DPDavid C. Pace

David C. Pace

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David C. Pace has a total of 165 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Erratum: “DIII-D's role as national user facility in enabling the commercialization of fusion energy” [Phys. Plasmas 30 , 120603 (2023)]

    by R. J. Buttery, T. Abrams, L. Casali, C. M. Greenfield, R. Groebner, C. T. Holcomb, S. Hong, A. Jarvinen, A. Leonard, A. McLean, et al.

    An error was made in the compilation of Fig. 14 of the original paper1 by including a copyrighted image as a sub-element of that figure, which the author had no

  • Open Access

    DIII-D's role as a national user facility in enabling the commercialization of fusion energy

    by R. J. Buttery, T. Abrams, L. Casali, C. M. Greenfield, R. Groebner, C. T. Holcomb, S. Hong, A. Jaervinen, A. Leonard, A. McLean, et al.

    The path to fusion in the United States requires partnership between public and private sector. While the private sector provides the vigor to take some of the major steps necessary, there is a depth of expertise and capability in the public sector that is vital to resolving feasible approaches. As an open national user facility, DIII-D provides a crucial testbed to develop the required new technologies and approaches in relevant conditions. It has unparalleled potential to meet this challenge, thanks to its extreme flexibility and world leading diagnostics. This provides a basis to rapidly develop solutions that project to future reactors with confidence. The program has thus been redeveloped to enable public and private sector engagement and testing of new concepts. A new technology program has been launched to resolve plasma interacting technologies. With modest heating upgrades, the facility can confront the crucial “Integrated Tokamak Exhaust and Performance” gap, to resolve core, exhaust and technology solutions together. The device is also being redeveloped as a training facility, with dedicated student run time, a mentorship program, and open access to all opportunity roles, part of wider efforts to diversify and open pathways through inclusion, access, and equity. This exciting agenda is enabling scientists and technology researchers to pioneer the solutions needed for a Fusion Pilot Plant (FPP) and ITER this decade. As a national user facility, DIII D has singular potential to provide the tools, teams, and insight necessary, to do its part in moving the United States rapidly toward the commercialization of fusion energy.


  • Response of thermal and fast-ion transport to beam ion population, rotation and T e/T i in the DIII-D steady state hybrid scenario

    by K.E. Thome, Xiaodi Du, B.A. Grierson, Gerrit J Kramer, Craig Petty, Christopher Holland, M. Knolker, George R McKee, Joseph McClenaghan, David C Pace, et al.

    The thermal and fast-ion transport properties of DIII-D steady-state hybrid discharges with normalized beta β N ≳ 3 are studied at low injected torque and an increased electron to ion temperature ratio T e/T i. Linear stability analysis performed with the TGLF turbulent code indicates that a high-k mode is usually dominant at smaller radii, whereas a low-k mode is usually dominant at larger radii in these plasmas. A reduction in the net injected torque from 8.6 to 4.3 N-m leads to reduced E × B shear and hence, an enhanced turbulence that was observed on the Doppler backscattering diagnostic and was also computed with TGLF. As T e/T i in the core was increased from 0.57 to 0.66 by adding electron cyclotron current drive (ECCD) to these plasmas, higher levels of transport are observed with increased high-k modes indicated by TGLF. The fast-ion transport level varied over an order of magnitude in these discharges depending on whether Alfvén eigenmodes, fishbones, or no instabilities were observed. Hybrid plasmas with fishbones have decreased fast-ion transport, compared to plasmas with Alfvén eigenmodes, since they are resonant with a smaller portion of phase space and their resonance is farther from the wall. This reduction in fast-ion transport with ECCD mitigates the increase in turbulent transport, resulting in higher performance than expected during strong electron heating. Similarly, the lowest fast-ion transport was observed in the low torque plasma, which also led to better than expected performance at this torque value. The thermal and fast-ion transport changes observed as the torque/rotation and T e/T i are varied indicate possible methods for transferring this scenario to a reactor.


  • Central ion cyclotron emission in the DIII-D tokamak

    by K.E. Thome, David C Pace, R.I. Pinsker, M.A. Van Zeeland, William W Heidbrink, M.E. Austin


  • Feedback control of stored energy and rotation with variable beam energy and perveance on DIII-D

    by Boyer, Keith Erickson, B.A. Grierson, David C Pace, J.T. Scoville, Joe Rauch, Brendan Crowley, John R Ferron, Shaun R Haskey, D.A. Humphreys, et al.


  • Open Access

    Toroidal variation of the strike point in DIII-D

    by J.G. Watkins, H.Q. Wang, J.L. Barton, A. Wingen, D. Pace, A. Moser, I. Bykov, R. Masline, D.M. Thomas, H.Y. Guo


  • Radio frequency measurements of energetic-particle-driven emission using the ion cyclotron emission diagnostic on the DIII-D tokamak

    by K. E. Thome, D. C. Pace, R. I. Pinsker, O. Meneghini, C. A. del Castillo, Y. Zhu

    The Ion Cyclotron Emission (ICE) diagnostic on the DIII-D tokamak consists of two outboard midplane systems. In the first system, straps of an ion cyclotron range of frequencies antenna are configured as receiving antennas. For the second system, dedicated magnetic probes incorporated into the outer wall of carbon tiles have recently been restored. These systems collected a large set of radio frequency measurements in the 2015–2018 experimental campaigns by digitizing signals at 200 MSamples/s for ∼5 s per discharge. Each shot typically yields 32 GB of data; techniques for successful handling and analysis of this challengingly large dataset are discussed. The raw voltage fluctuations (<0.2 V and <1 mW) are analyzed in frequency space via fast Fourier transforms. Signals can be analyzed between 1 and 200 MHz with appropriate filtering and aliasing; this frequency range is limited by DC breaks used to provide 5 kV DC isolation. These high-frequency signals are driven by energetic ions and electrons. In particular, energetic-ion-driven ICE occurs at harmonics of the ion cyclotron frequency, enabling the frequency to be mapped to lab space via equilibrium reconstruction. In many DIII-D plasmas, ICE is emitted from the radial center of the plasma.


  • Dynamic neutral beam current and voltage control to improve beam efficacy in tokamaks

    by D. C. Pace, M. E. Austin, L. Bardoczi, C. S. Collins, B. Crowley, E. Davis, X. Du, J. Ferron, B. A. Grierson, W. W. Heidbrink, et al.

    An engineering upgrade to the neutral beam system at the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] enables time-dependent programming of the beam voltage and current. Initial application of this capability involves pre-programmed beam voltage and current injected into plasmas that are known to be susceptible to instabilities that are driven by energetic ( E ≥ 40 keV) beam ions. These instabilities, here all Alfvén eigenmodes (AEs), increase the transport of the beam ions beyond a classical expectation based on particle drifts and collisions. Injecting neutral beam power, P beam ≥ 2 MW, at reduced voltage with increased current reduces the drive for Alfvénic instabilities and results in improved ion confinement. In lower-confinement plasmas, this technique is applied to eliminate the presence of AEs across the mid-radius of the plasmas. Simulations of those plasmas indicate that the mode drive is decreased and the radial extent of the remaining modes is reduced compared to a higher beam voltage case. In higher-confinement plasmas, this technique reduces AE activity in the far edge and results in an interesting scenario of beam current drive improving as the beam voltage reduces from 80 kV to 65 kV.


  • Resolving runaway electron distributions in space, time, and energy

    by C. Paz-Soldan, C. M. Cooper, P. Aleynikov, N. W. Eidietis, A. Lvovskiy, D. C. Pace, D. P. Brennan, E. M. Hollmann, C. Liu, R. A. Moyer, et al.

    Areas of agreement and disagreement with present-day models of runaway electron (RE) evolution are revealed by measuring MeV-level bremsstrahlung radiation from runaway electrons (REs) with a pinhole camera. Spatially resolved measurements localize the RE beam, reveal energy-dependent RE transport, and can be used to perform full two-dimensional (energy and pitch-angle) inversions of the RE phase-space distribution. Energy-resolved measurements find qualitative agreement with modeling on the role of collisional and synchrotron damping in modifying the RE distribution shape. Measurements are consistent with predictions of phase-space attractors that accumulate REs, with non-monotonic features observed in the distribution. Temporally resolved measurements find qualitative agreement with modeling on the impact of collisional and synchrotron damping in varying the RE growth and decay rate. Anomalous RE loss is observed and found to be largest at low energy. Possible roles for kinetic instability or spatial transport to resolve these anomalies are discussed.


  • Smoothly Varying Injected Neutral Beam Voltage and Current Provides New Capability on the DIII-D Tokamak

    by J. T. Scoville, B. J. Crowley, D. C. Pace, J. M. Rauch

    A significant engineering upgrade of the DIII-D neutral beam system has recently completed, providing ability to smoothly and independently vary the beam voltage and current. This enables greater control of the injected beam power, torque, and plasma instability drive for fusion experiments. Modifications to the high-voltage equipment and the plasma control system were made and tested over the last year to allow beam energy to vary by as much as 20 kV over a 0.5-s period anywhere within the 45-85 kV operating range of the beams. The beam current can be made to track the voltage (keeping the perveance constant), or the current and voltage can be varied independently (scanning the perveance). The smooth variation of beam energy avoids the extremely perturbative effects of pulsewidth modulation, the only tool previously used for regulating the injected neutral beam power. With independent control of voltage and current, the beam ion velocity space can be tailored to facilitate new experiments that explore, for example, the detrimental effects of Alfvén eigenmodes. These modes are driven by energetic particles and can possibly be avoided in steady-state scenarios by timely variation of the beam energy while maintaining constant input power. A description of the modifications made to the power supply and beam controls will be presented, as well as some initial physics results employing the new variable beam energy system.