Silvio Scena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Silvio Scena has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Eli Carmeli
University of Haifa
2 shared publications R. Steindler
Department of Mechanics and Aeronautics of Rome University “La Sapienza”, Rome, Italy
2 shared publicationsRoberto Steindler
Department of Mechanical and Aerospace Engineering, University of Rome "La Sapienza", Via Eudossiana 18, 00184 Roma, Italy
2 shared publications- Einat Kodesh
Pediatric Cardiology Unit, Padeh Medical Center, Poriya, Israel
1 shared publication M. Costarella
Israelitic Hospital, Via Fulda 14, I-00148 Roma, Italy
1 shared publicationMichal Katz-Laurer
School of Health Professions, Tel Aviv University, Tel Aviv, Israel
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by Elmer Press, Inc. in Journal of Clinical Medicine Research
- Vol. 8 (10) , 715-720
Computerized Functional Reach Test to Measure Balance Stability in Elderly Patients With Neurological Disorders
The ability to maintain static and dynamic balance is a prerequisite for safe walking and for obtaining functional mobility. For this reason, a reliable and valid means of screening for risk of falls is needed. The functional reach test (FRT) is used in many countries, yet it does not provide some kinematic parameters such as shoulder or pelvic girdles translation. The purpose was to analyze video records measuring of distance, velocity, time length, arm direction and girdles translation while doing FRT. A cross-sectional, descriptive study was conducted where the above variables were correlated to the mini-mental state examination (MMSE) for mental status and the Tinetti balance assessment test, which have been validated, in order to computerize the FRT (cFRT) for elderly patients with neurological disorders. Eighty patients were tested and 54 were eligible to serve as experimental group. The patients underwent the MMSE, the Tinetti test and the FRT. LAB view software was used to record the FRT performances and to process the videos. The control group consisted of 51 healthy subjects who had been previously tested. The experimental group was not able to perform the tests as well as the healthy control subjects. The video camera provided valuable kinematic results such as bending down while performing the forward reach test. Instead of manual measurement, we proposed to use a cheap with fair resolution web camera to accurately estimate the FRT. The kinematic parameters were correlated with Tinetti and MMSE scores. The performance values established in this study indicate that the cFRT is a reliable and valid assessment, which provides more accurate data than "manual" test about functional reach.
- 1 January 2016
- Published by Elmer Press, Inc. in Journal of Clinical Medicine Research
- Vol. 8 (10) , 715-720
Open AccessComputerized Functional Reach Test to Measure Balance Stability in Elderly Patients With Neurological Disorders
The ability to maintain static and dynamic balance is a prerequisite for safe walking and for obtaining functional mobility. For this reason, a reliable and valid means of screening for risk of falls is needed. The functional reach test (FRT) is used in many countries, yet it does not provide some kinematic parameters such as shoulder or pelvic girdles translation. The purpose was to analyze video records measuring of distance, velocity, time length, arm direction and girdles translation while doing FRT. A cross-sectional, descriptive study was conducted where the above variables were correlated to the mini-mental state examination (MMSE) for mental status and the Tinetti balance assessment test, which have been validated, in order to computerize the FRT (cFRT) for elderly patients with neurological disorders. Eighty patients were tested and 54 were eligible to serve as experimental group. The patients underwent the MMSE, the Tinetti test and the FRT. LAB view software was used to record the FRT performances and to process the videos. The control group consisted of 51 healthy subjects who had been previously tested. The experimental group was not able to perform the tests as well as the healthy control subjects. The video camera provided valuable kinematic results such as bending down while performing the forward reach test. Instead of manual measurement, we proposed to use a cheap with fair resolution web camera to accurately estimate the FRT. The kinematic parameters were correlated with Tinetti and MMSE scores. The performance values established in this study indicate that the cFRT is a reliable and valid assessment, which provides more accurate data than "manual" test about functional reach.
- 20 May 2014
- Published by Taylor & Francis in European Journal of Physiotherapy
- Vol. 16 (3) , 168-172
Functional reach test performance in distance and velocity – A pilot study
- 20 May 2014
- Published by Taylor & Francis in European Journal of Physiotherapy
- Vol. 16 (3) , 168-172
Functional reach test performance in distance and velocity – A pilot study
- 29 February 2012
- Published by Elsevier in Archives of Gerontology and Geriatrics
- Vol. 54 (1) , 72-77
Changes of psychical and physical conditions in the elderly after a four-year follow-up
- 29 February 2012
- Published by Elsevier in Archives of Gerontology and Geriatrics
- Vol. 54 (1) , 72-77
Changes of psychical and physical conditions in the elderly after a four-year follow-up
Methods for Sitting Posture Evaluation: Static Posture and Applications
Abstract: Pressure sores (PS), are frequent in subjects with spinal cord injuries, and to minimize PS these subjects must get used to frequently changing their posture; useful information to this aim may come by testing healthy subjects and studying their kinematic behaviour during long sitting sessions. Two different investigation systems have been developed to this aim in the Department of Mechanics and Aeronautics (DMA) of Rome University ‘‘La Sapienza’’: the two systems, a pressure map sensor arranged on a chair and a potentiometer‐based device to measure trunk rotations at the base of the spine are shown in this paper and their outputs are compared and correlated. The behaviour of ten healthy subjects is then evaluated during a one hour sitting session for preliminary consideration: there is a postural change every 7.7 ± 6.7 minutes in the frontal plane and every 5.7 ± 2.7 minutes in the sagittal plane; pelvis movements can be resumed by Centre of Pressure (COP) displacements and the largest values of these displacements are 5.2 ± 2.4 cm in the frontal plane and 3.0 ± 1.4 cm in the sagittal plane; the largest rotations in the two planes are respectively 8.4 ± 0.7° and 20.7 ± 12.6°. The results of the study are discussed and satisfactorily compared with literature results.
Methods for Sitting Posture Evaluation: Static Posture and Applications
Abstract: Pressure sores (PS), are frequent in subjects with spinal cord injuries, and to minimize PS these subjects must get used to frequently changing their posture; useful information to this aim may come by testing healthy subjects and studying their kinematic behaviour during long sitting sessions. Two different investigation systems have been developed to this aim in the Department of Mechanics and Aeronautics (DMA) of Rome University ‘‘La Sapienza’’: the two systems, a pressure map sensor arranged on a chair and a potentiometer‐based device to measure trunk rotations at the base of the spine are shown in this paper and their outputs are compared and correlated. The behaviour of ten healthy subjects is then evaluated during a one hour sitting session for preliminary consideration: there is a postural change every 7.7 ± 6.7 minutes in the frontal plane and every 5.7 ± 2.7 minutes in the sagittal plane; pelvis movements can be resumed by Centre of Pressure (COP) displacements and the largest values of these displacements are 5.2 ± 2.4 cm in the frontal plane and 3.0 ± 1.4 cm in the sagittal plane; the largest rotations in the two planes are respectively 8.4 ± 0.7° and 20.7 ± 12.6°. The results of the study are discussed and satisfactorily compared with literature results.