Alain Girodet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alain Girodet has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Christophe Creusot
SuperGrid Institute, Lyon, France
3 shared publications- Nelly Bonifaci
French National Center for Scientific Research (CNRS), Grenoble Electrical Engineering Laboratory (G2Elab), Grenoble, France
3 shared publications - Olivier Lesaint
French National Center for Scientific Research (CNRS), Grenoble Electrical Engineering Laboratory (G2Elab), Grenoble, France
3 shared publications D. van der Born
DC Systems and Storage, Delft University of Technology, The Netherlands
2 shared publications- Johan J. Smit
TU Delft
2 shared publications Olivier Gallot-Lavallée
Universit Grenoble Alpes (UGA), Grenoble Electrical Engineering Laboratory (G2Elab), Grenoble, France
2 shared publications
Latest Publications
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1681-1689
Pre-Breakdown and Breakdown Phenomena in Liquid Nitrogen With a Tape–Plane Electrode Geometry
Pre-breakdown and breakdown phenomena are investigated in liquid Nitrogen (LN 2 ) with a tape-plane electrode geometry. Different voltage waveforms are used: lightning and switching standard impulses, step impulse, and DC ramp. The influence of temperature is also investigated, by sub-cooling LN 2 down to 65 K. Breakdown voltage depends on polarity, gap distance, temperature, and HV waveform: the longer waveform, the lower breakdown voltage. Positive pre-breakdown streamers are about 3 decades faster than negative ones. With short duration lightning impulses, the propagation of slow negative streamers is quenched, resulting in higher breakdown voltage. In boiling conditions, slow negative streamers may propagate for long durations. Sub-cooling LN 2 induces a slight increase of streamer initiation voltage, and impedes the propagation of slow streamers due to condensation.
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1681-1689
Pre-Breakdown and Breakdown Phenomena in Liquid Nitrogen With a Tape–Plane Electrode Geometry
Pre-breakdown and breakdown phenomena are investigated in liquid Nitrogen (LN 2 ) with a tape-plane electrode geometry. Different voltage waveforms are used: lightning and switching standard impulses, step impulse, and DC ramp. The influence of temperature is also investigated, by sub-cooling LN 2 down to 65 K. Breakdown voltage depends on polarity, gap distance, temperature, and HV waveform: the longer waveform, the lower breakdown voltage. Positive pre-breakdown streamers are about 3 decades faster than negative ones. With short duration lightning impulses, the propagation of slow negative streamers is quenched, resulting in higher breakdown voltage. In boiling conditions, slow negative streamers may propagate for long durations. Sub-cooling LN 2 induces a slight increase of streamer initiation voltage, and impedes the propagation of slow streamers due to condensation.
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1690-1697
Breakdown Phenomena in Liquid Nitrogen Under Synchronized Transient Boiling and Impulse Voltage
Resistive superconducting fault current limiters constitute a promising solution for high voltage networks. During the resistive current limitation, transient overvoltages and heat dissipation occur on superconducting tapes, inducing fast boiling of surrounding liquid nitrogen (LN 2 ). An experimental system reproducing the fast transient heating of a tape electrode, synchronized with a high voltage impulse is described. Breakdown voltages measurements in both polarities are carried out versus synchronization delay, pressure (0.10 to 0.40 MPa), temperature (77 K and 65 K). Breakdown voltages show complex variations with these parameters. More insight is obtained from the recording of pre-breakdown phenomena (streamer). The size of vapor bubbles has a large and counter-intuitive influence on streamer initiation: the smaller bubbles, the lower inception voltage. Subcooling LN 2 (by decreasing temperature and/or increasing pressure) sometimes has a beneficial influence (quenching of negative streamer propagation), but deleterious effects can be as well observed in other circumstances (by favouring positive streamer initiation).
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1690-1697
Breakdown Phenomena in Liquid Nitrogen Under Synchronized Transient Boiling and Impulse Voltage
Resistive superconducting fault current limiters constitute a promising solution for high voltage networks. During the resistive current limitation, transient overvoltages and heat dissipation occur on superconducting tapes, inducing fast boiling of surrounding liquid nitrogen (LN 2 ). An experimental system reproducing the fast transient heating of a tape electrode, synchronized with a high voltage impulse is described. Breakdown voltages measurements in both polarities are carried out versus synchronization delay, pressure (0.10 to 0.40 MPa), temperature (77 K and 65 K). Breakdown voltages show complex variations with these parameters. More insight is obtained from the recording of pre-breakdown phenomena (streamer). The size of vapor bubbles has a large and counter-intuitive influence on streamer initiation: the smaller bubbles, the lower inception voltage. Subcooling LN 2 (by decreasing temperature and/or increasing pressure) sometimes has a beneficial influence (quenching of negative streamer propagation), but deleterious effects can be as well observed in other circumstances (by favouring positive streamer initiation).
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (6) , 2294-2302
Long-Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS
This paper investigates partial discharge (PD) behavior of protrusion defects in real size High Voltage Direct Current Gas Insulated Switchgear (HVDC GIS) for SF 6 and SF 6 alternative gases including Fluoronitrile – CO 2 mixture (10 %) and Fluoroketone – Dry Air mixture (6.6 %). The evolution of PD apparent charge and PD repetition rate for all investigated gases is presented and discussed. The measurement results indicate that PD behavior changes as a function of time. The PD apparent charge increases and the PD repetition rate decreases with the increase of voltage application time. This evolution can be related to the change in protrusion tip radius due to electrochemical etching: Radius of the protrusion’s tip being enlarged. Additionally, the Pulse Sequence Analysis (PSA) plots of the PDs caused by this defect are presented. It is observed that the PSA plots change over time. Therefore, for the development of a robust PD monitoring and defect recognition tool, as well as for the assessment of risks in the operation of HVDC GIS, it is crucial to take these changes into account.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (6) , 2294-2302
Long-Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS
This paper investigates partial discharge (PD) behavior of protrusion defects in real size High Voltage Direct Current Gas Insulated Switchgear (HVDC GIS) for SF 6 and SF 6 alternative gases including Fluoronitrile – CO 2 mixture (10 %) and Fluoroketone – Dry Air mixture (6.6 %). The evolution of PD apparent charge and PD repetition rate for all investigated gases is presented and discussed. The measurement results indicate that PD behavior changes as a function of time. The PD apparent charge increases and the PD repetition rate decreases with the increase of voltage application time. This evolution can be related to the change in protrusion tip radius due to electrochemical etching: Radius of the protrusion’s tip being enlarged. Additionally, the Pulse Sequence Analysis (PSA) plots of the PDs caused by this defect are presented. It is observed that the PSA plots change over time. Therefore, for the development of a robust PD monitoring and defect recognition tool, as well as for the assessment of risks in the operation of HVDC GIS, it is crucial to take these changes into account.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 607-610
Partial discharge measurement in DC GIS: comparison between conventional and UHF methods
The detection, identification and localization of defects are essential to ensure the service reliability of Gas Insulated Switchgear (GIS). Partial discharge (PD) measurement is well-known as one of the most effective technique for defect detection and identification in electrical insulation systems. PD measurement according to IEC standard 60270 is known as the conventional technique, in which PD is quantified in terms of apparent charge. Moreover, non-conventional technique, like UHF detection, can also be used for partial discharge measurement to enhance the signal/noise ratio in GIS. For AC electrical insulating systems both techniques are effectives, widely used and give the same signature of defect. Unfortunately, very little information is available for DC systems, especially regarding the comparison of the defect fingerprint between the two methods. The aim of this paper is to investigate the partial discharge signals recorded with both conventional and UHF methods in DC voltage. The results showed that the defect fingerprints are similar between the conventional measurement and the UHF measurement, regardless the UHF antenna position in the equipment.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 607-610
Partial discharge measurement in DC GIS: comparison between conventional and UHF methods
The detection, identification and localization of defects are essential to ensure the service reliability of Gas Insulated Switchgear (GIS). Partial discharge (PD) measurement is well-known as one of the most effective technique for defect detection and identification in electrical insulation systems. PD measurement according to IEC standard 60270 is known as the conventional technique, in which PD is quantified in terms of apparent charge. Moreover, non-conventional technique, like UHF detection, can also be used for partial discharge measurement to enhance the signal/noise ratio in GIS. For AC electrical insulating systems both techniques are effectives, widely used and give the same signature of defect. Unfortunately, very little information is available for DC systems, especially regarding the comparison of the defect fingerprint between the two methods. The aim of this paper is to investigate the partial discharge signals recorded with both conventional and UHF methods in DC voltage. The results showed that the defect fingerprints are similar between the conventional measurement and the UHF measurement, regardless the UHF antenna position in the equipment.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Study of Turn-to-Turn Electrical Breakdown for Superconducting Fault Current Limiter Applications
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Study of Turn-to-Turn Electrical Breakdown for Superconducting Fault Current Limiter Applications
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 613-616
Measurement of space charge distribution in alumina-filled epoxy resin for application in HVDC GIS
The present paper deals with space charge in alumina-filled epoxy resin for HVDC applications. The aim is to study the residual electric field in cylindrical insulators made of alumina-filled epoxy resin when they are subjected to high DC stress. This work concerns the behavior of the composite under 5, 11 and 28 kV applied, at a temperature of 25 °C. The electric field repartition in the bulk of cylindrical samples is determined. The space charge relaxation processes just after manufacturing and after application of each stress are assessed.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 613-616
Measurement of space charge distribution in alumina-filled epoxy resin for application in HVDC GIS
The present paper deals with space charge in alumina-filled epoxy resin for HVDC applications. The aim is to study the residual electric field in cylindrical insulators made of alumina-filled epoxy resin when they are subjected to high DC stress. This work concerns the behavior of the composite under 5, 11 and 28 kV applied, at a temperature of 25 °C. The electric field repartition in the bulk of cylindrical samples is determined. The space charge relaxation processes just after manufacturing and after application of each stress are assessed.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00849162,p. 82-85
Negative LI breakdown behavior of electrodes with thin dielectric coatings in dry air at high pressure
In gas insulated switchgear(GIS) SF6 gas is widely in use because it has good electrical insulation and arc interruption capabilities. Due to environmental constraints the desire to use alternative gases is continuously growing. This paper focuses on dry air as an alternative gas which unfortunately has a breakdown strength which is lower than the breakdown strength of SF6 at equal gas pressure. To improve the breakdown strength of dry air filled GIS, dielectric coatings can be applied to the electrodes. In this paper, the performance of GIS with thin coatings is evaluated through breakdown tests in a rod-plane electrode arrangement. Negative lightning impulse voltage is applied on the rod electrode and the gas pressure is kept constant at 0.9 MPa.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00849162,p. 82-85
Negative LI breakdown behavior of electrodes with thin dielectric coatings in dry air at high pressure
In gas insulated switchgear(GIS) SF6 gas is widely in use because it has good electrical insulation and arc interruption capabilities. Due to environmental constraints the desire to use alternative gases is continuously growing. This paper focuses on dry air as an alternative gas which unfortunately has a breakdown strength which is lower than the breakdown strength of SF6 at equal gas pressure. To improve the breakdown strength of dry air filled GIS, dielectric coatings can be applied to the electrodes. In this paper, the performance of GIS with thin coatings is evaluated through breakdown tests in a rod-plane electrode arrangement. Negative lightning impulse voltage is applied on the rod electrode and the gas pressure is kept constant at 0.9 MPa.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 287-290
The influence of thin dielectric coatings on LI and AC breakdown strength in SF6 and dry air
Electric power consumption has increased over the years while the available space for substations has become smaller. Newly designed gas insulated switchgears (GIS) have to be smaller and have to operate at a higher system voltage. Furthermore, the urge to decrease the use of SF6 as an insulating gas in GIS is becoming larger because of the high production and handling costs and the high global warming potential. Unfortunately, the breakdown strength of alternative gases is usually lower than that of SF6. However, with the application of a coating on the electrodes in GIS the breakdown strength can be improved. In this paper, the performance of GIS with thin coatings is evaluated with breakdown tests. The test setup consists of a rodplane electrode arrangement with a coated rod electrode. The coatings vary in thickness between 40 micrometers and 2 millimeters. The breakdown tests are performed at either 50 Hz AC or lightning impulse voltage.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 287-290
The influence of thin dielectric coatings on LI and AC breakdown strength in SF6 and dry air
Electric power consumption has increased over the years while the available space for substations has become smaller. Newly designed gas insulated switchgears (GIS) have to be smaller and have to operate at a higher system voltage. Furthermore, the urge to decrease the use of SF6 as an insulating gas in GIS is becoming larger because of the high production and handling costs and the high global warming potential. Unfortunately, the breakdown strength of alternative gases is usually lower than that of SF6. However, with the application of a coating on the electrodes in GIS the breakdown strength can be improved. In this paper, the performance of GIS with thin coatings is evaluated with breakdown tests. The test setup consists of a rodplane electrode arrangement with a coated rod electrode. The coatings vary in thickness between 40 micrometers and 2 millimeters. The breakdown tests are performed at either 50 Hz AC or lightning impulse voltage.