Dalia N. Elsheakh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dalia N. Elsheakh has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Esmat A. Abdallah
15 shared publications- Angie R. Eldamak
Ain Shams University
9 shared publications - Esmat A. Abdallah
Microstrip Department, Electronics Research Institute (ERI), El Nozha 11843, Egypt
7 shared publications - Omar M. Fahmy
Department of Electrical Engineering, Faculty of Engineering and Technology, Badr University in Cairo, Badr City, Egypt
4 shared publications Angie R. Eldamak
Electronics and Communications Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt
3 shared publications- Gomaa M. Elashry
Microstrip Department, Electronics Research Institute (ERI), El Nozha 11843, Egypt
3 shared publications
Latest Publications
- Open Access
- 10 July 2026
- Published by Springer Nature in Advanced Modeling and Simulation in Engineering Sciences
- Vol. 13 (1) , 15
A compact microwave CSRR resonator for non-invasive glucose sensing enhanced by machine learning
This paper presents a new, compact shape of a planar microwave resonator sensor for non-invasive blood glucose monitoring, enabling effective diabetes management. The proposed sensor is based on four cells of compact, irregularly curved Coupled Split Ring Resonators (CSRRs) printed on an affordable FR4 dielectric substrate. It functions by leveraging the interaction between biological tissues and microwave signals to detect glucose levels accurately. By transmitting microwave signals through the body and analyzing the S-parameters, the sensor identifies changes in the dielectric properties of blood, enabling the measurement of glucose concentrations. The magnitude and phase of S-parameters play a crucial role in providing a comprehensive analysis of glucose-induced variations. To validate the sensor’s performance, simulations use a phantom finger model, with laboratory data employed to verify these results, accounting for potential experimental variability. Sensitivity testing is conducted using glucose solutions with concentrations from 0 to 350 mg/dL. Additionally, machine learning (ML) techniques are integrated to analyze sensor data and enhance glucose detection accuracy. The sensor can adapt to individual differences and environmental factors, improving the overall accuracy and reliability of the glucose monitoring system. Applying classification algorithms and signal processing methods, such as Discrete Wavelet Transform (DWT) decomposition, is used to classify microwave signals according to glucose levels more accurately. The integration of DWT significantly improves classification accuracy, achieving an 80% success rate across different glucose concentrations. The CSRR sensor design demonstrates a strong interaction between glucose samples and electromagnetic fields, resulting in a sensitivity of 10 MHz/(mg/dL) and 3dB/(mg/dL), alongside excellent detection capabilities.
- 10 July 2026
- Published by Springer Nature in Advanced Modeling and Simulation in Engineering Sciences
- Vol. 13 (1) , 15
Open AccessA compact microwave CSRR resonator for non-invasive glucose sensing enhanced by machine learning
This paper presents a new, compact shape of a planar microwave resonator sensor for non-invasive blood glucose monitoring, enabling effective diabetes management. The proposed sensor is based on four cells of compact, irregularly curved Coupled Split Ring Resonators (CSRRs) printed on an affordable FR4 dielectric substrate. It functions by leveraging the interaction between biological tissues and microwave signals to detect glucose levels accurately. By transmitting microwave signals through the body and analyzing the S-parameters, the sensor identifies changes in the dielectric properties of blood, enabling the measurement of glucose concentrations. The magnitude and phase of S-parameters play a crucial role in providing a comprehensive analysis of glucose-induced variations. To validate the sensor’s performance, simulations use a phantom finger model, with laboratory data employed to verify these results, accounting for potential experimental variability. Sensitivity testing is conducted using glucose solutions with concentrations from 0 to 350 mg/dL. Additionally, machine learning (ML) techniques are integrated to analyze sensor data and enhance glucose detection accuracy. The sensor can adapt to individual differences and environmental factors, improving the overall accuracy and reliability of the glucose monitoring system. Applying classification algorithms and signal processing methods, such as Discrete Wavelet Transform (DWT) decomposition, is used to classify microwave signals according to glucose levels more accurately. The integration of DWT significantly improves classification accuracy, achieving an 80% success rate across different glucose concentrations. The CSRR sensor design demonstrates a strong interaction between glucose samples and electromagnetic fields, resulting in a sensitivity of 10 MHz/(mg/dL) and 3dB/(mg/dL), alongside excellent detection capabilities.
- Open Access
- 22 April 2026
- Published by OAE Publishing Inc. in Soft Science
- Vol. 6 (2)
Multimodal biosensing platforms for sensor-computing integration towards intelligent healthcare
Integrated multimodal biosensing platforms are transforming the landscape of bioanalytical technologies by enabling real-time, high-resolution, and multifunctional detection of physiological and environmental biomarkers. This review summarizes the evolution from traditional single-modal biosensors to advanced multimodal systems that unify diverse sensing modalities with computation and storage functionalities. The introduction on the transduction mechanisms of different biosensors and the representative biomarkers was first provided, highlighting the advantages of multimodal sensing with enhanced sensitivity, specificity, and robustness. The advances in fabrication techniques were then discussed, with particular emphasis on printable strategies that facilitate heterogeneous material integration and micro/nanoscale patterning. Moreover, artificial intelligence-driven data processing for on-device decision-making was discussed. Representative applications were then presented in healthcare monitoring, environment detection, and food safety tracking. Finally, current challenges related to material compatibility, data heterogeneity, device scalability, and regulatory barriers were proposed with possible strategies toward fully autonomous and intelligent biosensing systems.
- 22 April 2026
- Published by OAE Publishing Inc. in Soft Science
- Vol. 6 (2)
Open AccessMultimodal biosensing platforms for sensor-computing integration towards intelligent healthcare
Integrated multimodal biosensing platforms are transforming the landscape of bioanalytical technologies by enabling real-time, high-resolution, and multifunctional detection of physiological and environmental biomarkers. This review summarizes the evolution from traditional single-modal biosensors to advanced multimodal systems that unify diverse sensing modalities with computation and storage functionalities. The introduction on the transduction mechanisms of different biosensors and the representative biomarkers was first provided, highlighting the advantages of multimodal sensing with enhanced sensitivity, specificity, and robustness. The advances in fabrication techniques were then discussed, with particular emphasis on printable strategies that facilitate heterogeneous material integration and micro/nanoscale patterning. Moreover, artificial intelligence-driven data processing for on-device decision-making was discussed. Representative applications were then presented in healthcare monitoring, environment detection, and food safety tracking. Finally, current challenges related to material compatibility, data heterogeneity, device scalability, and regulatory barriers were proposed with possible strategies toward fully autonomous and intelligent biosensing systems.
- Open Access
- 25 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Compact and low mutual coupling 4 × 4 wideband MIMO antenna design for 5G millimeter-wave applications
This paper presents a wideband 4 × 4 Multiple-Input-Multiple-Output (MIMO) antenna system operating within the 5G millimeter-wave (mmWave) Frequency Range 2 (FR2). The design targets enhanced mobile broadband (eMBB) applications and features four orthogonally arranged Greek cross-shaped slot antenna (GCSA) elements fed by microstrip lines to effectively reduce mutual coupling and ensure high isolation. Circular edges on the radiating elements are introduced to enhance the impedance bandwidth, while a strategically placed quadrilateral slot in the ground plane optimizes the radiation characteristics. The antenna is fabricated on a Rogers RT/Duroid 4003C substrate (ε r = 3.55, thickness = 0.8 mm), resulting in a compact 40 × 40 × 0.8 mm 3 structure. The proposed MIMO system achieves a measured impedance bandwidth of approximately 8 GHz, spanning 24 to 32 GHz at |S 11 |≤ − 10 dB, with a peak gain of 6 dBi at 27.5 GHz. The antenna exhibits directional radiation patterns perpendicular to the MIMO plane, yielding mutual coupling levels of − 25 dB and − 20 dB at 25 GHz and 29 GHz, respectively. Additionally, the design demonstrates excellent MIMO performance with an Envelope Correlation Coefficient (ECC) < 0.001 and Diversity Gain (DG) ~ 10 dB across the 23.93–31.18 GHz operational band. A comprehensive evaluation of scattering parameters, surface currents, radiation patterns, specific absorption rate (SAR), and diversity metrics confirms the robustness of the proposed design. Prototype measurements closely match the simulated results, validating the antenna’s suitability for 5G millimeter-wave communication systems.
- 25 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessCompact and low mutual coupling 4 × 4 wideband MIMO antenna design for 5G millimeter-wave applications
This paper presents a wideband 4 × 4 Multiple-Input-Multiple-Output (MIMO) antenna system operating within the 5G millimeter-wave (mmWave) Frequency Range 2 (FR2). The design targets enhanced mobile broadband (eMBB) applications and features four orthogonally arranged Greek cross-shaped slot antenna (GCSA) elements fed by microstrip lines to effectively reduce mutual coupling and ensure high isolation. Circular edges on the radiating elements are introduced to enhance the impedance bandwidth, while a strategically placed quadrilateral slot in the ground plane optimizes the radiation characteristics. The antenna is fabricated on a Rogers RT/Duroid 4003C substrate (ε r = 3.55, thickness = 0.8 mm), resulting in a compact 40 × 40 × 0.8 mm 3 structure. The proposed MIMO system achieves a measured impedance bandwidth of approximately 8 GHz, spanning 24 to 32 GHz at |S 11 |≤ − 10 dB, with a peak gain of 6 dBi at 27.5 GHz. The antenna exhibits directional radiation patterns perpendicular to the MIMO plane, yielding mutual coupling levels of − 25 dB and − 20 dB at 25 GHz and 29 GHz, respectively. Additionally, the design demonstrates excellent MIMO performance with an Envelope Correlation Coefficient (ECC) < 0.001 and Diversity Gain (DG) ~ 10 dB across the 23.93–31.18 GHz operational band. A comprehensive evaluation of scattering parameters, surface currents, radiation patterns, specific absorption rate (SAR), and diversity metrics confirms the robustness of the proposed design. Prototype measurements closely match the simulated results, validating the antenna’s suitability for 5G millimeter-wave communication systems.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 131445-131459
Comparative Study of Narrowband and UWB Microwave Sensor Performance for Non-Invasive Blood Clot-Related Dielectric Change Detection
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 131445-131459
Open AccessComparative Study of Narrowband and UWB Microwave Sensor Performance for Non-Invasive Blood Clot-Related Dielectric Change Detection
- Open Access
- 3 October 2025
- Published by Springer Nature in Research Square
Machine Learning-Enhanced Non-Invasive Glucose Monitoring via a Compact Microwave CSRR Resonator Sensor
This paper presents a new, compact shape of a planar microwave resonator sensor for non-invasive blood glucose monitoring, enabling effective diabetes management. The proposed sensor is based on four cells of compact as irregularly curved Coupled Split Ring Resonators (CSRRs) printed on an affordable FR4 dielectric substrate. It functions by leveraging the interaction between biological tissues and microwave signals to detect glucose levels accurately. By transmitting microwave signals through the body and analyzing the S-parameters, the sensor identifies changes in the dielectric properties of blood, enabling the measurement of glucose concentrations. The magnitude and phase of S-parameters play a crucial role in providing a comprehensive analysis of glucose-induced variations. To validate the sensor’s performance, simulations use a phantom finger model, with laboratory data employed to verify these results, accounting for potential experimental variability. Sensitivity testing is conducted using glucose solutions with concentrations from 0 mg/dL to 350 mg/dL. Additionally, machine learning (ML) techniques are integrated to analyze sensor data, enhance glucose detection accuracy. The sensor can adapt to individual differences and environmental factors, improving the overall accuracy and reliability of the glucose monitoring system. Applying classification algorithms and signal processing methods, such as Discrete Wavelet Transform (DWT) decomposition, is used to classify microwave signals according to glucose levels more accurately. The integration of DWT significantly improves classification accuracy, achieving an 80% success rate across different glucose concentrations. The CSRR sensor design demonstrates a strong interaction between glucose samples and electromagnetic fields, resulting in a sensitivity of 10 MHz/(mg/dL) and 3dB/(mg/dL), alongside excellent detection capabilities.
- 3 October 2025
- Published by Springer Nature in Research Square
Open AccessMachine Learning-Enhanced Non-Invasive Glucose Monitoring via a Compact Microwave CSRR Resonator Sensor
This paper presents a new, compact shape of a planar microwave resonator sensor for non-invasive blood glucose monitoring, enabling effective diabetes management. The proposed sensor is based on four cells of compact as irregularly curved Coupled Split Ring Resonators (CSRRs) printed on an affordable FR4 dielectric substrate. It functions by leveraging the interaction between biological tissues and microwave signals to detect glucose levels accurately. By transmitting microwave signals through the body and analyzing the S-parameters, the sensor identifies changes in the dielectric properties of blood, enabling the measurement of glucose concentrations. The magnitude and phase of S-parameters play a crucial role in providing a comprehensive analysis of glucose-induced variations. To validate the sensor’s performance, simulations use a phantom finger model, with laboratory data employed to verify these results, accounting for potential experimental variability. Sensitivity testing is conducted using glucose solutions with concentrations from 0 mg/dL to 350 mg/dL. Additionally, machine learning (ML) techniques are integrated to analyze sensor data, enhance glucose detection accuracy. The sensor can adapt to individual differences and environmental factors, improving the overall accuracy and reliability of the glucose monitoring system. Applying classification algorithms and signal processing methods, such as Discrete Wavelet Transform (DWT) decomposition, is used to classify microwave signals according to glucose levels more accurately. The integration of DWT significantly improves classification accuracy, achieving an 80% success rate across different glucose concentrations. The CSRR sensor design demonstrates a strong interaction between glucose samples and electromagnetic fields, resulting in a sensitivity of 10 MHz/(mg/dL) and 3dB/(mg/dL), alongside excellent detection capabilities.
- Open Access
- 7 June 2025
- Published by Springer Nature in Discover Electronics
- Vol. 2 (1) , 1-19
Multiband printed rectenna for radio frequency energy harvesting (RF-EH)
- 7 June 2025
- Published by Springer Nature in Discover Electronics
- Vol. 2 (1) , 1-19
Open AccessMultiband printed rectenna for radio frequency energy harvesting (RF-EH)
- Open Access
- 9 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-22
Noninvasive blood glucose monitoring using a dual band microwave sensor with machine learning
The potential for continuous non-invasive blood glucose monitoring has attracted a lot of interest in the field of medical diagnostics. This paper provides a new shape of a dual-band bandpass filter (DBBPF) acting as a microwave transmission line sensor for continuous non-invasive blood glucose monitoring operating at 2.45 and 5.2 GHz. The proposed system uses the interaction between biological tissues and microwave signals to correctly assess blood glucose levels. The proposed dual-band bandpass filter (DBBPF), comprises three split ring resonator (SRR) cells with different dimensions. It is designed to operate as a sensor with improved sensitivity, compact dimensions, and a high-quality factor. It also ensures a reasonable bandwidth for lower and higher bands of 8.6 and 2%, respectively in the industrial, scientific, medical band, and the wireless local area network (ISM and WLAN) Bands. A dual-band filter enhances measurement sensitivity and specificity by targeting specific frequency ranges where glucose exhibits distinctive dielectric responses, thereby providing redundant data points for accurate glucose level determination. Glucose concentrations can be evaluated by measuring the changes in the dielectric properties of blood by sending microwave waves through the body and assessing the collected S-parameter signals. The measurement parameters encompass the reflection, phase, magnitude, as well as transmission parameters. This yields multiple evaluations of the glucose-induced alterations. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. Machine learning models are employed to analyze the sensor data, improving the accuracy of diabetes detection. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. A Cole-Cole model, implemented using MATLAB, is utilized for the phantom finger model. The main results reveal the success of the proposed transmission-based microwave glucose sensing, with a remarkable sensitivity of 1 ~ 1.5 dB for glucose level change up to 200 mg/dL.
- 9 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-22
Open AccessNoninvasive blood glucose monitoring using a dual band microwave sensor with machine learning
The potential for continuous non-invasive blood glucose monitoring has attracted a lot of interest in the field of medical diagnostics. This paper provides a new shape of a dual-band bandpass filter (DBBPF) acting as a microwave transmission line sensor for continuous non-invasive blood glucose monitoring operating at 2.45 and 5.2 GHz. The proposed system uses the interaction between biological tissues and microwave signals to correctly assess blood glucose levels. The proposed dual-band bandpass filter (DBBPF), comprises three split ring resonator (SRR) cells with different dimensions. It is designed to operate as a sensor with improved sensitivity, compact dimensions, and a high-quality factor. It also ensures a reasonable bandwidth for lower and higher bands of 8.6 and 2%, respectively in the industrial, scientific, medical band, and the wireless local area network (ISM and WLAN) Bands. A dual-band filter enhances measurement sensitivity and specificity by targeting specific frequency ranges where glucose exhibits distinctive dielectric responses, thereby providing redundant data points for accurate glucose level determination. Glucose concentrations can be evaluated by measuring the changes in the dielectric properties of blood by sending microwave waves through the body and assessing the collected S-parameter signals. The measurement parameters encompass the reflection, phase, magnitude, as well as transmission parameters. This yields multiple evaluations of the glucose-induced alterations. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. Machine learning models are employed to analyze the sensor data, improving the accuracy of diabetes detection. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. A Cole-Cole model, implemented using MATLAB, is utilized for the phantom finger model. The main results reveal the success of the proposed transmission-based microwave glucose sensing, with a remarkable sensitivity of 1 ~ 1.5 dB for glucose level change up to 200 mg/dL.
- 16 April 2025
- Published by Springer Nature
- p. 421-432
Design an Antenna Array for Radio Frequency Energy Harvesting System (RF-EH) to Feed Low Power Sensors
- 16 April 2025
- Published by Springer Nature
- p. 421-432
Design an Antenna Array for Radio Frequency Energy Harvesting System (RF-EH) to Feed Low Power Sensors
- Open Access
- 15 April 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 250
Blood Glucose Monitoring Biosensor Based on Multiband Split-Ring Resonator Monopole Antenna
This paper introduces a novel-shaped, compact, multiband monopole antenna sensor incorporating an irregular curved split-ring resonator (SRR) design for non-invasive, continuous monitoring of human blood glucose levels (BGL). The sensor operates at multiple resonance frequencies: 0.94, 1.5, 3, 4.6, and 6.3 GHz, achieving coefficient reflection impedance bandwidths ≤ −10 dB of 4%, 1%, 3.5%, 65%, and 50%, respectively. Additionally, novel shapes of two SRR metamaterial cells create notches at 1.7 GHz and 4.4 GHz. The antenna is fabricated on an economical FR4 substrate with compact dimensions of 35 × 50 × 1.6 mm3. The sensor’s performance is evaluated using 3D electromagnetic software, incorporating a human finger phantom model and applying the Cole–Cole model to mimic the blood layer’s sensitivity to blood glucose variations. The phantom model is positioned at different angles relative to the biosensor to detect frequency shifts corresponding to different glucose levels. Experimental validation involves placing a real human finger around the sensor to measure resonant frequency, magnitude, and phase changes. The fabricated sensor demonstrates a superior sensitivity of 24 MHz/mg/dL effectiveness compared to existing methods. This emphasizes its potential for practical, non-invasive glucose monitoring applications.
- 15 April 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 250
Open AccessBlood Glucose Monitoring Biosensor Based on Multiband Split-Ring Resonator Monopole Antenna
This paper introduces a novel-shaped, compact, multiband monopole antenna sensor incorporating an irregular curved split-ring resonator (SRR) design for non-invasive, continuous monitoring of human blood glucose levels (BGL). The sensor operates at multiple resonance frequencies: 0.94, 1.5, 3, 4.6, and 6.3 GHz, achieving coefficient reflection impedance bandwidths ≤ −10 dB of 4%, 1%, 3.5%, 65%, and 50%, respectively. Additionally, novel shapes of two SRR metamaterial cells create notches at 1.7 GHz and 4.4 GHz. The antenna is fabricated on an economical FR4 substrate with compact dimensions of 35 × 50 × 1.6 mm3. The sensor’s performance is evaluated using 3D electromagnetic software, incorporating a human finger phantom model and applying the Cole–Cole model to mimic the blood layer’s sensitivity to blood glucose variations. The phantom model is positioned at different angles relative to the biosensor to detect frequency shifts corresponding to different glucose levels. Experimental validation involves placing a real human finger around the sensor to measure resonant frequency, magnitude, and phase changes. The fabricated sensor demonstrates a superior sensitivity of 24 MHz/mg/dL effectiveness compared to existing methods. This emphasizes its potential for practical, non-invasive glucose monitoring applications.
- 8 February 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 387
Circularly polarized flexible antennas for near field breast cancer sensing in a smart bra monitoring system
- 8 February 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 387
Circularly polarized flexible antennas for near field breast cancer sensing in a smart bra monitoring system