of patients had mid‐systolic return of reflected waves (defined as 34–66% of systole). Despite similar pulmonary vascular resistance (PVR), patients with mid‐systolic return had more pronounced RV hypertrophy compared to those with late‐systolic or diastolic return (RV mass/body surface area; mid‐systolic return 54.6 ± 12.6 g m–2, late‐systolic return 44.4 ± 10.1 g m–2, diastolic return 42.8 ± 13.1 g m–2). Out of 68 patients, 43 patients were further examined after initial treatment. At follow‐up, the stiffness of the proximal arteries, given as characteristic impedance, decreased from 0.12 to 0.08 mmHg s mL–1. Wave speed was attenuated from 13.3 to 9.1 m s–1, and the return of reflected waves was delayed from 64% to 71% of systole. In conclusion, reflected waves arrive at variable times in PAH. Early return of reflected waves was associated with more RV hypertrophy. PAH treatment not only decreased PVR, but also delayed the timing of reflected waves.Key points: Right ventricular (RV) wall tension in pulmonary arterial hypertension (PAH) is determined not only by pressure, but also by RV volume. Larger volume at a given pressure causes larger RV wall tension. Early return of reflected waves adds RV pressure in early systole, when RV volume is relatively large. Thus, early return of reflected waves may increase RV wall tension. Wave reflection can provide a description of RV load. In PAH, reflected waves arrive back at variable times. In over half of PAH patients, the RV is exposed to mid‐systolic return of reflected waves. Mid‐systolic return of reflected waves is related to RV hypertrophy. PAH treatment acts favourably on the RV not only by reducing resistance, but also by delaying the return of reflected waves. Arrival timing of reflected waves is an important parameter for understanding the relationship between RV load and its function in PAH.
- 27 April 2022
- Published by Wiley in The Journal of Physiology
- Vol. 600 (10) , 2327-2344
Open AccessWhen right ventricular pressure meets volume: The impact of arrival time of reflected waves on right ventricle load in pulmonary arterial hypertension
Right ventricular (RV) wall tension in pulmonary arterial hypertension (PAH) is determined not only by pressure, but also by RV volume. A larger volume at a given pressure generates more wall tension. Return of reflected waves early after the onset of contraction, when RV volume is larger, may augment RV load. We aimed to elucidate: (1) the distribution of arrival times of peak reflected waves in treatment‐naïve PAH patients; (2) the relationship between time of arrival of reflected waves and RV morphology; and (3) the effect of PAH treatment on the arrival time of reflected waves. Wave separation analysis was conducted in 68 treatment‐naïve PAH patients. In the treatment‐naïve condition, 54% of patients had mid‐systolic return of reflected waves (defined as 34–66% of systole). Despite similar pulmonary vascular resistance (PVR), patients with mid‐systolic return had more pronounced RV hypertrophy compared to those with late‐systolic or diastolic return (RV mass/body surface area; mid‐systolic return 54.6 ± 12.6 g m–2, late‐systolic return 44.4 ± 10.1 g m–2, diastolic return 42.8 ± 13.1 g m–2). Out of 68 patients, 43 patients were further examined after initial treatment. At follow‐up, the stiffness of the proximal arteries, given as characteristic impedance, decreased from 0.12 to 0.08 mmHg s mL–1. Wave speed was attenuated from 13.3 to 9.1 m s–1, and the return of reflected waves was delayed from 64% to 71% of systole. In conclusion, reflected waves arrive at variable times in PAH. Early return of reflected waves was associated with more RV hypertrophy. PAH treatment not only decreased PVR, but also delayed the timing of reflected waves.Key points: Right ventricular (RV) wall tension in pulmonary arterial hypertension (PAH) is determined not only by pressure, but also by RV volume. Larger volume at a given pressure causes larger RV wall tension. Early return of reflected waves adds RV pressure in early systole, when RV volume is relatively large. Thus, early return of reflected waves may increase RV wall tension. Wave reflection can provide a description of RV load. In PAH, reflected waves arrive back at variable times. In over half of PAH patients, the RV is exposed to mid‐systolic return of reflected waves. Mid‐systolic return of reflected waves is related to RV hypertrophy. PAH treatment acts favourably on the RV not only by reducing resistance, but also by delaying the return of reflected waves. Arrival timing of reflected waves is an important parameter for understanding the relationship between RV load and its function in PAH.