JBJoana Goulão Barros

Joana Goulão Barros

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joana Goulão Barros has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Luís M. Graça

    Faculty of Medicine University of Lisbon Lisbon Portugal

    4 shared publications
  • Nuno Clode

    Department of Obstetrics and Gynecology Santa Maria University Hospital Lisbon Portugal

    4 shared publications
  • Ana I. Carita

    Faculty of Human Motricity University of Lisbon Interdisciplinary Center of Human Perfomance Biolad Lisbon Portugal

    2 shared publications
  • Diogo Ayres‐De‐Campos

    Medical School – Santa Maria Hospital University of Lisbon Portugal

    2 shared publications
  • Inês Reis

    Hospital Universitário de Santa Maria, Centro Hospitalar Lisboa Norte, Lisboa, Portugal

    2 shared publications
  • Maria Afonso

    Department of Obstetrics and Gynecology Santa Maria University Hospital Lisbon Portugal

    2 shared publications

Latest Publications

  • Open Access

    Da Preconceção à Amamentação: O que Pensam os Profissionais de Saúde e as Mulheres sobre a Suplementação Vitamínica

    by Mafalda Simões, Filomena Sousa, Joana Goulão Barros, Ana Costa, Teresa Bombas

    Na gravidez, os hábitos saudáveis, como uma dieta equilibrada e suplementação vitamínica, são essenciais para a saúde materno-fetal. As deficiências nutricionais podem causar malformações fetais, sendo que organizações como a Direção-Geral da Saúde recomendam a suplementação com ácido fólico e iodo. Contudo, as diretrizes para outros micronutrientes, como o ferro e o zinco, são menos claras, gerando dúvidas entre profissionais de saúde. Um estudo descritivo realizado entre março e agosto de 2023 avaliou a perceção de médicos, farmacêuticos e mulheres sobre a suplementação. Entre os 230 médicos entrevistados, 89,1% destacaram a importância da consulta pré-concecional, sendo o ácido fólico o suplemento mais recomendado. Na gravidez, 81,7% prescreveram ácido fólico, 49,6% ferro e 60,4% iodo. Contudo, apenas dois terços das mulheres relataram suplementação no pós-parto, evidenciando uma lacuna nos cuidados nesta fase. Entre os 433 farmacêuticos, 48% acreditam na necessidade de maior intervenção no aconselhamento sobre suplementação, especialmente no pós-parto, quando a procura por informações aumenta. Das 1107 mulheres inquiridas, 49% não realizaram consulta pré-concecional, muitas vezes obtendo informações de fontes informais, o que prejudica a adesão às recomendações médicas. Apesar da alta adesão à suplementação na gravidez, fatores como o custo e o receio de efeitos adversos ainda são barreiras. É essencial melhorar o aconselhamento antes, durante e após a gravidez, com estratégias personalizadas que envolvam médicos, farmacêuticos e programas comunitários, visando melhores resultados materno-fetais.

  • Routine Ultrasound at 30th–33rd weeks versus 30th–33rd and 35th–37th weeks in Low-Risk Pregnancies: A Randomized Trial

    by Catarina Policiano, Jorge M. Mendes, Andreia Fonseca, Joana Barros, Sara Vargas, Margarida Cal, Inês Martins, Catarina Carvalho, Diana Martins, Nuno Clode, et al.

    Introduction: The aim of this study was to evaluate the accuracy of 35–37 weeks’ ultrasound for fetal growth restriction (FGR) detection and the impact of 30th–33rd weeks versus 30th–33rd and 35th–37th weeks’ ultrasound on perinatal outcomes. Methods: This was a randomized controlled trial that enrolled 1,061 low-risk pregnant women: 513 in the control group (routine ultrasound performed at 30th–33rd weeks) and 548 in the study group (with an additional ultrasound at 35th–37th weeks). FGR was defined as a fetus with an estimated fetal weight (EFW) below the 10th percentile. p values < 0.05 were considered statistically significant. Results: The ultrasound at 35–37 weeks had an overall accuracy of FGR screening of 94%. Spearman’s correlation coefficient between EFW and birthweight centile was higher for at 35–37 weeks’ ultrasound (ρ = 0.75) compared with 30–33 weeks’ ultrasound (ρ = 0.44). The study group had a lower rate of operative vaginal deliveries (24.4% vs. 39.3%, p = 0.005) and cesarean deliveries for nonreassuring fetal status (16.8% vs. 38.8%, p < 0.001). Discussion/Conclusion: A later ultrasound (35–37 weeks) had a high accuracy for detection of FGR and had a higher correlation between EFW and birthweight centiles. Furthermore, it was also associated with lower adverse perinatal outcomes compared to an earlier ultrasound.


  • Sonographic knowledge of occiput position to decrease failed operative vaginal delivery: a systematic review and meta-analysis of randomized controlled trials

    by Federica Bellussi, Daniele Di Mascio, Ginevra Salsi, Tullio Ghi, Andrea Dall’aSta, Fabrizio Zullo, Gianluigi Pilu, Joana G. Barros, Diogo Ayres-De-Campos, Vincenzo Berghella


  • Open Access

    Satisfaction of Pregnant Women in an Obstetric Ultrasound Unit During the COVID-19 Pandemic

    by Joana Bernardeco, Rita Silva, Sara Pereira, Joana Barros, Rui Carvalho

    Satisfaction of Pregnant Women in an Obstetric Ultrasound Unit During the COVID-19 Pandemic

  • Transabdominal and transperineal ultrasound vs routine care before instrumental vaginal delivery – A randomized controlled trial

    by Joana G. Barros, Maria Afonso, Ana T. Martins, Ana I. Carita, Nuno Clode, Diogo Ayres‐De‐Campos, Luís M. Graça

    Introduction: The role of intrapartum ultrasound as an ancillary method to instrumental vaginal delivery is yet to be determined. This study aimed to compare the use of transabdominal and transperineal ultrasound with routine clinical care before performing an instrumental vaginal delivery, regarding the incidence of adverse maternal and neonatal outcomes.Material and Methods: A randomized controlled trial was conducted between October 2016 and March 2019 in two tertiary care maternity hospitals in Lisbon, Portugal. Women at term, with full cervical dilatation, singleton fetuses in cephalic presentation, and with an established indication for instrumental vaginal delivery, were approached for enrollment. After informed consent was obtained, randomization into one of two groups was carried out. In the experimental arm, women underwent transabdominal ultrasound for determination of the fetal head position and transperineal ultrasound for evaluation of the angle of progression, before instrumental vaginal delivery. In the control arm, no ultrasound was carried out before instrumental vaginal delivery. Primary outcomes were composite measures of maternal and neonatal morbidity. Composite maternal morbidity consisted of severe postpartum hemorrhage, perineal trauma, and prolonged hospital stay. Composite neonatal morbidity consisted of low 5‐minute Apgar score, umbilical artery metabolic acidosis, birth trauma, and neonatal intensive care unit admission.Results: A total of 222 women were enrolled (113 in the experimental arm and 109 in the control arm). No significant differences between the two arms were found in composite measures of maternal (23.9% in the experimental group vs 22.9% in the control group, odds ratio 1.055, 95% CI 0.567‐1.964) or neonatal morbidity (9.7% in the experimental group vs 6.4% in the control group, odds ratio 1.571, 95% CI 0.586‐4.215), nor in any of the individual outcomes.Conclusions: In this small randomized controlled trial that was stopped for futility before reaching the required sample size, transabdominal and transperineal ultrasound performed just before instrumental vaginal delivery did not reduce the incidence of adverse maternal and neonatal outcomes, when compared with routine clinical care.


  • Effect of simulation-based training on the accuracy of fetal head position determination in labor

    by Joana G Barros, Ana Gomes-Da-Costa, Maria Afonso, Ana I. Carita, Diogo Ayres-De-Campos, Luís M. Graça, Nuno Clode


  • Open Access

    Prevalence of Late Preterm and Early Term Birth in Portugal

    by Joana Goulão Barros, Nuno Clode, Luís M. Graça

    Introduction: Late preterm birth (defined as birth between 34 and 36 complete weeks’ gestation) and early term birth (defined as birth between 37 and 38 complete weeks’ gestation) have become a topic of recent discussion as the morbidity associated with delivery at these gestational ages has become increasingly evident. Our objective was to evaluate the characteristics of late preterm and early term birth in Portugal. Material and Methods: We developed a survey questionnaire that was sent to the Obstetric Department of all public hospitals in Portugal. The questionnaire consisted on questions on prevalence and mode of delivery of late preterm and early term period and associated neonatal morbidity and mortality. The questions referred solely to single births occurred during 2013. Results: We received completed questionnaires from 14 hospitals, corresponding to nearly one third (33.5%) of total deliveries in Portugal. We report 5.4% of late preterm and 27% of early term deliveries. Approximately two thirds of late preterm and three quarters of early term deliveries were spontaneous. The cesarean section rate was higher in late preterm (39.1%) than in early term (26.4%) births. Neonatal complications were more frequent in late preterm neonates (34.2%) when compared to early term neonates (14.2%). Discussion: The prevalence of late preterm and early term birth in our cohort is comparable, although slightly reduced, to other published series. Conclusion: The obstetric community should raise efforts to limit deliveries below 39 weeks’ gestation to the ones with a valid medical indication.


  • Open Access

    Estimation of Fetal Weight during Labor: Still a Challenge

    by Inês Reis, Isabel Pereira, Nuno Clode, Luís M. Graça, Joana Goulão Barros

    Objective To evaluate the accuracy of fetal weight prediction by ultrasonography labor employing a formula including the linear measurements of femur length (FL) and mid-thigh soft-tissue thickness (STT). Methods We conducted a prospective study involving singleton uncomplicated term pregnancies within 48 hours of delivery. Only pregnancies with a cephalic fetus admitted in the labor ward for elective cesarean section, induction of labor or spontaneous labor were included. We excluded all non-Caucasian women, the ones previously diagnosed with gestational diabetes and the ones with evidence of ruptured membranes. Fetal weight estimates were calculated using a previously proposed formula [estimated fetal weight = − 1687.47 + (54.1 × FL) + (76.68 × STT). The relationship between actual birth weight and estimated fetal weight was analyzed using Pearson's correlation. The formula's performance was assessed by calculating the signed and absolute errors. Mean weight difference and signed percentage error were calculated for birth weight divided into three subgroups: < 3000 g; 3000–4000g; and > 4000 g. Results We included for analysis 145 cases and found a significant, yet low, linear relationship between birth weight and estimated fetal weight (p < 0.001; R2 = 0.197) with an absolute mean error of 10.6%. The lowest mean percentage error (0.3%) corresponded to the subgroup with birth weight between 3000 g and 4000 g. Conclusions This study demonstrates a poor correlation between actual birth weight and the estimated fetal weight using a formula based on femur length and mid-thigh soft-tissue thickness, both linear parameters. Although avoidance of circumferential ultrasound measurements might prove to be beneficial, it is still yet to be found a fetal estimation formula that can be both accurate and simple to perform. Objetivo Avaliar a precisão da determinação ultrassonográfica da estimativa de peso fetal recorrendo apenas a parâmetros lineares (comprimento do fémur – FL - e espessura de tecido mole a meio da coxa fetal - STT), no período precedente ao parto. Métodos Realizamos um estudo prospectivo que incluiu gestações simples de termo, com feto cefálico, nas quais o parto ocorreu nas 48h seguintes à avaliação ecográfica. A inclusão no estudo foi feita no momento de admissão ao bloco de partos para cesariana eletiva, indução do trabalho de parto ou trabalho de parto espontâneo. Foram excluídas todas as grávidas não caucasianas, com diagnóstico de diabetes gestacional ou evidência de rotura de membranas. A estimativa de peso fetal foi calculada através de uma fórmula previamente publicada [estimativa de peso fetal = − 1687,47 + (54,1 × FL) + (76,68 × STT). A relação entre o peso real e o peso estimado foi analisada através da correlação de Pearson. O desempenho desta fórmula foi avaliado através do cálculo da percentagem de erro absoluto e não absoluto. Os recém-nascidos foram divididos em 3 grupos consoante o peso real: < 3000 g; 3000 g – 4000 g; e > 4000 g; para cada grupo foi calculada diferença média entre a estimativa de peso e o peso real e a percentagem de erro associada. Resultados Incluímos 145 casos no estudo, cuja estimativa de peso e peso real se correlacionaram significativamente, apesar do valor de correlação ser pouco elevado (p < 0,001; R2 = 0,197). Globalmente, a percentagem de erro absoluto foi 10,6%. A percentagem de erro mais baixa correspondeu ao grupo com peso real entre 3000 g e 4000 g. Conclusões Com este estudo demonstramos uma correlação fraca entre o peso real e a estimativa de peso fetal ultrassonográfica, quando calculada com base numa fórmula que usa o comprimento do fémur e a espessura de tecido mole a meio da coxa fetal, ambos parâmetros lineares. Ainda que a exclusão de parâmetros circunferenciais no cálculo da estimativa de peso fetal se venha a provar benéfica, esta não parece ser uma fórmula simultaneamente simples e precisa no cálculo da estimativa de peso fetal.