Tugba Sardohan Koseoglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tugba Sardohan Koseoglu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Esengul Kir
Department of Chemistry, Faculty of Engineering and Natural Sciences, Suleyman Demirel University, Isparta, Turkiye
10 shared publications - Bülent Dede
Süleyman Demirel University
4 shared publications - Hasan Koseoglu
Süleyman Demirel Üniversitesi
3 shared publications - Aybüke Durgut
Department of Biomedical Engineering, Faculty of Technology, Isparta University of Applied Sciences, Isparta, Turkiye
2 shared publications Ahmet Aydin
Süleyman Demirel Üniversitesi, Fen Edebiyat Fakültesi, Kimya Bölümü
1 shared publication- Ahmet Aydin
Süleyman Demirel Üniversitesi
1 shared publication
Latest Publications
- Open Access
- 5 June 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (24) , 35672-35686
A Sensitive Electrochemical Sensor Based on Calix[n]arene-Modified PGE for the Determination of Tofacitinib in Human Urine Samples and Pharmaceutical Dosage Forms
Tofacitinib is a potent Janus kinase inhibitor widely used in the treatment of various autoimmune diseases, including rheumatoid arthritis and psoriasis. Monitoring its concentration is vital for therapeutic efficacy and safety. In this study, a novel, rapid, and highly sensitive electrochemical sensing platform was developed for tofacitinib determination using pencil graphite electrodes (PGEs) modified with polypyrrole (PPy) and calix[n]arene derivatives. The modified electrodes were prepared via cyclic voltammetry (CV) by incorporating three different macrocycles: calix[4]arene, calix[6]arene, and calix[8]arene. Surface characterization was performed using Scanning Electron Microscopy (SEM) and SEM-EDS. Under optimized conditions (Britton–Robinson buffer at pH 4.0, 5 polymerization cycles, and 0.005 M modifier concentration), tofacitinib was quantified using differential pulse voltammetry (DPV). The linear calibration ranges were established as 0.10–0.80 ppm for calix[4]arene and calix[6]arene, and 0.10–0.60 ppm for calix[8]arene. The limits of detection (LOD) were found to be 0.0275, 0.0212, and 0.0184 ppm for calix[4], [6], and [8] derivatives, respectively, demonstrating a clear correlation between macrocyclic cavity size and analytical sensitivity. The proposed sensor exhibited excellent selectivity in the presence of common interferents like ascorbic acid, caffeine, and glucose. Furthermore, the practical applicability of the method was validated in pharmaceutical formulations and human urine samples, yielding satisfactory recovery values between 98.0% and 101.5%. This study provides a cost-effective and disposable alternative to sophisticated chromatographic methods for routine clinical analysis.
- 5 June 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (24) , 35672-35686
Open AccessA Sensitive Electrochemical Sensor Based on Calix[n]arene-Modified PGE for the Determination of Tofacitinib in Human Urine Samples and Pharmaceutical Dosage Forms
Tofacitinib is a potent Janus kinase inhibitor widely used in the treatment of various autoimmune diseases, including rheumatoid arthritis and psoriasis. Monitoring its concentration is vital for therapeutic efficacy and safety. In this study, a novel, rapid, and highly sensitive electrochemical sensing platform was developed for tofacitinib determination using pencil graphite electrodes (PGEs) modified with polypyrrole (PPy) and calix[n]arene derivatives. The modified electrodes were prepared via cyclic voltammetry (CV) by incorporating three different macrocycles: calix[4]arene, calix[6]arene, and calix[8]arene. Surface characterization was performed using Scanning Electron Microscopy (SEM) and SEM-EDS. Under optimized conditions (Britton–Robinson buffer at pH 4.0, 5 polymerization cycles, and 0.005 M modifier concentration), tofacitinib was quantified using differential pulse voltammetry (DPV). The linear calibration ranges were established as 0.10–0.80 ppm for calix[4]arene and calix[6]arene, and 0.10–0.60 ppm for calix[8]arene. The limits of detection (LOD) were found to be 0.0275, 0.0212, and 0.0184 ppm for calix[4], [6], and [8] derivatives, respectively, demonstrating a clear correlation between macrocyclic cavity size and analytical sensitivity. The proposed sensor exhibited excellent selectivity in the presence of common interferents like ascorbic acid, caffeine, and glucose. Furthermore, the practical applicability of the method was validated in pharmaceutical formulations and human urine samples, yielding satisfactory recovery values between 98.0% and 101.5%. This study provides a cost-effective and disposable alternative to sophisticated chromatographic methods for routine clinical analysis.
- 24 April 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (11)
Electrochemical Determination of Urea with Modified Pencil Graphite Electrode
Urea is the non-toxic product of nitrogenous organic molecules in human and mammalian metabolism. Low or high urea concentration in metabolism can also be a symptom of various diseases. Therefore, determination of urea concentration in blood and urine is of vital importance, especially in clinical studies. In our study, a polypyrrole-based oxime modified electrode (PGE/PPy/H2KD) was developed in which homodinuclear iminoxime Cu(II) complex compound modified on a new pencil graphite electrode was used as a modifier for the first time. The voltammetric behaviors of the PGE/PPy/H2KD electrode and their differentiation compared to the plain polypyrrole electrode were investigated comparatively. The PGE/PPy/H2KD electrode works with the direct method and has been used for the electrochemical determination of the urea molecule in aqueous solutions. The differentiation of the pencil graphite electrode modified with homodinuclear iminoxime Cu(II) complex-polypyrrole and the increase in its selectivity towards the urea molecule were investigated. The PGE/PPy/H2KD electrode exhibited a linear calibration range of 1.67-15 µM in aqueous solutions (r2=0.9978). The detection limit was found to be 0.71 µM and the electrode achieved a high recovery value in the real sample solution.
- 24 April 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (11)
Electrochemical Determination of Urea with Modified Pencil Graphite Electrode
Urea is the non-toxic product of nitrogenous organic molecules in human and mammalian metabolism. Low or high urea concentration in metabolism can also be a symptom of various diseases. Therefore, determination of urea concentration in blood and urine is of vital importance, especially in clinical studies. In our study, a polypyrrole-based oxime modified electrode (PGE/PPy/H2KD) was developed in which homodinuclear iminoxime Cu(II) complex compound modified on a new pencil graphite electrode was used as a modifier for the first time. The voltammetric behaviors of the PGE/PPy/H2KD electrode and their differentiation compared to the plain polypyrrole electrode were investigated comparatively. The PGE/PPy/H2KD electrode works with the direct method and has been used for the electrochemical determination of the urea molecule in aqueous solutions. The differentiation of the pencil graphite electrode modified with homodinuclear iminoxime Cu(II) complex-polypyrrole and the increase in its selectivity towards the urea molecule were investigated. The PGE/PPy/H2KD electrode exhibited a linear calibration range of 1.67-15 µM in aqueous solutions (r2=0.9978). The detection limit was found to be 0.71 µM and the electrode achieved a high recovery value in the real sample solution.
- Open Access
- 20 April 2026
- Published by SDU Journal of Health Sciences in SDÜ SAĞLIK BİLİMLERİ DERGİSİ
- Vol. 17 (1) , 156-166
Polipirol ile Modifiye Edilmiş Kalem Grafit Elektrot Kullanılarak Sefuroksim Aksetilin Elektrokimyasal Tayini
Sefuroksim aksetil (CEFA), ikinci nesil sefalosporin grubu bir antibiyotik olup, gram pozitif ve gram negatif mikroorganizmalara karşı geniş spektrumlu antimikrobiyal ve antibakteriyel etki göstermektedir. Klinik uygulamalarda üst ve alt solunum yolu enfeksiyonları, idrar yolu enfeksiyonları ile deri ve yumuşak doku enfeksiyonlarının tedavisinde yaygın olarak kullanılmaktadır. Bu çalışmada, sefuroksim aksetilin elektroanalitik tayini amacıyla kalem grafit elektrot (PGE) yüzeyi, pirolün elektropolimerizasyonu yoluyla polipirol (PPy) filmi ile modifiye edilmiştir. Elde edilen modifiye elektrot (PPy/PGE) kullanılarak sefuroksim aksetilin elektroanalitik davranışı ve nicel tayini voltametrik yöntemle incelenmiştir. PGE’nin pirol ile modifikasyonunda dönüşümlü voltametri (CV) tekniği kullanılırken, analitik ölçümler diferansiyel puls voltametrisi (DPV) ile gerçekleştirilmiştir. PPy/PGE elektrot için en uygun elektrot hazırlama koşulları; polimerizasyon döngü sayısı 8, tarama hızı 100 mV/s ve ortam pH’ı 6 olarak belirlenmiştir. Optimize edilen koşullar altında, sulu çözelti ortamında 0,1–1,4 ppm derişim aralığında doğrusal bir kalibrasyon grafiği elde edilmiş olup korelasyon katsayısı (r²) 0,9993 olarak hesaplanmıştır. Yöntemin tespit sınırı 0,0406 ppm olarak bulunmuştur. Ayrıca geliştirilen elektroanalitik yöntemin gerçek numune (idrar numunesi) analizlerinde yüksek geri kazanım değerleri verdiği gözlenmiş olup, PPy/PGE elektrodun sefuroksim aksetilin tayininde güvenilir ve uygulanabilir bir elektrokimyasal sensör olarak kullanılabileceği ortaya konmuştur. Geliştirilen voltametrik yöntem, sefuroksim aksetilin biyolojik örneklerde hızlı, duyarlı ve düşük maliyetli tayini için uygulanabilir bir analitik yaklaşım sunmaktadır.
- 20 April 2026
- Published by SDU Journal of Health Sciences in SDÜ SAĞLIK BİLİMLERİ DERGİSİ
- Vol. 17 (1) , 156-166
Open AccessPolipirol ile Modifiye Edilmiş Kalem Grafit Elektrot Kullanılarak Sefuroksim Aksetilin Elektrokimyasal Tayini
Sefuroksim aksetil (CEFA), ikinci nesil sefalosporin grubu bir antibiyotik olup, gram pozitif ve gram negatif mikroorganizmalara karşı geniş spektrumlu antimikrobiyal ve antibakteriyel etki göstermektedir. Klinik uygulamalarda üst ve alt solunum yolu enfeksiyonları, idrar yolu enfeksiyonları ile deri ve yumuşak doku enfeksiyonlarının tedavisinde yaygın olarak kullanılmaktadır. Bu çalışmada, sefuroksim aksetilin elektroanalitik tayini amacıyla kalem grafit elektrot (PGE) yüzeyi, pirolün elektropolimerizasyonu yoluyla polipirol (PPy) filmi ile modifiye edilmiştir. Elde edilen modifiye elektrot (PPy/PGE) kullanılarak sefuroksim aksetilin elektroanalitik davranışı ve nicel tayini voltametrik yöntemle incelenmiştir. PGE’nin pirol ile modifikasyonunda dönüşümlü voltametri (CV) tekniği kullanılırken, analitik ölçümler diferansiyel puls voltametrisi (DPV) ile gerçekleştirilmiştir. PPy/PGE elektrot için en uygun elektrot hazırlama koşulları; polimerizasyon döngü sayısı 8, tarama hızı 100 mV/s ve ortam pH’ı 6 olarak belirlenmiştir. Optimize edilen koşullar altında, sulu çözelti ortamında 0,1–1,4 ppm derişim aralığında doğrusal bir kalibrasyon grafiği elde edilmiş olup korelasyon katsayısı (r²) 0,9993 olarak hesaplanmıştır. Yöntemin tespit sınırı 0,0406 ppm olarak bulunmuştur. Ayrıca geliştirilen elektroanalitik yöntemin gerçek numune (idrar numunesi) analizlerinde yüksek geri kazanım değerleri verdiği gözlenmiş olup, PPy/PGE elektrodun sefuroksim aksetilin tayininde güvenilir ve uygulanabilir bir elektrokimyasal sensör olarak kullanılabileceği ortaya konmuştur. Geliştirilen voltametrik yöntem, sefuroksim aksetilin biyolojik örneklerde hızlı, duyarlı ve düşük maliyetli tayini için uygulanabilir bir analitik yaklaşım sunmaktadır.
- 30 January 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (5)
An Imidazole‐Functionalized Boron‐Dipyrromethene Derivative for Spectrophotometric Fluorescence Detection of Fe 2+ and Electrochemical Sensing of Cu 2+
A novel Boron‐dipyrromethene derivative (BODIPY‐3) was synthesized by functionalizing the meso position of the BODIPY core with an imidazole‐containing moiety and evaluated as both a spectrophotometric and electrochemical sensor. The spectrophotometric sensing behavior of BODIPY‐3 toward Fe 2+ , Fe 3+ , and Cu 2+ ions was investigated. Fluorescence spectroscopy revealed a highly selective response to Fe 2+ , a moderate affinity for Fe 3+ , and a lower sensitivity toward Cu 2+ . Based on calibration studies, the limits of detection (LOD) and quantification (LOQ) were determined as 28.665 µM and 95.551 µM for Fe 2+ , 30.999 µM and 103.331 µM for Fe 3+ , and 26.216 µM and 87.386 µM for Cu 2+ , respectively, with low relative standard deviation values, indicating good repeatability. For electrochemical sensing, pencil graphite electrodes were modified with polypyrrole and BODIPY‐3 (BODIPY‐3/PPy/PGE) via cyclic voltammetry. Differential pulse voltammetry enabled sensitive Cu 2+ detection, yielding LOD and LOQ values of 0.069 ppm and 0.231 ppm, respectively. The applicability of the developed sensor was demonstrated using real water samples, with recovery values ranging from 94.67% to 102.86%. Overall, the results highlight the potential of imidazole‐functionalized BODIPY‐based systems for selective metal ion sensing, with demonstrated electrochemical sensing of Cu 2+ and spectrophotometric detection of Fe 2+ , suggesting their applicability in environmental monitoring.
- 30 January 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (5)
An Imidazole‐Functionalized Boron‐Dipyrromethene Derivative for Spectrophotometric Fluorescence Detection of Fe 2+ and Electrochemical Sensing of Cu 2+
A novel Boron‐dipyrromethene derivative (BODIPY‐3) was synthesized by functionalizing the meso position of the BODIPY core with an imidazole‐containing moiety and evaluated as both a spectrophotometric and electrochemical sensor. The spectrophotometric sensing behavior of BODIPY‐3 toward Fe 2+ , Fe 3+ , and Cu 2+ ions was investigated. Fluorescence spectroscopy revealed a highly selective response to Fe 2+ , a moderate affinity for Fe 3+ , and a lower sensitivity toward Cu 2+ . Based on calibration studies, the limits of detection (LOD) and quantification (LOQ) were determined as 28.665 µM and 95.551 µM for Fe 2+ , 30.999 µM and 103.331 µM for Fe 3+ , and 26.216 µM and 87.386 µM for Cu 2+ , respectively, with low relative standard deviation values, indicating good repeatability. For electrochemical sensing, pencil graphite electrodes were modified with polypyrrole and BODIPY‐3 (BODIPY‐3/PPy/PGE) via cyclic voltammetry. Differential pulse voltammetry enabled sensitive Cu 2+ detection, yielding LOD and LOQ values of 0.069 ppm and 0.231 ppm, respectively. The applicability of the developed sensor was demonstrated using real water samples, with recovery values ranging from 94.67% to 102.86%. Overall, the results highlight the potential of imidazole‐functionalized BODIPY‐based systems for selective metal ion sensing, with demonstrated electrochemical sensing of Cu 2+ and spectrophotometric detection of Fe 2+ , suggesting their applicability in environmental monitoring.
- 23 January 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (4)
Furfurylamine‐Bonded Keto‐Oxime Modified Electrode for Determination of Nickel(II) Ion in Water
In this study, a novel modified electrode was developed by incorporating furfurylamine keto‐oxime (FKO) as a functional compound for the sensitive electrochemical determination of Ni(II) ions. PPy and FKO–PPy modified electrodes were prepared using the cyclic voltammetry (CV) technique, while the determination of Ni(II) was carried out by differential pulse voltammetry employing PGE, PPy, and FKO–PPy electrodes. The experimental parameters influencing the electrode response, including the number of electropolymerization cycles, scan rate, and FKO concentration, were systematically optimized. Comparative DPV responses demonstrated that the FKO–PPy electrode exhibited the highest selectivity toward Ni(II) ions. A linear response was obtained in the Ni(II) concentration range of 2–10 ppm with a correlation coefficient of 0.9995, and the limit of detection was calculated as 0.378 ppm (S/N = 3). The applicability of the FKO–PPy electrode was further evaluated using deionized water, tap water, and wastewater samples, with the highest recovery values obtained in deionized water. In addition, interference studies indicated that the presence of common cations did not significantly affect the Ni(II) response of the FKO–PPy electrode.
- 23 January 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (4)
Furfurylamine‐Bonded Keto‐Oxime Modified Electrode for Determination of Nickel(II) Ion in Water
In this study, a novel modified electrode was developed by incorporating furfurylamine keto‐oxime (FKO) as a functional compound for the sensitive electrochemical determination of Ni(II) ions. PPy and FKO–PPy modified electrodes were prepared using the cyclic voltammetry (CV) technique, while the determination of Ni(II) was carried out by differential pulse voltammetry employing PGE, PPy, and FKO–PPy electrodes. The experimental parameters influencing the electrode response, including the number of electropolymerization cycles, scan rate, and FKO concentration, were systematically optimized. Comparative DPV responses demonstrated that the FKO–PPy electrode exhibited the highest selectivity toward Ni(II) ions. A linear response was obtained in the Ni(II) concentration range of 2–10 ppm with a correlation coefficient of 0.9995, and the limit of detection was calculated as 0.378 ppm (S/N = 3). The applicability of the FKO–PPy electrode was further evaluated using deionized water, tap water, and wastewater samples, with the highest recovery values obtained in deionized water. In addition, interference studies indicated that the presence of common cations did not significantly affect the Ni(II) response of the FKO–PPy electrode.
- Open Access
- 25 December 2025
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 29 (3) , 538-548
Ditiyofosfat Türevleri ile Modifiye edilen Kalem Grafit Elektrotlarında Nikel(II)’ nin Voltametrik Tayini
Bu çalışmada, ditiyofosfat türevlerinin iki modifiyeri olan amonyum diizobutilditiyofosfat (L1) ve amonyum diizopropilditiyofosfat (L2), Ni(II)'nin elektrokimyasal tayini için polipirol (PPy) bazlı kalem grafit elektrotları (PGE) hazırlamak amacıyla modifiyer olarak kullanılmıştır. Ditiyofosfatla modifiye edilmiş kalem grafit elektrotlar PGE/PPy/L1 ve PGE/PPy/L2 olarak adlandırılmıştır. Döngü sayısı, tarama hızı, pH ve ditiyofosfat konsantrasyonu gibi tüm parametreler optimize edilmiştir. Optimizasyondan sonra, PGE/PPy/L1 ve PGE/PPy/L2 elektrotları diferansiyel puls voltametrisi (DPV) ile Ni(II) iyonlarının tayini için kullanılmıştır. PGE/PPy/L1 ve PGE/PPy/L2 elektrotları sırasıyla 4-10 mg/L (r2= 0.9944) ve 2-9 mg/L (r2= 0.9924) arasında doğrusal bir cevap göstermiştir. PGE/PPy/L1 ve PGE/PPy/L2 elektrotlarının tayin sınırları da sırasıyla 0.87 mg/L ve 0.96 mg/L (S/N = 3) olarak bulunmuştur. Çeşitli katyonların Ni(II) tayini üzerindeki girişim etkileri de ayrıca incelenmiştir. Son olarak, hazırlanan PGE/PPy/L1 ve PGE/PPy/L2 elektrotları farklı su örneklerindeki Ni(II) tayini için kullanılmıştır.
- 25 December 2025
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 29 (3) , 538-548
Open AccessDitiyofosfat Türevleri ile Modifiye edilen Kalem Grafit Elektrotlarında Nikel(II)’ nin Voltametrik Tayini
Bu çalışmada, ditiyofosfat türevlerinin iki modifiyeri olan amonyum diizobutilditiyofosfat (L1) ve amonyum diizopropilditiyofosfat (L2), Ni(II)'nin elektrokimyasal tayini için polipirol (PPy) bazlı kalem grafit elektrotları (PGE) hazırlamak amacıyla modifiyer olarak kullanılmıştır. Ditiyofosfatla modifiye edilmiş kalem grafit elektrotlar PGE/PPy/L1 ve PGE/PPy/L2 olarak adlandırılmıştır. Döngü sayısı, tarama hızı, pH ve ditiyofosfat konsantrasyonu gibi tüm parametreler optimize edilmiştir. Optimizasyondan sonra, PGE/PPy/L1 ve PGE/PPy/L2 elektrotları diferansiyel puls voltametrisi (DPV) ile Ni(II) iyonlarının tayini için kullanılmıştır. PGE/PPy/L1 ve PGE/PPy/L2 elektrotları sırasıyla 4-10 mg/L (r2= 0.9944) ve 2-9 mg/L (r2= 0.9924) arasında doğrusal bir cevap göstermiştir. PGE/PPy/L1 ve PGE/PPy/L2 elektrotlarının tayin sınırları da sırasıyla 0.87 mg/L ve 0.96 mg/L (S/N = 3) olarak bulunmuştur. Çeşitli katyonların Ni(II) tayini üzerindeki girişim etkileri de ayrıca incelenmiştir. Son olarak, hazırlanan PGE/PPy/L1 ve PGE/PPy/L2 elektrotları farklı su örneklerindeki Ni(II) tayini için kullanılmıştır.
- Open Access
- 25 August 2025
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 29 (2) , 278-303
Nanohidroksiapatit Katkılı PMMA, PS ve PVA Nanokompozit Membranların Hazırlanması ve Karakterizasyonu
Bu çalışmada, membran teknolojisi ile biyomalzeme amaçlı kullanılabilecek yeni tür polimerik nanokompozit membranların geliştirilmesi amaçlanmıştır. Çalışmada, ilk olarak yaş kimyasal yöntemi ile nano boyutlarda hidroksiapatit (nHA) sentezi yapılmıştır. İkinci aşamada ise, farklı yüzdelik oranlarda polimetil metakrilat (PMMA), polisülfon (PS) ve polivinil alkol (PVA) polimerleri ve farklı yüzdelik oranlarda (kütlece %1-7) nHA karıştırılarak faz inversiyon yöntemi ile nanokompozit membranlar hazırlanmıştır. Membranların hazırlanmasında çapraz bağlayıcı olarak polivinilpirolidon (PVP) kullanılmıştır. Polimerik nanokompozit membranların morfolojik yapıları taramalı elektron mikroskobu (SEM) ve atomik kuvvet mikroskobu (AFM) cihazları kullanılarak, malzemelerin kristalografik özelliklerinin ve içerdikleri fazların belirlenmesi X-ışını kırınım (XRD) cihazı kullanılarak yapıldı. Ayrıca, SEM-EDS ve Fourier dönüşümlü kızılötesi spektroskopisi (FTIR) ile yapı analizleri gerçekleştirilmiştir. Hazırlanan membranların içeriğindeki hidroksiapatitin, kemik bileşimine benzerliği nedeniyle hazırlanan polimerik nanokompozit membranlara gerekli testler yapıldıktan sonra ortopedi alanında çok çeşitli uygulamalarda kullanılabileceği değerlendirilmektir.
- 25 August 2025
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 29 (2) , 278-303
Open AccessNanohidroksiapatit Katkılı PMMA, PS ve PVA Nanokompozit Membranların Hazırlanması ve Karakterizasyonu
Bu çalışmada, membran teknolojisi ile biyomalzeme amaçlı kullanılabilecek yeni tür polimerik nanokompozit membranların geliştirilmesi amaçlanmıştır. Çalışmada, ilk olarak yaş kimyasal yöntemi ile nano boyutlarda hidroksiapatit (nHA) sentezi yapılmıştır. İkinci aşamada ise, farklı yüzdelik oranlarda polimetil metakrilat (PMMA), polisülfon (PS) ve polivinil alkol (PVA) polimerleri ve farklı yüzdelik oranlarda (kütlece %1-7) nHA karıştırılarak faz inversiyon yöntemi ile nanokompozit membranlar hazırlanmıştır. Membranların hazırlanmasında çapraz bağlayıcı olarak polivinilpirolidon (PVP) kullanılmıştır. Polimerik nanokompozit membranların morfolojik yapıları taramalı elektron mikroskobu (SEM) ve atomik kuvvet mikroskobu (AFM) cihazları kullanılarak, malzemelerin kristalografik özelliklerinin ve içerdikleri fazların belirlenmesi X-ışını kırınım (XRD) cihazı kullanılarak yapıldı. Ayrıca, SEM-EDS ve Fourier dönüşümlü kızılötesi spektroskopisi (FTIR) ile yapı analizleri gerçekleştirilmiştir. Hazırlanan membranların içeriğindeki hidroksiapatitin, kemik bileşimine benzerliği nedeniyle hazırlanan polimerik nanokompozit membranlara gerekli testler yapıldıktan sonra ortopedi alanında çok çeşitli uygulamalarda kullanılabileceği değerlendirilmektir.
- 1 February 2021
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 19 (1) , 379-390
Separation of Cu2+ from membrane concentrate by SiO2/3-Aminopropyltriethoxysilane-coated ceramic membrane
- 1 February 2021
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 19 (1) , 379-390
Separation of Cu2+ from membrane concentrate by SiO2/3-Aminopropyltriethoxysilane-coated ceramic membrane
- 25 December 2020
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 24 (3) , 659-668
Nanotel Yapılı Kalem Grafit Elektrotlar Kullanılarak Prometazinin Voltametrik Tayini
Çalışmada, prometazin tayini için kalem grafit elektrot (KGE) temelli polimerik nanotel yapılı elektrotlar (KGE-AY-NT1 ve KGE-AY-NT2) hazırlanmıştır. Döngü sayısı, tarama hızı ve ortam pH değeri gibi parametreler optimize edilmiştir. Yapılan deneyler sonucunda, optimum döngü sayısı 4, tarama hızı 100 mV/s ve ortamın pH değeri 4 olarak belirlenmiştir. Elektrotlar dönüşümlü voltametri (CV) yöntemi ile hazırlanmıştır. Elektrotların prometazin tayini üzerindeki performansı ise diferansiyel puls voltametrisi (DPV) yöntemi ile araştırılmıştır. Doğrusal çalışma aralığına 0.05-0.3 mM prometazin derişim aralığında (KGE-AY-NT1; R2=0.9995 ve KGE-AY-NT2; R2=0.9996) ulaşılmıştır. KGE-AY-NT1 ve KGE-AY-NT2 elektrotlar için gözlenebilme sınırları (LOD) sırasıyla 0.015 mM ve 0.012 mM olarak bulunmuştur (S/N=3). Girişim etkisi deney sonuçları, KGE-AY-NT1 ve KGE-AY-NT2 elektrotlarının prometazine karşı seçicilik ve hassasiyetinin, girişim yapan türlerin varlığından önemli ölçüde etkilenmediğini göstermiştir. Geliştirilen elektrotlar, standart ekleme yöntemi ile idrar numunesine katkılandırılmış prometazinin tayininde uygulanmış ve yöntemin geri kazanım değerlerinin %100’e yakın olduğu belirlenmiştir.
- 25 December 2020
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 24 (3) , 659-668
Nanotel Yapılı Kalem Grafit Elektrotlar Kullanılarak Prometazinin Voltametrik Tayini
Çalışmada, prometazin tayini için kalem grafit elektrot (KGE) temelli polimerik nanotel yapılı elektrotlar (KGE-AY-NT1 ve KGE-AY-NT2) hazırlanmıştır. Döngü sayısı, tarama hızı ve ortam pH değeri gibi parametreler optimize edilmiştir. Yapılan deneyler sonucunda, optimum döngü sayısı 4, tarama hızı 100 mV/s ve ortamın pH değeri 4 olarak belirlenmiştir. Elektrotlar dönüşümlü voltametri (CV) yöntemi ile hazırlanmıştır. Elektrotların prometazin tayini üzerindeki performansı ise diferansiyel puls voltametrisi (DPV) yöntemi ile araştırılmıştır. Doğrusal çalışma aralığına 0.05-0.3 mM prometazin derişim aralığında (KGE-AY-NT1; R2=0.9995 ve KGE-AY-NT2; R2=0.9996) ulaşılmıştır. KGE-AY-NT1 ve KGE-AY-NT2 elektrotlar için gözlenebilme sınırları (LOD) sırasıyla 0.015 mM ve 0.012 mM olarak bulunmuştur (S/N=3). Girişim etkisi deney sonuçları, KGE-AY-NT1 ve KGE-AY-NT2 elektrotlarının prometazine karşı seçicilik ve hassasiyetinin, girişim yapan türlerin varlığından önemli ölçüde etkilenmediğini göstermiştir. Geliştirilen elektrotlar, standart ekleme yöntemi ile idrar numunesine katkılandırılmış prometazinin tayininde uygulanmış ve yöntemin geri kazanım değerlerinin %100’e yakın olduğu belirlenmiştir.
- 31 August 2020
- Published by Erzincan Universitesi Fen Bilimleri Ensitusu Dergisi in Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 13 (2) , 580-591
Schiff Bazı Esaslı Destekli Sıvı Membranlar ile Sulu Çözeltiden Cu(II) İyonlarının Donnan Diyaliz Metodu ile Ayrılması
Bu çalışmada, daha önceden sentezlenmiş olan 4-(4-{4-[1-metil-3-oksobutilidenamino] fenil} fenilimino)-2-pentanon (BAA) schiff bazı kullanılarak farklı destek tabakaları ve farklı çözücüler ile destekli sıvı membranlar hazırlanmıştır. Donnan diyaliz yöntemi ile sulu ortamda belli bir miktarı aşması durumunda zararlı olabilecek Cu(II) katyonunun seçimli olarak ayrılması ve taşınması özellikleri bu yeni hazırlanan membranlar kullanılarak incelenmiştir. Bu membranlar kullanılarak konsantrasyon etkisinin Cu(II) iyonunun taşınmasındaki etkisi incelenmiş ve Cu(II) için akış (J) değerleri hesaplanmıştır. Metal iyonlarının akışı, konsantrasyon artışı ile artmıştır. Hazırlanan bu yeni tip membranların karakterizasyon işlemleri SEM, AFM ve FTIR ile yapılmıştır. Farklı membranlarda farklı akış olması membran yapılarının farklılığı ile açıklanmıştır. Hazırlanan membranların kalınlıkları da belirlenmiştir. Ayrıca, membranların potansiyel ölçüm deneyleri de incelenmiştir.
- 31 August 2020
- Published by Erzincan Universitesi Fen Bilimleri Ensitusu Dergisi in Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 13 (2) , 580-591
Schiff Bazı Esaslı Destekli Sıvı Membranlar ile Sulu Çözeltiden Cu(II) İyonlarının Donnan Diyaliz Metodu ile Ayrılması
Bu çalışmada, daha önceden sentezlenmiş olan 4-(4-{4-[1-metil-3-oksobutilidenamino] fenil} fenilimino)-2-pentanon (BAA) schiff bazı kullanılarak farklı destek tabakaları ve farklı çözücüler ile destekli sıvı membranlar hazırlanmıştır. Donnan diyaliz yöntemi ile sulu ortamda belli bir miktarı aşması durumunda zararlı olabilecek Cu(II) katyonunun seçimli olarak ayrılması ve taşınması özellikleri bu yeni hazırlanan membranlar kullanılarak incelenmiştir. Bu membranlar kullanılarak konsantrasyon etkisinin Cu(II) iyonunun taşınmasındaki etkisi incelenmiş ve Cu(II) için akış (J) değerleri hesaplanmıştır. Metal iyonlarının akışı, konsantrasyon artışı ile artmıştır. Hazırlanan bu yeni tip membranların karakterizasyon işlemleri SEM, AFM ve FTIR ile yapılmıştır. Farklı membranlarda farklı akış olması membran yapılarının farklılığı ile açıklanmıştır. Hazırlanan membranların kalınlıkları da belirlenmiştir. Ayrıca, membranların potansiyel ölçüm deneyleri de incelenmiştir.