Michael J. Simpson
Research Subjects
Michael J. Simpson has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Damien Gatinel
Rothschild Foundation Hospital
1 shared publicationDavid L. Cooke
Great Lakes Eye Care
1 shared publicationG. R. Port
Dep. Chem., Univ. Wales, Bangor, UK
1 shared publication- Geunyoung Yoon
University of Houston
1 shared publication J. R. AL Dulayymi
Dep. Chem., Univ. Wales, Bangor, UK
1 shared publication- Jack T. Holladay
Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA
1 shared publication
Latest Publications
- 20 February 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 43 (3) , 524-534
Relating intraocular lens tilt to the optical axes of the eye
An average intraocular lens (IOL) tilt of approximately 5 deg relative to the visual axis is consistently reported in the clinical literature, with the implication that it represents a lens malposition. Modern biometry equipment also now routinely generates “chord” values related to tilt of the eye (chord alpha), and to centration of the pupil (chord mu), with other equipment measuring tilts directly. In this work, clinical data were used to create raytrace eye models, and these show that decentration of the foveal center from the optical axis causes a 5 deg rotation from the optical axis to the visual axis (angle α ), with similar values for both phakic and pseudophakic eyes, which explains the apparent lens tilt when viewing along the visual axis. Additional findings include that the iris is modestly decentered nasally from the optical axis, the cornea is typically measured along the keratometric axis but eye models are configured around the optical axis, and that lines drawn at 5 deg angles from the pupils meet at a distance corresponding to near vision. These findings clarify the geometric origin of commonly reported IOL tilt values and have important implications for clinical practice.
- 20 February 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 43 (3) , 524-534
Relating intraocular lens tilt to the optical axes of the eye
An average intraocular lens (IOL) tilt of approximately 5 deg relative to the visual axis is consistently reported in the clinical literature, with the implication that it represents a lens malposition. Modern biometry equipment also now routinely generates “chord” values related to tilt of the eye (chord alpha), and to centration of the pupil (chord mu), with other equipment measuring tilts directly. In this work, clinical data were used to create raytrace eye models, and these show that decentration of the foveal center from the optical axis causes a 5 deg rotation from the optical axis to the visual axis (angle α ), with similar values for both phakic and pseudophakic eyes, which explains the apparent lens tilt when viewing along the visual axis. Additional findings include that the iris is modestly decentered nasally from the optical axis, the cornea is typically measured along the keratometric axis but eye models are configured around the optical axis, and that lines drawn at 5 deg angles from the pupils meet at a distance corresponding to near vision. These findings clarify the geometric origin of commonly reported IOL tilt values and have important implications for clinical practice.
- 1 December 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (12) , 1156-1157
Comment on: Optical confirmation by a thick-lens formula of the optimized A-constant (as calculated by a thin-lens formula) of a new intraocular lens
- 1 December 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (12) , 1156-1157
Comment on: Optical confirmation by a thick-lens formula of the optimized A-constant (as calculated by a thin-lens formula) of a new intraocular lens
- 29 May 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (6) , 2495-2503
Vignetting and peripheral double images with intraocular lenses
Intraocular lenses (IOLs) are widely used, yet raytrace evaluations show that vignetting at very large angles limits the visual field of the focused image, though this is not specifically noticed by patients. A rare patient observation of peripheral double images in both eyes was modeled to demonstrate that a second image can be formed more peripherally by light missing the IOL, with simulated images illustrating the effect. Bothersome “dark shadows” that are reported by a small percentage of IOL patients, called negative dysphotopsia, have a similar cause, but are never reported as double images. The eyes had average dimensions, but the iris was thinner on the temporal side, with a nasally decentered pupil, and a distinct gap between the iris and the IOL, which all permit additional light to miss the IOL to create the second image.
- 29 May 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (6) , 2495-2503
Vignetting and peripheral double images with intraocular lenses
Intraocular lenses (IOLs) are widely used, yet raytrace evaluations show that vignetting at very large angles limits the visual field of the focused image, though this is not specifically noticed by patients. A rare patient observation of peripheral double images in both eyes was modeled to demonstrate that a second image can be formed more peripherally by light missing the IOL, with simulated images illustrating the effect. Bothersome “dark shadows” that are reported by a small percentage of IOL patients, called negative dysphotopsia, have a similar cause, but are never reported as double images. The eyes had average dimensions, but the iris was thinner on the temporal side, with a nasally decentered pupil, and a distinct gap between the iris and the IOL, which all permit additional light to miss the IOL to create the second image.
- 23 December 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (1) , 334-361
Design concepts for advanced-technology intraocular lenses [Invited]
An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, “advanced technology” IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.) and also to exploring increasing the depth of focus for monofocal IOLs using refractive methods, where although the defocus range might be more modest, visual phenomena are much less obvious. The designs cover a range of possibilities that might provide the best overall vision for patients with differing motivations, needs, and sensitivity to visual side effects.
- 23 December 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (1) , 334-361
Design concepts for advanced-technology intraocular lenses [Invited]
An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, “advanced technology” IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.) and also to exploring increasing the depth of focus for monofocal IOLs using refractive methods, where although the defocus range might be more modest, visual phenomena are much less obvious. The designs cover a range of possibilities that might provide the best overall vision for patients with differing motivations, needs, and sensitivity to visual side effects.
- 6 June 2023
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 40 (7) , D7-D13
Optical modeling of the entire visual field of the eye
Vision is rarely evaluated scientifically at very large visual angles, despite being used continuously in everyday life. Furthermore, raytrace calculations indicate that peripheral optical properties are different for a pseudophakic eye, and even though this is rarely noted by patients, it is probably the cause of bothersome “negative dysphotopsia.” Simplified paraxial parameters that characterize the basic properties of phakic and pseudophakic eyes are collected together here as a baseline, and then raytracing is used to show that input angles of about 60°, which correspond to obstruction by the nose, eyebrow, and cheek, illuminate a retinal hemisphere. At larger angles in the temporal direction, the image with an intraocular lens (IOL) reaches a limit due to vignetting at about a 90° input angle to the optical axis, in comparison to 105° with the Gullstrand–Emsley eye model, and 109° for the most realistic gradient index crystalline lens model. Scaling the far peripheral vision region more accurately may lead to benefits relating to intraocular lenses, diseases of the peripheral retina, widefield fundus images, and myopia prevention.
- 6 June 2023
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 40 (7) , D7-D13
Optical modeling of the entire visual field of the eye
Vision is rarely evaluated scientifically at very large visual angles, despite being used continuously in everyday life. Furthermore, raytrace calculations indicate that peripheral optical properties are different for a pseudophakic eye, and even though this is rarely noted by patients, it is probably the cause of bothersome “negative dysphotopsia.” Simplified paraxial parameters that characterize the basic properties of phakic and pseudophakic eyes are collected together here as a baseline, and then raytracing is used to show that input angles of about 60°, which correspond to obstruction by the nose, eyebrow, and cheek, illuminate a retinal hemisphere. At larger angles in the temporal direction, the image with an intraocular lens (IOL) reaches a limit due to vignetting at about a 90° input angle to the optical axis, in comparison to 105° with the Gullstrand–Emsley eye model, and 109° for the most realistic gradient index crystalline lens model. Scaling the far peripheral vision region more accurately may lead to benefits relating to intraocular lenses, diseases of the peripheral retina, widefield fundus images, and myopia prevention.
- 24 February 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (7) , 1853-1857
Focal length, EFL, and the eye
The focal length is often called the effective focal length, or efl instead, and although this is acceptable fora lens in air, it is not otherwise correct. The eye is used asan example here for an optical system where the object is in air and the image is in fluid. Welford,Aberrations of Optical Systems (1986) has paraxial equations that are consistent with historical use while also clearly defining efl. These are based on power at a surface having to be the same for light traveling in both directions (n'/f'). The focal length fis the actual physical distance from the 2nd principal point to the paraxial focus, and the equivalent focal length, or efl, is the focal length divided by the image index (f'/n'). Separately, when the object is in air, the efl is shown to act at the nodal point, with the lens system represented by either an equivalent thin lens at the principal point with a focal length or a different equivalent thin lens in air at the nodal point with an efl. The rationale for using effective instead of equivalent for efl is unclear, but efl is used more as a symbol than asan acronym. (c) 2023 Optica Publishing Group
- 24 February 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (7) , 1853-1857
Focal length, EFL, and the eye
The focal length is often called the effective focal length, or efl instead, and although this is acceptable fora lens in air, it is not otherwise correct. The eye is used asan example here for an optical system where the object is in air and the image is in fluid. Welford,Aberrations of Optical Systems (1986) has paraxial equations that are consistent with historical use while also clearly defining efl. These are based on power at a surface having to be the same for light traveling in both directions (n'/f'). The focal length fis the actual physical distance from the 2nd principal point to the paraxial focus, and the equivalent focal length, or efl, is the focal length divided by the image index (f'/n'). Separately, when the object is in air, the efl is shown to act at the nodal point, with the lens system represented by either an equivalent thin lens at the principal point with a focal length or a different equivalent thin lens in air at the nodal point with an efl. The rationale for using effective instead of equivalent for efl is unclear, but efl is used more as a symbol than asan acronym. (c) 2023 Optica Publishing Group
- Open Access
- 3 January 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (1) , 7
Letter to the Editor: Radial and Tangential Retinal Magnifications
- 3 January 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (1) , 7
Open AccessLetter to the Editor: Radial and Tangential Retinal Magnifications
- 28 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (10) , 2797-2804
Nodal points and the eye
Nodal points are defined using parallel object and image rays at very small angles to the optical axis, and Johann Listing described them when characterizing the eye in 1845. They are only distinct from principal points when there is a refractive index difference, but Reginald Clay used the term “nodal slide” in 1904 for equipment that uses lens rotation when measuring a lens focal length in air. Over time, sketches of nodal rays at large angles have become common, and these perhaps appear to support observations that input angles to the eye match image angles measured to the nodal point. Raytrace calculations confirm that this is correct for very large angles, but the relationship comes from the cornea curving around, towards incoming light, angles being rescaled at the exit pupil by a constant factor, and then the retina curving around to meet the image rays. The eye has high linearity, with 1:1 angular scaling occurring at approximately the nodal point, but ray bundles passing through the pupil center, rather than paraxial nodal rays, define the optical properties.
- 28 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (10) , 2797-2804
Nodal points and the eye
Nodal points are defined using parallel object and image rays at very small angles to the optical axis, and Johann Listing described them when characterizing the eye in 1845. They are only distinct from principal points when there is a refractive index difference, but Reginald Clay used the term “nodal slide” in 1904 for equipment that uses lens rotation when measuring a lens focal length in air. Over time, sketches of nodal rays at large angles have become common, and these perhaps appear to support observations that input angles to the eye match image angles measured to the nodal point. Raytrace calculations confirm that this is correct for very large angles, but the relationship comes from the cornea curving around, towards incoming light, angles being rescaled at the exit pupil by a constant factor, and then the retina curving around to meet the image rays. The eye has high linearity, with 1:1 angular scaling occurring at approximately the nodal point, but ray bundles passing through the pupil center, rather than paraxial nodal rays, define the optical properties.
- 21 September 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (1) , 95-99
Effect of a 7.0 mm intraocular lens optic on peripheral retinal illumination with implications for negative dysphotopsia
Purpose: To use optical modeling to compare a 6.0 mm and 7.0 mm intraocular lens (IOL) optic diameters on peripheral retinal illumination with implications for negative dysphotopsia. Setting: Mayo Clinic, Rochester, Minnesota, and Simpson Optics LLC, Arlington, Texas. Design: Model eye. Methods: Ray-tracing software was used to simulate retinal illumination from an extended light source for a pseudophakic eye with in-the-bag biconvex IOLs (refractive index [n] = 1.46 and 1.55) and a 2.5 mm pupil. Ray-tracing diagrams and simulated retina illumination profiles were compared using the 6.0 mm and 7.0 mm optic diameter IOLs. Retinal locations were scaled to relative visual angles from 70 to 110 degrees horizontally. Results: A 7.0 mm optic (n = 1.46) expands the image field by 2.8 degrees compared with a 6.0 mm optic. High-angle input light misses a 7.0 mm optic at a larger visual angle than a 6.0 mm optic, shifting illumination of the peripheral retina by this light anteriorly by 5.6 degrees. Consequently, a region of nonilluminated peripheral nasal retina is enlarged and shifted peripherally using a 7.0 mm optic (visual angle, 86.3 to 96.3 degrees) compared with a 6.0 mm optic (visual angle, 83.5 to 90.7 degrees). Similar illumination changes were seen modeling a 1.55 n IOL. Conclusions: A narrow dark region in the nasal retina when using a 6.0 mm optic is changed to a broader, more peripheral dark region when using a 7.0 mm optic. An extended, more peripheral dark nasal region may make a temporal shadow less bothersome and explain lower negative dysphotopsia rates using a 7.0 mm optic.
- 21 September 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (1) , 95-99
Effect of a 7.0 mm intraocular lens optic on peripheral retinal illumination with implications for negative dysphotopsia
Purpose: To use optical modeling to compare a 6.0 mm and 7.0 mm intraocular lens (IOL) optic diameters on peripheral retinal illumination with implications for negative dysphotopsia. Setting: Mayo Clinic, Rochester, Minnesota, and Simpson Optics LLC, Arlington, Texas. Design: Model eye. Methods: Ray-tracing software was used to simulate retinal illumination from an extended light source for a pseudophakic eye with in-the-bag biconvex IOLs (refractive index [n] = 1.46 and 1.55) and a 2.5 mm pupil. Ray-tracing diagrams and simulated retina illumination profiles were compared using the 6.0 mm and 7.0 mm optic diameter IOLs. Retinal locations were scaled to relative visual angles from 70 to 110 degrees horizontally. Results: A 7.0 mm optic (n = 1.46) expands the image field by 2.8 degrees compared with a 6.0 mm optic. High-angle input light misses a 7.0 mm optic at a larger visual angle than a 6.0 mm optic, shifting illumination of the peripheral retina by this light anteriorly by 5.6 degrees. Consequently, a region of nonilluminated peripheral nasal retina is enlarged and shifted peripherally using a 7.0 mm optic (visual angle, 86.3 to 96.3 degrees) compared with a 6.0 mm optic (visual angle, 83.5 to 90.7 degrees). Similar illumination changes were seen modeling a 1.55 n IOL. Conclusions: A narrow dark region in the nasal retina when using a 6.0 mm optic is changed to a broader, more peripheral dark region when using a 7.0 mm optic. An extended, more peripheral dark nasal region may make a temporal shadow less bothersome and explain lower negative dysphotopsia rates using a 7.0 mm optic.
- 17 September 2021
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 41 (6) , 1285-1291
Corneal power values for use with keratoprostheses and intraocular lenses
Purpose: To specify a keratoprosthesis (KPro) power value for use with an intraocular lens (IOL). Methods: Raytracing software was used to determine the imaging properties of both the natural cornea and conceptual KPro designs, and IOL power calculation methods were reviewed. Traditional calculations use ‘thick lens’ models for the overall eye, while also using ‘thin lens’ approximations for the cornea and IOL. The power of the natural cornea acts approximately at the apex, although this is unlikely to be the case for a KPro. The IOL location is determined using an empirical adjustment that is calculated from clinical results for natural eyes. Results: The use of a KPro has a similar optical effect to corneal refractive surgery, where the cornea no longer matches the original eye. A modification of the ‘double‐K’ calculation method can be used by specifying the KPro effective power at the original corneal apex, but still estimating the postoperative IOL location using the original corneal power. The KPro power is measured by assembling the KPro with fluid and a window to simulate the way it is used, recording the best focus power at room temperature with a 3 mm diameter aperture, rescaling to the in situ power at 35°C using refractive index changes, and then rescaling again to the power expected relative to the original corneal apex. When expressed as a K value, a keratometer refractive index of 1.332 is proposed. If necessary, clinical results may be used later to make empirical adjustments to the calculation method. Conclusions: A KPro power can be specified relative to the expected location of the original corneal apex using a keratometer index of 1.332. A double‐K calculation can then be used to determine the correct KPro and IOL power values for a pseudophakic eye.
- 17 September 2021
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 41 (6) , 1285-1291
Corneal power values for use with keratoprostheses and intraocular lenses
Purpose: To specify a keratoprosthesis (KPro) power value for use with an intraocular lens (IOL). Methods: Raytracing software was used to determine the imaging properties of both the natural cornea and conceptual KPro designs, and IOL power calculation methods were reviewed. Traditional calculations use ‘thick lens’ models for the overall eye, while also using ‘thin lens’ approximations for the cornea and IOL. The power of the natural cornea acts approximately at the apex, although this is unlikely to be the case for a KPro. The IOL location is determined using an empirical adjustment that is calculated from clinical results for natural eyes. Results: The use of a KPro has a similar optical effect to corneal refractive surgery, where the cornea no longer matches the original eye. A modification of the ‘double‐K’ calculation method can be used by specifying the KPro effective power at the original corneal apex, but still estimating the postoperative IOL location using the original corneal power. The KPro power is measured by assembling the KPro with fluid and a window to simulate the way it is used, recording the best focus power at room temperature with a 3 mm diameter aperture, rescaling to the in situ power at 35°C using refractive index changes, and then rescaling again to the power expected relative to the original corneal apex. When expressed as a K value, a keratometer refractive index of 1.332 is proposed. If necessary, clinical results may be used later to make empirical adjustments to the calculation method. Conclusions: A KPro power can be specified relative to the expected location of the original corneal apex using a keratometer index of 1.332. A double‐K calculation can then be used to determine the correct KPro and IOL power values for a pseudophakic eye.