Janez Rozman
Research Subjects
Research Interests
Janez Rozman has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Polona Pečlin
Division of Gynaecology and Obstetrics, University Medical Centre Ljubljana, Šlajmerjeva 3 and Zaloška 7, Ljubljana, Republic of Slovenia
4 shared publicationsBojan Zorko
Veterinary Faculty, Gerbiceva 60, 1000 Ljubljana, Republic of Slovenia
3 shared publicationsM. Bunc
University of Ljubljana, School of Medicine, Institute of Pathophysiology, Zaloška 4, 1000 Ljubljana, Republic of Slovenia
3 shared publicationsSamo Ribarič
Institute of Pathophysiology, Faculty of Medicine, University of Ljubljana, Ljubljana, Republic of Slovenia
3 shared publicationsAlenka Vidmar
2 shared publicationsB. Zorko
University of Ljubljana Veterinary faculty
2 shared publications
Latest Publications
- 10 December 2021
- Published by Institute of Metals and Technology in Materiali in tehnologije
- Vol. 55 (6) , 809–817
English MODULATION OF MELATONIN SECRETION WITH TRANSCUTANEOUS AURICULAR NERVE STIMULATION: A CASE STUDY
The main study objective was to test the hypothesis that selective electrical transcutaneous auricular nerve stimulation (tANS) under forenoon daylight conditions induces melatonin secretion in a 64-year-old male patient with angina pectoris, hypercholesterolomy and coronary artery disease, assuming that it has beneficial effects on accompanied insomnia (Regensburg Insomnia Scale (RIS) = 22 points, the total score ranges from 0 to 40). Silicone stimulation plugs, with two platinum stimulating cathodes each, were inserted into the left and right external ears. Afterwards, one-second-long pulse trains of cathodic, biphasic and current regulated stimulating pulses at stimulating charge density Cd of 50.88 µC/cm2 and frequency of 25 Hz, were delivered for 30 min to selected sites at the upper and lower part of the left and right Cymba Conchae (CC), respectively. The common anode was attached to the neck. The time gap between the pulse trains was measured by the patient using a tactile sensor and was about 250 ms. The results showed that selective tANS under forenoon daylight conditions increased melatonin saliva levels in all the trials accomplished in a patient. Precisely, the lowest increase was obtained in trials with lower right (LR) CC, while the highest increase was obtained in upper-right (UR) CC trials.
- 10 December 2021
- Published by Institute of Metals and Technology in Materiali in tehnologije
- Vol. 55 (6) , 809–817
English MODULATION OF MELATONIN SECRETION WITH TRANSCUTANEOUS AURICULAR NERVE STIMULATION: A CASE STUDY
The main study objective was to test the hypothesis that selective electrical transcutaneous auricular nerve stimulation (tANS) under forenoon daylight conditions induces melatonin secretion in a 64-year-old male patient with angina pectoris, hypercholesterolomy and coronary artery disease, assuming that it has beneficial effects on accompanied insomnia (Regensburg Insomnia Scale (RIS) = 22 points, the total score ranges from 0 to 40). Silicone stimulation plugs, with two platinum stimulating cathodes each, were inserted into the left and right external ears. Afterwards, one-second-long pulse trains of cathodic, biphasic and current regulated stimulating pulses at stimulating charge density Cd of 50.88 µC/cm2 and frequency of 25 Hz, were delivered for 30 min to selected sites at the upper and lower part of the left and right Cymba Conchae (CC), respectively. The common anode was attached to the neck. The time gap between the pulse trains was measured by the patient using a tactile sensor and was about 250 ms. The results showed that selective tANS under forenoon daylight conditions increased melatonin saliva levels in all the trials accomplished in a patient. Precisely, the lowest increase was obtained in trials with lower right (LR) CC, while the highest increase was obtained in upper-right (UR) CC trials.
- 31 May 2021
- Published by Institute of Metals and Technology in Materiali in tehnologije
- Vol. 55 (3) , 387–399
SHORT-TERM EFFECTS OF SELECTIVE TRANSCUTANEOUS AURICULAR-NERVE STIMULATION MEASURED IN A SUBJECT WITH ANGINA PECTORIS
We have measured the short-term effects of selective, transcutaneous, auricular-nerve stimulation (tANS) on the heart function, respiratory function, thermal function and galvanic skin response in a patient with angina pectoris with respect to four predefined sites on the left and right cymba concae (CC). The tANS involved the use of a train of monopolar, current, biphasic pulses composed of rectangular cathodic ic and anodic phases ia and globule-like platinum stimulating electrodes. The parameters of the stimulating pulses were as follows: frequency f = 45.5 Hz, cathodic phase width tc = 200 µs, anodic phase width ta = 200 µs, interphase delay d =180 µs, pulse-train duration 2.0 s and time gap between pulse trains 1.0 s. The results show that tANS at predefined sites on the CC produce measurable effects on the assessed vital functions. In conclusion, tANS witbih an increased number of channels, has the potential to be used in the treatment of certain disorders.
- 31 May 2021
- Published by Institute of Metals and Technology in Materiali in tehnologije
- Vol. 55 (3) , 387–399
SHORT-TERM EFFECTS OF SELECTIVE TRANSCUTANEOUS AURICULAR-NERVE STIMULATION MEASURED IN A SUBJECT WITH ANGINA PECTORIS
We have measured the short-term effects of selective, transcutaneous, auricular-nerve stimulation (tANS) on the heart function, respiratory function, thermal function and galvanic skin response in a patient with angina pectoris with respect to four predefined sites on the left and right cymba concae (CC). The tANS involved the use of a train of monopolar, current, biphasic pulses composed of rectangular cathodic ic and anodic phases ia and globule-like platinum stimulating electrodes. The parameters of the stimulating pulses were as follows: frequency f = 45.5 Hz, cathodic phase width tc = 200 µs, anodic phase width ta = 200 µs, interphase delay d =180 µs, pulse-train duration 2.0 s and time gap between pulse trains 1.0 s. The results show that tANS at predefined sites on the CC produce measurable effects on the assessed vital functions. In conclusion, tANS witbih an increased number of channels, has the potential to be used in the treatment of certain disorders.
- 15 October 2019
- Published by Institute of Metals and Technology in Materiali in tehnologije
- Vol. 53 (5) , 627-635
A system for the multi-channel transcutaneous stimulation of the auricular nerve
- 15 October 2019
- Published by Institute of Metals and Technology in Materiali in tehnologije
- Vol. 53 (5) , 627-635
A system for the multi-channel transcutaneous stimulation of the auricular nerve
- 15 March 2017
- Published by Springer Nature
- p. 110-113
Fabrication and testing of a multi-electrode spiral nerve cuff
- 15 March 2017
- Published by Springer Nature
- p. 110-113
Fabrication and testing of a multi-electrode spiral nerve cuff
- Open Access
- 1 January 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-10
Alternative Paradigm of Selective Vagus Nerve Stimulation Tested on an Isolated Porcine Vagus Nerve
Alternative paradigm for spatial and fibre-type selective vagus nerve stimulation (VNS) was developed using realistic structural topography and tested in an isolated segment of a porcine cervical left vagus nerve (LVN). A spiral cuff (cuff) containing a matrix of ninety-nine electrodes was developed for selective VNS. A quasitrapezoidal stimulating pulse (stimulus) was applied to the LVN via an appointed group of three electrodes (triplet). The triplet and stimulus were configured to predominantly stimulate the B-fibres, minimizing stimulation of the A-fibres and by-passing the stimulation of the C-fibres. To assess which fibres made the most probable contribution to the neural response (NR) during selective VNS, the distribution of conduction velocity (CV) within the LVN was considered. Experimental testing of the paradigm showed the existence of certain parameters and waveforms of the stimulus, for which the contribution of the A-fibres to the NR was slightly reduced and that of the B-fibres was slightly enlarged. The cuff provided satisfactory fascicle discrimination in selective VNS as well as satisfactory fascicle discrimination during NR recording. However, in the present stage of development, fibre-type VNS remained rather limited.
- 1 January 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-10
Open AccessAlternative Paradigm of Selective Vagus Nerve Stimulation Tested on an Isolated Porcine Vagus Nerve
Alternative paradigm for spatial and fibre-type selective vagus nerve stimulation (VNS) was developed using realistic structural topography and tested in an isolated segment of a porcine cervical left vagus nerve (LVN). A spiral cuff (cuff) containing a matrix of ninety-nine electrodes was developed for selective VNS. A quasitrapezoidal stimulating pulse (stimulus) was applied to the LVN via an appointed group of three electrodes (triplet). The triplet and stimulus were configured to predominantly stimulate the B-fibres, minimizing stimulation of the A-fibres and by-passing the stimulation of the C-fibres. To assess which fibres made the most probable contribution to the neural response (NR) during selective VNS, the distribution of conduction velocity (CV) within the LVN was considered. Experimental testing of the paradigm showed the existence of certain parameters and waveforms of the stimulus, for which the contribution of the A-fibres to the NR was slightly reduced and that of the B-fibres was slightly enlarged. The cuff provided satisfactory fascicle discrimination in selective VNS as well as satisfactory fascicle discrimination during NR recording. However, in the present stage of development, fibre-type VNS remained rather limited.
- 1 December 2012
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 40 (8) , 647-653
Evaluation of surgical treatment in mandibular condyle fractures
- 1 December 2012
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 40 (8) , 647-653
Evaluation of surgical treatment in mandibular condyle fractures
- Open Access
- 1 June 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (6) , 923-932
Gene Expression Profiling of Rat Fetuses Exposed to 2-Dimensional Ultrasound
Objectives This study evaluated the possible effects of ultrasound (US) on gene expression in brain tissue of rat embryos. Methods Four groups (n = 5 each) of pregnant Wistar Han rats were exposed to US for different durations (55, 100, 145, and 195 seconds) via a multifrequency transducer in the 2‐dimensional imaging mode with a pulse duration of 1.29 microseconds, a pulse repetition frequency of 1 kHz, and a derated spatial‐peak pulse‐average intensity of 222.4 W/cm2 on day 5, 9, 7, or 13 of gestation. Gene expression profiling was performed in fetal brain tissue (n = 5 per group) by quantitative reverse transcription–polymerase chain reaction arrays. Results The results indicated substantial alterations in gene expression. The most differentially expressed genes were Adamts5, Gadd45a, Npy2r, and Chrna1, which are implicated in important developmental signaling pathways. Conclusions On the basis of our findings, routine short US examinations for monitoring fetal development are not contraindicated, but prolonged exposures should be used only when needed to obtain important diagnostic information.
- 1 June 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (6) , 923-932
Open AccessGene Expression Profiling of Rat Fetuses Exposed to 2-Dimensional Ultrasound
Objectives This study evaluated the possible effects of ultrasound (US) on gene expression in brain tissue of rat embryos. Methods Four groups (n = 5 each) of pregnant Wistar Han rats were exposed to US for different durations (55, 100, 145, and 195 seconds) via a multifrequency transducer in the 2‐dimensional imaging mode with a pulse duration of 1.29 microseconds, a pulse repetition frequency of 1 kHz, and a derated spatial‐peak pulse‐average intensity of 222.4 W/cm2 on day 5, 9, 7, or 13 of gestation. Gene expression profiling was performed in fetal brain tissue (n = 5 per group) by quantitative reverse transcription–polymerase chain reaction arrays. Results The results indicated substantial alterations in gene expression. The most differentially expressed genes were Adamts5, Gadd45a, Npy2r, and Chrna1, which are implicated in important developmental signaling pathways. Conclusions On the basis of our findings, routine short US examinations for monitoring fetal development are not contraindicated, but prolonged exposures should be used only when needed to obtain important diagnostic information.
- 1 October 2011
- Published by Elsevier in Respiratory Medicine
- Vol. 105, S44-S49
Differences between bisoprolol and carvedilol in patients with chronic heart failure and chronic obstructive pulmonary disease: a randomized trial
- 1 October 2011
- Published by Elsevier in Respiratory Medicine
- Vol. 105, S44-S49
Differences between bisoprolol and carvedilol in patients with chronic heart failure and chronic obstructive pulmonary disease: a randomized trial
- 28 February 2010
- Published by Elsevier in Medical Hypotheses
- Vol. 74 (2) , 362-365
Tremor amplitude and tremor frequency variability in Parkinson’s disease is dependent on activity and synchronisation of central oscillators in basal ganglia
- 28 February 2010
- Published by Elsevier in Medical Hypotheses
- Vol. 74 (2) , 362-365
Tremor amplitude and tremor frequency variability in Parkinson’s disease is dependent on activity and synchronisation of central oscillators in basal ganglia
- 1 January 2010
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 20 (6) , 339-348
Evaluation of NiTi Superelastic Retraction Coil Springs for orthodontic tooth movement in rats
The purpose of this investigation was to assess mechanical properties of Superelastic Retraction Coil Springs for orthodontic use. To reach a goal, a test frame, comprising measuring force transducers was developed. To perform metallographic analyses
- 1 January 2010
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 20 (6) , 339-348
Evaluation of NiTi Superelastic Retraction Coil Springs for orthodontic tooth movement in rats
The purpose of this investigation was to assess mechanical properties of Superelastic Retraction Coil Springs for orthodontic use. To reach a goal, a test frame, comprising measuring force transducers was developed. To perform metallographic analyses