Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amin Fatoni has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of the moringa leaves extract on the tenderization of Longissimus muscle in Indonesian native goats

    by T. H. A. Mohamed, J. Sumarmono, A. Fatoni, T. Setyawardani, S. Rahayu, A. Setyaningrum, A. Frah

    M ea t ten d eriz a ti o n t e c h ni q u e s o ft en inv o lv e ti m e-c o nsu m ing pr o c e ss e s o r c hem ic a l add itiv e s t ha t ma y r a is e hea lt h c o nc er ns o r a lter t he t as t e o f mea t. Expl o r i ng a ltern a tiv e n a tur a l me t hod s, suc h as utilizing proteolytic enzymes derived from moringa, presents an opportunity to address these limitations. Studies on moringa have been limited, especially those focusing on goat meat tenderization, leaving a gap in understanding how moringa affects this process. The research aims to bridge this gap by systematically examining how protease enzymes from moringa leaves can tenderize goat meat. The research was performed on goat meat samples (100 g of meat per sample) treated with the moringa leaves extract (prepared from 20 g of moringa leaves with 60 ml of distilled water) at different storage times (2, 24, and 46 hours), as well as a control sample without any additive. The results showed that the moringa leaves extract did not significantly alter pH values and increased cooking loss for the 24-hour treatment (44.3 %) and 46-hour treatment (39.8 %) compared to the control (36.8 %). Color analysis showed increased lightness (L*) and redness (a*). The yellowness (b*) showed considerable difference between the control and the 24-hour samples compared with the 2-hour and 46-hour samples. The moringa leaves extract significantly reduced tenderness by lowering hardness, gumminess, resilience, and chewiness. This research advances environmentally friendly, renewable solutions in the food industry because the food industry produces significant quantities of meat by-products and waste during processing. This research will reduce waste by transforming tougher or less desirable meat cuts into more tender and valuable products.

  • Open Access

    Development of a Low-Cost Spectrophotometer for Protein Determination Using the Lowry Method

    by Lestha Aurel Salsabilla, Dadan Hermawan, Hartiwi Diastuti, Mekar Dwi Anggraeni, Amin Fatoni

    Affordable and accessible laboratory equipment is increasingly crucial, particularly in resource-limited settings. This research presents the development of a cost-effective spectrophotometer using an Arduino microcontroller and a TSL2591 light sensor to quantify protein concentration via the Lowry method. The device employs a 750 nm LED and a 3D-printed PLA case to house the components. Casein was used for calibration, yielding a linear detection range of 100–700 ppm with a high correlation coefficient (r = 0.9991). The limit of detection (LOD) and limit of quantification (LOQ) were 18.05 and 60.16 ppm, respectively. Precision was confirmed with a HORRAT value of 0.982. Accuracy was validated using the Wilcoxon Signed-Rank test, which showed no significant difference between the fabricated device and a commercial UV-vis spectrophotometer (p = 0.779). These findings support the reliability and reproducibility of the device for protein quantification. The project’s open-source nature encourages further development and application in educational, clinical, and field settings. This innovation supports the development of accessible, low-cost biochemical analysis tools.


  • Open Access

    Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent

    by Novia Rahmandani Shoobiroh, Dadan Hermawan, Hartiwi Diastuti, Mekar Dwi Anggraeni, Amin Fatoni

    Ensuring accessible and cost-effective laboratory equipment is essential for advancing scientific research in resource-limited settings. This study introduces a novel; low-cost spectrophotometer built with an Arduino microcontroller and a BH1750 light sensor to measure protein concentration using the Bradford method. The device features a 595 nm LED as the light source, encased in a 3D-printed PLA filament housing. Casein served as the standard protein for calibration and testing. The system demonstrated a linear detection range of 100 to 700 ppm, with a regression equation of y = 0.0007x + 0.1418 and a high correlation coefficient (R2 = 0.9921) compared to commercial spectrophotometers. The limit of detection and quantification were 58.43 and 194.77 ppm, respectively. Precision was confirmed with a HORRAT value of 0.161 using a 500 ppm sample, and accuracy was 103.34% for a 100 ppm sample. The device showed good selectivity against 200 ppm glucose interference. This open-source solution significantly reduces the cost of spectrophotometric analysis while improving accessibility in educational and remote laboratories. The practical implication of this study is it has strong potential for use in educational settings and field-based protein quantification due to its low cost, portability, and adequate performance.

  • Open Access

    Non-Invasive Wearable Sensor for Real-Time Neonatal Jaundice Monitoring Using Forehead Skin Tone Analysis

    by Amin Fatoni, Mekar Dwi Anggraeni, Eni Rahmawati

    Neonatal jaundice affects over 80% of newborns globally, posing significant health risks if untreated. Current diagnostic methods either lack accuracy or are prohibitively expensive, limiting accessibility in low-resource settings. This study presents a cost-effective, wearable device for non-invasive bilirubin monitoring based on forehead skin tone analysis. The device, comprising a TCS34725 color sensor and ESP32-C3 microcontroller, offers real-time bilirubin predictions validated against standard clinical methods. Calibration ensures reproducibility across devices, with recovery rates of 91–107%, meeting analytical validation standards. This innovation has the potential to revolutionize neonatal care by providing accessible, sustainable, and accurate monitoring, especially in underserved regions.


  • Open Access

    A Sustainable Approach to Glucose Biosensors: Utilizing Coconut Shell Activated Carbon and NiCaFeâ‚‚Oâ‚„ Nanoparticles

    by Amin Fatoni, David Hutama, Dadan Hermawan, Saluma Samanman, Mekar Dwi Anggraeni

    Diabetes-related mortality can be significantly reduced through early detection of blood glucose levels. This study presents a sustainable approach to glucose biosensors by utilizing coconut shell activated carbon as the working electrode material in a carbon paste electrode for electrochemical glucose detection via cyclic voltammetry. The performance of the electrode was further enhanced with NiCaFeâ‚‚ Oâ‚„ nanoparticles to improve electron transfer and redox potential. The optimized electrode consisted of a 2:1 ratio of activated carbon to paraffin, incorporating 16% NiCaFeâ‚‚ Oâ‚„ nanoparticles. Detection of hydrogen peroxide using this modified electrode exhibited an oxidation peak at 0.16 V and a reduction peak at -0.35 V. Optimal glucose detection conditions were achieved in 100 mM phosphate buffer at pH 7.5. Glucose oxidase was immobilized on the modified electrode, showing a linear response for glucose detection at the oxidation peak of 0.66 V. This sustainable biosensor demonstrated high sensitivity and potential for low- cost, eco-friendly glucose monitoring applications.


  • Open Access

    Molecular Docking Approach and Enantioseparation of Hydroxychloroquine by High-Performance Liquid Chromatography using Amylose Tris (3,5-dimethyl phenyl carbamate) as the Chiral Selector

    by Dadan Hermawan, Salsabil Rahmadina, Irmanto Irmanto, Amin Fatoni, Suwandri Suwandri, Mudasir Mudasir, Hassan Y Aboul-Enein

    The chiral separation of hydroxychloroquine, an antimalarial drug with one chiral center, has been predicted using molecular docking and was proven using the HPLC method. Docking utilized the PM3 semi-empirical method with specific grid coordinates (X = 19.977, Y = 20.069, and Z = 25.901) and a grid size of (X = 20, Y = 20, and Z = 60), employing a grid spacing of 1,000 Ã…, an exhaustiveness value of 8, and num_modes of 10. The analysis revealed the enhanced stability of R-hydroxychloroquine within the tris amylose complex, resulting in slower retention and elution rates compared to S-hydroxychloroquine. The HPLC experimental validation demonstrates resolution (Rs = 2.23), successfully achieved by employing amylose tris-based chiral columns. The mobile phase composition employed in this study consisted of acetonitrile:aquabidest: dimethylamine (47:52:1, v/v). Detection was performed at 343 nm, and the optimized HPLC method successfully quantitatively determined hydroxychloroquine in a liquid pharmaceutical sample with a percentage recovery of 98.47%.


  • Open Access

    Chitosan–Fe3O4 Nanoparticles Cryogel for Glucose Biosensor Development

    by Amin Fatoni, Vonia Febriana Hidayah, Suyata Suyata, Hartiwi Diastuti, Mekar Dwi Anggraeni

    Chitosan was widely used as a supporting material for enzyme immobilization. However, the non-conductive properties of chitosan could be a severe problem in the application of biosensors with electrochemical detection. This research aimed to modify the chitosan cryogel with Fe3O4 nanoparticles for glucose biosensor application. The glucose biosensor used glucose oxidase enzyme as biological sensing element which was immobilized on the working electrode of electrochemical detection. Chitosan-Fe3O4 composite cryogel was used as supporting material for glucose oxidase immobilization. The detection optimization was also performed by varying the operating conditions such as buffer pH and reaction temperature. The result showed the optimum conditions were the addition of Fe3O4 nanoparticles for 4% (w/v), phosphate buffer solution of 100 mM with pH of 7.0, and reaction temperature at 25°C. The glucose determination showed linearity for increasing oxidation peak and decreasing reduction peak with the glucose concentration, with regression equation of y = -6.804x – 104.32 and y = 4.5872x + 133.37 respectively. Furthermore, the limit of detection and limit of quantification for oxidation peaks were 0.38 mM and 1.25 mM respectively. The reduction peak showed a limit of detection of 0.32 mM and a limit of quantification of 1.07 mM.


  • Open Access

    Alginate NiFe2O4 Nanoparticles Cryogel for Electrochemical Glucose Biosensor Development

    by Amin Fatoni, Aziz Wijonarko, Mekar Dwi Anggraeni, Dadan Hermawan, Hartiwi Diastuti, Zusfahair

    Glucose biosensors based on porous material of alginate cryogel has been developed, and the cryogel provides a large surface area for enzyme immobilization. The alginate cryogel has been supplemented with NiFe2O4 nanoparticles to improve the electron transfer for electrochemical detection. The fabrication parameters and operational conditions for the biosensor have also been optimized. The results showed that the optimum addition of NiFe2O4 nanoparticles to the alginate solution was 0.03 g/mL. The optimum operational conditions for the electrochemical detection were a cyclic voltammetry scan rate of 0.11 V/s, buffer pH of 7.0, and buffer concentration of 150 mM. The fabricated alginate NiFe2O4 nanoparticles cryogel-based glucose biosensor showed a linear response for glucose determination with a regression line of y = 18.18x + 455.28 and R² = 0.98. Furthermore, the calculated detection limit was 0.32 mM and the limit of quantification was 1.06 mM.


  • Open Access

    Backmatter (Instruction for author and back cover)

    by Amin Fatoni

    Backmatter (Instruction for author and back cover)

  • Open Access

    Frontmatter (Front Cover, Editorial Team, Preface and Table of Contents)

    by Amin Fatoni

    Frontmatter (Front Cover, Editorial Team, Preface and Table of Contents)