Eric M. Rohren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eric M. Rohren has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Geoffrey Michael Currie
School of Dentistry and Medical Sciences, Charles Sturt University, Wagga Wagga, NSW, Australia
6 shared publications - Hubert H. Chuang
Department of Nuclear Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
4 shared publications - Phil Ramis
Radiology Partners Research Institute, Nashville, TN
3 shared publications B. Dabaja
2 shared publicationsC.C. Pinnix
2 shared publicationsE.M. Osborne
2 shared publications
Latest Publications
- Open Access
- 4 December 2025
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 56 (2) , 313-328
The Nuclear Nephrology Artificial Intelligence Ecosystem
- 4 December 2025
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 56 (2) , 313-328
Open AccessThe Nuclear Nephrology Artificial Intelligence Ecosystem
- Open Access
- 7 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (12) , 4034
Variability in Inferior Vena Cava (IVC) Filter Retrieval Rates and Adherence to Guidelines: A Multi-Center Retrospective Analysis
Background/Objectives: Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE) in patients with contraindications to anticoagulation, among other indications. Despite clinical guidelines recommending timely retrieval, rates remain suboptimal, raising concerns about long-term complications. This study examines national hospital-level variation in IVC filter retrieval rates and adherence to timing recommendations. Methods: A retrospective analysis was conducted using data from 12,197 patients across 158 U.S. facilities between 1 January 2020, and 29 August 2024. Retrieval rates, time to retrieval, and associations with facility-specific factors such as procedural volume and academic affiliation were evaluated using descriptive statistics and correlation analyses. Results: Facility retrieval rates varied widely, ranging from 0.36% to 100%, with a mean of 23% (SD 24%). Only 43% (SD 12%) of filters were retrieved within 90 days, as recommended. A weak negative correlation was observed between retrieval rate and procedure volume (r = −0.24), as well as patient age (r = −0.17). Several high-volume facilities showed potential guideline non-adherence, placing many filters but retrieving few. No significant differences were found between academic and non-academic institutions in retrieval rate or timing. Conclusions: Substantial variability exists in IVC filter retrieval practices, and many facilities fall short of timely removal benchmarks. These findings highlight the need for targeted quality improvement initiatives to increase retrieval adherence, reduce filter-related complications, and improve patient outcomes.
- 7 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (12) , 4034
Open AccessVariability in Inferior Vena Cava (IVC) Filter Retrieval Rates and Adherence to Guidelines: A Multi-Center Retrospective Analysis
Background/Objectives: Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE) in patients with contraindications to anticoagulation, among other indications. Despite clinical guidelines recommending timely retrieval, rates remain suboptimal, raising concerns about long-term complications. This study examines national hospital-level variation in IVC filter retrieval rates and adherence to timing recommendations. Methods: A retrospective analysis was conducted using data from 12,197 patients across 158 U.S. facilities between 1 January 2020, and 29 August 2024. Retrieval rates, time to retrieval, and associations with facility-specific factors such as procedural volume and academic affiliation were evaluated using descriptive statistics and correlation analyses. Results: Facility retrieval rates varied widely, ranging from 0.36% to 100%, with a mean of 23% (SD 24%). Only 43% (SD 12%) of filters were retrieved within 90 days, as recommended. A weak negative correlation was observed between retrieval rate and procedure volume (r = −0.24), as well as patient age (r = −0.17). Several high-volume facilities showed potential guideline non-adherence, placing many filters but retrieving few. No significant differences were found between academic and non-academic institutions in retrieval rate or timing. Conclusions: Substantial variability exists in IVC filter retrieval practices, and many facilities fall short of timely removal benchmarks. These findings highlight the need for targeted quality improvement initiatives to increase retrieval adherence, reduce filter-related complications, and improve patient outcomes.
- Open Access
- 24 February 2025
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (5) , 841-855
Sharpening the Blade of Precision Theranostics
- 24 February 2025
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (5) , 841-855
Open AccessSharpening the Blade of Precision Theranostics
- Open Access
- 24 February 2025
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (5) , 829-840
Potential of Technetium and Rhenium Theranostics
- 24 February 2025
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (5) , 829-840
Open AccessPotential of Technetium and Rhenium Theranostics
- Open Access
- 21 October 2024
- Published by The Royal Society in Philosophical Transactions of the Royal Society B: Biological Sciences
- Vol. 379 (1915) , 20230083
Individualized functional magnetic resonance imaging neuromodulation enhances visuospatial perception: a proof-of-concept study
This proof-of-concept study uses individualized functional magnetic resonance imaging neuromodulation (iNM) to explore the mechanisms that enhance BOLD signals in visuospatial perception (VP) networks that are crucial for navigation. Healthy participants ( n = 8) performed a VP up- and down-direction discrimination task at full and subthreshold coherence through peripheral vision, and superimposed direction through visual imagery (VI) at central space under iNM and control conditions. iNM targets individualized anatomical and functional middle- and medial-superior temporal (MST) networks that control VP. We found that iNM engaged selective exteroceptive and interoceptive attention (SEIA) and motor planning (MP) networks. Specifically, iNM increased overall: (i) area under the curve of the BOLD magnitude: 100% in VP (but decreased for weak coherences), 21–47% in VI, 26–59% in MP and 48–76% in SEIA through encoding; and (ii) classification performance for each direction, coherence and network through decoding, predicting stimuli from brain maps. Our findings, derived from encoding and decoding models, suggest that mechanisms induced by iNM are causally linked in enhancing visuospatial networks and demonstrate iNM as a feasibility treatment for low-vision patients with cortical blindness or visuospatial impairments that precede cognitive decline. This article is part of the theme issue ‘Neurofeedback: new territories and neurocognitive mechanisms of endogenous neuromodulation’.
- 21 October 2024
- Published by The Royal Society in Philosophical Transactions of the Royal Society B: Biological Sciences
- Vol. 379 (1915) , 20230083
Open AccessIndividualized functional magnetic resonance imaging neuromodulation enhances visuospatial perception: a proof-of-concept study
This proof-of-concept study uses individualized functional magnetic resonance imaging neuromodulation (iNM) to explore the mechanisms that enhance BOLD signals in visuospatial perception (VP) networks that are crucial for navigation. Healthy participants ( n = 8) performed a VP up- and down-direction discrimination task at full and subthreshold coherence through peripheral vision, and superimposed direction through visual imagery (VI) at central space under iNM and control conditions. iNM targets individualized anatomical and functional middle- and medial-superior temporal (MST) networks that control VP. We found that iNM engaged selective exteroceptive and interoceptive attention (SEIA) and motor planning (MP) networks. Specifically, iNM increased overall: (i) area under the curve of the BOLD magnitude: 100% in VP (but decreased for weak coherences), 21–47% in VI, 26–59% in MP and 48–76% in SEIA through encoding; and (ii) classification performance for each direction, coherence and network through decoding, predicting stimuli from brain maps. Our findings, derived from encoding and decoding models, suggest that mechanisms induced by iNM are causally linked in enhancing visuospatial networks and demonstrate iNM as a feasibility treatment for low-vision patients with cortical blindness or visuospatial impairments that precede cognitive decline. This article is part of the theme issue ‘Neurofeedback: new territories and neurocognitive mechanisms of endogenous neuromodulation’.
- Open Access
- 26 August 2024
- Published by Heighten Science Publications Corporation in Journal of Clinical Medical and Experimental Images
- Vol. 8 (1) , 007-012
Establishment of a Best Practice Recommendation (BPR) for Abdominal Aortic Aneurysms in a Large Multi-State Radiology Practice: Adoption and Impact
Purpose of the study: To evaluate the performance of Best Practice Recommendation (BPR) compliance in reporting abdominal aortic aneurysm findings on imaging, comparing the results before and after its deployment. Methods: Best Practice Recommendations for AAA were deployed in 2020 at a large radiology practice site. Reports between January 2018 through October 2022 were reviewed, representing studies read prior to and subsequent to the implementation of the reporting standards. Cases of abdominal aortic aneurysms ≥ 2.6 cm were counted by year. Adherence to the BPR for each year was calculated as [total number of confirmed cases of ≥ 2.6 cm AAAs with compliant reports] * 100 / [the total number of confirmed ≥ 2.6 cm AAAs]. A secondary analysis was performed to determine whether there was a statistically significant difference in the proportion of BPR-compliant reports for AAA cases before (from 2018 to 2019) and after (from 2020 to 2022) BPR deployment using a chi-square test. Results: From January 2018 to December 2022, there were 8,693 reports referencing AAA. After excluding cases of suspected AAA (N = 2,131), confirmed AAAs with indeterminate sizes (N = 103), and confirmed AAAs with sizes < 2.6 cm (N = 85), the number of AAA cases ≥ 2.6 cm in size was 6,374. Concordance with the BPR standards for the remaining cases with sizes ≥ 2.6 cm were 1.6% and 4.1% in 2018 and 2019, respectively. Post-implementation of BPRs, there was a substantial improvement in guideline adherence to 32.1%, 84.3%, and 83.6% in 2020, 2021, and 2022, respectively. In general, the proportion of BPR-compliant reports of AAA cases in the pre-deployment (3.6%) period statistically differs (p - value < 0.0001) from those in the post-deployment period (73.9%) Conclusion: Adherence to reporting standards increased after the BPR deployment in 2020. The inclusion of management recommendations in the radiology report when AAA is identified is a simple and cost-effective way of improving outcomes for patients with AAAs through appropriate follow-up treatment.
- 26 August 2024
- Published by Heighten Science Publications Corporation in Journal of Clinical Medical and Experimental Images
- Vol. 8 (1) , 007-012
Open AccessEstablishment of a Best Practice Recommendation (BPR) for Abdominal Aortic Aneurysms in a Large Multi-State Radiology Practice: Adoption and Impact
Purpose of the study: To evaluate the performance of Best Practice Recommendation (BPR) compliance in reporting abdominal aortic aneurysm findings on imaging, comparing the results before and after its deployment. Methods: Best Practice Recommendations for AAA were deployed in 2020 at a large radiology practice site. Reports between January 2018 through October 2022 were reviewed, representing studies read prior to and subsequent to the implementation of the reporting standards. Cases of abdominal aortic aneurysms ≥ 2.6 cm were counted by year. Adherence to the BPR for each year was calculated as [total number of confirmed cases of ≥ 2.6 cm AAAs with compliant reports] * 100 / [the total number of confirmed ≥ 2.6 cm AAAs]. A secondary analysis was performed to determine whether there was a statistically significant difference in the proportion of BPR-compliant reports for AAA cases before (from 2018 to 2019) and after (from 2020 to 2022) BPR deployment using a chi-square test. Results: From January 2018 to December 2022, there were 8,693 reports referencing AAA. After excluding cases of suspected AAA (N = 2,131), confirmed AAAs with indeterminate sizes (N = 103), and confirmed AAAs with sizes < 2.6 cm (N = 85), the number of AAA cases ≥ 2.6 cm in size was 6,374. Concordance with the BPR standards for the remaining cases with sizes ≥ 2.6 cm were 1.6% and 4.1% in 2018 and 2019, respectively. Post-implementation of BPRs, there was a substantial improvement in guideline adherence to 32.1%, 84.3%, and 83.6% in 2020, 2021, and 2022, respectively. In general, the proportion of BPR-compliant reports of AAA cases in the pre-deployment (3.6%) period statistically differs (p - value < 0.0001) from those in the post-deployment period (73.9%) Conclusion: Adherence to reporting standards increased after the BPR deployment in 2020. The inclusion of management recommendations in the radiology report when AAA is identified is a simple and cost-effective way of improving outcomes for patients with AAAs through appropriate follow-up treatment.
- Open Access
- 12 June 2024
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (3) , 423-436
Generative Artificial Intelligence Biases, Limitations and Risks in Nuclear Medicine: An Argument for Appropriate Use Framework and Recommendations
- 12 June 2024
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (3) , 423-436
Open AccessGenerative Artificial Intelligence Biases, Limitations and Risks in Nuclear Medicine: An Argument for Appropriate Use Framework and Recommendations
- Open Access
- 25 May 2024
- Published by Elsevier in Radiography
- Vol. 30, 1-8
Challenges confronting sustainability in nuclear medicine practice
- 25 May 2024
- Published by Elsevier in Radiography
- Vol. 30, 1-8
Open AccessChallenges confronting sustainability in nuclear medicine practice
- Open Access
- 6 April 2024
- Published by Elsevier in Radiography
- Vol. 30, 119-124
The potential role of artificial intelligence in sustainability of nuclear medicine
- 6 April 2024
- Published by Elsevier in Radiography
- Vol. 30, 119-124
Open AccessThe potential role of artificial intelligence in sustainability of nuclear medicine
- Open Access
Improving Adherence to Pulmonary Embolism Evaluation Consensus Guidelines: A Multimodal Approach
Objective Despite the publication of multiple widely accepted guidelines, Computed Tomography pulmonary angiography (CTPA) remains overutilized in the emergency (ED) setting for evaluating suspected pulmonary embolism (PE). We developed and evaluated a multimodal program that aimed to improve ordering provider adherence to CTPA use guidelines, and consequently positivity rate. Methods We retrospectively identified all CTPA studies ordered for suspected PE over three years for each provider at a single-center ED, and reviewed radiology reports to determine PE positivity. We then implemented a program that included an education session, individualized performance feedback, and discussion of possible incentives to improve guideline adherence. We prospectively collected CTPA results for the following year. Our primary outcome was the difference in positivity rate between the final preintervention year and the post-intervention year. Our secondary outcome was individual provider positivity rate between the pre-intervention and post-intervention period. We compared the primary outcome using chi-squared testing, defining statistical significance as PResults We identified 4265 CTPA studies performed during the pre-intervention period, ordered by 25 providers. 1582 studies were ordered during the final year, with an 11.00% positivity rate (174/1582). In the post-intervention year, 1339 studies were ordered, with a significantly greater positivity rate of 13.67% (183/1339, P = 0.028). For our secondary outcome, mean provider positivity rate was 11.49% during the preintervention period, and increased to 14.24% in the post-intervention period. Discussion We successfully implemented a multimodal program for ED providers that significantly increased the positivity rate of CTPAs ordered for suspected PE evaluation.
Open AccessImproving Adherence to Pulmonary Embolism Evaluation Consensus Guidelines: A Multimodal Approach
Objective Despite the publication of multiple widely accepted guidelines, Computed Tomography pulmonary angiography (CTPA) remains overutilized in the emergency (ED) setting for evaluating suspected pulmonary embolism (PE). We developed and evaluated a multimodal program that aimed to improve ordering provider adherence to CTPA use guidelines, and consequently positivity rate. Methods We retrospectively identified all CTPA studies ordered for suspected PE over three years for each provider at a single-center ED, and reviewed radiology reports to determine PE positivity. We then implemented a program that included an education session, individualized performance feedback, and discussion of possible incentives to improve guideline adherence. We prospectively collected CTPA results for the following year. Our primary outcome was the difference in positivity rate between the final preintervention year and the post-intervention year. Our secondary outcome was individual provider positivity rate between the pre-intervention and post-intervention period. We compared the primary outcome using chi-squared testing, defining statistical significance as PResults We identified 4265 CTPA studies performed during the pre-intervention period, ordered by 25 providers. 1582 studies were ordered during the final year, with an 11.00% positivity rate (174/1582). In the post-intervention year, 1339 studies were ordered, with a significantly greater positivity rate of 13.67% (183/1339, P = 0.028). For our secondary outcome, mean provider positivity rate was 11.49% during the preintervention period, and increased to 14.24% in the post-intervention period. Discussion We successfully implemented a multimodal program for ED providers that significantly increased the positivity rate of CTPAs ordered for suspected PE evaluation.