DBDieter Berwouts

Dieter Berwouts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dieter Berwouts has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Indira Madani

    Department of Radiotherapy and Experimental Cancer Research, Ghent University Hospital, Ghent, Belgium

    3 shared publications
  • Wilfried De Neve

    Department of Radiotherapy and Experimental Cancer Research, Ghent University Hospital, Ghent, Belgium

    3 shared publications
  • Ingeborg Goethals

    Department of Nuclear Medicine, Ghent University Hospital, Ghent, Belgium

    2 shared publications
  • Tom Vercauteren

    Department of Radiotherapy and Experimental Cancer Research, Ghent University Hospital, Ghent, Belgium

    2 shared publications
  • Werner De Gersem

    Department of Radiation Oncology, Ghent University Hospital, C. Heymanslaan 10, 9000, Ghent, Belgium

    2 shared publications
  • Ana Maria Luiza Olteanu

    Department of Radiation Oncology, Ghent University Hospital, C. Heymanslaan 10, 9000, Ghent, Belgium

    1 shared publication

Latest Publications

  • A feasibility study on adaptive 18F-FDG-PET-guided radiotherapy for recurrent and second primary head and neck cancer in the previously irradiated territory

    by Julie Schatteman, Dirk Van Gestel, Dieter Berwouts, Werner De Gersem, Geert De Kerf, Wilfried De Neve, Bie De Ost, Ana Maria Luiza Olteanu, Sylvie Rottey, Tom Vercauteren, et al.

    Purpose To evaluate feasibility, disease control, survival, and toxicity after adaptive 18F-fluorodeoxyglucose (FDG) positron emisson tomography (PET) guided radiotherapy in patients with recurrent and second primary head and neck squamous cell carcinoma. Methods A prospective trial investigated the feasibility of adaptive intensity modulated radiotherapy (IMRT) ± concomitant cetuximab in 10 patients. The primary endpoint was achieving a 2-year survival free of grade >3 toxicity in ≥30% of patients. Three treatment plans based on 3 PET/CT scans were consecutively delivered in 6 weeks. The range of dose painting was 66.0–85.0 Gy in the dose-painted tumoral volumes in 30 fractions. Results Two-year locoregional and distant control rates were 38 and 76%, respectively. Overall and disease-free survival at 2 years was 20%. No grade 4 or 5 acute toxicity was observed in any of the patients, except for arterial mucosal hemorrhage in 1 patient. Three months after radiotherapy, grade 4 dysphagia and mucosal wound healing problems were observed in 1/7 and 1/6 of patients, respectively. Grade 5 toxicity (fatal bleeding) was seen in 2 patients, at 3.8 and 4.1 months of follow-up. Data on 2‑year toxicity could only be assessed in 1 of the 2 surviving patients, in whom grade 4 mucosal wound healing problems were observed; no other grade >3 toxicity was observed. In this respect, a 30% 2‑year survival free of grade >3 toxicity will not be achieved. Conclusions Adaptive PET-guided reirradiation is feasible. However, due to slow accrual and treatment results that seemed inconsistent with achieving the primary endpoint, the trial was stopped early.


  • Long‐term outcome of 18F‐fluorodeoxyglucose‐positron emission tomography‐guided dose painting for head and neck cancer: Matched case‐control study

    by Dieter Berwouts, Indira Madani, Frédéric Duprez, AnaMaria Luiza Olteanu, Tom Vercauteren, Tom Boterberg, Philippe Deron, Katrien Bonte, Wouter Huvenne, Wilfried De Neve, et al.

    Background: The purpose of this study was to report the long‐term outcome of 18F‐fluorodeoxyglucose‐positron emission tomography (18F‐FDG‐PET)‐guided dose painting for head and neck cancer in comparison to conventional intensity‐modulated radiotherapy (IMRT) in a matched case‐control study.Methods: Seventy‐two patients with nonmetastatic head and neck cancer treated with dose painting were compared with 72 control patients matched on tumor site and T classification. Either 18F‐FDG‐PET‐guided dose painting by contour (DPBC) or voxel intensity‐based dose painting by number (DPBN) was performed; control patients underwent standard IMRT. A total median dose to the dose‐painted target was 70.2‐85.9 Gy/30‐32 fractions versus 69.1 Gy/32 fractions with conventional IMRT. In 31 patients, dose painting was adapted to per‐treatment changes in the tumor and organs‐at‐risk (OAR).Results: Median follow‐up in living dose‐painting and control patients was 87.7 months (range 56.1‐119.3) and 64.8 months (range 46.3‐83.4), respectively. Five‐year local control rates in the dose‐painting patients were 82.3% against 73.6% in the control (P = .36); in patients treated to normalized isoeffective doses >91 Gy (NID2Gy) local control reached 85.7% at 5 years against 73.6% in the control group (P =.39). There was no difference in regional (P = .82) and distant control (P = .78). Five‐year overall and disease‐specific survival rates were 36.3% versus 38.1% (P = .50) and 56.5% versus 51.7% (P = .72), respectively. A half of the dose‐painting patients developed acute grade ≥3 dysphagia (P = .004). Late grade 4 mucosal ulcers at the site of dose escalation in 9 of 72 patients was the most common severe toxicity with dose painting versus 3 of 72 patients with conventional IMRT (P = .11). Patients in the dose‐painting group had increased rates of acute and late dysphagia (P = .004 and P = .005).Conclusion: Dose‐painting strategies can be used to increase dose to specific tumor subvolumes. Five‐year local, regional, and distant control rates are comparable with patients treated with conventional IMRT. Volume and intensity of dose escalation should be further tailored, given the possible increase in severe acute and chronic toxicity. Adapting treatment and decreasing dose to the swallowing structures might contribute to lower toxicity rates when applied in smaller tumor volumes. Whether adaptive DPBN can significantly improve outcomes is currently being investigated in a novel clinical trial.


  • Variations in target volume definition and dose to normal tissue using anatomic versus biological imaging (18F‐FDG‐PET) in the treatment of bone metastases: results from a 3‐arm randomized phase II trial

    by Dieter Berwouts, Katrien De Wolf, Wilfried De Neve, Luiza Am Olteanu, Bieke Lambert, Bruno Speleers, Ingeborg Goethals, Indira Madani, Piet Ost

    To report the impact on target volume delineation and dose to normal tissue using anatomic versus biological imaging (18F-FDG-PET) for bone metastases. Patients with uncomplicated painful bone metastases were randomized (1:1:1) and blinded to receive either 8 Gy in a single fraction with conventionally planned radiotherapy (ConvRT-8 Gy) or 8 Gy in a single fraction with dose-painting-by-numbers (DPBN) dose range between 6 and 10 Gy) (DPBN-8 Gy) or 16 Gy in a single fraction with DPBN (dose range between 14 and 18 Gy) (DPBN-16 Gy). The primary endpoint was overall pain response at 1 month. Volumes of the gross tumour volume (GTV) – both biological (GTVPET) and anatomical (GTVCT) -, planning target volume (PTV), dose to the normal tissue and maximum standardized-uptake values (SUVMAX) were analysed (secondary endpoint). Sixty-three percent of the GTVCT volume did not show 18F-FDG-uptake. On average, 20% of the GTVPET volume was outside GTVCT. The volume of normal tissue receiving 4 Gy, 6 Gy and 8 Gy was at least 3×, 6× and 13× smaller in DPBN-8 Gy compared to ConvRT-8 Gy and DPBN-16 Gy (P < 0.05). Positron emitting tomography-information potentially changes the target volume for bone metastases. DPBN between 6 and 10 Gy significantly decreases dose to the normal tissue compared to conventional radiotherapy.


  • Open Access

    Intensity modulated arc therapy implementation in a three phase adaptive 18F-FDG-PET voxel intensity-based planning strategy for head-and-neck cancer

    by Dieter Berwouts, Luiza Ana Maria Olteanu, Bruno Speleers, Frédéric Duprez, Indira Madani, Tom Vercauteren, Wilfried De Neve, Werner De Gersem

    This study investigates the implementation of a new intensity modulated arc therapy (IMAT) class solution in comparison to a 6-static beam step-and-shoot intensity modulated radiotherapy (s-IMRT) for three-phase adaptive 18F-FDG-PET-voxel-based dose-painting-by-numbers (DPBN) for head-and-neck cancer. We developed 18F-FDG-PET-voxel intensity-based IMAT employing multiple arcs and compared it to clinically used s-IMRT DPBN. Three IMAT plans using 18F-FDG-PET/CT acquired before treatment (phase I), after 8 fractions (phase II) and CT acquired after 18 fractions (phase III) were generated for each of 10 patients treated with 3 s-IMRT plans based on the same image sets. Based on deformable image registration (ABAS, version 0.41, Elekta CMS Software, Maryland Heights, MO), doses of the 3 plans were summed on the pretreatment CT using validated in-house developed software. Dosimetric indices in targets and organs-at-risk (OARs), biologic conformity of treatment plans set at ≤5 %, treatment quality and efficiency were compared between IMAT and s-IMRT for the whole group and for individual patients. Doses to most organs-at-risk (OARs) were significantly better in IMAT plans, while target levels were similar for both types of plans. On average, IMAT ipsilateral and contralateral parotid mean doses were 14.0 % (p = 0.001) and 12.7 % (p < 0.001) lower, respectively. Pharyngeal constrictors D50% levels were similar or reduced with up to 54.9 % for IMAT compared to s-IMRT for individual patient cases. IMAT significantly improved biologic conformity by 2.1 % for treatment phases I and II. 3D phantom measurements reported an agreement of ≥95 % for 3 % and 3 mm criteria for both treatment modalities. IMAT delivery time was significantly shortened on average by 41.1 %. IMAT implementation significantly improved the biologic conformity as compared to s-IMRT in adaptive dose-escalated DPBN treatments. The better OAR sparing and faster delivery highly improved the treatment efficiency.


  • Comparative dosimetry of three-phase adaptive and non-adaptive dose-painting IMRT for head-and-neck cancer

    by Luiza A.M. Olteanu, Dieter Berwouts, Indira Madani, Werner De Gersem, Tom Vercauteren, Fréderic Duprez, Wilfried De Neve


  • Vertebral Collapse Caused by Bone Metastasis

    by Dieter Berwouts, Mark Remery, Thomas Van Den Berghe