Lennart van de Velde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lennart van de Velde has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Erik Groot Jebbink
Multi-Modality Medical Imaging Group, University of Twente, Enschede, The Netherlands
8 shared publications - Michel Versluis
Physics of Fluids group, TechMed Centre, University of Twente, Enschede, The Netherlands
7 shared publications - Michel M. P. J. Reijnen
Department of Surgery, Rijnstate Hospital, Arnhem, the Netherlands
6 shared publications - Didier Collard
Department of Vascular Medicine, AmsterdamUMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands
4 shared publications Michel M. P. J. Reijnen
Multi-Modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
4 shared publicationsMichel Versluis
Physics of Fluids Group, Technical Medical Center and MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
4 shared publications
Latest Publications
- Open Access
Validation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosis
Objectives: To validate two computational fluid dynamics (CFD) models derived from computed tomography angiography (CTA) for estimating trans-stenotic pressure gradients, using invasive intra-arterial pressure measurements as the reference standard in patients with renal artery stenosis (RAS). Background: We assessed whether non-invasive assessment of the pressure gradient using CFD could be a reliable alternative to intra-arterial measurements for identifying hemodynamically significant RAS. Methods: We performed intra-arterial measurements at rest and during dopamine-induced hyperemia to assess the trans-stenotic pressure gradient in 28 patients with RAS. A pre-intervention CTA scan was used to simulate the pressure gradient with a CFD model using a strategy based on Murray’s law (CFD-Mu) and cortical volume (CFD-C). The agreement between the simulated and measured pressure gradients was assessed using intraclass correlation coefficients (ICC), Bland-Altman analysis and diagnostic agreement on the presence of a hemodynamically significant stenosis. Results: In 20 patients, successful measurements and simulations were obtained. The ICC between measured pressure gradient and the CFD pressure gradient was 0.78 and 0.94 during baseline and 0.86 and 0.72 during hyperemia, for CFD-Mu and CFD-C, respectively. The sensitivity of CFD-Mu and CFD-C was 70% for both models at rest and 100% compared to the hyperemic measurements, whereas the specificity was 90% and 70% at rest and 79% and 72% during hyperemia, respectively. Conclusions: The results support the use of individualized CFD simulations for hemodynamic assessment of RAS using CTA as input. The CFD models demonstrated high accuracy for the identification of a hemodynamically significant stenosis.
Open AccessValidation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosis
Objectives: To validate two computational fluid dynamics (CFD) models derived from computed tomography angiography (CTA) for estimating trans-stenotic pressure gradients, using invasive intra-arterial pressure measurements as the reference standard in patients with renal artery stenosis (RAS). Background: We assessed whether non-invasive assessment of the pressure gradient using CFD could be a reliable alternative to intra-arterial measurements for identifying hemodynamically significant RAS. Methods: We performed intra-arterial measurements at rest and during dopamine-induced hyperemia to assess the trans-stenotic pressure gradient in 28 patients with RAS. A pre-intervention CTA scan was used to simulate the pressure gradient with a CFD model using a strategy based on Murray’s law (CFD-Mu) and cortical volume (CFD-C). The agreement between the simulated and measured pressure gradients was assessed using intraclass correlation coefficients (ICC), Bland-Altman analysis and diagnostic agreement on the presence of a hemodynamically significant stenosis. Results: In 20 patients, successful measurements and simulations were obtained. The ICC between measured pressure gradient and the CFD pressure gradient was 0.78 and 0.94 during baseline and 0.86 and 0.72 during hyperemia, for CFD-Mu and CFD-C, respectively. The sensitivity of CFD-Mu and CFD-C was 70% for both models at rest and 100% compared to the hyperemic measurements, whereas the specificity was 90% and 70% at rest and 79% and 72% during hyperemia, respectively. Conclusions: The results support the use of individualized CFD simulations for hemodynamic assessment of RAS using CTA as input. The CFD models demonstrated high accuracy for the identification of a hemodynamically significant stenosis.
- Open Access
- 6 August 2026
- Published by Elsevier in JVS-Vascular Science
- Vol. 7
Using patient-specific computational fluid dynamics to assess intraprosthetic thrombus formation risk and guide relining after endovascular aneurysm repair
- 6 August 2026
- Published by Elsevier in JVS-Vascular Science
- Vol. 7
Open AccessUsing patient-specific computational fluid dynamics to assess intraprosthetic thrombus formation risk and guide relining after endovascular aneurysm repair
- Open Access
- 7 July 2026
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 17 (5) , 591-600
Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study
Purpose: Spectral computed tomography derived virtual monoenergetic imaging (VMI) reconstructions have been shown to reduce stent-induced blooming artifacts thus minimizing in-stent lumen underestimation. We have investigated the use of VMI reconstructions to reduce the blooming artifact for stent markers, single and double stent configurations. Methods: Two partially overlapping covered stents were deployed in a superficial femoral artery phantom. A conventional and twelve VMI reconstructions (40–100 keV and 120–200 keV with 10 and 20 keV increments, respectively) were created. Contrast-to-noise ratio, signal-to-noise ratio, attenuation difference between native and in-stent vessel lumen and full width at half maximum (FWHM) of the stent peaks were evaluated. The in-stent lumen diameter was measured, and the stent evaluated using a 5-point scale by three interventional radiologists. Results: The 80–100 keV VMI reconstructions for the single stent configuration and the 140 keV VMI reconstruction for the other configurations resulted in the smallest lumen underestimation and best quality score on blooming. The underestimation was reduced from 21.5–29.1% for the conventional reconstruction to 14.1–18.6% for the optimal VMI reconstructions. No significant differences were observed in FWHM between the conventional reconstruction and the 50–200 keV VMI reconstructions. Conclusions: VMI was found to minimize stent-induced blooming artifacts and improve in-stent lumen assessment. More stent material requires higher-energy VMI reconstructions to reduce blooming. The absence of significant differences in quantitative parameters suggests that the number of pixels affected by the blooming artifact is not reduced using VMI reconstructions.
- 7 July 2026
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 17 (5) , 591-600
Open AccessReducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study
Purpose: Spectral computed tomography derived virtual monoenergetic imaging (VMI) reconstructions have been shown to reduce stent-induced blooming artifacts thus minimizing in-stent lumen underestimation. We have investigated the use of VMI reconstructions to reduce the blooming artifact for stent markers, single and double stent configurations. Methods: Two partially overlapping covered stents were deployed in a superficial femoral artery phantom. A conventional and twelve VMI reconstructions (40–100 keV and 120–200 keV with 10 and 20 keV increments, respectively) were created. Contrast-to-noise ratio, signal-to-noise ratio, attenuation difference between native and in-stent vessel lumen and full width at half maximum (FWHM) of the stent peaks were evaluated. The in-stent lumen diameter was measured, and the stent evaluated using a 5-point scale by three interventional radiologists. Results: The 80–100 keV VMI reconstructions for the single stent configuration and the 140 keV VMI reconstruction for the other configurations resulted in the smallest lumen underestimation and best quality score on blooming. The underestimation was reduced from 21.5–29.1% for the conventional reconstruction to 14.1–18.6% for the optimal VMI reconstructions. No significant differences were observed in FWHM between the conventional reconstruction and the 50–200 keV VMI reconstructions. Conclusions: VMI was found to minimize stent-induced blooming artifacts and improve in-stent lumen assessment. More stent material requires higher-energy VMI reconstructions to reduce blooming. The absence of significant differences in quantitative parameters suggests that the number of pixels affected by the blooming artifact is not reduced using VMI reconstructions.
- Open Access
- 26 April 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (6) , 1190-1198
In Vivo Validation of Computational Fluid Dynamics for Determining the Pressure Gradient for Multi-segmental Femoropopliteal Disease
Purpose: In peripheral arterial disease, the presence of multi-segmental (adjacent) stenotic lesions is common. The application of anatomic grading and duplex ultrasound for defining the significance of multi-segmental lesions is limited. This study aimed to validate computational fluid dynamics (CFD) simulations for estimating the pressure gradient in patients with multi-segmental femoropopliteal disease. Materials and Methods: Fifteen patients scheduled for angiography with multiple lesions in the femoropopliteal artery were prospectively enrolled. Pressures were recorded in rest and after papaverine administration using sheath and pressure-wire measurements. The resting pressure gradient of the full segment and the fractional flow reserve (FFR) of the full segment and individual lesions were calculated. These metrics were noninvasively replicated by CTA-based CFD using a reference flow rate (CFDm) and a duplex ultrasound-derived flow rate (CFDi). The agreement and diagnostic accuracy of CFD for identifying hemodynamic significance was assessed. Results: CFDm underestimated the pressure gradient by − 4.0 ± 6.2 mmHg (mean ± SD). CFDi closely approximated the measured gradient with a 0.1 ± 3.1 mmHg difference. The full-segment FFR had a − 0.02 ± 0.06 difference and the individual-lesion FFR had a 0.01 ± 0.06 difference relative to the measured FFR. The diagnostic accuracy of CFD for the resting pressure gradient was 73% (CFDi) and 80% (CFDm). CFD demonstrated a diagnostic accuracy of 89% for full-vessel FFR and 83% for individual-lesion FFR. Conclusion: The results provide proof-of-concept validation for the use of CFD for noninvasive assessment of multi-segmental femoropopliteal disease. This could guide the treatment plan of multi-segmental PAD. Level of Evidence : Level 3b, Individual case–control study.
- 26 April 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (6) , 1190-1198
Open AccessIn Vivo Validation of Computational Fluid Dynamics for Determining the Pressure Gradient for Multi-segmental Femoropopliteal Disease
Purpose: In peripheral arterial disease, the presence of multi-segmental (adjacent) stenotic lesions is common. The application of anatomic grading and duplex ultrasound for defining the significance of multi-segmental lesions is limited. This study aimed to validate computational fluid dynamics (CFD) simulations for estimating the pressure gradient in patients with multi-segmental femoropopliteal disease. Materials and Methods: Fifteen patients scheduled for angiography with multiple lesions in the femoropopliteal artery were prospectively enrolled. Pressures were recorded in rest and after papaverine administration using sheath and pressure-wire measurements. The resting pressure gradient of the full segment and the fractional flow reserve (FFR) of the full segment and individual lesions were calculated. These metrics were noninvasively replicated by CTA-based CFD using a reference flow rate (CFDm) and a duplex ultrasound-derived flow rate (CFDi). The agreement and diagnostic accuracy of CFD for identifying hemodynamic significance was assessed. Results: CFDm underestimated the pressure gradient by − 4.0 ± 6.2 mmHg (mean ± SD). CFDi closely approximated the measured gradient with a 0.1 ± 3.1 mmHg difference. The full-segment FFR had a − 0.02 ± 0.06 difference and the individual-lesion FFR had a 0.01 ± 0.06 difference relative to the measured FFR. The diagnostic accuracy of CFD for the resting pressure gradient was 73% (CFDi) and 80% (CFDm). CFD demonstrated a diagnostic accuracy of 89% for full-vessel FFR and 83% for individual-lesion FFR. Conclusion: The results provide proof-of-concept validation for the use of CFD for noninvasive assessment of multi-segmental femoropopliteal disease. This could guide the treatment plan of multi-segmental PAD. Level of Evidence : Level 3b, Individual case–control study.
- Open Access
- 17 January 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 277, 109259
Effect of Doppler ultrasound and high-frame-rate ultrasound particle image velocimetry derived inlet boundary conditions on wall shear stress parameters in the stented superficial femoral artery
- 17 January 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 277, 109259
Open AccessEffect of Doppler ultrasound and high-frame-rate ultrasound particle image velocimetry derived inlet boundary conditions on wall shear stress parameters in the stented superficial femoral artery
- Open Access
- 17 October 2025
- Published by S. Karger AG in Cardiology
- p. 1-2
Toward Quantifying Transitional Blood Flow in Patients
- 17 October 2025
- Published by S. Karger AG in Cardiology
- p. 1-2
Open AccessToward Quantifying Transitional Blood Flow in Patients
- Open Access
- 29 May 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (2) , 949-961
A Systematic Review on the Use of Intravascular Ultrasound and Optical Coherence Tomography During Femoropopliteal Endovascular Intervention
Performing adjunctive intravascular imaging during femoropopliteal endovascular intervention could improve treatment planning and outcome. This systematic review assessed how imaging findings of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) can contribute to improving treatment planning and outcomes of patients with femoropopliteal arterial disease. Scopus and PubMed databases were searched from January 2011 to July 2023 for all studies reporting on the use of IVUS or OCT imaging findings in the treatment of femoropopliteal disease. The effect of IVUS and OCT imaging findings on treatment plan and outcome, as well as the predictive ability of IVUS and OCT for treatment outcome, were analyzed. A total of 42 studies (one randomized‐controlled trial, 17 prospective, 20 retrospective, and four descriptive studies), 34 involving IVUS, seven OCT, and one both, were included. IVUS‐assessed diameters were significantly larger, and lesion length was longer compared to angiography, which affected treatment planning. OCT‐measured diameters were significantly larger than angiography at follow‐up and did not differ significantly from IVUS except for one location. Both IVUS and OCT identified more dissections, calcifications, residual stenoses, and inadequate stent expansion than angiography, impacting treatment planning. IVUS‐assessed imaging findings were associated with reduced restenosis at 1 and 2‐year follow‐up compared to angiography alone, while for OCT, data was limited. IVUS and OCT can visualize complementary imaging features compared to angiography alone that change the treatment plan of patients with femoropopliteal disease, both pre‐ and post‐treatment. IVUS has the potential to improve treatment outcomes, whereas there is still limited evidence for OCT.
- 29 May 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (2) , 949-961
Open AccessA Systematic Review on the Use of Intravascular Ultrasound and Optical Coherence Tomography During Femoropopliteal Endovascular Intervention
Performing adjunctive intravascular imaging during femoropopliteal endovascular intervention could improve treatment planning and outcome. This systematic review assessed how imaging findings of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) can contribute to improving treatment planning and outcomes of patients with femoropopliteal arterial disease. Scopus and PubMed databases were searched from January 2011 to July 2023 for all studies reporting on the use of IVUS or OCT imaging findings in the treatment of femoropopliteal disease. The effect of IVUS and OCT imaging findings on treatment plan and outcome, as well as the predictive ability of IVUS and OCT for treatment outcome, were analyzed. A total of 42 studies (one randomized‐controlled trial, 17 prospective, 20 retrospective, and four descriptive studies), 34 involving IVUS, seven OCT, and one both, were included. IVUS‐assessed diameters were significantly larger, and lesion length was longer compared to angiography, which affected treatment planning. OCT‐measured diameters were significantly larger than angiography at follow‐up and did not differ significantly from IVUS except for one location. Both IVUS and OCT identified more dissections, calcifications, residual stenoses, and inadequate stent expansion than angiography, impacting treatment planning. IVUS‐assessed imaging findings were associated with reduced restenosis at 1 and 2‐year follow‐up compared to angiography alone, while for OCT, data was limited. IVUS and OCT can visualize complementary imaging features compared to angiography alone that change the treatment plan of patients with femoropopliteal disease, both pre‐ and post‐treatment. IVUS has the potential to improve treatment outcomes, whereas there is still limited evidence for OCT.
- Open Access
- 13 October 2024
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (2) , 989-1000
Swirling Flow Quantification in Helical Stents Using Ultrasound Velocimetry
Objective: Helical stents have been developed to treat peripheral arterial disease (PAD) in the superficial femoral artery (SFA), with the premise that their particular geometry could promote swirling flow in the blood. The aim of this work is to provide evidence on the existence of this swirling flow by quantifying its signatures. Materials and Methods: This study consists of in vitro and in vivo parts. For the in vitro part, 3 helical stent models of different helicity degrees and 1 straight model were fabricated, and the flow was assessed at the inlet and outlet of each model. For the in vivo part, only 1 patient, treated with the helical stent, was eligible to participate in the study. The stent implanted in the SFA of the patient was evaluated in 2 leg postures (straight and flexed), and flow was assessed in 12 locations along the SFA. The in vivo study was approved by an ethical board (NL80130.091.21) in the Netherlands. High-frame-rate ultrasound was used to acquire data from the regions of interest (ROIs), using microbubbles as contrast agents. After processing the data via a correlation-based algorithm (echo particle image velocimetry or echoPIV), the velocity vector field within each ROI was extracted and analyzed for parameters such as vector complexity and velocity profile skewedness. Results: The results show that in the outlet of the helical stents, when compared with the inlet, the flow vector field is more complex and the velocity profile is more skewed. For the in vivo case, the outcomes demonstrate more complexity and higher variability in the sign of skewedness inside the stent when compared with the flow in the proximal to the stent. Conclusions: Helical stents make the vector field of the flow more complex and the velocity profile more skewed, both of which are signatures of swirling flow. Further studies are needed to evaluate whether these features can benefit patients in terms of patency rates. Clinical Impact: This study demonstrates that helical stent models alter the blood flow when compared with straight stent models. Particularly, the flow grows more complex and its velocity profile becomes more skewed, both of which hint at the existence of swirling flow inside the helical stent. These observations, alongside with population-based studies that are currently being carried out, may provide the evidence that helical stents have some advantages over straight stents for the patients.
- 13 October 2024
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (2) , 989-1000
Open AccessSwirling Flow Quantification in Helical Stents Using Ultrasound Velocimetry
Objective: Helical stents have been developed to treat peripheral arterial disease (PAD) in the superficial femoral artery (SFA), with the premise that their particular geometry could promote swirling flow in the blood. The aim of this work is to provide evidence on the existence of this swirling flow by quantifying its signatures. Materials and Methods: This study consists of in vitro and in vivo parts. For the in vitro part, 3 helical stent models of different helicity degrees and 1 straight model were fabricated, and the flow was assessed at the inlet and outlet of each model. For the in vivo part, only 1 patient, treated with the helical stent, was eligible to participate in the study. The stent implanted in the SFA of the patient was evaluated in 2 leg postures (straight and flexed), and flow was assessed in 12 locations along the SFA. The in vivo study was approved by an ethical board (NL80130.091.21) in the Netherlands. High-frame-rate ultrasound was used to acquire data from the regions of interest (ROIs), using microbubbles as contrast agents. After processing the data via a correlation-based algorithm (echo particle image velocimetry or echoPIV), the velocity vector field within each ROI was extracted and analyzed for parameters such as vector complexity and velocity profile skewedness. Results: The results show that in the outlet of the helical stents, when compared with the inlet, the flow vector field is more complex and the velocity profile is more skewed. For the in vivo case, the outcomes demonstrate more complexity and higher variability in the sign of skewedness inside the stent when compared with the flow in the proximal to the stent. Conclusions: Helical stents make the vector field of the flow more complex and the velocity profile more skewed, both of which are signatures of swirling flow. Further studies are needed to evaluate whether these features can benefit patients in terms of patency rates. Clinical Impact: This study demonstrates that helical stent models alter the blood flow when compared with straight stent models. Particularly, the flow grows more complex and its velocity profile becomes more skewed, both of which hint at the existence of swirling flow inside the helical stent. These observations, alongside with population-based studies that are currently being carried out, may provide the evidence that helical stents have some advantages over straight stents for the patients.
- Open Access
- 1 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (03) , 037001-21
Validation of ultrasound velocimetry and computational fluid dynamics for flow assessment in femoral artery stenotic disease
Peripheral arterial disease (PAD) is a major cardiovascular disease burden with a global prevalence of 10% to 25% in age groups above 65 years,1 with the femoral artery as a key site of atherosclerotic manifistations.2 It is well known that areas with complex flow structures, such as recirculation zones, induce low and oscillatory wall shear stress (WSS), thereby forming a local risk factor for atherosclerosis.3 Flow disturbances induced by the femoral bifurcation, the triphasic flow waveform including a pronounced backflow phase,4 and the confined anatomic space of the superficial femoral artery (SFA)5 may be the leading causes for the high prevalence of atherosclerotic lesions in this region. The association between adverse flow patterns and the onset and progression of atherosclerosis in patients has so far not been studied in-depth, mainly due to a lack of cost-effective and validated in-vivo flow measurement techniques.
- 1 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (03) , 037001-21
Open AccessValidation of ultrasound velocimetry and computational fluid dynamics for flow assessment in femoral artery stenotic disease
Peripheral arterial disease (PAD) is a major cardiovascular disease burden with a global prevalence of 10% to 25% in age groups above 65 years,1 with the femoral artery as a key site of atherosclerotic manifistations.2 It is well known that areas with complex flow structures, such as recirculation zones, induce low and oscillatory wall shear stress (WSS), thereby forming a local risk factor for atherosclerosis.3 Flow disturbances induced by the femoral bifurcation, the triphasic flow waveform including a pronounced backflow phase,4 and the confined anatomic space of the superficial femoral artery (SFA)5 may be the leading causes for the high prevalence of atherosclerotic lesions in this region. The association between adverse flow patterns and the onset and progression of atherosclerosis in patients has so far not been studied in-depth, mainly due to a lack of cost-effective and validated in-vivo flow measurement techniques.
- Open Access
- 2 April 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (5) , 533-542
Lesion Eccentricity Plays a Key Role in Determining the Pressure Gradient of Serial Stenotic Lesions: Results from a Computational Hemodynamics Study
Purpose: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. Materials and Methods: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid–structure simulations were performed to quantify the combined pressure gradient. Results: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5–24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15–25%. The impact of flow pulsatility and wall deformability was minor. Conclusion: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions. Graphical
- 2 April 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (5) , 533-542
Open AccessLesion Eccentricity Plays a Key Role in Determining the Pressure Gradient of Serial Stenotic Lesions: Results from a Computational Hemodynamics Study
Purpose: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. Materials and Methods: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid–structure simulations were performed to quantify the combined pressure gradient. Results: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5–24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15–25%. The impact of flow pulsatility and wall deformability was minor. Conclusion: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions. Graphical