AFAndras B. Fecso

Andras B. Fecso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andras B. Fecso has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Usability, Ergonomics, and Educational Value of a Novel Telestration Tool for Surgical Coaching: Usability Study

    by Parmiss Kiani, Roberta Dolling-Boreham, Mohamed Saif Hameed, Caterina Masino, Andras Fecso, Allan Okrainec, Amin Madani

    Background: Telementoring studies found technical challenges in achieving accurate and stable annotations during live surgery using commercially available telestration software intraoperatively. To address the gap, a wireless handheld telestration device was developed to facilitate dynamic user interaction with live video streams. Objective: This study aims to find the perceived usability, ergonomics, and educational value of a first-generation handheld wireless telestration platform. Methods: A prototype was developed with four core hand-held functions: (1) free-hand annotation, (2) cursor navigation, (3) overlay and manipulation (rotation) of ghost (avatar) instrumentation, and (4) hand-held video feed navigation on a remote monitor. This device uses a proprietary augmented reality platform. Surgeons and trainees were invited to test the core functions of the platform by performing standardized tasks. Usability and ergonomics were evaluated with a validated system usability scale and a 5-point Likert scale survey, which also evaluated the perceived educational value of the device. Results: In total, 10 people (9 surgeons and 1 senior resident; 5 male and 5 female) participated. Participants strongly agreed or agreed (SA/A) that it was easy to perform annotations (SA/A 9, 90% and neutral 0, 0%), video feed navigation (SA/A 8, 80% and neutral 1, 10%), and manipulation of ghost (avatar) instruments on the monitor (SA/A 6, 60% and neutral 3, 30%). Regarding ergonomics, 40% (4) of participants agreed or strongly agreed (neutral 4, 40%) that the device was physically comfortable to use and hold. These results are consistent with open-ended comments on the device’s size and weight. The average system usability scale was 70 (SD 12.5; median 75, IQR 63-84) indicating an above average usability score. Participants responded favorably to the device’s perceived educational value, particularly for postoperative coaching (agree 6, 60%, strongly agree 4, 40%). Conclusions: This study presents the preliminary usability results of a novel first-generation telestration tool customized for use in surgical coaching. Favorable usability and perceived educational value were reported. Future iterations of the device should focus on incorporating user feedback and additional studies should be conducted to evaluate its effectiveness for improving surgical education. Ultimately, such tools can be incorporated into pedagogical models of surgical coaching to optimize feedback and training.


  • Educational value of a novel telestration device for surgical coaching—a randomized controlled trial

    by Mohamed Saif Hameed, Parmiss Kiani, Priyanka Kugamoorthy, Caterina Masino, Nastasia Kujbid, Simon Laplante, Allan Okrainec, Amin Madani, Andras B. Fecso

    Introduction Communication is fundamental to effective surgical coaching. This can be challenging for training during image-guided procedures where coaches and trainees need to articulate technical details on a monitor. Telestration devices that annotate on monitors remotely could potentially overcome these limitations and enhance the coaching experience. This study aims to evaluate the value of a novel telestration device in surgical coaching. Methods A randomized-controlled trial was designed. All participants watched a video demonstrating the task followed by a baseline performance assessment and randomization into either control group (conventional verbal coaching without telestration) or telestration group (verbal coaching with telestration). Coaching for a simulated laparoscopic small bowel anastomosis on a dry lab model was done by a faculty surgeon. Following the coaching session, participants underwent a post-coaching performance assessment of the same task. Assessments were recorded and rated by blinded reviewers using a modified Global Rating Scale of the Objective Structured Assessment of Technical Skills (OSATS). Coaching sessions were also recorded and compared in terms of mentoring moments; guidance misinterpretations, questions/clarifications by trainees, and task completion time. A 5-point Likert scale was administered to obtain feedback. Results Twenty-four residents participated (control group 13, telestration group 11). Improvements in some elements of the OSATS scale were noted in the Telestration arm but there was no statistical significance in the overall score between the two groups. Mentoring moments were more in the telestration Group. Amongst the telestration Group, 55% felt comfortable that they could perform this task independently, compared to only 8% amongst the control group and 82% would recommend the use of telestration tools here. Conclusion There is demonstrated educational value of this novel telestration device mainly in the non-technical aspects of the interaction by enhancing the coaching experience with improvement in communication and greater mentoring moments between coach and trainee.


  • Open Access

    Usability, Ergonomics, and Educational Value of a Novel Telestration Tool for Surgical Coaching: Usability Study (Preprint)

    by Parmiss Kiani, Roberta Dolling-Boreham, Mohamed Saif Hameed, Caterina Masino, Andras Fecso, Allan Okrainec, Amin Madani

    BACKGROUND Telementoring studies found technical challenges in achieving accurate and stable annotations during live surgery using commercially available telestration software intraoperatively. To address the gap, a wireless handheld telestration device was developed to facilitate dynamic user interaction with live video streams. OBJECTIVE This study aims to find the perceived usability, ergonomics, and educational value of a first-generation handheld wireless telestration platform. METHODS A prototype was developed with four core hand-held functions: (1) free-hand annotation, (2) cursor navigation, (3) overlay and manipulation (rotation) of ghost (avatar) instrumentation, and (4) hand-held video feed navigation on a remote monitor. This device uses a proprietary augmented reality platform. Surgeons and trainees were invited to test the core functions of the platform by performing standardized tasks. Usability and ergonomics were evaluated with a validated system usability scale and a 5-point Likert scale survey, which also evaluated the perceived educational value of the device. RESULTS In total, 10 people (9 surgeons and 1 senior resident; 5 male and 5 female) participated. Participants strongly agreed or agreed (SA/A) that it was easy to perform annotations (SA/A 9, 90% and neutral 0, 0%), video feed navigation (SA/A 8, 80% and neutral 1, 10%), and manipulation of ghost (avatar) instruments on the monitor (SA/A 6, 60% and neutral 3, 30%). Regarding ergonomics, 40% (4) of participants agreed or strongly agreed (neutral 4, 40%) that the device was physically comfortable to use and hold. These results are consistent with open-ended comments on the device’s size and weight. The average system usability scale was 70 (SD 12.5; median 75, IQR 63-84) indicating an above average usability score. Participants responded favorably to the device’s perceived educational value, particularly for postoperative coaching (agree 6, 60%, strongly agree 4, 40%). CONCLUSIONS This study presents the preliminary usability results of a novel first-generation telestration tool customized for use in surgical coaching. Favorable usability and perceived educational value were reported. Future iterations of the device should focus on incorporating user feedback and additional studies should be conducted to evaluate its effectiveness for improving surgical education. Ultimately, such tools can be incorporated into pedagogical models of surgical coaching to optimize feedback and training. CLINICALTRIAL


  • What is the educational value and clinical utility of artificial intelligence for intraoperative and postoperative video analysis? A survey of surgeons and trainees

    by M. Saif Hameed, Simon Laplante, Caterina Masino, Muhammad Uzair Khalid, Haochi Zhang, Sergey Protserov, Jaryd Hunter, Pouria Mashouri, Andras B. Fecso, Michael Brudno, et al.

    Introduction Surgical complications often occur due to lapses in judgment and decision-making. Advances in artificial intelligence (AI) have made it possible to train algorithms that identify anatomy and interpret the surgical field. These algorithms can potentially be used for intraoperative decision-support and postoperative video analysis and feedback. Despite the very early success of proof-of-concept algorithms, it remains unknown whether this innovation meets the needs of end-users or how best to deploy it. This study explores users’ opinion on the value, usability and design for adapting AI in operating rooms. Methods A device-agnostic web-accessible software was developed to provide AI inference either (1) intraoperatively on a live video stream (synchronous mode), or (2) on an uploaded video or image file (asynchronous mode) postoperatively for feedback. A validated AI model (GoNoGoNet), which identifies safe and dangerous zones of dissection during laparoscopic cholecystectomy, was used as the use case. Surgeons and trainees performing laparoscopic cholecystectomy interacted with the AI platform and completed a 5-point Likert scale survey to evaluate the educational value, usability and design of the platform. Results Twenty participants (11 surgeons and 9 trainees) evaluated the platform intraoperatively (n = 10) and postoperatively (n = 11). The majority agreed or strongly agreed that AI is an effective adjunct to surgical training (81%; neutral = 10%), effective for providing real-time feedback (70%; neutral = 20%), postoperative feedback (73%; neutral = 27%), and capable of improving surgeon confidence (67%; neutral = 29%). Only 40% (neutral = 50%) and 57% (neutral = 43%) believe that the tool is effective in improving intraoperative decisions and performance, or beneficial for patient care, respectively. Overall, 38% (neutral = 43%) reported they would use this platform consistently if available. The majority agreed or strongly agreed that the platform was easy to use (81%; neutral = 14%) and has acceptable resolution (62%; neutral = 24%), while 30% (neutral = 20%) reported that it disrupted the OR workflow, and 20% (neutral = 0%) reported significant time lag. All respondents reported that such a system should be available “on-demand” to turn on/off at their discretion. Conclusions Most found AI to be a useful tool for providing support and feedback to surgeons, despite several implementation obstacles. The study findings will inform the future design and usability of this technology in order to optimize its clinical impact and adoption by end-users.


  • Open Access

    Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography for patients with Roux-en-Y gastric bypass anatomy: technical overview

    by Hirokazu Honda, Jeffrey D. Mosko, Ryosuke Kobayashi, Andras Fecso, Bong Sik Kim, Schoeman Scott, Gary R. May

    Endoscopic retrograde cholangiopancreatography (ERCP) in patients with Roux-en-Y gastric bypass anatomy is a well-documented challenge. Traditionally, this problem has been overcome with adjunctive techniques, such as device-assisted ERCP, including double-balloon or single-balloon enteroscopy and laparoscopy-assisted transgastric ERCP. Endoscopic ultrasound-directed transgastric ERCP (EDGE) is a novel technique that enables access to the ampulla using a duodenoscope without surgical intervention and has shown high clinical and technical success rates in recent studies. However, this approach is technically demanding, necessitating a thorough understanding of the gastrointestinal anatomy as well as high operator experience. In this review, we provide a technical overview of EDGE in parallel with our personal experience at our center and propose a simple algorithm to select patients for its appropriate application. In conjunction, the outcomes of EDGE compared with those of device-assisted and laparoscopy-assisted transgastric ERCP will be discussed.


  • ACCURACY OF OPTICAL DIAGNOSIS IN ENDOSCOPY AT A TERTIARY ACADEMIC CENTRE

    by Chandni Pattni, Andras B. Fecso, Sechiv Jugnundan, Sarang Gupta, Samir C. Grover, Christopher Teshima, Jeffrey D. Mosko

  • Open Access

    Development of a simulation curriculum to teach and assess advanced laparoscopic suturing skills using telesimulation: a feasibility study

    by Elif Bilgic, Allan Okrainec, Sofia Valanci, Adam Di Palma, Andras Fecso, Pepa Kaneva, Caterina Masino, Yusuke Watanabe, Melina C. Vassiliou, Liane S. Feldman, et al.

    Background Telesimulation helps overcome limitations in time and local expertise by eliminating the need for the learner and educator to be physically co-located, especially important during COVID-19. We investigated whether teaching advanced laparoscopic suturing (ALS) through telesimulation is feasible, effective, and leads to improved suturing in the operating room (OR). Methods In this prospective feasibility study, three previously developed 3D-printed ALS tasks were used: needle handling (NH), suturing under tension (UT), and continuous suturing (CS). General surgery residents (PGY4-5) underwent 1-month of telesimulation training, during which an expert educator at one site remotely trained residents at the other site over 2–3 teaching sessions. Trainees were assessed in the three tasks and in the OR at three time points: baseline(A1), control period(A2), and post-intervention(A3) and completed questionnaires regarding educational value and usability of telesimulation. Paired t-test was used to compare scores between the three assessment points. Results Six residents were included. Scores for UT improved significantly post-intervention A3(568 ± 60) when compared to baseline A1(416 ± 133) (p < 0.019). Similarly, scores for CS improved significantly post-intervention A3(756 ± 113) vs. baseline A1(539 ± 211) (p < 0.02). For intraoperative assessments, scores improved significantly post-intervention A3(21 ± 3) when compared to both A1(17 ± 4) (p < 0.018) and A2(18 ± 4) (p < 0.0008). All residents agreed that tasks were relevant to practice, helped improve technical competence, and adequately measured suturing skill. All residents found telesimulation easy to use, had strong educational value, and want the system to be incorporated into their training. Conclusion The use of telesimulation for remotely training residents using ALS tasks was feasible and effective. Residents found value in training using the tasks and telesimulation system, and improved ALS skills in the OR. As the pandemic has caused a major structural shift in resident education, telesimulation can be an effective alternative to on-site simulation programs. Future research should focus on how telesimulation can be effectively incorporated into training programs.


  • Reply to

    by Andras B. Fecso, Peter Szasz, Georgi Kerezov, Teodor P. Grantcharov

  • Relationship between intraoperative non-technical performance and technical events in bariatric surgery

    by A. B. Fecso, S. S. Kuzulugil, C. Babaoglu, A. B. Bener, T. P. Grantcharov

    Background The operating theatre is a unique environment with complex team interactions, where technical and non‐technical performance affect patient outcomes. The correlation between technical and non‐technical performance, however, remains underinvestigated. The purpose of this study was to explore these interactions in the operating theatre. Methods A prospective single‐centre observational study was conducted at a tertiary academic medical centre. One surgeon and three fellows participated as main operators. All patients who underwent a laparoscopic Roux‐en‐Y gastric bypass and had the procedures captured using the Operating Room Black Box® platform were included. Technical assessment was performed using the Objective Structured Assessment of Technical Skills and Generic Error Rating Tool instruments. For non‐technical assessment, the Non‐Technical Skills for Surgeons (NOTSS) and Scrub Practitioners' List of Intraoperative Non‐Technical Skills (SPLINTS) tools were used. Spearman rank‐order correlation and N‐gram statistics were conducted. Results Fifty‐six patients were included in the study and 90 procedural steps (gastrojejunostomy and jejunojejunostomy) were analysed. There was a moderate to strong correlation between technical adverse events (rs = 0·417–0·687), rectifications (rs = 0·380–0·768) and non‐technical performance of the surgical and nursing teams (NOTSS and SPLINTS). N‐gram statistics showed that after technical errors, events and prior rectifications, the staff surgeon and the scrub nurse exhibited the most positive non‐technical behaviours, irrespective of operator (staff surgeon or fellow). Conclusion This study demonstrated that technical and non‐technical performances are related, on both an individual and a team level. Valuable data can be obtained around intraoperative errors, events and rectifications.


  • Studying the Interactions Between Teams and Individuals in the Operating Room: A Pilot Study

    by Andras B. Fecso, Sebnem S. Kuzulugil, Ceni Babaoglu, Ayse B. Bener, Teodor P. Grantcharov