Qunfang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qunfang Zhang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Yifang Zhu
5 shared publications- Jianguo Jiang
School of Environment Tsinghua University Beijing 100084 China
2 shared publications - Yifang Zhu
Texas A&M University-Kingsville, Department of Environmental Engineering, 700 University Blvd. MSC 213, Kingsville, TX 78363, USA
2 shared publications Arthur M. Winer
1 shared publication- David C. Quiros
California Air Resources Board
1 shared publication - David Ramirez
Texas A&M University-Kingsville
1 shared publication
Latest Publications
- Open Access
Functional Time Series Models for Ultrafine Particle Distributions
We propose Bayesian random effect functional time series models to model the impact of engine idling on ultrafine particle (UFP) counts inside school buses. UFPs are toxic to humans with health effects strongly linked to particle size. School engines emit particles primarily in the UFP size range and as school buses idle at bus stops, UFPs penetrate into cabins through cracks, doors, and windows. How UFP counts inside buses vary by particle size over time and under different idling conditions is not yet well understood. We model UFP counts at a given time with a cubic B-spline basis as a function of size and allow counts to increase over time at a size dependent rate once the engine turns on. We explore alternate parametric models for the engine-on increase which also vary smoothly over size. The log residual variance over size is modeled using a quadratic B-spline basis to account for heterogeneity and an autoregressive model is used for the residual. Model predictions are communicated graphically. These methods provide information needed for regulating vehicle emissions to minimize UFP exposure in the future.
Open AccessFunctional Time Series Models for Ultrafine Particle Distributions
We propose Bayesian random effect functional time series models to model the impact of engine idling on ultrafine particle (UFP) counts inside school buses. UFPs are toxic to humans with health effects strongly linked to particle size. School engines emit particles primarily in the UFP size range and as school buses idle at bus stops, UFPs penetrate into cabins through cracks, doors, and windows. How UFP counts inside buses vary by particle size over time and under different idling conditions is not yet well understood. We model UFP counts at a given time with a cubic B-spline basis as a function of size and allow counts to increase over time at a size dependent rate once the engine turns on. We explore alternate parametric models for the engine-on increase which also vary smoothly over size. The log residual variance over size is modeled using a quadratic B-spline basis to account for heterogeneity and an autoregressive model is used for the residual. Model predictions are communicated graphically. These methods provide information needed for regulating vehicle emissions to minimize UFP exposure in the future.
- 1 March 2014
- No. 180,p. 3-37
Characterizing ultrafine particles and other air pollutants in and around school buses.
Increasing evidence has demonstrated toxic effects of ultrafine particles (UFP*, diameter < 100 nm). Children are particularly at risk because of their immature respiratory systems and higher breathing rates per body mass. This study aimed to characterize UFP, PM2.5 (particulate matter < or = 2.5 microm in aerodynamic diameter), and other vehicular-emitted pollutants in and around school buses. Four sub-studies were conducted, including: 1. On-road tests to measure in-cabin air pollutant levels while school buses were being driven; 2. Idling tests to determine the contributions of tailpipe emissions from idling school buses to air pollutant levels in and around school buses under different scenarios; 3. Retrofit tests to evaluate the performance of two retrofit systems, a diesel oxidation catalyst (DOC) muffler and a crankcase filtration system (CFS), on reducing tailpipe emissions and in-cabin air pollutant concentrations under idling and driving conditions; and 4. High efficiency particulate air (HEPA) filter air purifier tests to evaluate the effectiveness of in-cabin filtration. In total, 24 school buses were employed to cover a wide range of school buses commonly used in the United States. Real-time air quality measurements included particle number concentration (PNC), fine and UFP size distribution in the size range 7.6-289 nm, PM2.5 mass concentration, black carbon (BC) concentration, and carbon monoxide (CO) and carbon dioxide (CO2) concentrations. For in-cabin measurements, instruments were placed on a platform secured to the rear seats inside the school buses. For all other tests, a second set of instruments was deployed to simultaneously measure the ambient air pollutant levels. For tailpipe emission measurements, the exhaust was diluted and then measured by instruments identical to those used for the in-cabin measurements. The results show that when driving on roads, in-cabin PNC, fine and UFP size distribution, PM2.5, BC, and CO varied by engine age, window position, driving speed, driving route, and operating conditions. Emissions from idling school buses increased the PNC close to the tailpipe by a factor of up to 26.0. Under some circumstances, tailpipe emissions of idling school buses increased the in-cabin PNC by factors ranging from 1.2 to 5.8 in the 10-30 nm particle size range. Retrofit systems significantly reduced the tailpipe emissions of idling school buses. With both DOC and CFS installed, PNC in tailpipe emissions dropped by 20%-94%. No unequivocal decrease was observed for in-cabin air pollutants after retrofitting. The operation of the air conditioning (AC) unit and the pollutant concentrations in the surrounding ambient air played more important roles than retrofit technologies in determining in-cabin air quality. The use of a HEPA air purifier removed up to 50% of in-cabin particles. Because each sub-study tested only a subset of the 24 school buses, the results should be seen as more exploratory than definitive.
- 1 March 2014
- No. 180,p. 3-37
Characterizing ultrafine particles and other air pollutants in and around school buses.
Increasing evidence has demonstrated toxic effects of ultrafine particles (UFP*, diameter < 100 nm). Children are particularly at risk because of their immature respiratory systems and higher breathing rates per body mass. This study aimed to characterize UFP, PM2.5 (particulate matter < or = 2.5 microm in aerodynamic diameter), and other vehicular-emitted pollutants in and around school buses. Four sub-studies were conducted, including: 1. On-road tests to measure in-cabin air pollutant levels while school buses were being driven; 2. Idling tests to determine the contributions of tailpipe emissions from idling school buses to air pollutant levels in and around school buses under different scenarios; 3. Retrofit tests to evaluate the performance of two retrofit systems, a diesel oxidation catalyst (DOC) muffler and a crankcase filtration system (CFS), on reducing tailpipe emissions and in-cabin air pollutant concentrations under idling and driving conditions; and 4. High efficiency particulate air (HEPA) filter air purifier tests to evaluate the effectiveness of in-cabin filtration. In total, 24 school buses were employed to cover a wide range of school buses commonly used in the United States. Real-time air quality measurements included particle number concentration (PNC), fine and UFP size distribution in the size range 7.6-289 nm, PM2.5 mass concentration, black carbon (BC) concentration, and carbon monoxide (CO) and carbon dioxide (CO2) concentrations. For in-cabin measurements, instruments were placed on a platform secured to the rear seats inside the school buses. For all other tests, a second set of instruments was deployed to simultaneously measure the ambient air pollutant levels. For tailpipe emission measurements, the exhaust was diluted and then measured by instruments identical to those used for the in-cabin measurements. The results show that when driving on roads, in-cabin PNC, fine and UFP size distribution, PM2.5, BC, and CO varied by engine age, window position, driving speed, driving route, and operating conditions. Emissions from idling school buses increased the PNC close to the tailpipe by a factor of up to 26.0. Under some circumstances, tailpipe emissions of idling school buses increased the in-cabin PNC by factors ranging from 1.2 to 5.8 in the 10-30 nm particle size range. Retrofit systems significantly reduced the tailpipe emissions of idling school buses. With both DOC and CFS installed, PNC in tailpipe emissions dropped by 20%-94%. No unequivocal decrease was observed for in-cabin air pollutants after retrofitting. The operation of the air conditioning (AC) unit and the pollutant concentrations in the surrounding ambient air played more important roles than retrofit technologies in determining in-cabin air quality. The use of a HEPA air purifier removed up to 50% of in-cabin particles. Because each sub-study tested only a subset of the 24 school buses, the results should be seen as more exploratory than definitive.
- 1 April 2013
- Published by Elsevier in Atmospheric Environment
- Vol. 69, 65-75
Ultrafine particle concentrations in and around idling school buses
- 1 April 2013
- Published by Elsevier in Atmospheric Environment
- Vol. 69, 65-75
Ultrafine particle concentrations in and around idling school buses
- 1 March 2013
- Published by Elsevier in Atmospheric Environment
- Vol. 67, 404-414
Air quality impacts of a scheduled 36-h closure of a major highway
- 1 March 2013
- Published by Elsevier in Atmospheric Environment
- Vol. 67, 404-414
Air quality impacts of a scheduled 36-h closure of a major highway
- 1 November 2011
- Published by Elsevier in Atmospheric Environment
- Vol. 45 (36) , 6526-6533
Aircraft emissions and local air quality impacts from takeoff activities at a large International Airport
- 1 November 2011
- Published by Elsevier in Atmospheric Environment
- Vol. 45 (36) , 6526-6533
Aircraft emissions and local air quality impacts from takeoff activities at a large International Airport
- 28 June 2011
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 45 (15) , 6475-6482
Performance of School Bus Retrofit Systems: Ultrafine Particles and Other Vehicular Pollutants
This study evaluated the performance of retrofit systems for diesel-powered school buses, a diesel oxidation catalyst (DOC) muffler and a spiracle crankcase filtration system (CFS), regarding ultrafine particles (UFPs) and other air pollutants from tailpipe emissions and inside bus cabins. Tailpipe emissions and in-cabin air pollutant levels were measured before and after retrofitting when the buses were idling and during actual pick-up/drop off routes. Retrofit systems significantly reduced tailpipe emissions with a reduction of 20–94% of total particles with both DOC and CFS installed. However, no unequivocal decrease was observed for in-cabin air pollutants after retrofitting. The AC/fan unit and the surrounding air pollutant concentrations played more important roles for determining the in-cabin air quality of school buses than did retrofit technologies. Although current retrofit systems reduce children’s exposure while waiting to board at a bus station, retrofitting by itself does not protect children satisfactorily from in-cabin particle exposures. Turning on the bus engine increased in-cabin UFP levels significantly only when the wind blew from the bus’ tailpipe toward its hood with its windows open. This indicated that wind direction and window position are significant factors determining how much self-released tailpipe emissions may penetrate into the bus cabin. The use of an air purifier was found to remove in-cabin particles by up to 50% which might be an alternative short-to-medium term strategy to protect children’s health.
- 28 June 2011
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 45 (15) , 6475-6482
Performance of School Bus Retrofit Systems: Ultrafine Particles and Other Vehicular Pollutants
This study evaluated the performance of retrofit systems for diesel-powered school buses, a diesel oxidation catalyst (DOC) muffler and a spiracle crankcase filtration system (CFS), regarding ultrafine particles (UFPs) and other air pollutants from tailpipe emissions and inside bus cabins. Tailpipe emissions and in-cabin air pollutant levels were measured before and after retrofitting when the buses were idling and during actual pick-up/drop off routes. Retrofit systems significantly reduced tailpipe emissions with a reduction of 20–94% of total particles with both DOC and CFS installed. However, no unequivocal decrease was observed for in-cabin air pollutants after retrofitting. The AC/fan unit and the surrounding air pollutant concentrations played more important roles for determining the in-cabin air quality of school buses than did retrofit technologies. Although current retrofit systems reduce children’s exposure while waiting to board at a bus station, retrofitting by itself does not protect children satisfactorily from in-cabin particle exposures. Turning on the bus engine increased in-cabin UFP levels significantly only when the wind blew from the bus’ tailpipe toward its hood with its windows open. This indicated that wind direction and window position are significant factors determining how much self-released tailpipe emissions may penetrate into the bus cabin. The use of an air purifier was found to remove in-cabin particles by up to 50% which might be an alternative short-to-medium term strategy to protect children’s health.
- Open Access
- 16 April 2010
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 7 (4) , 1744-1759
Measurement of Ultrafine Particles and Other Air Pollutants Emitted by Cooking Activities
Cooking emissions show a strong dependence on cooking styles and parameters. Measurements of the average ultrafine particle (UFP) concentration, PM2.5 and black carbon concentrations emitted by cooking activities ranged from 1.34 × 104 to 6.04 × 105 particles/cm3, 10.0 to 230.9 μg/m3 and 0.1 to 0.8 μg/m3, respectively. Lower UFP concentrations were observed during boiling, while higher levels were emitted during frying. The highest UFP concentrations were observed when using a gas stove at high temperature with the kitchen exhaust fan turned off. The observed UFP profiles were similar in the kitchen and in another room, with a lag of approximately 10 min.
- 16 April 2010
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 7 (4) , 1744-1759
Open AccessMeasurement of Ultrafine Particles and Other Air Pollutants Emitted by Cooking Activities
Cooking emissions show a strong dependence on cooking styles and parameters. Measurements of the average ultrafine particle (UFP) concentration, PM2.5 and black carbon concentrations emitted by cooking activities ranged from 1.34 × 104 to 6.04 × 105 particles/cm3, 10.0 to 230.9 μg/m3 and 0.1 to 0.8 μg/m3, respectively. Lower UFP concentrations were observed during boiling, while higher levels were emitted during frying. The highest UFP concentrations were observed when using a gas stove at high temperature with the kitchen exhaust fan turned off. The observed UFP profiles were similar in the kitchen and in another room, with a lag of approximately 10 min.
- 1 January 2010
- Published by Elsevier in Atmospheric Environment
- Vol. 44 (2) , 253-261
Measurements of ultrafine particles and other vehicular pollutants inside school buses in South Texas
- 1 January 2010
- Published by Elsevier in Atmospheric Environment
- Vol. 44 (2) , 253-261
Measurements of ultrafine particles and other vehicular pollutants inside school buses in South Texas
- 1 September 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 60 (6) , 1445-1453
Disintegration of sewage sludge with bifrequency ultrasonic treatment
A bifrequency ultrasonic generating trough was used to improve disintegration of sewage sludge from thickener tanks. Ultrasonic operating parameters such as frequency, power, and time were optimized. Ultrasonic treatment successfully disintegrated the floc structure of sewage sludge and promoted the release of organic matter and metal ions such as Ca2 + and Mg2 + . After ultrasonic treatment, soluble chemical oxygen demand (SCOD) in the sludge solution increased 11.28–49.06%, while the concentrations of Ca2 + and Mg2 + rose 5.5–25.0% and 2.7–19.0%, respectively. The ultrasonic frequency of 25 kHz was most effective in disintegrating sludge, and high energy densities and longer treatment time increased SCOD and metal ion release. The optimal parameters that promoted the increase SCOD were 25 kHz, 75 W/L and 60 s. Under these conditions, double-frequency ultrasonication was more effective than single-frequency ultrasonication.
- 1 September 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 60 (6) , 1445-1453
Disintegration of sewage sludge with bifrequency ultrasonic treatment
A bifrequency ultrasonic generating trough was used to improve disintegration of sewage sludge from thickener tanks. Ultrasonic operating parameters such as frequency, power, and time were optimized. Ultrasonic treatment successfully disintegrated the floc structure of sewage sludge and promoted the release of organic matter and metal ions such as Ca2 + and Mg2 + . After ultrasonic treatment, soluble chemical oxygen demand (SCOD) in the sludge solution increased 11.28–49.06%, while the concentrations of Ca2 + and Mg2 + rose 5.5–25.0% and 2.7–19.0%, respectively. The ultrasonic frequency of 25 kHz was most effective in disintegrating sludge, and high energy densities and longer treatment time increased SCOD and metal ion release. The optimal parameters that promoted the increase SCOD were 25 kHz, 75 W/L and 60 s. Under these conditions, double-frequency ultrasonication was more effective than single-frequency ultrasonication.
- 1 October 2008
- Vol. 29 (10) , 2815-9
[Improvement of disintegration and anaerobic digestion for sewage sludge with ultrasonic generator].
Ultrasonic generating trough was applied to study the impact of ultrasonic on conditioning of sewage sludge. There are few ultrasonic generators for sludge treatment specifically, so we designed a double-frequency ultrasonic generating trough which could adjust frequency, energy density and treating time flexibly. In the research characteristics of sewage sludge treated by single-frequency and double-frequency ultrasonic were compared. According to the results, the digestion biogas of the sewage sludge treated by ultrasonic increase obviously, and the digestion biogas increment of the sewage sludge treated by single-frequency is 40.93%, higher than that treated by double-frequency. But the SCOD of the sewage sludge treated by double-frequency is 23.5%, more than that treated by single-frequency.
- 1 October 2008
- Vol. 29 (10) , 2815-9
[Improvement of disintegration and anaerobic digestion for sewage sludge with ultrasonic generator].
Ultrasonic generating trough was applied to study the impact of ultrasonic on conditioning of sewage sludge. There are few ultrasonic generators for sludge treatment specifically, so we designed a double-frequency ultrasonic generating trough which could adjust frequency, energy density and treating time flexibly. In the research characteristics of sewage sludge treated by single-frequency and double-frequency ultrasonic were compared. According to the results, the digestion biogas of the sewage sludge treated by ultrasonic increase obviously, and the digestion biogas increment of the sewage sludge treated by single-frequency is 40.93%, higher than that treated by double-frequency. But the SCOD of the sewage sludge treated by double-frequency is 23.5%, more than that treated by single-frequency.