Sun-Joon Byun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Study on Improvement of Performance by Wave Form Cathode Channels in a PEM Fuel Cell

    by Sun-Joon Byun, Zhen Huan Wang, Jun Son, Dong-Kurl Kwak, Young-Chul Kwon

    We propose a wave-like design on the surface of cathode channels (wave form cathode channels) to improve oxidant delivery to gas diffusion layers (GDLs). We performed experiments using proton-exchange membrane fuel cells (PEMFCs) combined with wave form surface design on cathodes. We varied the factors of the distance between wave-bumps (the adhesive distance, AD), and the size of the wave-bumps (the expansion ratio, ER). The ADs are three, four, and five times the size of the half-circle bump’s radius, and the ERs are two-thirds, one-half, and one-third of the channel’s height. We evaluated the performances of the fuel cells, and compared the current-voltage (I-V) relations. For comparison, we prepared PEMFCs with conventional flat-surfaced oxygen channels. Our aim in this work is to identify fuel cell operation by modifying the surface design of channels, and ultimately to find the optimal design of cathode channels that will maximize fuel cell performance.


  • Open Access

    Experimental Study on Improvement of Performance by Wave Form at Cathode Channels in PEM Fuel Cell

    by Sun-Joon Byun, Zhen Huan Wang, Jun Son, Young-Chul Kwon, Dong-Kurl Kwak

    We propose a wave-like design on the surface of cathode channels (wave form cathode channels) to improve oxidant delivery to gas diffusion layers (GDLs) [1-2]. We performed experiments using PEMFCs combined with wave form surface design on cathodes. We varied the factors of the distance between wave-bumps (the Adhesive distance, AD), and the size of the wave-bumps (the Expansion ratio, ER). The ADs are 3, 4, and 5 times the size of the half-circle bump’s radius, and the ERs are 1/1.5, 1/2, and 1/3 times the channel’s height. We evaluated the performances of the fuel cells, and compared the current-voltage (I-V) relations. For comparison, we prepared PEMFCs with conventional flat-surfaced oxygen channels. Our aim in this work is to identify fuel cell operation by modifying the surface design of channels, and ultimately to find the optimal design of cathode channels that will maximize fuel cell performance.

  • Open Access

    Experimental Study on the Cycle Performance Characteristics of the CO2 Heat Pump System under the Cooling Condition

    by Hee Jeong Kang, Zhen Huan Wang, Jun Son, Sun-Joon Byun, Young-Chul Kwon

    Developing high performance HVAC system using natural refrigerants including carbon dioxide (CO2) has been important in respect of environmental preservation and associated technologies. Thus studies to optimize the HVAC (heating ventilation air conditioner) system using natural refrigerants through clarifying the cycle performance characteristics are necessary. The CO2 heat pump system using air and water sources was consisted to examine its performance characteristics, and by varying conditions of several factors that affect or characterize the system performance like the amount of refrigerant charge, EEV (electronic expansion valve) opening, and internal heat exchanger under cooling mode. The performance characteristics of CO2 heat pump system were tested by using an air enthalpy calorimeter. In the case of the CO2 heat pump system without internal heat exchanger, the opening of #3 EEV and #4 EEV was 60% and refrigerant charge amount was 5,600g. However, in the case of that with internal heat exchanger, the best performance was obtained when the opening of #2 EEV is 20%. From the present studies, it was observed that the performance variation and operational characteristics of the CO2 heat pump system were affected by design factors like refrigerant charge amount, EEV opening, and internal heat exchanger and thereby, the configuration on an optimal operation conditions of the system was enabled.

  • Open Access

    Experimental Study on the Heat Transfer Characteristics of the Enhanced Fin-Tube Heat Exchanger Applied a Coiled Turbulator

    by Sun-Joon Byun, Sang-Jae Lee, Jae-Min Cha, Zhen-Huan Wang, Young-Chul Kwon

    This study presents the comparison of heat transfer capacity and pressure drop characteristics between a basic fin-tube heat exchanger and a modified heat exchanger with the structural change of branch tubes and coiled turbulators. All experiments were carried out using an air-enthalpy type calorimeter based on the method described in ASHRAE standards, under heat exchanger experimental conditions. 14 different kinds of heat exchangers were used for the experiment. Cooling and heating capacities of the turbulator heat exchanger were excellent, compared to the basic one. As the insertion ratio of the coiled turbulator and the number of row increased, the heat transfer performance increased. However, the capacity per unit area was more effective in 4 rows than 6 rows, and the cooling performance of the 6 row turbulator heat exchanger (100% turbulator insert ratio) was down to about 6% than that of 4 row one. As the water flow rate and the turbulator insertion ratio increased, the pressure drop of the water side increased. This trend was more pronounced in 6 rows. In the cooling condition, the pressure drop on the air side was slightly increased due to the generation of condensed water, but was insignificant under the heating condition. The power consumption of the pump was more affected by the water flow rate than the coiled turbulator. The equivalent hydraulic diameter of a tube by the turbulator was reduced and then the heat transfer performance was improved. Thus, the tube diameter was smaller, the heat flux was better.

  • Open Access

    Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    by Jae-Ki Byun, Dong-Hwa Jeong, Young-Don Choi, Jong-Keun Shin

    In the present study, a fuel cell driven ground source heat pump (GSHP) system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP) of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.


  • Open Access

    Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature

    by Jae-Ki Byun, Young-Don Choi, Jong-Keun Shin, Myung-Ho Park, Dong-Kurl Kwak

    In the present study, we have developed an optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in a group energy apartment. Heating load variation of a group energy apartment building according to the outdoor air temperature was predicted by a correlation obtained from calorimetry measurements of all households in the apartment building. Supply water temperature and mass flow rate were simultaneously controlled to minimize the heat loss rate through the distribution pipe line. A group heating apartment building located in Hwaseong city, Korea, which has 1473 households, was selected as the object building to test the present heat supply algorithm. Compared to the original heat supply system, the present system adopting the proposed control algorithm reduced the heat loss rate by 10.4%.