AMAmy McDowell

Amy McDowell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amy McDowell has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A GPU-Accelerated MRI Simulator for Synthetic Image Generation

    by Riccardo Ferrero, Marta Vicentini, Elizabeth Cooke, Cormac McGrath, Aaron McCann, Amy McDowell, Nick Zafeiropoulos, Paul Tofts, Matt G. Hall, Alessandra Manzin

    Magnetic Resonance Imaging (MRI) is an imaging technique that provides detailed structural and functional information about organs and tissues. To support the validation of MRI measurement techniques and provide a tool for scanner benchmarking, we develop an MRI simulator exploiting graphics processing units (GPUs) for computational acceleration. The GPU-Accelerated MRI Simulator (GAMS) enables us to generate synthetic images with high-resolution detail for quantitative estimation of relaxation times. GAMS is designed to reproduce the entire MRI image acquisition pipeline, including the definition of the MRI pulse sequence in a standard Pulseq format, the input of the digital phantom and its voxelization, the time integration of the Bloch equation at voxel level, and the processing of the derived k-space for image synthesis. The Bloch equation solver is implemented in CUDA Fortran, using GPUs to increase computational efficiency. The solver accuracy is tested in simple cases by comparison with analytical solutions and with the open-source Jülich Extensible MRI Simulator (JEMRIS). GAMS is applied to an inverse reconstruction problem to estimate the relaxation properties of a calibration phantom, starting with synthetic data. Then, it is used to reproduce the imaging process of a high-resolution digital brain phantom, generating realistic images under diverse MRI pulse sequences, which enable differentiation of tissues based on relaxation properties and/or proton density. The results demonstrate GAMS’s ability to generate synthetic images of complex anatomical structures comparable to those acquired with real MRI scanners and to reliably quantify sample relaxation properties. The simulator is also characterized by high computational efficiency, extensibility for multi-GPU implementation, and cross-platform compatibility. These features make GAMS a valuable tool for the metrological assessment of quantitative MRI (qMRI) and the testing of new pulse sequences for qMRI technique development.

  • Open Access

    Initial findings using high‐resolution magnetic resonance imaging for visualisation of the sural nerve and surrounding anatomy in healthy volunteers at 7 Tesla

    by Amy R. McDowell, Laura Zambreanu, Hamza A. Salhab, Carolynne M. Doherty, Philippa Bridgen, Pete Lally, Sachit Shah, Zimu Huo, Stephen J. Wastling, Tarek Yousry, et al.

    Background and Aims: Histopathological diagnosis is the gold standard in many acquired inflammatory, infiltrative and amyloid based peripheral nerve diseases and a sensory nerve biopsy of sural or superficial peroneal nerve is favoured where a biopsy is deemed necessary. The ability to determine nerve pathology by high‐resolution imaging techniques resolving anatomy and imaging characteristics might improve diagnosis and obviate the need for biopsy in some. The sural nerve is anatomically variable and occasionally adjacent vessels can be sent for analysis in error. Knowing the exact position and relationships of the nerve prior to surgery could be clinically useful and thus reliably resolving nerve position has some utility.Methods: 7T images of eight healthy volunteers' (HV) right ankle were acquired in a pilot study using a double‐echo in steady‐state sequence for high‐resolution anatomy images. Magnetic Transfer Ratio images were acquired of the same area. Systematic scoring of the sural, tibial and deep peroneal nerve around the surgical landmark 7 cm from the lateral malleolus was performed (number of fascicles, area in voxels and mm2, diameter and location relative to nearby vessels and muscles).Results: The sural and tibial nerves were visualised in the high‐resolution double‐echo in steady‐state (DESS) image in all HV. The deep peroneal nerve was not always visualised at level of interest. The MTR values were tightly grouped except in the sural nerve where the nerve was not visualised in two HV. The sural nerve location was found to be variable (e.g., lateral or medial to, or crossing behind, or found positioned directly posterior to the saphenous vein).Interpretation: High‐resolution high‐field images have excellent visualisation of the sural nerve and would give surgeons prior knowledge of the position before surgery. Basic imaging characteristics of the sural nerve can be acquired, but more detailed imaging characteristics are not easily evaluable in the very small sural and further developments and specific studies are required for any diagnostic utility at 7T.


  • Open Access

    Camera-based Prospective Motion Correction in Paediatric Epilepsy Patients Enables EEG-fMRI Localization Even in High-motion States

    by Mirja Steinbrenner, Amy McDowell, Maria Centeno, Friederike Moeller, Suejen Perani, Sara Lorio, Danilo Maziero, David W. Carmichael

    Background: EEG-fMRI is a useful additional test to localize the epileptogenic zone (EZ) particularly in MRI negative cases. However subject motion presents a particular challenge owing to its large effects on both MRI and EEG signal. Traditionally it is assumed that prospective motion correction (PMC) of fMRI precludes EEG artifact correction. Methods: Children undergoing presurgical assessment at Great Ormond Street Hospital were included into the study. PMC of fMRI was done using a commercial system with a Moiré Phase Tracking marker and MR-compatible camera. For retrospective EEG correction both a standard and a motion educated EEG artefact correction (REEGMAS) were compared to each other. Results: Ten children underwent simultaneous EEG-fMRI. Overall head movement was high (mean RMS velocity < 1.5 mm/s) and showed high inter- and intra-individual variability. Comparing motion measured by the PMC camera and the (uncorrected residual) motion detected by realignment of fMRI images, there was a five-fold reduction in motion from its prospective correction. Retrospective EEG correction using both standard approaches and REEGMAS allowed the visualization and identification of physiological noise and epileptiform discharges. Seven of 10 children had significant maps, which were concordant with the clinical EZ hypothesis in 6 of these 7. Conclusion: To our knowledge this is the first application of camera-based PMC for MRI in a pediatric clinical setting. Despite large amount of movement PMC in combination with retrospective EEG correction recovered data and obtained clinically meaningful results during high levels of subject motion. Practical limitations may currently limit the widespread use of this technology.


  • Open Access

    High‐resolution quantitative MRI of multiple sclerosis spinal cord lesions

    by Amy R. McDowell, Natalia Petrova, Daniele Carassiti, Marc E. Miquel, David L. Thomas, Gareth J. Barker, Klaus Schmierer, Tobias C. Wood

    Purpose: Validation of quantitative MR measures for myelin imaging in the postmortem multiple sclerosis spinal cord.Methods: Four fixed spinal cord samples were imaged first with a 3T clinical MR scanner to identify areas of interest for scanning, and then with a 7T small bore scanner using a multicomponent‐driven equilibrium single‐pulse observation of T1 and T2 protocol to produce apparent proton density, T1, T2, myelin water, intracellular water, and free‐water fraction maps. After imaging, the cords were sectioned and stained with histological markers (hematoxylin and eosin, myelin basic protein, and neurofilament protein), which were quantitatively compared with the MR maps.Results: Excellent correspondence was found between high‐resolution MR parameter maps and histology, particularly for apparent proton density MRI and myelin basic protein staining.Conclusion: High‐resolution quantitative MRI of the spinal cord provides biologically meaningful measures, and could be beneficial to diagnose and track multiple sclerosis lesions in the spinal cord.


  • Clinically feasible diffusion MRI in muscle: Time dependence and initial findings in Duchenne muscular dystrophy

    by Amy R. McDowell, Thorsten Feiweier, Francesco Muntoni, Matt G. Hall, Chris A. Clark

    Purpose: To characterize the diffusion time‐dependence in muscle in healthy adult volunteers, boys with Duchenne’s muscular dystrophy (DMD), and age‐matched controls in a clinically feasible acquisition time for pediatric applications.Methods: Diffusion data were acquired using a pulsed gradient stimulated echo diffusion preparation at 5 different diffusion times (70, 130, 190, 250, and 330 ms), at 4 different b‐values (0, 200, 400, 600, and 800 s/mm2) and 6 directions (orthogonal x, y, and z and diagonal xy, xz, and yz) and processed to obtain standard diffusion indices (mean diffusivity [MD] and fractional anisotropy [FA]) at each diffusion time.Results: Time‐dependent diffusion was seen in muscle in healthy adult volunteers, boys with DMD, and age‐matched controls. Boys with DMD showed reduced MD and increased FA values in comparison to age matched controls across a range of diffusion times. A diffusion time of Δ = 190 ms had the largest effect size.Conclusions: These results could be used to optimize diffusion imaging in this disease further and imply that these diffusion indices may become an important biomarker in monitoring progression in DMD in the future.


  • Multiparametric mapping in post-mortem perinatal MRI: a feasibility study

    by Amy R McDowell, Susan C Shelmerdine, Sara Lorio, Wendy Norman, Rod Jones, David W Carmichael, Owen J Arthurs

    Objectives: To demonstrate feasibility of a 3 T multiparametric mapping (MPM) quantitative pipeline for perinatal post-mortem MR (PMMR) imaging. Methods: Whole body quantitative PMMR imaging was acquired in four cases, mean gestational age 34 weeks, range (29–38 weeks) on a 3 T Siemens Prisma scanner. A multicontrast protocol yielded proton density, T1 and magnetic transfer (MT) weighted multi-echo images obtained from variable flip angle (FA) 3D fast low angle single-shot (FLASH) acquisitions, radiofrequency transmit field map and one B0 field map alongside four MT weighted acquisitions with saturation pulses of 180, 220, 260 and 300 degrees were acquired, all at 1 mm isotropic resolution. Results: Whole body MPM was achievable in all four foetuses, with R1, R2*, PD and MT maps reconstructed from a single protocol. Multiparametric maps were of high quality and show good tissue contrast, especially the MT maps. Conclusion: MPM is a feasible technique in a perinatal post-mortem setting, which may allow quantification of post-mortem change, prior to being evaluated in a clinical setting. Advances in knowledge: We have shown that the MPM sequence is feasible in PMMR imaging and shown the potential of MT imaging in this setting.


  • Open Access

    Flexible proton density (PD) mapping using multi-contrast variable flip angle (VFA) data

    by Sara Lorio, Tim M. Tierney, Amy McDowell, Owen J. Arthurs, Antoine Lutti, Nikolaus Weiskopf, David W. Carmichael


  • Open Access

    Quantifying multiple sclerosis pathology in post mortem spinal cord using MRI

    by K. Schmierer, A. McDowell, N. Petrova, D. Carassiti, D.L. Thomas, M.E. Miquel


  • Open Access

    Optimal repetition time reduction for single subject event‐related functional magnetic resonance imaging

    by Amy R. McDowell, David W Carmichael

    Purpose: Short TRs are increasingly used for fMRI as fast sequences such as simultaneous multislice excitation become available. These have been associated with apparent sensitivity improvements, although greater temporal autocorrelation at shorter TRs can inflate sensitivity measurements leading to uncertainty regarding the optimal approach.Methods: In volunteers (n = 10), the optimal TR was assessed at the single subject level for event‐related designs (visual stimulation) with 4 frequencies of presentation at 4 TR values (412‐2550 ms). T‐values in the visual cortex localized in each individual were obtained and receiver operating characteristics (ROC) analysis was performed by counting voxels within and outside expected task active regions at different thresholds. This analysis was repeated using 4 different autoregressive (AR) models; SPM AR(1) and SPM AR(fast) which globally estimate autocorrelation, and fMRIstat AR(1) and AR(5) that use a local estimate.Results: The use of modest multiband factors of 2 or 3 with a reduction in TR to 1000 ± 200 ms had greater sensitivity and specificity as shown by higher T‐values in visual cortex and ROC analysis. At these TRs, the ROC analysis demonstrated that a local AR model fit improved performance while high order AR models were unnecessary.Conclusions: Modest TR reductions (to 1000 ± 200 ms) optimally improved event‐related fMRI performance independent of design frequency. Autoregressive models with a local as opposed to global fit performed better, while low order autoregressive models were sufficient at the optimal TR.


  • High resolution isotropic diffusion imaging in post-mortem neonates: a feasibility study

    by Amy R McDowell, Susan C Shelmerdine, David W Carmichael, Owen J Arthurs

    Objective: To investigate the potential of advanced diffusion weighted imaging (DWI) in post-mortem MRI (PMMR) at 3T. Methods: We acquired PMMR brain and body imaging in 12 neonates, mean gestational age 33.4 weeks (range 29–37 weeks) at 3T and 1.5T. Head and body diffusion imaging at 1.5T consisted of bipolar diffusion encoding and single-shot spin-echo echo-planar imaging (SE-EPI) for acquisition (echo time (TE) 96 ms; repetition time (TR) 2700 ms; voxel size 1.8 x 1.8 mm in-plane with slice thickness 5 mm; b-values of 500 and 1000 s/mm2 applied in three orthogonal directions; total acquisition time 2:12). A whole-body 3T diffusion imaging protocol using monopolar diffusion encoding and simultaneous multislice EPI acquisition with gradients applied in 12 uniformly distributed directions was obtained (TE 53.4 ms; TR 5600 ms; 1.8 mm isotropic; multiband factor 2; b-values of 250, 750, 1250 and 1750 s/mm2; acquisition time 2:09 for a single b-value). Results: There was significant improvement in image quality in multiband, multislice diffusion PMMR protocol. On visual assessment of image quality, 1.5T DWI scored poorly (mean 2.4 SD ± 0.47), and all 3T b-values individually scored significantly higher (p < 0.001) apart from b = 250 s/mm2 which was not significantly different. Conclusion: Recent advances in diffusion sequences and hardware utilising higher field strengths and gradient performance allows whole-body diffusion PMMR imaging at high resolution with improved image quality compared to the current clinical approach. Advances in knowledge: We have demonstrated feasibility of a multislice, multiband quantitative diffusion imaging sequence in the perinatal post-mortem setting. This will allow more detailed and quantitative clinical PMMR investigations using diffusion MRI in the future.