SCSteve Q. Cai

Steve Q. Cai

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steve Q. Cai has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Acoustic Radiation, Cavitation Collapses, and Dryout in a Capillary Oscillating Heat Pipe

    by Steve Q. Cai

    In an oscillation heat pipe (OHP), when two-phase flow oscillates to the condensation region, saturated vapor bubbles/slugs are subjected to a sudden temperature reduction or immediate subcooling. Rapid condensation ruptures vapor bubbles and generates cavitation erosions on the tube interior surface. In this article, a thorough study is performed to understand discrepancy of variation tendency between acoustic radiation and OHP temperature difference that both are operating temperature-dependent. On this basis, three temperature zones were identified: (1) low operating temperature zone with strong cavitation collapse and acoustic radiations, (2) optimal temperature zone with the minimum temperature difference and weakening cavitation collapses, and, (3) high-temperature zone where dryout and oscillation failures develop. At the optimal operating temperature, high-frequent oscillations reduce subcooling of two-phase flow, alleviating the impact of cavitation collapses and ceasing acoustic radiations. At high operating temperature, liquid surface tension dramatically reduces and dynamic contact angle significantly increases. Both the factors tend to lower the critical diameter necessary to maintain pressure difference and oscillating two-phase slug flow. When the critical diameter reduces to be less than the OHP tube diameter, liquid slugs are not able to seal the OHP capillary tubes, leading to dryout or insufficient heat and mass transfer.


  • A Passive and Remote Heat Transfer Solution for Avionics Thermal Management

    by Steve Q. Cai, Avijit Bhunia, Julie F. Asfia

    A heat pipe utilizes liquid–vapor phase change mechanism to efficiently transfer heat. Among different heat pipes, loop heat pipe (LHP) and pulsating heat pipe (PHP) are known to be capable of high heat flux/high load heat transfer. In this article, LHP and PHP heat transfer systems are combined to achieve passive, reliable, and remote/long-distance heat transfer for thermal management of modern avionics systems. Aiming at this goal, a 2 m long LHP is developed to transport heat from the avionics chassis to the remote heat rejection site. To reduce inner saturation pressure and ensure structural safety at high operating temperature, water is used as the operating fluid in LHP. Within the avionics chassis, conduction heat transfer is enhanced by sandwiching a PHP with two printed circuit boards (PCBs) and solder-bonding them. Each PHP/PCB assembly is 20 cm long and 12.5 cm wide, with electrical heaters mounted on both sides to mimic electronic heat dissipation. Heat transfer demonstration of the LHP and PHP combo system is conducted in a lab environment with input power varying from 100 to 400 W. For all the three PHP/PCB assemblies set in the avionic chassis, heat source temperature is maintained below the required 150 °C even when heat dissipation is twice as high as the state-of-the-art (and coolant temperature is 50 °C). This combo heat transfer system reduces power consumption and increases reliability, enabling the avionic system operation in harsh environments.


  • Dropwise Condensation on/in High Roughness Structures

    by Steve Q. Cai, Avijit Bhunia

    Water droplets on bio-mimicked hierarchical roughness exhibit superhydrophobic properties, such as large contact angles, minor dynamic hysteresis, and high mobility. Vapor condensation on such superhydrophobic surface enables rapid condensate removal and surface cleaning, thereby significantly enhancing the heat transfer coefficient. In this paper, research attention is given to dropwise condensation on/in specially designed one-tier and hierarchical roughness structures. Utilizing a normal optical tomographic system composed of a Sensi-Cam and a Nikon microscope, close-up visualization is conducted to characterize small condensate droplets, in size of a few micrometers, between structural units of roughness. Experimental snapshots show that, within the one-tier roughness, condensate droplets tend to stick to surrounding structures. Low mobility of these droplets extends their residence time, and therefore increases their average diameter. In comparison, surface energy of the hierarchical structure is significantly reduced. As a result, small condensate droplets behave nonsticky to their surroundings, which enable rapid drain of the droplets and accomplish self-cleaning of the structure. Because of high mobility, the droplet average diameter in the two-tier structure is smaller than those in the one-tire roughness. Condensation sites reach the maximum in the middle of the structure where dew point of moisture is reached. Less condensation droplets on both the top and bottom of the roughness are blamed to the unsaturated moisture and the reduced humidity, respectively.


  • Effect of Liquid Properties on Phase-Change Heat Transfer in Porous Wick Structures

    by Steve Q. Cai, Avijit Bhunia

    In a heat pipe, operating fluid saturates wick structures system and establishes a capillary-driven circulation loop for heat transfer. Thus, the thermophysical properties of the operating fluid inevitably impact the transitions of phase-change mode and the capability of heat transfer, which determine both the design and development of the associated heat pipe systems. This article investigates the effect of liquid properties on phase-change heat transfer. Two different copper wick structures, cubic and cylindrical in cross section, 340 μm in height and 150 μm in diameter or width, are fabricated using an electroplating technique. The phase-change phenomena inside these wick structures are observed at various heat fluxes. The corresponding heat transfer characteristics are measured for three different working liquids: water, ethanol, and Novec 7200. Three distinct modes of the phase-change process are identified: (1) evaporation on liquid–vapor interface, (2) nucleate boiling with interfacial evaporation, and (3) boiling enhanced interface evaporation. Transitions between the three modes depend on heat flux and liquid properties. In addition to the mode transition, liquid properties also dictate the maximum heat flux and the heat transfer coefficient. A quantitative characterization shows that the maximum heat flux scales with Merit number, a dimensionless number connecting liquid density, surface tension, latent heat of vaporization, and viscosity. The heat transfer coefficient, on the other hand, is dictated by the thermal conductivity of the liquid. A complex interaction between the mode transition and liquid properties is reflected in Novec 7200. In spite of having the lowest thermal conductivity among the three liquids, an early transition to the mode of the boiling enhanced interface evaporation leads to a higher heat transfer coefficient at low heat flux.


  • Characterization of Phase Change Heat and Mass Transfers in Monoporous Silicon Wick Structures

    by Steve Q. Cai, Avijit Bhunia

    Silicon is the primary material of integrated circuit (IC) manufacturing in microelectronic industry. It has high thermal conductivity and superior thermomechanical properties compatible to most semiconductors. These characteristics make it an ideal material for fabricating micro/mini heat pipes and their wick structures. In this article, silicon wick structures, composed of cylindrical pillars 320 μm in height and 30–100 μm in diameter, are developed for studies of phase change capability. Fabrication of the silicon wick structures utilizes the standard microelectromechanical systems (MEMS) approach, which allows the precise definition on the wick dimensions, as well as the heated wick area. On these bases, experimental characterizations of temperature variations versus input heat fluxes, associated with simultaneous visualization on the liquid transport and the dryout, are performed to investigate the wick dimensional effects on the maximum phase change capability. On the wick structure with the pillar diameter/pores of 100 μm and a heated wick area of 2 mm × 2 mm, the phase change reached a maximum heat flux of 1130 W/cm2. Despite of the liquid bottom-feed approach, interactions between liquid and vapor phases enables the heated wick structure absorb liquid from its surrounding wick area, including from its top side with a longer liquid transport path. In contrast, a wick structure with fine pillars (10 μm in diameter) inhibited the generation of nucleate boiling. Evaporation on the meniscus interface becomes the major phase change mechanism. A large heated wick area (4 mm × 4 mm) increases the viscous loss in transporting liquid to wet the entire wick, advancing the dryout at 135 W/cm2. Mass transfer analysis, as well as discussion of the experimental results, indicates that a dimensional ratio r/l (pillar diameter/characteristic length of the heated wick area) is a key parameter in determining the maximum phase change capability. A low r/l ratio enhances heat and mass transport capability, as well as heat transfer coefficient.