AYArbai Yusuf

Arbai Yusuf

*This is an algorithmically generated author record based on publicly available information.

Arbai Yusuf has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Circuit and Signal Processing for Capacitance Measurement of Breast Tissue

    by Arba'I Yusuf, S. Harry Sudibyo, Dodi Sudiana, Imamul Muttakin, MarlinR. Baidillah, Dilla Nelvo Dasril, Wahyu Widada, WarsitoP. Taruno

    In previous studies, electrical capacitance tomography has been developed and applied for imaging breast tissue to detect abnormalities within the breast caused by simple cysts, benign tumors and malignant cancers. For accurate screening and early detection of such abnormalities, high sensitive capacitance sensor is necessary. This study proposes a novel capacitance sensor circuit and signal conditioning and processing based on capacitance–voltage circuit for breast tissue measurement. The new sensor circuit design used a biopotential capacitance electrode, capable of measuring capacitance value with a resolution as low as 0.1 fF, a sensitivity of 1.6 V/pF, and linearity of 0.98. The experiment was conducted with a hemisphere 3D sensor 24 electrodes. The experiment strategy is as follow, first the system will be calibrated using network analyzer, secondly experiment using phantom 1, and the third experiment using phantom 2. In the design, we used a reference electrode made from fixed plate to measure capacitance inside the system, which will be used further for compensation against signal fluctuation caused by environmental condition such as humidity, temperature, pressure, etc. As a result, more stable system is achieved. Based on the experiment, the system can detect abnormalities of the human breast which are represented by two phantoms with different condition.

  • Open Access

    Design and Simulation of Quadrature Phase Detection in Electrical Capacitance Volume Tomography

    by Imamul Muttakin, Arbai Yusuf, Rohmadi Rohmadi, Wahyu Widada, Warsito P. Taruno

    Design and Simulation of Quadrature Phase Detection in Electrical Capacitance Volume Tomography


  • Analysis of single excitation signal for high speed ECVT data acquisition system

    by Arbai Yusuf, Imamul Muttakin, Wahyu Widada, Warsito P. Taruno

    This research investigates single excitation signal applied on ECVT (electrical capacitance volume tomography) data acquisition system (DAS). ECVT is one of tomography processes based on capacitance measurement. Excitation signals being used in the system are square and sine waves. Single wave excitation signal was injected into pair electrodes which would produce one capacitance measurement. This method lessen the time required to acquire data thus fasten the data acquisition speed. For 16 channels, 138 frame per second could be achieved. The proposed method does not decrease accuracy and sensitivity of capacitance measurement.


  • Single signal conditioning multi electrode for ECVT data acquisition system

    by Arbai Yusuf, Imamul Muttakin, Rohmadi Rohmadi, Amir Rudin, Wahyu Widada, Warsito P. Taruno

    Data acquisition system with single signal conditioning for multi-electrode on electrical capacitance volume tomography (ECVT) was described. ECVT is a method in 3D process imaging based on electrical capacitance. The ECVT hardware is employed to measure capacitance signal from 32 electrodes as sensory module. In this investigation, one signal conditioning was used for all electrodes hence hardware construction is simplified and power consumption is relatively low. In order to achieve that, switch configuration which could form analog multiplexer with small resistance and capacitance is required. Each electrode needs 4 analog switches, so that for 32 electrodes 128 analog switches are needed. The electrode is selectable according to desired function as excitation or detection. Experiment result has shown that this ECVT system is able to accomplish capacitance measurement with resolution 0.42 fF.


  • Development of two axis solar tracking using five photodiodes

    by Munnik Haryanti, Abdul Halim, Arbai Yusuf

    Utilization solar panels to generate electricity were increased all over the world including Indonesia. Generally, solar panels mounted on permanent structure which the angle of sunlight direction are fixed. This installation method will reduce the efficiency of electrical energy generated by solar panels due the angle of sun direction changes every time. There are needs equipment that used to steer solar panels toward the sun, namely solar tracking. In this study, we proposed development a prototype of two-axis solar tracking using five photodiodes. Overall, solar tracking system consists of two DC motors, five photodiodes, microcontroller system, and mechanical structure. DC motors are used to driving toward azimuth and elevation, photodiode act as sun-sensor functioned to measure the angle of sunlight direction, microcontroller system functioned to process data and give signal to DC motors. The five photodiodes usage are intended to reduce the cost purchasing of sun-sensor which relatively expensive on the market. Solar tracking prototype has been tested using artificial light with an intensity is closer to the sunlight. Experiment result has shown that this solar tracking is able work very well and can follow the sun movement.


  • Formation of solar cells based on Ba0.5Sr0.5TiO3 (BST) ferroelectric thick film

    by Irzaman, H. Syafutra, A. Arif, H. Alatas, M. N. Hilaluddin, A. Kurniawan, J. Iskandar, M. Dahrul, A. Ismangil, D. Yosman, et al.

    Growth of Ba 0.5 Sr 0.5 TiO 3 (BST) 1 M thick films are conducted with variation of annealing hold time of 8 hours, 15 hours, 22 hours, and 29 hours at a constant temperature of 850 °C on p-type Si (100) substrate using sol-gel method then followed by spin coating process at 3000 rpm for 30 seconds. The BST thick film electrical conductivity is obtained to be 10−5 to 10−4 S/cm indicate that the BST thick film is classified as semiconductor material. The semiconductor energy band gap value of BST thick film based on annealing hold time of 8 hours, 15 hours, 22 hours, and 29 hours are 2.58 eV, 3.15 eV, 3.2 eV and 2.62 eV, respectively. The I-V photovoltaic characterization shows that the BST thick film is potentially solar cell device, and in accordance to annealing hold time of 8 hours, 15 hours, 22 hours and 29 hours have respective solar cell energy conversion efficiencies of 0.343%, 0.399%, 0.469% and 0.374%, respectively. Optical spectroscopy shows that BST thick film solar cells with annealing hold time of 8 hours, 15 hours, and 22 hours absorb effectively light energy at wavelength of ≥ 700 nm. BST film samples with annealing hold time of 29 hours absorb effectively light energy at wavelength of ≤ 700 nm. The BST thick film refraction index is between 1.1 to 1.8 at light wavelength between ±370 to 870 nm.


  • Brain tumor detection using electrical capacitance volume tomography (ECVT)

    by Warsito P. Taruno, Marlin R. Baidillah, Rommy I. Sulaiman, Muhammad F. Ihsan, Arbai Yusuf, Wahyu Widada, Muhammad Aljohani

    In this study, for the first time, we have used the ECVT technique, developed earlier for real-time and volumetric imaging of brain activity, to detect the presence of brain tumor. The ECVT sensor system measures the capacitance of electrical signals of the brain on the cortex, and generates a volumetric map of the brain activity on the cortex and inside the brain through a tomography image reconstruction algorithm based on a Neural-Network Multi-criteria Optimization Image Reconstruction Technique (NN-MOIRT). The ECVT is able to detect brain tumors through an examination of the brain functional abnormalities, as the tumors block the propagation of neuro-signals and cause abnormalities in the brain activity image. The ECVT sensor design has been optimized for the detection of the brain tumors in different sensitivity regions of the brain. Case studies have been carried out to five volunteers suffering from different brain tumors including ependymoma, oligodendroglioma, cranio-pharyngioma, germinoma pineal, and cerebellopontine angle tumors. Comparisons with their respective CT and MRI results have also been performed. The study has shown a great feasibility of the 4D imaging technique as a complementary alternative for a high speed non-radiation technique for brain cancer detection and functional imaging.


  • Design of capacitance measurement circuit for data acquisition system ECVT

    by Arbai Yusuf, Wahyu Widada, Warsito P. Taruno

    In this research, we proposed a capacitance measurement circuit Electrical Capacitance Volume Tomography (ECVT) to perform three-dimensional image visualization. The ECVT system is consists of three main parts i.e. sensor, data acquisition system, and computer. Data acquisition system is composed of capacitance measurement circuit and microcontroller to measure an unknown capacitance inside the sensor, collect data and send it to the computer. Further, these data is used to reconstruct 3D image. The design of the circuit used a sine wave 14.6 V p-p and 2.5 MHz of frequency injected to the electrode pair to measure an unknown capacitance inside the sensor. An experiment is performed using simulated phantom using sensor having the form of a half-sphere with combined triangular and rectangular shapes. The system is able to measure a capacitance value as low as four femto-Farads with 0.34% margin error.


  • A novel sensor design for breast cancer scanner based on Electrical Capacitance Volume Tomography (ECVT)

    by Warsito P. Taruno, Marlin R. Baidillah, Rommy I. Sulaiman, Arbai Yusuf, Wahyu Widada, Habib Alzufri, Muhammad Aljohani

    In this study, we proposed a novel sensor for real time 3D imaging of cancerous mass within human breast using the capacitance measurement method, namely Electrical Capacitance Volume Tomography developed earlier. The sensor works based on the fact that cancerous mass has much higher relative permittivity as compared with normal breast tissue. The electrical capacitance volume tomography (ECVT) imaging technique is capable of generating volumetric image of permittivity distribution of the breast in real time. The 3D sensor constitutes a half-sphere of sensing region to capture the whole permittivity image of the breast. The sensor consists of 24 electrodes with combined triangular and rectangular shapes. Simulated phantoms as well as actual phantom of human breast constituting paraffin as normal human breast tissue and rubber as breast cancer tissue have been used to test the reliability of the sensor system to evaluate the performance of the ECVT technique for breast cancer imaging. The reconstructed images using simulated objects as well as actual measurement using the actual phantom have shown accurate permittivity distributions. The results obtained showed a great feasibility of the 4D tomography imaging as an alternative for a robust and high speed nonradiation technique for breast cancer screening.


  • Bench model design of the electrical power system for Iinusat-1 NanoSatellite

    by Arba'I Yusuf, Gunawan Setyo Prabowo

    Satellite consists of some subsystems. One of the most important subsystems is electrical power system (EPS). EPS is a part of satellite. It is has a main task i.e. generating, saving, and distributing the electrical power as long as the satellite mission be held. The power budget for Iinusat-1 nano-satellite is estimated 25 - 30 Watts. To support this requirement, GaAs triple junction solar panels with efficiency as 25.1% was chosen. It could be generate the electrical power up to 33.3 watt. Meanwhile, lithium-polymer batteries with 60-Watts capacity will save the solar energy in the electrical power. To distribute the electrical energy, the solid-state switches are used. All voltages, currents, and temperatures will be measured using analog and digital conversion (ADC). The data from adc are collected and organized into one packet data and then sent to the main computer (OBDH) of the satellite. OBDH will send it to the ground station via TTC. We use the Atxmega128A1 to control the solid state switch, collecting data from the sensor, and to control data communication with OBDH.