JZJuan Luis Zamora-Macho

Juan Luis Zamora-Macho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juan Luis Zamora-Macho has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multi-Objective Optimisation for Robust Control of VSM-DFIG Wind Farms in Weak Grids

    by Javier García-Aguilar, Aurelio García-Cerrada, Juan Luis Zamora, Andrés Tomás-Martín

    The growing penetration of electricity generation interfaced through electronic converters often calls for grid-forming control strategies, such as the Virtual Synchronous Machine (VSM), to ensure grid stability, particularly in weak grids. Although coordinated frequency-domain design of converter controllers can achieve high performance at a designated operating point, a single-operating-point tuning does not guarantee robustness across the full operational envelope. This paper presents a systematic methodology for robust tuning of all control loops in doubly-fed induction generators with VSM capability (VSM-DFIG), which should facilitate the integration of wind energy into the electricity generation mix. The algorithm is applied to a benchmark four-machine DFIG wind farm, and significant improvements in controller performance are demonstrated using small-signal analysis and nonlinear time domain simulation. The proposed approach can be extended to other engineering systems with multiple control loops with mutual interactions. A multi-objective five-stage genetic algorithm optimises design specifications (phase margins, crossover frequencies, and virtual impedance values) across a wide range of grid strengths, power levels, and voltage conditions. The fitness evaluation relies entirely on linearised state-space models, and the effects of multiple perturbations are quantified using normalised time-weighted error metrics related to grid regulation and power tracking. The optimisation constraints enforce minimum damping in three frequency bands, and each solution candidate is evaluated at the extremes of the designated grid-strength range (short-circuit ratio (SCR) from 1 to 3) to guarantee robustness.

  • Delayed-Signal-Cancellation-Based Sag Detector for a Dynamic Voltage Restorer in Distorted Grids

    by Javier Roldan-Perez, Aurelio Garcia-Cerrada, Miguel Ochoa-Gimenez, Juan Luis Zamora-Macho

    Dynamic Voltage Restorers (DVRs) are a cost-effective solution to protect sensitive loads against voltage sags in medium- and high-power applications because the power required for the compensation is only a fraction of the load rated power. Voltage sag compensation with DVRs requires a robust sag detector that has to be able to address distorted-grid conditions. Also, sags should be detected fast in order to guarantee adequate protection of loads. In this paper, a sag detection algorithm for a DVR is proposed and comprehensively analysed. It is shown that this algorithm provides harmonic cancellation properties when the parameters are adequately tuned. Implementation aspects are addressed carefully and a method to adapt the algorithm when the grid frequency fluctuates is explained. The proposed algorithm was experimentally tested in a 5 kVA prototype of a DVR that protected a sensitive load (linear and non-linear) against voltage sags and voltage harmonics. The proposed algorithm was compared with three alternatives already proposed in the literature in terms of detection time, performance against voltage harmonics, and computational burden.


  • Open Access

    Comprehensive Design and Analysis of a State-Feedback Controller for a Dynamic Voltage Restorer

    by Javier Roldán-Pérez, Aurelio García-Cerrada, Alberto Rodríguez-Cabero, Juan Luis Zamora-Macho

    Voltage sags result in unwanted operation stops and large economical losses in industrial applications. A dynamic voltage restorer (DVR) is a power-electronics-based device conceived to protect high-power installations against these events. However, the design of a DVR control system is not straightforward and it has some peculiarities. First of all, a DVR includes a resonant (LC) connection filter with a lightly damped resonance. Secondly, the control system of a DVR should work properly regardless of the type of load, which can be linear or non-linear, to be protected. In this paper, a digital state-feedback (SF) controller for a DVR is proposed to address these issues. The design and features of the SF controller are studied in detail. Two pole-placement alternatives are discussed and the system robustness is tested under variations in the system parameters. Furthermore, implementation aspects such as discretization not commonly addressed in the literature are described. The controller is implemented in its incremental form. A decoupling system for the dq-axis dynamics that takes into account system delays and the load current is proposed and analytically studied. The proposed controller is compared with two other alternatives found in the literature: a Proportional-Integral-Differential (PID) controller and a cascade controller. The effect of the load connected downstream a DVR is also studied, revealing the potential of the SF controller to damp the resonance under light load conditions. All control system developments were tested in a 5 kVA prototype of a DVR connected to a configurable grid.


  • A steady-state harmonic controller for a series compensator with uncertain load dynamics

    by Javier Roldán-Pérez, Juan Luis Zamora-Macho, Miguel Ochoa-Giménez, Aurelio García-Cerrada


  • Open Access

    Comprehensive control for unified power quality conditioners

    by Miguel Ochoa-Giménez, Aurelio García-Cerrada, Juan Luis Zamora-Macho


  • A high-performance voltage sag detection algorithm for a Dynamic Voltage Restorer

    by Javier Roldan-Perez, Aurelio Garcia-Cerrada, Miguel Ochoa-Gimenez, Juan Luis Zamora-Macho

    Dynamic Voltage Restorers (DVRs) are a cost-effective solution to protect sensitive loads against voltage sags in medium- and high-power applications because the power required to compensate sags is only a fraction of the load rated power. Also, the energy storage requirements of DVRs can be greatly reduced by using minimum-power compensation of voltage sags. However, this compensation strategy can disturb sensitive loads and tends to saturate the injection transformer unless a slow phase rotation technique is used when a voltage sag is detected. The sag detection needs to be robust, but also fast to provide accurate results so that the DVR can work under all possible situations. This paper proposes and studies in detail a sag detection algorithm for a DVR that, when designed and implemented carefully, provides excellent performance when the grid voltage contains harmonics and the grid frequency varies. All the algorithms proposed in this paper are tested in a 5 kVA prototype of a DVR.


  • On the Power Flow Limits and Control in Series-Connected Custom Power Devices

    by Javier Roldan-Perez, Aurelio Garcia-Cerrada, Miguel Ochoa-Gimenez, Juan Luis Zamora-Macho

    Power electronic devices connected in series with electrical distribution lines have been proposed for some time to protect sensitive loads from voltage sags, voltage harmonics, and unbalances. Full understanding of active- and reactive-power consumption in the device is important in order to minimize losses and to provide reactive-power compensation while leaving the load undisturbed. However, a comprehensive description of power flow in series custom power devices has not been presented yet. This paper proposes a control framework where active and reactive power consumed by series devices can be analyzed and controlled. The method proposed is based on a reference frame synchronized with the load current, which greatly simplifies the power calculations and makes it possible to take into account the load-voltage constraints to guaranty safe operation of the load. The proposed method has been tested on a 5-kVA prototype of a series active conditioner.


  • Efficient multiple-reference-frame controller for harmonic suppression in custom power devices

    by Miguel Ochoa-Giménez, Javier Roldán-Peréz, Aurelio García-Cerrada, Juan Luis Zamora-Macho


  • Versatile Control of STATCOMs Using Multiple Reference Frames

    by Miguel Ochoa-Giménez, Aurelio García-Cerrada, Javier Roldán-Pérez, Juan L. Zamora-Macho, Pablo García-González, Emilo Bueno


  • Open Access

    Helping all generations of photo‐voltaic inverters ride‐through voltage sags

    by Javier Roldán‐Pérez, Aurelio García‐Cerrada, Juan Luis Zamora‐Macho, Miguel Ochoa‐Giménez

    The late Spanish grid code established that, to avoid island operation, renewable power sources have to be disconnected from the grid in the case of a voltage sag. This would threaten the system stability in case of massive penetration of renewable sources and motivated a recent revision of the code. The new code establishes strict ratios between active and reactive currents during the sag and requests that the plant must quickly resume its normal operation, when the voltage sag ends. Existing installations are also affected if they want to enjoy the premiums associated with renewable generation. When full upgrading of existing installations is not practical, this study proposes a plug‐in shunt‐connected power electronics device to help solar plants comply with the new grid code, without modifying the solar inverters. The device and its control algorithm are explained in this study and experimental results using photo‐voltaic inverters without low‐voltage ride‐through capability are presented. Solar inverters remain unaware of the voltage sag and they can be led quickly and smoothly back into the grid when the sag is over.