Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maksym Tryus has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stabilizing direct laser acceleration with long-scale-length plasma targets

    by Tamir Cohen, Talia Meir, Itamar Cohen, Assaf Levanon, Filip Grepl, Maksym Tryus, Valeria Istokskaia, Francesco Schillaci, Lorenzo Giuffrida, Moshe Fraenkel, et al.

    We investigate the influence of plasma scale length on electron beam stability in direct laser acceleration (DLA) using a series of experiments on multiple laser systems with peak power spanning from 20 to 140 TW. An ultrashort, relativistic-intensity laser pulse interacts with a pre-expanded near-critical-density plasma formed by a nanosecond pre-pulse. We show that plasma expansion times of tens of nanoseconds, corresponding to long, shallow density gradients, result in electron beam pointing stability below 1° (RMS). Two-dimensional particle-in-cell simulations reveal that extended scale lengths suppress laser-driven filamentation and promote sustained self-focusing, leading to a stable acceleration channel. These results establish long-scale-length plasma targets as a robust route to improving beam stability in DLA, specifically when applied as laser-driven electron and neutron sources. Using this electron source, we demonstrated photoneutron generation with up to 9.1×107 neutrons per shot.


  • Open Access

    A Platform for Laser-Driven Ion Sources Generated with Nanosecond Laser Pulses in the Intensity Range of 1013–1015 W/cm2

    by L. Giuffrida, V. Istokskaia, A. Picciotto, V. Kantarelou, M. Barozzi, R. Dell`anna, M. Divoky, O. Denk, D. Giubertoni, F. Grepl, et al.

    An experimental platform for laser-driven ion (sub-MeV) acceleration and potential applications was commissioned at the HiLASE laser facility. The auxiliary beam of the Bivoj laser system operating at a GW level peak power (~10 J in 5–10 ns) and 1–10 Hz repetition rate enabled a stable production of high-current ion beams of multiple species (Al, Ti, Fe, Si, Cu, and Sn). The produced laser–plasma ion sources were fully characterized against the laser intensity on the target (1013–1015 W/cm2) by varying the laser energy, focal spot size, and pulse duration. The versatility and tuneability of such high-repetition-rate laser–plasma ion sources are of potential interest for user applications. Such a statistically accurate study was facilitated by the large amount of data acquired at the high repetition rate (1–10 Hz) provided by the Bivoj laser system.


  • Open Access

    Laser-Driven Ion Sources Generated by Ns Laser Pulses at the Intensity Range of 1013–1015 W/cm2

    by Lorenzo Giuffrida, Valeriia Istokskaia, Antonino Picciotto, Vasiliki Kantarelou, Mario Barozzi, Rosanna Dell`anna, Martin Divoký, Ondrej Denk, Damiano Giubertoni, Filip Grepl, et al.

    An experimental platform for laser-driven ion (sub-MeV) acceleration and potential applications was recently commissioned at the HiLASE laser facility. The auxiliary beam of the Bivoj laser system operating at GW peak power (~10 J in 5-10 ns) and 1-10 Hz repetition rate enabled a sta-ble production of high-current ion beams of multiple species (Al, Ti, Fe, Si, Cu, Sn). The pro-duced laser-plasma ion sources were fully characterized against the laser intensity on target (1013-1015 W/cm2) by varying the laser energy, focal spot size, and pulse duration. This al-lowed to provide accurate scaling laws of the maximum ion energy for the different target ma-terials investigated. Such experimental scaling laws are presented for the first time in the inves-tigated laser intensity range and for ns-class laser pulses, and allow to provide a qualitative in-terpretation of the laser-plasma interaction underpinning physics, thus to tune the main features of the accelerated ion beams (energy, temperature, and current). Such a detailed study was facil-itated by the large amount of data acquired at high repetition rate (1-10 Hz) provided by the Bivoj laser system. The versatility and tuneability of such high-repetition-rate laser-plasma ion sources are of po-tential interest for multidisciplinary user applications.

  • Open Access

    The ELIMAIA Laser–Plasma Ion Accelerator: Technological Commissioning and Perspectives

    by Francesco Schillaci, Lorenzo Giuffrida, Maksym Tryus, Filip Grepl, Stanislav Stancek, Andriy Velyhan, Valeriia Istokskaia, Tadzio Levato, Giada Petringa, Giuseppe A. P. Cirrone, et al.

    We report on the technological commissioning of the Laser–Plasma Ion Accelerator section of the ELIMAIA user beamline at the ELI Beamlines facility in the Czech Republic. The high-peak, high-average power L3-HAPLS laser system was used with an energy of ~10 J and pulse duration of ~30 fs on target, both in single-pulse and high repetition-rate (~0.5 Hz) mode. The laser pulse was tightly focused to reach ultrahigh intensity on target (~1021 W/cm2) and sustain such laser–plasma interaction regime during high repetition-rate operations. The laser beam, ion beam, and laser–plasma emission were monitored on a shot-to-shot basis, and online data analysis at 0.5 Hz was demonstrated through the full set of used diagnostics (e.g., far and near field, laser temporal diagnostics, X- and gamma-ray detectors, Thomson Parabola ion spectrometer, time-of-flight ion detectors, plasma imaging, etc.). The capability and reliability of the ELIMAIA Ion Accelerator was successfully demonstrated at a repetition rate of 0.5 Hz for several hundreds of consecutive laser shots.


  • Open Access

    Automation of Target Delivery and Diagnostic Systems for High Repetition Rate Laser-Plasma Acceleration

    by Timofej Chagovets, Stanislav Stanček, Lorenzo Giuffrida, Andriy Velyhan, Maksym Tryus, Filip Grepl, Valeriia Istokskaia, Vasiliki Kantarelou, Tuomas Wiste, Juan Carlos Hernandez Martin, et al.

    Fast solid target delivery and plasma-ion detection systems have been designed and developed to be used in high intensity laser-matter interaction experiments. We report on recent progress in the development and testing of automated systems to refresh solid targets at a high repetition rate during high peak power laser operation (>1 Hz), along with ion diagnostics and corresponding data collection and real-time analysis methods implemented for future use in a plasma-based ion acceleration beamline for multidisciplinary user applications.


  • Open Access

    TERESA Target Area at ELI Beamlines

    by Maksym Tryus, Filip Grepl, Timofej Chagovets, Andriy Velyhan, Lorenzo Giuffrida, Stanislav Stancek, Vasiliki Kantarelou, Valeria Istokskaia, Francesco Schillaci, Martina Zakova, et al.

    The TERESA (TEstbed for high REpetition-rate Sources of Accelerated particles) target area, recently commissioned with the L3-HAPLS laser at Extreme Light Infrastructure (ELI)-Beamlines, is presented. Its key technological sections (vacuum and control systems, laser parameters and laser beam transport up to the target) are described, along with an overview of the available plasma diagnostics and targetry, tested at relativistic laser intensities. Perspectives of the TERESA laser–plasma experimental area at ELI-Beamlines are briefly discussed.


  • Optical and structural characterization of orthorhombic LaLuO3 using extreme ultraviolet reflectometry

    by Maksym Tryus, Konstantin V. Nikolaev, Igor A. Makhotkin, Jürgen Schubert, Lidia Kibkalo, Serhiy Danylyuk, Angelo Giglia, Piergiorgio Nicolosi, Larissa Juschkin


  • Spatially Resolved Spectroscopic Extreme Ultraviolet Reflectometry for Laboratory Applications

    by Maksym Tryus, Stefan Herbert, Daniel Wilson, Lukas Bahrenberg, Serhiy Danylyuk, Larissa Juschkin

    Spatially resolved extreme ultraviolet reflectometry is presented in application to a local characterization of thin non-uniform contamination layers. Sample reflectivity mapping is performed, demonstrating high chemical sensitivity of the technique. Amorphous Al2O3 and carbon are determined as the contaminants of the studied silicon wafer. The results correlate with those obtained by energy-filtering photoemission electron microscopy. A laboratory tool is developed that is capable of multi-angle (2°–15°) and spectrally broadband (9.5–17 nm) extreme ultraviolet reflectometry at grazing incidence combined with a reduced sample illumination spot size, enabling spatially resolved metrology. A minimum EUV spot size of 25×30 μm in the sample plane is achieved experimentally.


  • Open Access

    Biomorphous SiC ceramics prepared from cork oak as precursor

    by V.O. Yukhymchuk, V.S. Kiselov, M.Ya. Valakh, M.P. Tryus, M.A. Skoryk, A.G. Rozhin, S.A. Kulinich, A.E. Belyaev


  • Multi‐angle spectroscopic extreme ultraviolet reflectometry for analysis of thin films and interfaces

    by Serhiy Danylyuk, Stefan Herbert, Peter Loosen, Rainer Lebert, Anna Schäfer, Jürgen Schubert, Maksym Tryus, Larissa Juschkin

    Modern nanotechnology is constantly raising demands to quality and purity of thin films and interlayer interfaces. As thicknesses of employed layers decrease to single nanometers, traditional characterization tools are no longer able to satisfy throughput, precision or non‐destructibility requirements. Extreme ultraviolet (EUV) and soft X‐ray reflectometry has not only demonstrated the ability to detect sub‐nm thickness variations but also was shown to be very sensitive to chemical composition changes. Since the laboratory radiation sources in this wavelength range often emit in a relatively broad spectral range, a spectroscopic EUV reflectometry has been developed with the added benefit of a rapid measuring time on the order of milliseconds to seconds. In this paper, the extension of the method to multi‐angle measurements will be presented. It allows to reduce a number of fit parameters in the analysis model, making the method suitable for complex samples of unknown composition. First experimental examples for Si‐based layer systems measured under grazing incidence angles between 2° and 15° will be demonstrated and discussed.