Jorge A. Galvez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jorge A. Galvez has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
- Allan F. Simpao
Department of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA
29 shared publications Mohamed A. Rehman
Department of Anesthesiology, Johns Hopkins All Children's Hospital, St. Petersburg, Florida
17 shared publicationsLuis Ahumada
Predictive Analytics Johns Hopkins All Children’s Hospital St. Petersburg FL USA
6 shared publicationsAlan Jay Schwartz
From the Department of Anesthesiology and Critical Care Medicine, The Children’s Hospital of Philadelphia, and Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
4 shared publicationsArul M. Lingappan
Department of Anesthesiology & Critical Care Medicine, The Children's Hospital of Philadelphia, Pennsylvania
4 shared publications- Harshad Gurnaney
Associate professor, Department of Anesthesiology and Critical Care Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania; ; ORCID: http://orcid.org
4 shared publications
Latest Publications
- 1 December 2020
- Published by Wiley in Transfusion
- Vol. 60 (12) , 2787-2792
How do I horizontal ellipsis Incorporate a two-sample blood type verification in a pediatric hospital?
Background The AABB (American Association of Blood Banks) and the College of American Pathologists (CAP) regulations call on blood banks to address the risk of misidentification of a patient's blood type, which can result in transfusion of a mismatched product. Transfusion of mismatched blood product is potentially fatal due to acute hemolytic transfusion reaction and is considered a preventable event. CAP regulations outline options to reduce risk of mistransfusion by either documenting the ABO group of the intended recipient on a second sample collected at a separate phlebotomy, or utilizing a mechanical barrier system or electronic identification verification system that ensures the patient from whom the pretransfusion specimen was collected is the same patient who is about to be transfused. Study Design and Methods An electronic or barrier system was not available for implementation at our institution, therefore we developed a protocol for a two-sample verification system. The first determination is performed on a current sample and the second by one of the following methods: (a) comparison with previous laboratory records, (b) testing a second sample collected at a time different from the first sample (i.e., laboratory specimen available with a different timestamp, or a new blood sample). Results We improved our transfusion process and implemented a policy to require a second sample to confirm a patient's blood type. We also implemented workflows to obtain blood type confirmation from history of a second blood type result from previous laboratory records, including a policy to accept previous blood type records from an outside laboratory. Conclusions We describe a practice change for two-sample verification for type and screen in a large-scale pediatric hospital. We outline specific workflows for pre-operative and emergency transfusion scenarios, and pediatric-specific challenges.
- 1 December 2020
- Published by Wiley in Transfusion
- Vol. 60 (12) , 2787-2792
How do I horizontal ellipsis Incorporate a two-sample blood type verification in a pediatric hospital?
Background The AABB (American Association of Blood Banks) and the College of American Pathologists (CAP) regulations call on blood banks to address the risk of misidentification of a patient's blood type, which can result in transfusion of a mismatched product. Transfusion of mismatched blood product is potentially fatal due to acute hemolytic transfusion reaction and is considered a preventable event. CAP regulations outline options to reduce risk of mistransfusion by either documenting the ABO group of the intended recipient on a second sample collected at a separate phlebotomy, or utilizing a mechanical barrier system or electronic identification verification system that ensures the patient from whom the pretransfusion specimen was collected is the same patient who is about to be transfused. Study Design and Methods An electronic or barrier system was not available for implementation at our institution, therefore we developed a protocol for a two-sample verification system. The first determination is performed on a current sample and the second by one of the following methods: (a) comparison with previous laboratory records, (b) testing a second sample collected at a time different from the first sample (i.e., laboratory specimen available with a different timestamp, or a new blood sample). Results We improved our transfusion process and implemented a policy to require a second sample to confirm a patient's blood type. We also implemented workflows to obtain blood type confirmation from history of a second blood type result from previous laboratory records, including a policy to accept previous blood type records from an outside laboratory. Conclusions We describe a practice change for two-sample verification for type and screen in a large-scale pediatric hospital. We outline specific workflows for pre-operative and emergency transfusion scenarios, and pediatric-specific challenges.
- 20 November 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 134 (1) , 9-10
Aerosol Retention Barriers
- 20 November 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 134 (1) , 9-10
Aerosol Retention Barriers
- 15 November 2020
- Published by Wiley in Pediatric Anesthesia
- Vol. 31 (2) , 186-196
Audit of blood product utilization in the care of injured children
Background Blood product utilization in injured children is poorly characterized; the decision to prepare products or transfuse patients can be difficult due to a lack of reliable evidence of transfusion needs across pediatric age groups and injury types. We conducted an audit of transfusion practices in pediatric trauma based on age, injuries and mechanism of injury. Methods We reviewed and cross‐referenced blood product transfusion practice data from the trauma registry and the anesthesia transfusion record database at a Level 1 Pediatric Trauma Center over a 10‐year period. Demographic data, injury severity scores, and survival statistics were obtained from the trauma registry. Transfusion rates are reported separately for hospital admission and for intraoperative transfusions for procedures performed during the first two hospital days. Descriptive statistical analysis was used to compare specific groups based on age, injury type, mechanism of injury. Results We report 14,569 trauma admissions of 14,606 patients. The transfusion rate during the admission was 1.56% (227/14,569).4,591 (30.9%) admissions had surgical interventions in first two days of hospitalization with an intraoperative transfusion rate of 2.98%. Patients younger than one year had the highest transfusion rate during admission (2.8%) and the highest transfusion rate duringsurgical procedures performed in the first two days of the admission (18.87%). Admissions due to vascular injuries had the highest transfusion ratesin infancy followed by hollow visceral injuries in adolescents (71.4%, 25% respectively). Vascular injuries in most age groups also had high transfusion ratesranging from 11% in 5‐9 age group to 71% in infants. Mechanisms with the highest transfusion rateswere firearm wounds in patients older than one year and vehicular accidents for patients younger than one year. Conclusions Theoverall blood product needs in the pediatric trauma population are low (1.56%). Selected populations requiring higher rates of need include infants younger than one year, and children with thoracic and vascular injuries . Understanding transfusion patterns is important to optimize resource allocation.
- 15 November 2020
- Published by Wiley in Pediatric Anesthesia
- Vol. 31 (2) , 186-196
Audit of blood product utilization in the care of injured children
Background Blood product utilization in injured children is poorly characterized; the decision to prepare products or transfuse patients can be difficult due to a lack of reliable evidence of transfusion needs across pediatric age groups and injury types. We conducted an audit of transfusion practices in pediatric trauma based on age, injuries and mechanism of injury. Methods We reviewed and cross‐referenced blood product transfusion practice data from the trauma registry and the anesthesia transfusion record database at a Level 1 Pediatric Trauma Center over a 10‐year period. Demographic data, injury severity scores, and survival statistics were obtained from the trauma registry. Transfusion rates are reported separately for hospital admission and for intraoperative transfusions for procedures performed during the first two hospital days. Descriptive statistical analysis was used to compare specific groups based on age, injury type, mechanism of injury. Results We report 14,569 trauma admissions of 14,606 patients. The transfusion rate during the admission was 1.56% (227/14,569).4,591 (30.9%) admissions had surgical interventions in first two days of hospitalization with an intraoperative transfusion rate of 2.98%. Patients younger than one year had the highest transfusion rate during admission (2.8%) and the highest transfusion rate duringsurgical procedures performed in the first two days of the admission (18.87%). Admissions due to vascular injuries had the highest transfusion ratesin infancy followed by hollow visceral injuries in adolescents (71.4%, 25% respectively). Vascular injuries in most age groups also had high transfusion ratesranging from 11% in 5‐9 age group to 71% in infants. Mechanisms with the highest transfusion rateswere firearm wounds in patients older than one year and vehicular accidents for patients younger than one year. Conclusions Theoverall blood product needs in the pediatric trauma population are low (1.56%). Selected populations requiring higher rates of need include infants younger than one year, and children with thoracic and vascular injuries . Understanding transfusion patterns is important to optimize resource allocation.
- 1 June 2020
- Published by Wiley in Pediatric Anesthesia
- Vol. 30 (9) , 1027-1032
Exhaled nitric oxide measurement before pediatric adenotonsillectomy: A feasibility study
Background Exhaled nitric oxide (eNO) is a known biomarker for the diagnosis and monitoring of bronchial hyperreactivityin adults and children. Aims To investigatethe potential role of eNOmeasurement for predicting perioperative respiratory adverse events in children, we sought to determine its feasibility and acceptability before adenotonsillectomy. Methods We attempted eNO testing in children, 4 to 12 years of age, immediately prior to admission for outpatient adenotonsillectomy. We used correlations between eNO levels and postoperative adverse respiratory events to make sample size predictions for future studies that address the predictability of the device. Results One hundred three (53%) of 192 children were able to provide an eNO sample. The success rate increased with age from 23% [9%‐38%] at age 4 to over 85% [54% ‐ 98%] after age 9.Using the eNO normal value (< 20 ppb) as a cutoff, an expected sample size to detect a significant difference between children with and without adverse events is 868, assuming that respiratory adverse events occur in 29% of children. Conclusions eNO testing on the day of surgery has limited feasibility in children younger than 7 years of age. The most common reason for failure was inadequate physical performance while interacting with the testing device. The role of this respiratory biomarker in the context of perioperative outcomes for pediatric adenotonsillectomy remains unknown and should be further studied with improved technologies.
- 1 June 2020
- Published by Wiley in Pediatric Anesthesia
- Vol. 30 (9) , 1027-1032
Exhaled nitric oxide measurement before pediatric adenotonsillectomy: A feasibility study
Background Exhaled nitric oxide (eNO) is a known biomarker for the diagnosis and monitoring of bronchial hyperreactivityin adults and children. Aims To investigatethe potential role of eNOmeasurement for predicting perioperative respiratory adverse events in children, we sought to determine its feasibility and acceptability before adenotonsillectomy. Methods We attempted eNO testing in children, 4 to 12 years of age, immediately prior to admission for outpatient adenotonsillectomy. We used correlations between eNO levels and postoperative adverse respiratory events to make sample size predictions for future studies that address the predictability of the device. Results One hundred three (53%) of 192 children were able to provide an eNO sample. The success rate increased with age from 23% [9%‐38%] at age 4 to over 85% [54% ‐ 98%] after age 9.Using the eNO normal value (< 20 ppb) as a cutoff, an expected sample size to detect a significant difference between children with and without adverse events is 868, assuming that respiratory adverse events occur in 29% of children. Conclusions eNO testing on the day of surgery has limited feasibility in children younger than 7 years of age. The most common reason for failure was inadequate physical performance while interacting with the testing device. The role of this respiratory biomarker in the context of perioperative outcomes for pediatric adenotonsillectomy remains unknown and should be further studied with improved technologies.
- 13 April 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 133 (1) , 237-238
Analysis of Laryngoscopy Attempts in Infants: Reply
We thank Dr. Horvath for his correspondence1 regarding our study of the association between infant laryngoscopy attempts and hypoxemia.2 We agree that infants experience higher risks of respiratory adverse events during tracheal intubation than adults. Although the American Society of Anesthesiologists (Schaumburg, Illinois; ASA) provides definitions and clinical examples to guide the use of the ASA Physical Status system, Dr. Horvath states correctly that a patient’s age is not considered.3 Dr. Horvath’s suggestion of updating the definitions for the ASA Physical Status system for pediatric patients is worthy of discussion. Assigning ASA Physical Status II to healthy infants because of higher rates of adverse events during tracheal intubation might be problematic. First, the purpose of the ASA Physical Status classification system is to communicate the patient’s medical comorbidities, not their anesthetic risk. Second, if age were considered a comorbidity then one would have to assign a higher status for patients at both extremes of age, not just infants. Finally, a rapid sequence induction in a child increases the risk of hypoxemia during laryngoscopy, yet ASA Physical Status is not typically adjusted because of a plan for rapid sequence induction. There are many clinical scenarios wherein infants may be classified appropriately as ASA Physical Status I, such as a 3-month-old patient undergoing a circumcision. Although direct laryngoscopy can be challenging in infants, there are alternatives for establishing an airway, including supraglottic airways and video laryngoscopy, that may be less challenging than direct laryngoscopy.
- 13 April 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 133 (1) , 237-238
Analysis of Laryngoscopy Attempts in Infants: Reply
We thank Dr. Horvath for his correspondence1 regarding our study of the association between infant laryngoscopy attempts and hypoxemia.2 We agree that infants experience higher risks of respiratory adverse events during tracheal intubation than adults. Although the American Society of Anesthesiologists (Schaumburg, Illinois; ASA) provides definitions and clinical examples to guide the use of the ASA Physical Status system, Dr. Horvath states correctly that a patient’s age is not considered.3 Dr. Horvath’s suggestion of updating the definitions for the ASA Physical Status system for pediatric patients is worthy of discussion. Assigning ASA Physical Status II to healthy infants because of higher rates of adverse events during tracheal intubation might be problematic. First, the purpose of the ASA Physical Status classification system is to communicate the patient’s medical comorbidities, not their anesthetic risk. Second, if age were considered a comorbidity then one would have to assign a higher status for patients at both extremes of age, not just infants. Finally, a rapid sequence induction in a child increases the risk of hypoxemia during laryngoscopy, yet ASA Physical Status is not typically adjusted because of a plan for rapid sequence induction. There are many clinical scenarios wherein infants may be classified appropriately as ASA Physical Status I, such as a 3-month-old patient undergoing a circumcision. Although direct laryngoscopy can be challenging in infants, there are alternatives for establishing an airway, including supraglottic airways and video laryngoscopy, that may be less challenging than direct laryngoscopy.
- 1 March 2020
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 130, 109807
Secondhand Smoke exposure and risk of Obstructive Sleep Apnea in Children
- 1 March 2020
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 130, 109807
Secondhand Smoke exposure and risk of Obstructive Sleep Apnea in Children
- 1 February 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 132 (2) , 402
Digital Healing: People, Information, Healthcare
- 1 February 2020
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 132 (2) , 402
Digital Healing: People, Information, Healthcare
- 1 January 2020
- Published by Wiley in Pediatric Anesthesia
- Vol. 30 (4) , 446-454
Reducing postoperative nausea and vomiting in pediatric patients undergoing anterior cruciate ligament reconstruction: A quality report
Background: Postoperative nausea and vomiting after elective outpatient surgery can complicate discharge and increase patient suffering. Within our hospital system, there was variability in the use of postoperative nausea and vomiting prophylaxis for patients undergoing anterior cruciate ligament reconstruction, which resulted in variable outcomes. To address this variability, we designed and implemented a standardized postoperative nausea and vomiting prophylaxis guideline for the care of this surgical population.Aim: We sought to develop and implement a standardized postoperative nausea and vomiting prophylaxis guideline for all patients presenting for elective ambulatory anterior cruciate ligament reconstruction with the goal of reducing the rate of emesis to ≤5%.Methods: We convened a multidisciplinary team to develop a postoperative nausea and vomiting prophylaxis guideline which included administration of dexamethasone, ondansetron, and a low‐dose propofol infusion in addition to a femoral and sciatic nerve block and routine ketorolac administration for pain control. Our primary outcome, emesis rate, was tracked using a P‐chart. Process measures included use of guideline medications and balancing measures included opioid administration, pain scores, and emergence time.Results: We analyzed postoperative nausea and vomiting outcomes for 817 patients from January 1, 2014, to December 31, 2018. The baseline postoperative emesis rate for all anesthetizing locations was 17%. Following, guideline implementation, the emesis rate decreased to 5%. Opioid administration was decreased following guideline implementation. The percentage of patients managed without any perioperative opioids increased from 16% in the baseline group to 38% following guideline implementation. The P‐chart suggests that the observed reduction in emesis rate represents special cause variation and this reduction was sustained over a two‐year period.Conclusions: Implementation of standard postoperative nausea and vomiting guidelines for adolescents undergoing outpatient anterior cruciate ligament reconstruction was associated with lower emesis rates. This reduction in emesis rate may have been due to the concurrent reduction in opioids we observed following guideline implementation.
- 1 January 2020
- Published by Wiley in Pediatric Anesthesia
- Vol. 30 (4) , 446-454
Reducing postoperative nausea and vomiting in pediatric patients undergoing anterior cruciate ligament reconstruction: A quality report
Background: Postoperative nausea and vomiting after elective outpatient surgery can complicate discharge and increase patient suffering. Within our hospital system, there was variability in the use of postoperative nausea and vomiting prophylaxis for patients undergoing anterior cruciate ligament reconstruction, which resulted in variable outcomes. To address this variability, we designed and implemented a standardized postoperative nausea and vomiting prophylaxis guideline for the care of this surgical population.Aim: We sought to develop and implement a standardized postoperative nausea and vomiting prophylaxis guideline for all patients presenting for elective ambulatory anterior cruciate ligament reconstruction with the goal of reducing the rate of emesis to ≤5%.Methods: We convened a multidisciplinary team to develop a postoperative nausea and vomiting prophylaxis guideline which included administration of dexamethasone, ondansetron, and a low‐dose propofol infusion in addition to a femoral and sciatic nerve block and routine ketorolac administration for pain control. Our primary outcome, emesis rate, was tracked using a P‐chart. Process measures included use of guideline medications and balancing measures included opioid administration, pain scores, and emergence time.Results: We analyzed postoperative nausea and vomiting outcomes for 817 patients from January 1, 2014, to December 31, 2018. The baseline postoperative emesis rate for all anesthetizing locations was 17%. Following, guideline implementation, the emesis rate decreased to 5%. Opioid administration was decreased following guideline implementation. The percentage of patients managed without any perioperative opioids increased from 16% in the baseline group to 38% following guideline implementation. The P‐chart suggests that the observed reduction in emesis rate represents special cause variation and this reduction was sustained over a two‐year period.Conclusions: Implementation of standard postoperative nausea and vomiting guidelines for adolescents undergoing outpatient anterior cruciate ligament reconstruction was associated with lower emesis rates. This reduction in emesis rate may have been due to the concurrent reduction in opioids we observed following guideline implementation.
- 19 December 2019
- Published by Wiley in Pediatric Anesthesia
- Vol. 30 (2) , 137-146
Duration of preoperative clear fluid fasting and peripheral intravenous catheterization in children: A single‐center observational cohort study of 9693 patients
Background: Children routinely undergo inhalational induction of general anesthesia. Intravenous line placement typically occurs after induction of anesthesia and can be challenging, particularly in infants and young children.Aims: We conducted a retrospective observational study to determine whether there was an association between clear liquid fasting time and the number of peripheral intravenous catheter insertion attempts in anesthetized children. The secondary aim was to identify factors associated with multiple attempts to insert intravenous lines.Methods: After institutional research board approval, we retrieved a data set of all children between 0 months and 18 years who received general anesthesia at our hospital between January 1, 2016, and September 30, 2017. Data included age, gender, weight, race, ASA status, gestational age, number of peripheral intravenous catheter insertion attempts, any assistive device for insertion, and insertion site. Inclusion criteria were mask induction, ASA status 1 or 2, nonemergency, ambulatory surgical procedures, and placement of a single intravenous line during the anesthetic.Results: A total of 9693 patients were included in the study. Of which 8869 patients required one insertion attempt and 824 underwent multiple insertion attempts. 50% of patients in the single insertion attempt group had clear liquid fasting time P = .47).Conclusion: Clear liquid fasting time was not associated with multiple insertion attempts for intravenous line insertion in children receiving general anesthesia. Factors such as patient age, ethnicity, time of day of induction of anesthesia, and American Society of Anesthesiologists Physical Status classification show a greater association with the risk of multiple intravenous line insertion attempts.
- 19 December 2019
- Published by Wiley in Pediatric Anesthesia
- Vol. 30 (2) , 137-146
Duration of preoperative clear fluid fasting and peripheral intravenous catheterization in children: A single‐center observational cohort study of 9693 patients
Background: Children routinely undergo inhalational induction of general anesthesia. Intravenous line placement typically occurs after induction of anesthesia and can be challenging, particularly in infants and young children.Aims: We conducted a retrospective observational study to determine whether there was an association between clear liquid fasting time and the number of peripheral intravenous catheter insertion attempts in anesthetized children. The secondary aim was to identify factors associated with multiple attempts to insert intravenous lines.Methods: After institutional research board approval, we retrieved a data set of all children between 0 months and 18 years who received general anesthesia at our hospital between January 1, 2016, and September 30, 2017. Data included age, gender, weight, race, ASA status, gestational age, number of peripheral intravenous catheter insertion attempts, any assistive device for insertion, and insertion site. Inclusion criteria were mask induction, ASA status 1 or 2, nonemergency, ambulatory surgical procedures, and placement of a single intravenous line during the anesthetic.Results: A total of 9693 patients were included in the study. Of which 8869 patients required one insertion attempt and 824 underwent multiple insertion attempts. 50% of patients in the single insertion attempt group had clear liquid fasting time P = .47).Conclusion: Clear liquid fasting time was not associated with multiple insertion attempts for intravenous line insertion in children receiving general anesthesia. Factors such as patient age, ethnicity, time of day of induction of anesthesia, and American Society of Anesthesiologists Physical Status classification show a greater association with the risk of multiple intravenous line insertion attempts.
- Open Access
- 1 October 2019
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 131 (4) , 830-839
Hypoxemia, Bradycardia, and Multiple Laryngoscopy Attempts during Anesthetic Induction in Infants
Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: Background: The infant airway is particularly vulnerable to trauma from repeated laryngoscopy attempts. Complications associated with elective tracheal intubations in anesthetized infants may be underappreciated. We conducted this study of anesthetized infants to determine the incidence of multiple laryngoscopy attempts during routine tracheal intubation and assess the association of laryngoscopy attempts with hypoxemia and bradycardia. Methods: We conducted a retrospective cross-sectional cohort study of anesthetized infants (age less than or equal to 12 months) who underwent direct laryngoscopy for oral endotracheal intubation between January 24, 2015, and August 1, 2016. We excluded patients with a history of difficult intubation and emergency procedures. Our primary outcome was the incidence of hypoxemia or bradycardia during induction of anesthesia. We evaluated the relationship between laryngoscopy attempts and our primary outcome, adjusting for age, weight, American Society of Anesthesiologists status, staffing model, and encounter location. Results: A total of 1,341 patients met our inclusion criteria, and 16% (n = 208) had multiple laryngoscopy attempts. The incidence of hypoxemia was 35% (n = 469) and bradycardia was 8.9% (n = 119). Hypoxemia and bradycardia occurred in 3.7% (n = 50) of patients. Multiple laryngoscopy attempts were associated with an increased risk of hypoxemia (adjusted odds ratio: 1.78, 95% CI: 1.30 to 2.43, P < 0.001). There was no association between multiple laryngoscopy attempts and bradycardia (adjusted odds ratio: 1.23, 95% CI: 0.74 to 2.03, P = 0.255). Conclusions: In a quaternary academic center, healthy infants undergoing routine tracheal intubations had a high incidence of multiple laryngoscopy attempts and associated hypoxemia episodes.
- 1 October 2019
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 131 (4) , 830-839
Open AccessHypoxemia, Bradycardia, and Multiple Laryngoscopy Attempts during Anesthetic Induction in Infants
Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: Background: The infant airway is particularly vulnerable to trauma from repeated laryngoscopy attempts. Complications associated with elective tracheal intubations in anesthetized infants may be underappreciated. We conducted this study of anesthetized infants to determine the incidence of multiple laryngoscopy attempts during routine tracheal intubation and assess the association of laryngoscopy attempts with hypoxemia and bradycardia. Methods: We conducted a retrospective cross-sectional cohort study of anesthetized infants (age less than or equal to 12 months) who underwent direct laryngoscopy for oral endotracheal intubation between January 24, 2015, and August 1, 2016. We excluded patients with a history of difficult intubation and emergency procedures. Our primary outcome was the incidence of hypoxemia or bradycardia during induction of anesthesia. We evaluated the relationship between laryngoscopy attempts and our primary outcome, adjusting for age, weight, American Society of Anesthesiologists status, staffing model, and encounter location. Results: A total of 1,341 patients met our inclusion criteria, and 16% (n = 208) had multiple laryngoscopy attempts. The incidence of hypoxemia was 35% (n = 469) and bradycardia was 8.9% (n = 119). Hypoxemia and bradycardia occurred in 3.7% (n = 50) of patients. Multiple laryngoscopy attempts were associated with an increased risk of hypoxemia (adjusted odds ratio: 1.78, 95% CI: 1.30 to 2.43, P < 0.001). There was no association between multiple laryngoscopy attempts and bradycardia (adjusted odds ratio: 1.23, 95% CI: 0.74 to 2.03, P = 0.255). Conclusions: In a quaternary academic center, healthy infants undergoing routine tracheal intubations had a high incidence of multiple laryngoscopy attempts and associated hypoxemia episodes.