KHKai Higashigaito

Kai Higashigaito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Higashigaito has a total of 94 co-authors. Here are the top co-authors by number of shared publications:

  • Hatem Alkadhi

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    6 shared publications
  • Hatem Alkadhi

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V.M., K.C., M.E., L.J., H.A., K.H.).

    5 shared publications
  • André Euler

    Department of Radiology, Kantonsspital Baden, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland

    3 shared publications
  • Matthias Eberhard

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V.M., K.C., M.E., L.J., H.A., K.H.); Department of Radiology, Spital Interlaken, Spitäler fmi AG, Unterseen, Switzerland (M.E.).

    3 shared publications
  • Matthias Eberhard

    Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland

    3 shared publications
  • Robert Manka

    Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland

    3 shared publications

Latest Publications

  • Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT

    by Giulia Cundari, Philipp Deilmann, Victor Mergen, Kristina Ciric, Matthias Eberhard, Lisa Jungblut, Hatem Alkadhi, Kai Higashigaito


  • Open Access

    Detailed bone assessment of the sacroiliac joint in a prospective imaging study: comparison between computed tomography, zero echo time, and black bone magnetic resonance imaging

    by Lucas Wolharn, Roman Guggenberger, Kai Higashigaito, Thomas Sartoretti, Sebastian Winklhofer, Christine B. Chung, Tim Finkenstaedt

    Objectives: To compare the value of zero echo time (ZTE) and gradient echo “black bone” (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. Materials and methods: Between May 2019 and January 2021, 79 patients prospectively underwent clinically indicated 3-T MRI including ZTE and BB imaging. Additionally, all patients underwent a CT scan covering the SI joints within 12 months of the MRI examination. Two blinded readers performed bone assessment by grading each side of each SI joint qualitatively in terms of seven features (osteophytes, subchondral sclerosis, erosions, ankylosis, joint irregularity, joint widening, and gas in the SI joint) using a 4-point Likert scale (0 = no changes–3 = marked changes). Scores were compared between all three imaging modalities. Results: Interreader agreement was largely good (k values: 0.5–0.83). Except for the feature “gas in SI joint” where ZTE exhibited significantly lower scores than CT (p < 0.001), ZTE and BB showed similar performance relative to CT for all other features (p > 0.52) with inter-modality agreement being substantial to almost perfect (Krippendorff’s alpha coefficients: 0.724–0.983). When combining the data from all features except for gas in the SI joint and when binarizing grading scores, combined sensitivity/specificity was 76.7%/98.6% for ZTE and 80.8%/99.1% for BB, respectively, compared to CT. Conclusions: The performance of ZTE and BB sequences was comparable to CT for bone assessment of the SI joint. These sequences may potentially serve as an alternative to CT yet without involving exposure to ionizing radiation.


  • Top Cited Papers

    Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT

    by Kai Higashigaito, André Euler, Matthias Eberhard, Thomas G. Flohr, Bernhard Schmidt, Hatem Alkadhi


  • Photon-Counting CT: Initial Clinical Experience

    by Victor Mergen, André Euler, Kai Higashigaito, Matthias Eberhard, Hatem Alkadhi


  • Top Cited Papers
    Open Access

    Extracellular Volume Quantification With Cardiac Late Enhancement Scanning Using Dual-Source Photon-Counting Detector CT

    by Victor Mergen, Thomas Bmed Sartoretti, Ernst Dipl Phys Klotz, Bernhard Schmidt, Lisa Jungblut, Kai Higashigaito, Robert Manka, André Euler, Markus Kasel, Matthias Eberhard, et al.

    Objectives: The aim of this study was to evaluate the feasibility and accuracy of cardiac late enhancement (LE) scanning for extracellular volume (ECV) quantification with dual-source photon-counting detector computed tomography (PCD-CT). Materials and Methods: In this institutional review board–approved study, 30 patients (mean age, 79 years; 12 women; mean body mass index, 28 kg/m2) with severe aortic stenosis undergoing PCD-CT as part of their preprocedural workup for transcatheter aortic valve replacement were included. The scan protocol consisted of a nonenhanced calcium-scoring scan, coronary CT angiography (CTA) followed by CTA of the thoracoabdominal aorta, and a low-dose LE scan 5 minutes after the administration of 100 mL contrast media (all scans electrocardiogram-gated). Virtual monoenergetic (65 keV) and dual-energy (DE) iodine images were reconstructed from the LE scan. Extracellular volume was calculated using the iodine ratios of myocardium and blood-pool of the LE scan, and additionally based on single-energy (SE) subtraction of the nonenhanced scan from the LE scan. Three-dimensional analysis was performed automatically for the whole-heart myocardial volume by matching a heart model generated from the respective coronary CTA data. Bland-Altman and correlation analysis were used to compare the ECV values determined by both methods. Results: The median dose length product for the LE scan was 84 mGy·cm (interquartile range, 69; 125 mGy·cm). Extracellular volume quantification was feasible in all patients. The median ECV value was 30.5% (interquartile range, 28.4%–33.6%). Two focal ECV elevations matched known prior myocardial infarction. The DE- and SE-based ECV quantification correlated well (r = 0.87, P < 0.001). Bland-Altman analysis showed small mean errors between DE- and SE-based ECV quantification (0.9%; 95% confidence interval, 0.1%–1.6%) with narrow limits of agreement (−3.3% to 5.0%). Conclusions: Dual-source PCD-CT enables accurate ECV quantification using an LE cardiac DE scan at low radiation dose. Extracellular volume calculation from iodine ratios of the LE scan obviates the need for acquisition of a true nonenhanced scan and is not affected by potential misregistration between 2 separate scans.


  • Comparison of detection of trauma-related injuries using combined “all-in-one” fused images and conventionally reconstructed images in acute trauma CT

    by Kai Higashigaito, Gioia Fischer, Lisa Jungblut, Christian Blüthgen, Moritz Schwyzer, Matthias Eberhard, Daniel Pinto dos Santos, Bettina Baessler, Pieter Vuylsteke, Joris A. M. Soons, et al.

    Objectives To compare the accuracy of lesion detection of trauma-related injuries using combined “all-in-one” fused (AIO) and conventionally reconstructed images (CR) in acute trauma CT. Methods In this retrospective study, trauma CT of 66 patients (median age 47 years, range 18–96 years; 20 female (30.3%)) were read using AIO and CR. Images were independently reviewed by 4 blinded radiologists (two residents and two consultants) for trauma-related injuries in 22 regions. Sub-analyses were performed to analyze the influence of experience (residents vs. consultants) and body region (chest, abdomen, skeletal structures) on lesion detection. Paired t-test was used to compare the accuracy of lesion detection. The effect size was calculated (Cohen’s d). Linear mixed-effects model with patients as the fixed effect and random forest models were used to investigate the effect of experience, reconstruction/image processing, and body region on lesion detection. Results Reading time of residents was significantly faster using AIO (AIO: 266 ± 72 s, CR: 318 ± 113 s; p < 0.001; d = 0.46) while no significant difference was observed in the accuracy of lesion detection (AIO: 93.5 ± 6.0%, CR: 94.6 ± 6.0% p = 0.092; d = − 0.21). Reading time of consultants showed no significant difference (AIO: 283 ± 82 s, CR: 274 ± 95 s; p = 0.067; d = 0.16). Accuracy was significantly higher using CR; however, the difference and effect size were very small (AIO 95.1 ± 4.9%, CR: 97.3 ± 3.7%, p = 0.002; d = − 0.39). The linear mixed-effects model showed only minor effect of image processing/reconstruction for lesion detection. Conclusions Residents at the emergency department might benefit from faster reading time without sacrificing lesion detection rate using AIO for trauma CT. Key Points • Image fusion techniques decrease the reading time of acute trauma CT without sacrificing diagnostic accuracy.


  • Open Access

    Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT—First Evidence from Phantom and In-Vivo Scans

    by Matthias Eberhard, Victor Mergen, Kai Higashigaito, Thomas Allmendinger, Robert Manka, Thomas Flohr, Bernhard Schmidt, Andre Euler, Hatem Alkadhi

    We evaluated the accuracy of coronary artery calcium (CAC) scoring on a dual-source photon-counting detector CT (PCD-CT). An anthropomorphic chest phantom underwent ECG-gated sequential scanning on a PCD-CT at 120 kV with four radiation dose levels (CTDIvol, 2.0–8.6 mGy). Polychromatic images at 120 kV (T3D) and virtual monoenergetic images (VMI), from 60 to 75 keV without quantum iterative reconstruction (no QIR) and QIR strength levels 1–4, were reconstructed. For reference, the same phantom was scanned on a conventional energy-integrating detector CT (120 kV; filtered back projection) at identical radiation doses. CAC scoring in 20 patients with PCD-CT (120 kV; no QIR and QIR 1–4) were included. In the phantom, there were no differences between CAC scores of different radiation doses (all, p > 0.05). Images with 70 keV, no QIR (CAC score, 649); 65 keV, QIR 3 (656); 65 keV; QIR4 (648) and T3D, QIR4 (656) showed a p < 0.001) and for each 5 keV-increase (all, p < 0.001). Patient data (median CAC score: 86 [inter-quartile range: 38–978] at 70 keV) confirmed relationships and differences between reconstructions from the phantom. First phantom and in-vivo experience with a clinical dual-source PCD-CT system shows accurate CAC scoring with VMI reconstructions at different radiation dose levels.


  • Open Access

    Ligaments of the scapho-trapezial-trapezoidal joint: MR anatomy in asymptomatic and symptomatic individuals

    by Kai Higashigaito, Christian W. A. Pfirrmann, Sarah Koch, Dimitri Graf, Andreas Schweizer, Daniel Nanz, Andrea B. Rosskopf

    Purpose: To evaluate the MRI anatomy of the scapho-trapezial-trapezoidal (STT) ligament complex in asymptomatic and symptomatic individuals. Material and methods: In this retrospective study, STT ligament complex of 42 (male 69%, median age 37.5 years) asymptomatic (n = 25) and symptomatic (n = 17) (defined as pain described over the STT joint) individuals was examined using a high-resolution 3D proton density-weighted isovoxel sequence (MR arthrogram) with multiplanar reconstructions. Two musculoskeletal radiologists independently assessed visibility, signal intensity (SI), morphology, and thickness of the radiopalmar scapho-trapezial ligament (rpSTL), palmar scapho-capitate capsular ligament (pSCL), palmar STT capsule (pSTTC), and dorsal STT capsule (dSTTC). Results: Interreader agreement ranged from fair to good and intraclass correlations were good. The rpSTL was almost always visible (85.7%/80.1%; reader 1/reader 2). The pSCL and dSTTC were visible in all cases. The pSTTC was visible in only 52.4%/42.9%. Mean thickness of the rpSTL, pSCL, pSTTC, and dSTTC was 1.4 ± 0.5 mm/1.3 ± 0.5 mm, 2.8 ± 0.7 mm/2.7 ± 0.6 mm, 0.5 ± 0.5 mm/0.4 ± 0.4 mm, and 0.5 ± 0.3 mm/0.3 ± 0.3 mm. Both readers rated SI of the rpSTL significantly more often as increased in the symptomatic group (increased SI in asymptomatic group: 20%/15%; symptomatic group: 56%/50%) (p-values < 0.005). For all other ligaments, no significant difference was observed for SI between symptomatic and asymptomatic group (p-values ranging between 0.188 and 0.890). For all other ligaments, no significant differences were observed regarding ligament visibility, morphology, and thickness (p-values ranging between 0.274 and 1.000). Conclusion: The anatomy of the STT ligament complex can consistently be visualized on high-resolution 3D MRI. Increased signal intensity of rpSTL is significantly more frequent in patients with radial-sided wrist pain.


  • Open Access

    The “Balgrist Score” for evaluation of Charcot foot: a predictive value for duration of off-loading treatment

    by Martin C. Berli, Kai Higashigaito, Tobias Götschi, Christian W. A. Pfirrmann, Reto Sutter, Andrea B. Rosskopf

    Objective: To develop a new magnetic resonance imaging(MRI) scoring system for evaluation of active Charcot foot and to correlate the score with a duration of off-loading treatment ≥ 90 days. Methods: An outpatient clinic database was searched retrospectively for MRIs of patients with active Charcot foot who completed off-loading treatment. Images were assessed by two radiologists (readers 1 and 2) and an orthopedic surgeon (reader 3). Sanders/Frykberg regions I–V were evaluated for soft tissue edema, bone marrow edema, erosions, subchondral cysts, joint destruction, fractures, and overall regional manifestation using a score according to degree of severity (0–3 points). Intraclass correlations (ICC) for interreader agreement and receiver operating characteristic analysis between MR findings and duration of off-loading-treatment were calculated. Results: Sixty-five feet in 56 patients (34 men) with a mean age of 62.4 years (range: 44.5–85.5) were included. Region III (reader 1/reader 2: 93.6/90.8%) and region II (92.3/90.8%) were most affected. The most common findings in all regions were soft tissue edema and bone marrow edema. Mean time between MRI and cessation of off-loading-treatment was 150 days (range: 21–405). The Balgrist Score was defined in regions II and III using soft tissue edema, bone marrow edema, joint destruction, and fracture. Interreader agreement for Balgrist Score was excellent: readers 1/2: ICC 0.968 (95% CI: 0.948, 0.980); readers 1/2/3: ICC 0.856 (0.742, 0.917). A cutoff of ≥ 9.0 points in Balgrist Score (specificity 72%, sensitivity 66%) indicated a duration of off-loading treatment ≥ 90 days. Conclusion: The Balgrist Score is a new MR scoring system for assessment of active Charcot foot with excellent interreader agreement. The Balgrist Score can help to identify patients with off-loading treatment ≥ 90 days.


  • CT-based True- and False-Lumen Segmentation in Type B Aortic Dissection Using Machine Learning

    by Lewis D. Hahn, Gabriel Mistelbauer, Kai Higashigaito, Martin Koci, Martin J. Willemink, Anna M. Sailer, Michael Fischbein, Dominik Fleischmann

    The authors developed a five-step segmentation pipeline that segments the true and false lumina on CT angiograms in patients with type B aortic dissection and can be used to derive quantitative mor... PurposeTo develop a segmentation pipeline for segmentation of aortic dissection CT angiograms into true and false lumina on multiplanar reformations (MPRs) perpendicular to the aortic centerline an...