Yubing Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yubing Shi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Hongyi Yang
Institute of Integrative Medicine, Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
3 shared publicationsJing Dong
Department of Interventional Therapy, the Second Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
2 shared publications- Patricia V. Lawford
Department of Infection, Immunity and Cardiovascular Disease, Medical School , Beech Hill Road, Sheffield, S102TN , UK
2 shared publications Chen Wei
1 shared publicationChristine Roffe
1 shared publication- D. Rodney Hose
A Medical Physics Unit, Department of Cardiovascular Science, Faculty of Medicine, Dentistry and Health , University of Sheffield , Sheffield , UK
1 shared publication
Latest Publications
- Open Access
- 31 December 2024
- Published by Nepal Journals Online (JOL) in Journal of Gandaki Medical College-Nepal
- Vol. 17 (2) , 187-95
Review of hemodynamics in direct aspiration thrombectomy for the treatment of acute ischemic stroke
Introduction: Acute ischemic stroke (AIS) is a common and lethal cerebral vascular disease. Early thrombus removal is crucial to the patient treatment and recovery. Clinical studies suggested that Direct Aspiration Thrombectomy (DAT) is a promising minimally invasive treatment option for AIS patients. It is necessary to summarize the hemodynamic studies about the DAT for further improvement of the technology. Methods: This paper reviewed the current in vitro and computer modelling studies of the hemodynamic response in the DAT, commenting on the merits and the deficiencies in the related research works reported in the literature. Results: Review of literature reveals that majority of current studies were focused on the comparison of the responses produced by using various suction systems on catheters of different calibers. For future technical improvement to facilitate clinical treatment, we suggest that further research to concentrate on more in-depth hemodynamic analysis of the DAT procedure, including replacement of the constant suction pressure with pulsatile suction pressure, comparison of contact aspiration and non-contact aspiration, and optimization of catheter tip design. Conclusions: This review summarized the concurrent technical development about the hemodynamic studies of the DAT technique and suggested directions for future improvement, which is helpful for the improvement of the AIS treatment planning and design optimization of next generation of interventional catheters.
- 31 December 2024
- Published by Nepal Journals Online (JOL) in Journal of Gandaki Medical College-Nepal
- Vol. 17 (2) , 187-95
Open AccessReview of hemodynamics in direct aspiration thrombectomy for the treatment of acute ischemic stroke
Introduction: Acute ischemic stroke (AIS) is a common and lethal cerebral vascular disease. Early thrombus removal is crucial to the patient treatment and recovery. Clinical studies suggested that Direct Aspiration Thrombectomy (DAT) is a promising minimally invasive treatment option for AIS patients. It is necessary to summarize the hemodynamic studies about the DAT for further improvement of the technology. Methods: This paper reviewed the current in vitro and computer modelling studies of the hemodynamic response in the DAT, commenting on the merits and the deficiencies in the related research works reported in the literature. Results: Review of literature reveals that majority of current studies were focused on the comparison of the responses produced by using various suction systems on catheters of different calibers. For future technical improvement to facilitate clinical treatment, we suggest that further research to concentrate on more in-depth hemodynamic analysis of the DAT procedure, including replacement of the constant suction pressure with pulsatile suction pressure, comparison of contact aspiration and non-contact aspiration, and optimization of catheter tip design. Conclusions: This review summarized the concurrent technical development about the hemodynamic studies of the DAT technique and suggested directions for future improvement, which is helpful for the improvement of the AIS treatment planning and design optimization of next generation of interventional catheters.
- Open Access
- 14 March 2024
- Published by Elsevier in Medicine in Novel Technology and Devices
- Vol. 22
Recent development of aspiration pump in the aspiration thrombectomy system
- 14 March 2024
- Published by Elsevier in Medicine in Novel Technology and Devices
- Vol. 22
Open AccessRecent development of aspiration pump in the aspiration thrombectomy system
- Open Access
- 11 July 2022
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 36 (21)
Numerical simulation of binder curing on the penetration in sand bed
- 11 July 2022
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 36 (21)
Open AccessNumerical simulation of binder curing on the penetration in sand bed
- Open Access
- 25 May 2021
- Published by Springer Nature in Journal of Biological Physics
- Vol. 47 (2) , 171-190
Comparison of stenosis models for usage in the estimation of pressure gradient across aortic coarctation
Non-invasive estimation of the pressure gradient in cardiovascular stenosis has much clinical importance in assisting the diagnosis and treatment of stenotic diseases. In this research, a systematic comparison is conducted to investigate the accuracy of a group of stenosis models against the MRI- and catheter-measured patient data under the aortic coarctation condition. Eight analytical stenosis models, including six from the literature and two proposed in this study, are investigated to examine their prediction accuracy against the clinical data. The two improved models proposed in this study consider comprehensively the Poiseuille loss, the Bernoulli loss in its exact form, and the entrance effect, of the blood flow. Comparison of the results shows that one of the proposed models demonstrates a cycle-averaged mean prediction error of −0.15 ± 3.03 mmHg, a peak-to-peak prediction error of −1.8 ± 6.89 mmHg, which is the best among the models studied.
- 25 May 2021
- Published by Springer Nature in Journal of Biological Physics
- Vol. 47 (2) , 171-190
Open AccessComparison of stenosis models for usage in the estimation of pressure gradient across aortic coarctation
Non-invasive estimation of the pressure gradient in cardiovascular stenosis has much clinical importance in assisting the diagnosis and treatment of stenotic diseases. In this research, a systematic comparison is conducted to investigate the accuracy of a group of stenosis models against the MRI- and catheter-measured patient data under the aortic coarctation condition. Eight analytical stenosis models, including six from the literature and two proposed in this study, are investigated to examine their prediction accuracy against the clinical data. The two improved models proposed in this study consider comprehensively the Poiseuille loss, the Bernoulli loss in its exact form, and the entrance effect, of the blood flow. Comparison of the results shows that one of the proposed models demonstrates a cycle-averaged mean prediction error of −0.15 ± 3.03 mmHg, a peak-to-peak prediction error of −1.8 ± 6.89 mmHg, which is the best among the models studied.
- 19 May 2019
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 43 (4) , 223-234
Mock circulatory test rigs for the in vitro testing of artificial cardiovascular organs
In vitro study plays an important role in the experimental study of cardiovascular dynamics. An essential hardware facility that mimics the blood flow changes and provides the required test conditions, a mock circulatory test rig (MCTR), is imperative for the execution of in vitro study. This paper examines the current MCTRs in use for the testing of artificial cardiovascular organs. Various aspects of the MCTRs are surveyed, including the necessity of in vitro study, the building of MCTRs, relevant standards, general system structure (e.g., the motion and driving, fluid, measurement subsystems), classification, motion driving mechanism of MCTRs, and the considerations for the modelling of the physiological impedance of MCTRs. Examples of the steady and pulsatile flow types of the MCTRs are introduced. Recent developments in MCTRs are inspected and possible future design improvements suggested. This study will help researchers in the design, construction, analysis, and selection of MCTRs for cardiovascular research.
- 19 May 2019
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 43 (4) , 223-234
Mock circulatory test rigs for the in vitro testing of artificial cardiovascular organs
In vitro study plays an important role in the experimental study of cardiovascular dynamics. An essential hardware facility that mimics the blood flow changes and provides the required test conditions, a mock circulatory test rig (MCTR), is imperative for the execution of in vitro study. This paper examines the current MCTRs in use for the testing of artificial cardiovascular organs. Various aspects of the MCTRs are surveyed, including the necessity of in vitro study, the building of MCTRs, relevant standards, general system structure (e.g., the motion and driving, fluid, measurement subsystems), classification, motion driving mechanism of MCTRs, and the considerations for the modelling of the physiological impedance of MCTRs. Examples of the steady and pulsatile flow types of the MCTRs are introduced. Recent developments in MCTRs are inspected and possible future design improvements suggested. This study will help researchers in the design, construction, analysis, and selection of MCTRs for cardiovascular research.
- 3 October 2018
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (7) , 525-531
Construction of lumped-parameter cardiovascular models using the CellML language
Lumped-parameter models are widely used by cardiovascular researchers in the analysis of the circulatory dynamics. However, portability and model exchange have always been a problem, with different researchers implement the model differently. To improve the situation, in this study, a group of lumped-parameter cardiovascular system models with different levels of complexity have been implemented using the CellML mark-up language. The models have been curated and made publicly available in the CellML model repository, and the purpose of this paper is to provide further technical details to support the usage of these models by the research community. The developed models are validated and tested under the OpenCell environment as part of the curation process. Simulation results agree well with typical published data on cardiovascular system response.
- 3 October 2018
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (7) , 525-531
Construction of lumped-parameter cardiovascular models using the CellML language
Lumped-parameter models are widely used by cardiovascular researchers in the analysis of the circulatory dynamics. However, portability and model exchange have always been a problem, with different researchers implement the model differently. To improve the situation, in this study, a group of lumped-parameter cardiovascular system models with different levels of complexity have been implemented using the CellML mark-up language. The models have been curated and made publicly available in the CellML model repository, and the purpose of this paper is to provide further technical details to support the usage of these models by the research community. The developed models are validated and tested under the OpenCell environment as part of the curation process. Simulation results agree well with typical published data on cardiovascular system response.
- 18 August 2018
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (6) , 443-452
Structure and motion design of a mock circulatory test rig
Mock circulatory test rig (MCTR) is the essential and indispensable facility in the cardiovascular in vitro studies. The system configuration and the motion profile of the MCTR design directly influence the validity, precision, and accuracy of the experimental data collected. Previous studies gave the schematic but never describe the structure and motion design details of the MCTRs used, which makes comparison of the experimental data reported by different research groups plausible but not fully convincing. This article presents the detailed structure and motion design of a sophisticated MCTR system, and examines the important issues such as the determination of the ventricular motion waveform, modelling of the physiological impedance, etc., in the MCTR designing. The study demonstrates the overall design procedures from the system conception, cardiac model devising, motion planning, to the motor and accessories selection. This can be used as a reference to aid researchers in the design and construction of their own in-house MCTRs for cardiovascular studies.
- 18 August 2018
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 42 (6) , 443-452
Structure and motion design of a mock circulatory test rig
Mock circulatory test rig (MCTR) is the essential and indispensable facility in the cardiovascular in vitro studies. The system configuration and the motion profile of the MCTR design directly influence the validity, precision, and accuracy of the experimental data collected. Previous studies gave the schematic but never describe the structure and motion design details of the MCTRs used, which makes comparison of the experimental data reported by different research groups plausible but not fully convincing. This article presents the detailed structure and motion design of a sophisticated MCTR system, and examines the important issues such as the determination of the ventricular motion waveform, modelling of the physiological impedance, etc., in the MCTR designing. The study demonstrates the overall design procedures from the system conception, cardiac model devising, motion planning, to the motor and accessories selection. This can be used as a reference to aid researchers in the design and construction of their own in-house MCTRs for cardiovascular studies.
- 1 February 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 93, 127-138
Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps
- 1 February 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 93, 127-138
Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps
- Open Access
- 1 June 2017
- Published by Elsevier in Physics in Medicine
- Vol. 3, 1-8
Suction force-suction distance relation during aspiration thrombectomy for ischemic stroke: A computational fluid dynamics study
- 1 June 2017
- Published by Elsevier in Physics in Medicine
- Vol. 3, 1-8
Open AccessSuction force-suction distance relation during aspiration thrombectomy for ischemic stroke: A computational fluid dynamics study