Pavel Mec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pavel Mec has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Jan Nedoma
Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB—Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic
8 shared publications - Marcel Fajkus
Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSBTechnical University of Ostrava, Ostrava, Czech Republic
8 shared publications Tereza Murínová
VSB – Technical University of Ostrava
7 shared publications- Jana Boháčová
Faculty of Civil Engineering VSB-Technical University of Ostrava L. Podeste 1875 Ostrava-Poruba 70800 Czech Republic
6 shared publications - Jana Daňková
VSB – Technical University of Ostrava
6 shared publications Martin Novák
6 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 2 (1)
Comprehensive Diagnostics of an Aerated Concrete Structure: A Case Study of Crack Development
The paper presents a case study of comprehensive diagnostics of a single - story public facility building constructed from aerated concrete blocks, in which significant structural defects in the form of wall cracking and deformation of load - bearing elements were identified. The research aimed to determine the primary causes of these defects and to assess the interaction among the structural components of the building. The diagnostic investigation combined destructive and non - destructive methods, including visual inspection, destructive prospect holes, core drilling, crack mapping, evaluation of roof structure based on determination of mechanical properties using Pilodyn, moisture measurement by resistivity hygrometer, and detailed analysis of structural details. The results showed that the defects were primarily caused by a combination of inadequate roof truss design, insufficient compliance with construction procedures, and differential deformation of the materials used. A significant contribution also resulted from the rigid connection between steel structure of the canopy and the aerated concrete masonry without sufficient allowance for thermal dilation, leading to tensile stresses and subsequent crack propagation. The study confirmed the low resistance of aerated concrete masonry to tensile stresses and deformations induced by adjacent structural elements. In addition, the diagnostics revealed deficiencies in material quality and locally inappropriate construction detailing. The case study highlights the importance of a comprehensive diagnostic approach in the assessment of aerated concrete structures and in the identification of defects that are typical of this type of building. Critical areas were found particularly at the interface between the external load - bearing masonry and the foundation structure, especially near door and window openings, as well as in zones affected by the interaction between the masonry, roof truss elements, horizontal structures, and attached extensions.
- 1 November 2026
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 2 (1)
Open AccessComprehensive Diagnostics of an Aerated Concrete Structure: A Case Study of Crack Development
The paper presents a case study of comprehensive diagnostics of a single - story public facility building constructed from aerated concrete blocks, in which significant structural defects in the form of wall cracking and deformation of load - bearing elements were identified. The research aimed to determine the primary causes of these defects and to assess the interaction among the structural components of the building. The diagnostic investigation combined destructive and non - destructive methods, including visual inspection, destructive prospect holes, core drilling, crack mapping, evaluation of roof structure based on determination of mechanical properties using Pilodyn, moisture measurement by resistivity hygrometer, and detailed analysis of structural details. The results showed that the defects were primarily caused by a combination of inadequate roof truss design, insufficient compliance with construction procedures, and differential deformation of the materials used. A significant contribution also resulted from the rigid connection between steel structure of the canopy and the aerated concrete masonry without sufficient allowance for thermal dilation, leading to tensile stresses and subsequent crack propagation. The study confirmed the low resistance of aerated concrete masonry to tensile stresses and deformations induced by adjacent structural elements. In addition, the diagnostics revealed deficiencies in material quality and locally inappropriate construction detailing. The case study highlights the importance of a comprehensive diagnostic approach in the assessment of aerated concrete structures and in the identification of defects that are typical of this type of building. Critical areas were found particularly at the interface between the external load - bearing masonry and the foundation structure, especially near door and window openings, as well as in zones affected by the interaction between the masonry, roof truss elements, horizontal structures, and attached extensions.
- Open Access
- 3 December 2025
- Published by Editorial CSIC in Materiales de Construcción
- Vol. 75 (360) , e396
Roman cement mortar prepared by a multi-stage mixing process
Roman cement is the predecessor to modern Portland cement. Nowadays, it is a very promising product with lower CO2 emissions, frequently used to restore historical objects. However, there are still many practical problems as a setting that can be affected in several ways. One possibility is the multistage mixing of fresh mortar, a practical historical method that has not yet been scientifically investigated. This article presents an experimental study investigating the effect of multistage mixing on the properties of fresh and hardened mortar. The properties and structure of the mortar were compared with a reference mortar (retardened by citric acid). Multistage mixing affects fresh mortars with optimal consistency and a workability time of 120 minutes. The influence of mixing on the hydration process and structural formation is characterized by isothermal calorimetry and SEM. Comparison of reference and modified mixing mortars exhibits differences in hydration process, structure, and initial strength, but no significant effect at 90 days strength.
- 3 December 2025
- Published by Editorial CSIC in Materiales de Construcción
- Vol. 75 (360) , e396
Open AccessRoman cement mortar prepared by a multi-stage mixing process
Roman cement is the predecessor to modern Portland cement. Nowadays, it is a very promising product with lower CO2 emissions, frequently used to restore historical objects. However, there are still many practical problems as a setting that can be affected in several ways. One possibility is the multistage mixing of fresh mortar, a practical historical method that has not yet been scientifically investigated. This article presents an experimental study investigating the effect of multistage mixing on the properties of fresh and hardened mortar. The properties and structure of the mortar were compared with a reference mortar (retardened by citric acid). Multistage mixing affects fresh mortars with optimal consistency and a workability time of 120 minutes. The influence of mixing on the hydration process and structural formation is characterized by isothermal calorimetry and SEM. Comparison of reference and modified mixing mortars exhibits differences in hydration process, structure, and initial strength, but no significant effect at 90 days strength.
- Open Access
- 9 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4796
Portable Optical Fiber Bragg Grating Sensor for Monitoring Traffic Density
The paper examines the development of a portable sensor strip with fiber optic Bragg grating for monitoring urban traffic density up to 80 kph. It contains a 2.5-m-long and a 2-cm-high sensor created from a combination of silicone addition rubber (bicomponent addition silicone rubber) and Bragg grating placed inside a carbon tube. The design of the portable sensor permits traffic density and cars crossings to be monitored and detected in a single lane. The functionality of the sensor was verified in real traffic; the results of this study are based on the detection of 1518 vehicles of different types and sizes. According to the measurements, the sensor is characterized by a high detection rate of 98.946%.
- 9 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4796
Open AccessPortable Optical Fiber Bragg Grating Sensor for Monitoring Traffic Density
The paper examines the development of a portable sensor strip with fiber optic Bragg grating for monitoring urban traffic density up to 80 kph. It contains a 2.5-m-long and a 2-cm-high sensor created from a combination of silicone addition rubber (bicomponent addition silicone rubber) and Bragg grating placed inside a carbon tube. The design of the portable sensor permits traffic density and cars crossings to be monitored and detected in a single lane. The functionality of the sensor was verified in real traffic; the results of this study are based on the detection of 1518 vehicles of different types and sizes. According to the measurements, the sensor is characterized by a high detection rate of 98.946%.
- 12 December 2018
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 12 (2018) , 2611-2615
SIMULATION MODEL OF POLYCARBONATE MATERIAL FOR ADDITIVE TECHNOLOGY FDM
- 12 December 2018
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 12 (2018) , 2611-2615
SIMULATION MODEL OF POLYCARBONATE MATERIAL FOR ADDITIVE TECHNOLOGY FDM
- 6 November 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 17, 21
Analysis of using PDMS polymer as the sensors of the pressure or weight
- 6 November 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 17, 21
Analysis of using PDMS polymer as the sensors of the pressure or weight
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 17, 28
Monitoring of the structural loads of tunnels using a distributed optical system BOTDR
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 17, 28
Monitoring of the structural loads of tunnels using a distributed optical system BOTDR
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
Fiber optic sensor for monitoring a density of road traffic
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
Fiber optic sensor for monitoring a density of road traffic
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 38
Monitoring system of hydraulic lifting device based on the fiber optic sensors
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 38
Monitoring system of hydraulic lifting device based on the fiber optic sensors
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10142
Bragg grating sensors for the monitoring load of production press machines
- 26 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10142
Bragg grating sensors for the monitoring load of production press machines