Shinya Homma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shinya Homma has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Yasutomo Yajima
Department of Oral and Maxillofacial Implantology, Tokyo Dental College
2 shared publications- Hirofumi Kido
Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, 2-15-1 Tamura, Sawara-ku, Fukuoka-City Fukuoka, 814-0175, Japan
1 shared publication Hotaka Sasaki
Department of Oral and Maxillofacial Implantology, Tokyo Dental College
1 shared publication- Kenzou Morinaga
Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, 2-15-1 Tamura, Sawara-ku, Fukuoka-City Fukuoka, 814-0175, Japan
1 shared publication - Masao Yoshinari
Oral Health Science Center, Tokyo Dental College
1 shared publication - Satoru Yokoue
Center for Oral Diseases, Fukuoka Dental College, 3-2-1 Hakataekimae, Hakata-ku, Fukuoka City Fukuoka, 812-0011, Japan
1 shared publication
Latest Publications
- Open Access
- 28 March 2019
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 38 (2) , 250-256
Wear properties of esthetic dental materials against translucent zirconia
To clarify the influence of translucent tetragonal zirconia polycrystals (TZP) on wear properties of esthetic dental materials, twobody wear test was performed using translucent TZP as abrader specimen, and bovine tooth enamel (BTE), two resin composites including hybrid filler (CRH) and nano filler (CRN), two glass ceramics including leucite reinforced feldspar porcelain (POR) and lithium disilicate (LDC), or translucent TZP as substrate specimen. After the wear test, wear volume were determined from substrate specimen and surface roughness were measured from abrader specimen. In addition, Vickers hardness was measured and surface morphologies were observed after wear test using a scanning electron microscope. The wear volume of the esthetic dental material against translucent TZP was greater in glass ceramics (POR, LDC), smaller in resin composite (CRH, CRN) and BTE, and no wear in translucent TZP. Microstructures of the esthetic dental material may play a crucial role for wear behavior against translucent TZP.
- 28 March 2019
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 38 (2) , 250-256
Open AccessWear properties of esthetic dental materials against translucent zirconia
To clarify the influence of translucent tetragonal zirconia polycrystals (TZP) on wear properties of esthetic dental materials, twobody wear test was performed using translucent TZP as abrader specimen, and bovine tooth enamel (BTE), two resin composites including hybrid filler (CRH) and nano filler (CRN), two glass ceramics including leucite reinforced feldspar porcelain (POR) and lithium disilicate (LDC), or translucent TZP as substrate specimen. After the wear test, wear volume were determined from substrate specimen and surface roughness were measured from abrader specimen. In addition, Vickers hardness was measured and surface morphologies were observed after wear test using a scanning electron microscope. The wear volume of the esthetic dental material against translucent TZP was greater in glass ceramics (POR, LDC), smaller in resin composite (CRH, CRN) and BTE, and no wear in translucent TZP. Microstructures of the esthetic dental material may play a crucial role for wear behavior against translucent TZP.
- Open Access
- 29 March 2018
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 4 (1) , 10
Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region
A current implant body surface was treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseointegration and shortening the treatment period. Various reports have examined the healing period with the use of these implant bodies, but a consensus opinion has not yet been obtained. The purpose of this study is to evaluate the relationship between insertion torque (IT) and implant stability quotient (ISQ) at implant treatment using the current rough-surfaced implant. We evaluated the implant treatment sites with ISQ values, IT values, and voxel values. Participants in this study comprised 26 patients (10 males, 16 females; mean age, 55.5 years) who received posterior region dental implants at Tokyo Dental College Hospital or Fukuoka Dental College Hospital. For all participants, pretreatment computed tomography and determination of bone quality from voxel values were performed. Thirty-two implant bodies were inserted into the posterior region, and insertion torque was measured. ISQ was also measured at 0, 2, 4, 6, 8, and 12 weeks postoperatively. Eight implant bodies in the maxilla and 24 in the mandible were inserted. All ISQ values increased, exceeding 60 by 6 weeks postoperatively. For insertion torque < 30 N cm, ISQ increased significantly after 8 weeks. For ≥ 30 N cm, the ratio at which high ISQ values appeared increased significantly after 6 weeks. Compared with the treatment area with insertion torque < 40 N cm, the treatment area ≥ 40 N cm showed a significantly higher voxel value. No significant relationship was found between the insertion torque value and the ISQ value. Also, it was suggested that the ISQ value was considered to be an important indicator for observing the treatment state of the implant.
- 29 March 2018
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 4 (1) , 10
Open AccessProspective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region
A current implant body surface was treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseointegration and shortening the treatment period. Various reports have examined the healing period with the use of these implant bodies, but a consensus opinion has not yet been obtained. The purpose of this study is to evaluate the relationship between insertion torque (IT) and implant stability quotient (ISQ) at implant treatment using the current rough-surfaced implant. We evaluated the implant treatment sites with ISQ values, IT values, and voxel values. Participants in this study comprised 26 patients (10 males, 16 females; mean age, 55.5 years) who received posterior region dental implants at Tokyo Dental College Hospital or Fukuoka Dental College Hospital. For all participants, pretreatment computed tomography and determination of bone quality from voxel values were performed. Thirty-two implant bodies were inserted into the posterior region, and insertion torque was measured. ISQ was also measured at 0, 2, 4, 6, 8, and 12 weeks postoperatively. Eight implant bodies in the maxilla and 24 in the mandible were inserted. All ISQ values increased, exceeding 60 by 6 weeks postoperatively. For insertion torque < 30 N cm, ISQ increased significantly after 8 weeks. For ≥ 30 N cm, the ratio at which high ISQ values appeared increased significantly after 6 weeks. Compared with the treatment area with insertion torque < 40 N cm, the treatment area ≥ 40 N cm showed a significantly higher voxel value. No significant relationship was found between the insertion torque value and the ISQ value. Also, it was suggested that the ISQ value was considered to be an important indicator for observing the treatment state of the implant.
- Open Access
- 1 January 2015
- Published by Tokyo Dental College in The Bulletin of Tokyo Dental College
- Vol. 56 (2) , 73-83
Current State of Undergraduate Education in Oral Implantology in Japan
An anonymous questionnaire-based survey was used to determine the current state of and issues involved in undergraduate education in oral implantology at Tokyo Dental College. The participants comprised 139 students who had received lectures on and practical training in oral implantology in 2013. The results indicate that the overall level of student comprehension was high for both lectures and practical training content; the level of difficulty was appropriate for practical training, but the amount of practice time given requires reconsideration. Over 80% of the students gave positive responses in their overall evaluation of lectures and practical training, and the number of students who had an interest in oral implantology after finishing the course and who wanted to be involved in oral implantology as dentists increased. These results indicate that this undergraduate education program is effective in improving understanding of oral implantology. Improvement is required, however, in lecture methodology and practical training content. It is also suggested that the curriculum should be evaluated by students regularly and that the courses be subject to updating as required.
- 1 January 2015
- Published by Tokyo Dental College in The Bulletin of Tokyo Dental College
- Vol. 56 (2) , 73-83
Open AccessCurrent State of Undergraduate Education in Oral Implantology in Japan
An anonymous questionnaire-based survey was used to determine the current state of and issues involved in undergraduate education in oral implantology at Tokyo Dental College. The participants comprised 139 students who had received lectures on and practical training in oral implantology in 2013. The results indicate that the overall level of student comprehension was high for both lectures and practical training content; the level of difficulty was appropriate for practical training, but the amount of practice time given requires reconsideration. Over 80% of the students gave positive responses in their overall evaluation of lectures and practical training, and the number of students who had an interest in oral implantology after finishing the course and who wanted to be involved in oral implantology as dentists increased. These results indicate that this undergraduate education program is effective in improving understanding of oral implantology. Improvement is required, however, in lecture methodology and practical training content. It is also suggested that the curriculum should be evaluated by students regularly and that the courses be subject to updating as required.