Pedro Couceiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedro Couceiro has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Julian Alonso
Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edific Cn, 08193 Bellaterra, Barcelona, Spain
5 shared publications M. Berenguel-Alonso
2 shared publicationsA. Salinas-Castillo
1 shared publication- Antonio Calvo-Lopez
Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193 Barcelona, Spain
1 shared publication - Belén Fernández
Institute of Parasitology and Biomedicine “López-Neyra”, Consejo Superior de Investigaciones Científicas (CSIC), Granada, Spain
1 shared publication - Francisco Valdés Perezgasga
Instituto Tecnológico de la Laguna, México, Cuauhtémoc y Revolución s/n, Torreón Coahuila 27000, Mexico
1 shared publication
Latest Publications
- Open Access
- 28 June 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (7) , 1023
Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production.
- 28 June 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (7) , 1023
Open AccessFluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production.
- 1 October 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 296, 126613
An LTCC monolithic microreactor for the synthesis of carbon dots with photoluminescence imaging of the reaction progress
- 1 October 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 296, 126613
An LTCC monolithic microreactor for the synthesis of carbon dots with photoluminescence imaging of the reaction progress
- Open Access
Microanalyser Prototype for On-Line Monitoring of Copper(II) Ion in Mining Industrial Processes
A microanalyzer prototype for copper(II) ion monitoring in mining industrial processes is presented. The microanalyzer is designed as an assembly of different modules, each module being responsible for a unit operation. In order to optimize the industrial processes, the microanalyzer can automate all sample management, signal processing, and mathematical calculations and wirelessly transfer data to a control room. The determination of copper(II) ion is done using a colorimetric reaction and the microanalyser performs autocalibration by in situ dilution of a stock solution, matching the higher analyte concentration of the working range defined for the sample to be determined, using a multicommutation approach. The performance of the microanalyzer for monitoring copper(II) ion in water effluents of mining facilities was optimized in the working range from 1 to 10 mg/L to match Mexican environmental law regulations, which allow a maximum concentration of 4 mg/L of copper(II) ion in these circumstances.
Open AccessMicroanalyser Prototype for On-Line Monitoring of Copper(II) Ion in Mining Industrial Processes
A microanalyzer prototype for copper(II) ion monitoring in mining industrial processes is presented. The microanalyzer is designed as an assembly of different modules, each module being responsible for a unit operation. In order to optimize the industrial processes, the microanalyzer can automate all sample management, signal processing, and mathematical calculations and wirelessly transfer data to a control room. The determination of copper(II) ion is done using a colorimetric reaction and the microanalyser performs autocalibration by in situ dilution of a stock solution, matching the higher analyte concentration of the working range defined for the sample to be determined, using a multicommutation approach. The performance of the microanalyzer for monitoring copper(II) ion in water effluents of mining facilities was optimized in the working range from 1 to 10 mg/L to match Mexican environmental law regulations, which allow a maximum concentration of 4 mg/L of copper(II) ion in these circumstances.
- 14 August 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (17) , 9147-9153
Microfabrication of Monolithic Microfluidic Platforms Using Low Temperature Co-Fired Ceramics Suitable for Fluorescence Imaging
In this work, the influence of laser ablation and lamination parameters in the fabrication of embedded microstructures using Low Temperature Co-Fired Ceramics, have been studied. First, the influence of laser ablation parameters in the dimensions of fabricated microchannels in Low Temperature Co-Fired Ceramics substrates was characterized and strategies for tailoring the microchannels aspect ratios are described. The influence of lamination conditions on the fabrication of monolithically embedded microstructures is presented. Thereafter, a ceramic microfluidic platform, was constructed using a multilayer approach. The ceramic microfluidic platforms incorporate three independent inlet channels and a microfluidic chamber with an monolithically integrated transparent optical windows. The construction procedure used ensures monolithic ceramic devices with homogeneous surface chemistry as well as homogeneous physical properties. Fluorescence dyes were used in order to characterize the hydrodynamic focusing as a function of flow rate ratio of the microfluidic chamber inlets. The results obtained open the possibility of studying chemical process, in static or flow conditions using fluorescence imaging, within the traditional fields of LTCC technology, such as high-temperature or organic solvents applications, while using a simple fabrication procedure suitable for low cost mass production.
- 14 August 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (17) , 9147-9153
Microfabrication of Monolithic Microfluidic Platforms Using Low Temperature Co-Fired Ceramics Suitable for Fluorescence Imaging
In this work, the influence of laser ablation and lamination parameters in the fabrication of embedded microstructures using Low Temperature Co-Fired Ceramics, have been studied. First, the influence of laser ablation parameters in the dimensions of fabricated microchannels in Low Temperature Co-Fired Ceramics substrates was characterized and strategies for tailoring the microchannels aspect ratios are described. The influence of lamination conditions on the fabrication of monolithically embedded microstructures is presented. Thereafter, a ceramic microfluidic platform, was constructed using a multilayer approach. The ceramic microfluidic platforms incorporate three independent inlet channels and a microfluidic chamber with an monolithically integrated transparent optical windows. The construction procedure used ensures monolithic ceramic devices with homogeneous surface chemistry as well as homogeneous physical properties. Fluorescence dyes were used in order to characterize the hydrodynamic focusing as a function of flow rate ratio of the microfluidic chamber inlets. The results obtained open the possibility of studying chemical process, in static or flow conditions using fluorescence imaging, within the traditional fields of LTCC technology, such as high-temperature or organic solvents applications, while using a simple fabrication procedure suitable for low cost mass production.
- 1 June 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 245, 477-483
Automatic microfluidic system to perform multi-step magneto-biochemical assays
- 1 June 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 245, 477-483
Automatic microfluidic system to perform multi-step magneto-biochemical assays
- 13 August 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 18 (4) , 649-656
All-ceramic analytical microsystems with monolithically integrated optical detection microflow cells
- 13 August 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 18 (4) , 649-656
All-ceramic analytical microsystems with monolithically integrated optical detection microflow cells