Xing Yue (Larry) Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xing Yue (Larry) Peng has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Linghan Peng
Biology Department, Xiamen University, Xiamen 361102, Fujian, China
3 shared publicationsYaxin Guo
Biology Department, Xiamen University, Xiamen 361102, Fujian, China
3 shared publicationsBocun Dong
Affiliation Biology Department, Xiamen University, Xiamen, Fujian, China
1 shared publicationDong-Hui Li
Cancer Centre of Medical collage, Xiamen University, Xiamen, Fujian, China
1 shared publication- Fei Liu
Okta Inc., San Francisco, CA, USA
1 shared publication - Hongwei Zhang
College of Materials Science and Engineering, Wuhan Textile University, WuHan, PR China
1 shared publication
Latest Publications
- Open Access
- 30 August 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (17) , 13419
A Microfluidic Experimental Method for Studying Cell-to-Cell Exosome Delivery–Taking Stem Cell–Tumor Cell Interaction as a Case
Cell-to-cell communication must occur through molecular transport in the intercellular fluid space. Nanoparticles, such as exosomes, diffuse or move more slowly in fluids than small molecules. To find a microfluidic technology for real-time exosome experiments on intercellular communication between living cells, we use the microfluidic culture dish’s quaternary ultra-slow microcirculation flow field to accumulate nanoparticles in a specific area. Taking stem cell–tumor cell interaction as an example, the ultra-slow microcirculatory flow field controls stem cell exosomes to interfere with tumor cells remotely. Under static coculture conditions (without microfluidics), the tumor cells near stem cells (<200 µm) show quick breaking through from its Matrigel drop to meet stem cells, but this ‘breaking through’ quickly disappears with increasing distance. In programmed ultra-slow microcirculation, stem cells induce tumor cells 5000 μm far at the site of exosome deposition (according to nanoparticle simulations). After 14 days of programmed coculture, the glomeration and migration of tumor cells were observed in the exosome deposition area. This example shows that the ultra-slow microcirculation of the microfluidic culture dish has good prospects in quantitative experiments to study exosome communication between living cells and drug development of cancer metastasis.
- 30 August 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (17) , 13419
Open AccessA Microfluidic Experimental Method for Studying Cell-to-Cell Exosome Delivery–Taking Stem Cell–Tumor Cell Interaction as a Case
Cell-to-cell communication must occur through molecular transport in the intercellular fluid space. Nanoparticles, such as exosomes, diffuse or move more slowly in fluids than small molecules. To find a microfluidic technology for real-time exosome experiments on intercellular communication between living cells, we use the microfluidic culture dish’s quaternary ultra-slow microcirculation flow field to accumulate nanoparticles in a specific area. Taking stem cell–tumor cell interaction as an example, the ultra-slow microcirculatory flow field controls stem cell exosomes to interfere with tumor cells remotely. Under static coculture conditions (without microfluidics), the tumor cells near stem cells (<200 µm) show quick breaking through from its Matrigel drop to meet stem cells, but this ‘breaking through’ quickly disappears with increasing distance. In programmed ultra-slow microcirculation, stem cells induce tumor cells 5000 μm far at the site of exosome deposition (according to nanoparticle simulations). After 14 days of programmed coculture, the glomeration and migration of tumor cells were observed in the exosome deposition area. This example shows that the ultra-slow microcirculation of the microfluidic culture dish has good prospects in quantitative experiments to study exosome communication between living cells and drug development of cancer metastasis.
- Open Access
- 22 November 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (11) , e0277811
Cancer metastasis is related to normal tissue stemness
The occurrence of cancer metastasis may be related to stem cells in normal tissues. We searched for patient IDs with both normal tissue stem cell values and TCGA (The Cancer Genome Atlas) clinical data for pairing and obtained 639 sets of data (stemness index of normal tissue, stemness index of tumor tissue, cancer stage, distant metastasis, tumor size) and invasion, and lymph node involvement). However, clinical data on cancer metastasis are of only four stages (e.g., Stage I, II, III, and IV), which cannot show subtle changes continuously. We need to find an effective data mining method to transform this four-valued clinical description into a numerical curve. We data-mine this data through numericalization, sorting, and noise reduction filtering. The results showed that: as the normal tissue stemness value (NS) increased, the tumor tissue stemness value (TS) increased proportionally (1.26 times NS). When NS >0.5, the rate of change in TS decelerated (0.43 times NS), and tumor metastasis began to occur. Clinical indicators, such as cancer stage, distant metastasis, tumor size and invasion, and lymph node involvement, showed that tumor metastasis became more and more severe with the increase of NS. This study suggests that tumor metastasis is triggered when the NS in the patient’s body is more significant than 0.5.
- 22 November 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (11) , e0277811
Open AccessCancer metastasis is related to normal tissue stemness
The occurrence of cancer metastasis may be related to stem cells in normal tissues. We searched for patient IDs with both normal tissue stem cell values and TCGA (The Cancer Genome Atlas) clinical data for pairing and obtained 639 sets of data (stemness index of normal tissue, stemness index of tumor tissue, cancer stage, distant metastasis, tumor size) and invasion, and lymph node involvement). However, clinical data on cancer metastasis are of only four stages (e.g., Stage I, II, III, and IV), which cannot show subtle changes continuously. We need to find an effective data mining method to transform this four-valued clinical description into a numerical curve. We data-mine this data through numericalization, sorting, and noise reduction filtering. The results showed that: as the normal tissue stemness value (NS) increased, the tumor tissue stemness value (TS) increased proportionally (1.26 times NS). When NS >0.5, the rate of change in TS decelerated (0.43 times NS), and tumor metastasis began to occur. Clinical indicators, such as cancer stage, distant metastasis, tumor size and invasion, and lymph node involvement, showed that tumor metastasis became more and more severe with the increase of NS. This study suggests that tumor metastasis is triggered when the NS in the patient’s body is more significant than 0.5.
- Open Access
- 7 May 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (6) , 2100045
Design Artificial Stem Cell Nests for Stem Cell Niche in a Microfluidic Petri Dish Programmed by a Cell Phone
This article describes a technology to transform a petri dish into a microfluidic chip with a stem cell nest for stem cell niche engineering. A permanent magnet sphere is put in a 30 mm petri dish as an oscillator pump (O‐pump). An earphone‐sized actuator outside the petri dish receives the programmed audio signal from an MP3 player or a mobile phone to drive the in‐dish O‐pump for a microflow. There are guiding walls to form a wake area for the cell nest at the dish's center. The cell nest uses the wake to create a stable, ultraslow internal microcirculation flow. The retention half‐life of nanoparticles in the cell nest is 1419.8 ± 1.3 s. By setting the microfluidic program and supplementing five drops of the culture medium outside the cell nest every 2 d, the growth rate of embryonic stem cells in the cell nest during the 8 d automatic culture appears significantly optimized. The single clone area of embryonic stem cells increases from (3.57 ± 0.52) × 105 to (11.67 ± 1.33) × 105 µm2 after 2 d of the automatic culture and advances to (53.34 ± 8.37) × 105 µm2 after 4 d.
- 7 May 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (6) , 2100045
Open AccessDesign Artificial Stem Cell Nests for Stem Cell Niche in a Microfluidic Petri Dish Programmed by a Cell Phone
This article describes a technology to transform a petri dish into a microfluidic chip with a stem cell nest for stem cell niche engineering. A permanent magnet sphere is put in a 30 mm petri dish as an oscillator pump (O‐pump). An earphone‐sized actuator outside the petri dish receives the programmed audio signal from an MP3 player or a mobile phone to drive the in‐dish O‐pump for a microflow. There are guiding walls to form a wake area for the cell nest at the dish's center. The cell nest uses the wake to create a stable, ultraslow internal microcirculation flow. The retention half‐life of nanoparticles in the cell nest is 1419.8 ± 1.3 s. By setting the microfluidic program and supplementing five drops of the culture medium outside the cell nest every 2 d, the growth rate of embryonic stem cells in the cell nest during the 8 d automatic culture appears significantly optimized. The single clone area of embryonic stem cells increases from (3.57 ± 0.52) × 105 to (11.67 ± 1.33) × 105 µm2 after 2 d of the automatic culture and advances to (53.34 ± 8.37) × 105 µm2 after 4 d.
- Open Access
- 2 May 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (6) , 2100150
A Highly Programmable Magnetic Micropump
A cheap, small, convenient, reliable, and durable lab‐on‐a‐chip is needed for various scenarios in practical applications. The authors hope to use the chip only after plugging in a mobile phone. An ideal micropump design is obtained by simplifying the micropump theory, reducing the micropump to 1 mm (oscillator pump, O‐pump), the external device (actuator) to 5 mm, and the power to 10 mW. This system costs ≈$10 and can work in harsh fluid environments (such as animal cell culture) for an extended period (a few months of testing). An MP3 player drives two O‐pumps by a programmable playlist. The O‐pump is a permanent magnet positive sphere in an open fluid space, which is not easy to block and rolls freely without wear. Only controlled by the magnetic field, the O‐pump avoids interference from the current, electric field, and chemical activity. The fluid is driven by a vibrating motion, in open or sealed channels, with no unique materials and no other equipment. The debris, bubbles, and fibers in the blood viscosity fluid do not affect the pump's function. The system can be applied in different scenarios, such as the automatic cultivation of stem cells or point‐of‐care devices.
- 2 May 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (6) , 2100150
Open AccessA Highly Programmable Magnetic Micropump
A cheap, small, convenient, reliable, and durable lab‐on‐a‐chip is needed for various scenarios in practical applications. The authors hope to use the chip only after plugging in a mobile phone. An ideal micropump design is obtained by simplifying the micropump theory, reducing the micropump to 1 mm (oscillator pump, O‐pump), the external device (actuator) to 5 mm, and the power to 10 mW. This system costs ≈$10 and can work in harsh fluid environments (such as animal cell culture) for an extended period (a few months of testing). An MP3 player drives two O‐pumps by a programmable playlist. The O‐pump is a permanent magnet positive sphere in an open fluid space, which is not easy to block and rolls freely without wear. Only controlled by the magnetic field, the O‐pump avoids interference from the current, electric field, and chemical activity. The fluid is driven by a vibrating motion, in open or sealed channels, with no unique materials and no other equipment. The debris, bubbles, and fibers in the blood viscosity fluid do not affect the pump's function. The system can be applied in different scenarios, such as the automatic cultivation of stem cells or point‐of‐care devices.
- Open Access
- 9 April 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (4) , 63
A One-Square-Millimeter Compact Hollow Structure for Microfluidic Pumping on an All-Glass Chip
A micro surface tension pump is a new type of low-cost, built-in, all-glass, microfluidic pump on a glass microchip fabricated by one-step glass etching. However, geometric minimization and optimization for practical use are challenging. Here, we report a one-square-millimeter, built-in, all-glass pump controlled by two-way digital gas pressure. The pump consists simply of two joint chambers and a piston between two gas control channels. It does not require pre-perfusion for initialization, and can immediately begin to run when a liquid enters its inlet channel. It is also more reliable than conventional micro pumps for practical use due to its ability to restart after the formation of a blocking bubble, which can serve as a valuable troubleshooting procedure. Its volumetric pump output was 0.5–0.7 nL·s−1 under a pump head pressure of 300 Pa.
- 9 April 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (4) , 63
Open AccessA One-Square-Millimeter Compact Hollow Structure for Microfluidic Pumping on an All-Glass Chip
A micro surface tension pump is a new type of low-cost, built-in, all-glass, microfluidic pump on a glass microchip fabricated by one-step glass etching. However, geometric minimization and optimization for practical use are challenging. Here, we report a one-square-millimeter, built-in, all-glass pump controlled by two-way digital gas pressure. The pump consists simply of two joint chambers and a piston between two gas control channels. It does not require pre-perfusion for initialization, and can immediately begin to run when a liquid enters its inlet channel. It is also more reliable than conventional micro pumps for practical use due to its ability to restart after the formation of a blocking bubble, which can serve as a valuable troubleshooting procedure. Its volumetric pump output was 0.5–0.7 nL·s−1 under a pump head pressure of 300 Pa.
- Open Access
- 26 November 2015
- Published by Frontiers Media SA in Frontiers in Marine Science
- Vol. 2
Characterizing the Interactions Among a Dinoflagellate, Flagellate and Bacteria in the Phycosphere of Alexandrium tamarense (Dinophyta)
A small flagellate alga was isolated from the phycosphere of a toxic red tide dinoflagellate Alexandrium tamarense. Phylogenetic analysis and ultrastructural observations demonstrated that the samll flagellate alga is a species belong to Ochrophyte Ochromonas sp. The process of ingesting bacteria by Ochromonas sp. was recorded by a time lapse capture under a light microscope. Through the use of different assemblages in the co-culture experiment, the species interactions in this phycosphere microenvironment were analyzed. We demonstrated that the growth of Ochromonas sp. was supported by bacteria. Three strains of bacteria ingested by Ochromonas sp. were isolated and identified to belong to α-, δ- and γ-Proteobacteria. The growth of A. tamarense was suppressed when co-cultured with bacteria. In contrast, Ochromonas sp. triggered the growth of A. tamarense by inhibiting the growth of algicidal bacteria. This result firstly demonstrated a positive effect of a flagellate on a dinoflagellate in the phycosphere of A. tamarense. Combined with other negative effects between dinoflagellates and bacteria or bacteria and flagellates, this study showed a series of clear interactions among dinoflagellate, bacterium, and flagellate in the dinoflagellate microenvironment.
- 26 November 2015
- Published by Frontiers Media SA in Frontiers in Marine Science
- Vol. 2
Open AccessCharacterizing the Interactions Among a Dinoflagellate, Flagellate and Bacteria in the Phycosphere of Alexandrium tamarense (Dinophyta)
A small flagellate alga was isolated from the phycosphere of a toxic red tide dinoflagellate Alexandrium tamarense. Phylogenetic analysis and ultrastructural observations demonstrated that the samll flagellate alga is a species belong to Ochrophyte Ochromonas sp. The process of ingesting bacteria by Ochromonas sp. was recorded by a time lapse capture under a light microscope. Through the use of different assemblages in the co-culture experiment, the species interactions in this phycosphere microenvironment were analyzed. We demonstrated that the growth of Ochromonas sp. was supported by bacteria. Three strains of bacteria ingested by Ochromonas sp. were isolated and identified to belong to α-, δ- and γ-Proteobacteria. The growth of A. tamarense was suppressed when co-cultured with bacteria. In contrast, Ochromonas sp. triggered the growth of A. tamarense by inhibiting the growth of algicidal bacteria. This result firstly demonstrated a positive effect of a flagellate on a dinoflagellate in the phycosphere of A. tamarense. Combined with other negative effects between dinoflagellates and bacteria or bacteria and flagellates, this study showed a series of clear interactions among dinoflagellate, bacterium, and flagellate in the dinoflagellate microenvironment.
- Open Access
- 12 October 2015
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 26, 02003
Gas Phase Fabrication of Pd-Ni Nanoparticle Arrays for Hydrogen Sensor Applications
- 12 October 2015
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 26, 02003
Open AccessGas Phase Fabrication of Pd-Ni Nanoparticle Arrays for Hydrogen Sensor Applications
- 19 October 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (1) , 132-138
A micro surface tension pump (MISPU) in a glass microchip
A non-membrane micro surface tension pump (MISPU) was fabricated on a glass microchip by one-step glass etching. It needs no material other than glass and is driven by digital gas pressure. The MISPU can be seen working like a piston pump inside the glass microchip under a microscope. The design of the valves (MISVA) and pistons (MISTON) was based on the surface tension theory of the micro surface tension alveolus (MISTA). The digital gas pressure controls the moving gas–liquid interface to open or close the input and output MISVAs to refill or drive the MISTON for pumping a liquid. Without any moving parts, a MISPU is a kind of long-lasting micro pump for micro chips that does not lose its water pumping efficiency over a 20-day period. The volumetric pump output varied from 0 to 10 nl s−1 when the pump cycle time decreased from 5 min to 15 s. The pump head pressure was 1 kPa.
- 19 October 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (1) , 132-138
A micro surface tension pump (MISPU) in a glass microchip
A non-membrane micro surface tension pump (MISPU) was fabricated on a glass microchip by one-step glass etching. It needs no material other than glass and is driven by digital gas pressure. The MISPU can be seen working like a piston pump inside the glass microchip under a microscope. The design of the valves (MISVA) and pistons (MISTON) was based on the surface tension theory of the micro surface tension alveolus (MISTA). The digital gas pressure controls the moving gas–liquid interface to open or close the input and output MISVAs to refill or drive the MISTON for pumping a liquid. Without any moving parts, a MISPU is a kind of long-lasting micro pump for micro chips that does not lose its water pumping efficiency over a 20-day period. The volumetric pump output varied from 0 to 10 nl s−1 when the pump cycle time decreased from 5 min to 15 s. The pump head pressure was 1 kPa.
- 16 September 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (22) , 3251-3254
A micro surface tension alveolus (MISTA) in a glass microchip
We have designed a non-membrane micro surface tension alveolus (MISTA) in a glass microchip for direct gas exchange and micro gradient control. Hemoglobin (Hb) in the liquid phase indicates the rapid gas gradient changes of O2 and CO2 shifted by the difference in pressure between the liquid and the gas.
- 16 September 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (22) , 3251-3254
A micro surface tension alveolus (MISTA) in a glass microchip
We have designed a non-membrane micro surface tension alveolus (MISTA) in a glass microchip for direct gas exchange and micro gradient control. Hemoglobin (Hb) in the liquid phase indicates the rapid gas gradient changes of O2 and CO2 shifted by the difference in pressure between the liquid and the gas.