RCRahul Chib

Rahul Chib

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rahul Chib has a total of 78 co-authors. Here are the top co-authors by number of shared publications:

  • Zygmunt Gryczynski

    Institute of Molecular Medicine, Center for Fluorescence Technologies and Nanomedicine, University of North Texas Health Science Center, Fort Worth, TX 76107, USA

    14 shared publications
  • Sangram Raut

    Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX 76129, USA.

    13 shared publications
  • Ignacy Gryczynski

    Department of Cell Biology and Immunology, Center for Fluorescence Technologies and Nanomedicine, University of North Texas Health Science Center, Fort Worth, TX, USA

    10 shared publications
  • Ignacy Gryczynski

    University of North Texas Health Science Center

    9 shared publications
  • Julian Borejdo

    Institute of Molecular Medicine, Center for Fluorescence Technologies and Nanomedicine, University of North Texas Health Science Center, Fort Worth, TX 76107, USA

    6 shared publications
  • Maria G. Corradini

    Department of Food Science, University of Guelph, Guelph, Canada

    4 shared publications

Latest Publications

  • Tryptophan Fluorescence Yields and Lifetimes as a Probe of Conformational Changes in Human Glucokinase

    by Bogumil Zelent, Chris Bialas, Ignacy Gryczynski, Pan Chen, Rahul Chib, Karina Lewerissa, Maria G. Corradini, Richard D. Ludescher, Jane M. Vanderkooi, Franz M. Matschinsky

    Five variants of glucokinase (ATP-D-hexose-6-phosphotransferase, EC 2.7.1.1) including wild type and single Trp mutants with the Trp residue at positions 65, 99, 167 and 257 were prepared. The fluorescence of Trp in all locations studied showed intensity changes when glucose bound, indicating that conformational change occurs globally over the entire protein. While the fluorescence quantum yield changes upon glucose binding, the enzyme’s absorption spectra, emission spectra and fluorescence lifetimes change very little. These results are consistent with the existence of a dark complex for excited state Trp. Addition of glycerol, L-glucose, sucrose, or trehalose increases the binding affinity of glucose to the enzyme and increases fluorescence intensity. The effect of these osmolytes is thought to shift the protein conformation to a condensed, high affinity form. Based upon these results, we consider the nature of quenching of the Trp excited state. Amide groups are known to quench indole fluorescence and amides of the polypeptide chain make interact with excited state Trp in the relatively unstructured, glucose-free enzyme. Also, removal of water around the aromatic ring by addition of glucose substrate or osmolyte may reduce the quenching.


  • Photophysical Properties of Allura Red for Monitoring Quality of Foods and Pharmaceuticals

    by Bogumil Zelent, Rahul Chib, Sarah Waxman, Alexia Ciarfella, Maria Corradini, Richard D. Ludescher


  • Edible Luminescent Probes as Sensors of Food Quality:Identification and Selection

    by Rahul Chib, Bogumil Zelent, Yan Wang, An Le, Maria G. Corradini, Richard D. Ludescher

  • Fluorescence lifetime imaging with time-gated detection of hyaluronidase using a long lifetime azadioxatriangulenium (ADOTA) fluorophore

    by Rahul Chib, Sebastian Requena, Mark Mummert, Yuri M Strzhemechny, Ignacy Gryczynski, Julian Borejdo, Zygmunt Gryczynski, Rafal Fudala

    A fluorescence lifetime imaging probe with a long lifetime was used in combination with time-gating for the detection of hyaluronidase using hyaluronic acid as the probe template. This probe was developed by heavily labeling hyaluronic acid with long lifetime azadioxatriangulenium fluorophores (ADOTA). We used this probe to image hyaluronidase produced by DU-145 prostate cancer cells.


  • Fluorescent biosensor for the detection of hyaluronidase: intensity-based ratiometric sensing and fluorescence lifetime-based sensing using a long lifetime azadioxatriangulenium (ADOTA) fluorophore

    by Rahul Chib, Mark Mummert, Ilkay Bora, Bo W. Laursen, Sunil Shah, Robert Pendry, Ignacy Gryczynski, Julian Borejdo, Zygmunt Gryczynski, Rafal Fudala

    In this report, we have designed a rapid and sensitive, intensity-based ratiometric sensing as well as lifetime-based sensing probe for the detection of hyaluronidase activity. Hyaluronidase expression is known to be upregulated in various pathological conditions. We have developed a fluorescent probe by heavy labeling of hyaluronic acid with a new orange/red-emitting organic azadioxatriangulenium (ADOTA) fluorophore, which exhibits a long fluorescence lifetime (∼20 ns). The ADOTA fluorophore in water has a peak fluorescence lifetime of ∼20 ns and emission spectra centered at 560 nm. The heavily ADOTA-labeled hyaluronic acid (HA-ADOTA) shows a red shift in the peak emission wavelength (605 nm), a weak fluorescence signal, and a shorter fluorescence lifetime (∼4 ns) due to efficient self-quenching and formation of aggregates. In the presence of hyaluronidase, the brightness and fluorescence lifetime of the sample increase with a blue shift in the peak emission to its original wavelength at 560 nm. The ratio of the fluorescence intensity of the HA-ADOTA probe at 560 and 605 nm can be used as the sensing method for the detection of hyaluronidase. The cleavage of the hyaluronic acid macromolecule reduces the energy migration between ADOTA molecules, as well as the degree of self-quenching and aggregation. This probe can be efficiently used for both intensity-based ratiometric sensing as well as fluorescence lifetime-based sensing of hyaluronidase. The proposed method makes it a rapid and sensitive assay, useful for analyzing levels of hyaluronidase in relevant clinical samples like urine or plasma. Scheme showing cleavage of HA-ADOTA probe by hyaluronidase and the change in the emission spectrum of HA-ADOTA probe before and after cleavage by hyaluronidase


  • Rationalizing the Use of Functionalized Poly-Lactic-Co-Glycolic Acid Nanoparticles for Dendritic Cell-Based Targeted Anticancer Therapy

    by Rutika A Kokate, Pankaj Chaudhary, Xiangle Sun, Sanjay I Thamake, Sayantan Maji, Rahul Chib, Jamboor K Vishwanatha, Harlan P Jones

    Background: Delivery of PLGA (poly [D, L-lactide-co-glycolide])-based biodegradable nanoparticles (NPs) to antigen presenting cells, particularly dendritic cells, has potential for cancer immunotherapy. Materials & methods: Using a PLGA NP vaccine construct CpG-NP-Tag (CpG-ODN-coated tumor antigen [Tag] encapsulating NP) prepared using solvent evaporation technique we tested the efficacy of ex vivo and in vivo use of this construct as a feasible platform for immune-based therapy. Results: CpG-NP-Tag NPs were avidly endocytosed and localized in the endosomal compartment of bone marrow-derived dendritic cells. Bone marrow-derived dendritic cells exposed to CpG-NP-Tag NPs exhibited an increased maturation (higher CD80/86 expression) and activation status (enhanced IL-12 secretion levels). In vivo results demonstrated attenuation of tumor growth and angiogenesis as well as induction of potent cytotoxic T-lymphocyte responses. Conclusion: Collectively, results validate dendritic cells stimulatory response to C...


  • Photophysical characterization of anticancer drug valrubicin in rHDL nanoparticles and its use as an imaging agent

    by Sunil Shah, Rahul Chib, Sangram Raut, Jaclyn Bermudez, Nirupama Sabnis, Divya Duggal, Joseph D. Kimball, Andras G. Lacko, Zygmunt Gryczynski, Ignacy Gryczynski


  • Open Access

    Defect-mediated spontaneous emission enhancement of plasmon-coupled CuInS_2 and CuInS_2/ZnS

    by Quinton Rice, Sangram Raut, Rahul Chib, Anderson Hayes, Zygmunt Gryczynski, Ignacy Gryczynski, Young-Kuk Kim, Bagher Tabibi, Jaetae Seo

    The studies of plasmon-coupled excitons at the surface-/interface-, shallow-, and deep-trapped states of copper-indium-disulfide (CIS) with/without zinc-sulfide (ZnS) shell revealed the defect-mediated spontaneous emission enhancement. The PL enhancement with spectral blue-shift of plasmon-coupled excitons in CIS quantum dots (QDs) indicates the large reduction of nonradiative decay at the surface- and shallow-trapped states with strong spectral overlapping. The PL enhancement with spectral red-shift of plasmon-coupled excitons in CIS/ZnS QDs is accredited to the defect-mediated PL enhancement by the higher fractional amplitude at the interface-trapped state around the longer spectral region. The spontaneous emission enhancement of plasmon-coupled CIS QDs were ~2.1, ~2.2, and ~2.8-folds compared to the decay rates of CIS, and those of plasmon-coupled CIS/ZnS QDs were ~24.1, ~32.8, and ~24.9-folds compared to the decay rates of CIS/ZnS at shorter, intermediate, and longer spectral regions due to relatively stable charge carriers and close to the surface plasmon resonance. The PL enhancements of plasmon-coupled CIS at room temperature and 6 K were two-fold and three-fold compared to the integrated CIS PLs, and the PL enhancements of plasmon-coupled CIS/ZnS at room temperature and 6 K were five-fold and eight-fold compared to the integrated CIS/ZnS PLs. The large PL enhancement is attributable to the plasmon-exciton coupling through Coulomb interaction and the local field enhancement. The larger PL enhancement of plasmon-coupled CIS/ZnS compared to that of plasmon-coupled CIS is accredited to the larger spontaneous emission enhancement.


  • Open Access

    Demonstration of FRET in solutions

    by Sunil Shah, Zygmunt Gryczynski, Rahul Chib, Rafal Fudala, Aatmun Baxi, Julian Borejdo, Anna Synak, Ignacy Gryczynski

    We measured the Förster resonance energy transfer (FRET) from Uranin (U) donor to Rhodamine 101 (R101) acceptor in propylene glycol. Steady-state fluorescence measurements show a significant difference between mixed and unmixed fluorophore solutions. In the solution with mixed fluorophores, fluorescence intensity of the U donor decreases and intensity of R101 fluorescence increases. This is visualized as a color change from green to orange. Fluorescence anisotropy of the mixture solution increases in the donor emission wavelength region and decreases in the acceptor emission wavelengths; which is consistent with FRET occurrence. Time-resolved (lifetime) measurements show a decrease of the U lifetime in the presence of R101 acceptor. In the intensity decay of R101 acceptor appears a negative component indicating excited state process. All these measurements prove the presence of FRET in U/R101 mixture fluorescence.


  • Open Access

    A triazine-based BODIPY trimer as a molecular viscometer

    by Sangram L. Raut, Joseph D. Kimball, Rafal Fudala, Ilkay Bora, Rahul Chib, Hana Jaafari, Marlius K. Castillo, Nicholas W. Smith, Ignacy Gryczynski, Sergei V. Dzyuba, et al.

    Photophysical behaviour of a novel trimeric BODIPY rotor with a high extinction coefficient is reported.