Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiamiao Yang has a total of 120 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Continuous 3D microscopic measurement via spatial-resolution compensation

    by Yufan Qian, Yang Shen, Yian Huang, Jiale Zou, Lin Li, Rongjun Shao, Jiamiao Yang

    Extended-depth-of-field (EDOF) microscopy estimates surface height from axial focal positions, but elongation of the three-dimensional point-spread function makes axial resolution poorer than lateral resolution. We propose binocular oblique-view spatial-compensation microscopy (BOSCM), which uses two fixed, complementary oblique views to convert continuous lateral sample motion into simultaneous axial focal-plane scanning and lateral translation of the field of view. This geometry synchronizes focus-stack acquisition with large-area scanning and projects axial height variations onto the higher-resolution lateral direction. Global spatial calibration, constrained low-frequency residual compensation, and reliability-weighted fusion jointly recover dual-view height data and all-in-focus texture. Experiments show that BOSCM reduces spatial-resolution anisotropy, decreases the mean height RMSE by approximately 50%, improves the height-discrimination capability by approximately 18-fold, and improves reconstruction completeness on complex surfaces, enabling continuous large-area three-dimensional microscopic measurement.

  • Adaptive fringe density deflectometry measuring surfaces with large height fluctuation

    by Linxian Liu, Yian Huang, Yuan Qu, Zhe Dong, Zhilong Ye, Rongjun Shao, Jiamiao Yang

  • Robust 3D topography measurement of large-range high-aspect-ratio structures based on dual-domain statistical filtering in SD-OCT

    by Shenghao Chen, Xinzhe Li, Rongjun Shao, Yuejun Wu, Chengjun Duan, Lijun Zhou, Bosen Zhang, Jiamiao Yang

    Non-destructive topography measurement of high aspect ratio (HAR) microstructures (e.g., deep micro-holes) over a large dynamic range remains a major challenge in precision manufacturing. While spectral-domain optical coherence tomography (SD-OCT) offers a promising non-contact solution, its application is severely hindered by the complex background and noise inherent to HAR structures. To address this, this study proposes a dual-domain statistical filtering (DDSF) reconstruction method combined with a conventional longitudinal scanning (Z-scan) architecture. Utilizing the statistical features of interference signals, this method achieves the robust extraction of physical interfaces under extreme conditions through wavenumber-domain principal component analysis filtering and spatial-domain Bayesian filtering. DDSF successfully reconstructs the 3D topography of a highly reflective metal micro-hole with an aspect ratio exceeding 8:1, without complex hardware system modifications. Overall, DDSF effectively extends the geometric detection limits of traditional reflective SD-OCT and holds the potential to become a highly reliable, large dynamic range topography measurement tool for industrial HAR structures.

  • Unlimited field-of-view focus stacking microscopy based on tilted imaging

    by Yang Shen, Yian Huang, Yuan Qu, Jiamiao Yang

    Focus stacking microscopy achieves high-resolution, all-in-focus imaging through multi-focus image fusion and is widely applied in fields such as biology, materials science, and semiconductor inspection. However, for large-scale samples, conventional methods require pausing at each depth-of-field imaging position to capture a multi-focus image stack, which introduces mechanical backlash errors, reducing inspection efficiency and stitching accuracy, and thus fails to meet the requirements for all-in-focus, large field-of-view (FOV), and high-throughput inspection. Here, we propose an unlimited FOV focus stacking microscopy method based on tilted imaging (TI-FSM). By tilting the microscopy system, we decompose the sample's one-dimensional displacement into motion along and perpendicular to the optical axis, where the former is used to acquire a multi-focus image stack for all-in-focus scanning, while the latter enables unlimited FOV expansion. Additionally, we employ a joint texture–topography reconstruction algorithm to achieve simultaneous reconstruction of texture and 3D topography. Experimental results demonstrate that using a microscopy system with an NA of 0.28, TI-FSM achieves a vertical reconstruction accuracy of 16.2 μm. It enables unlimited FOV expansion and exhibits strong all-in-focus imaging and 3D topography measurement capabilities for large-scale, complex-structured surfaces.


  • Open Access

    Large dynamic range Shack-Hartmann wavefront sensing based on a graph-theoretic computational model

    by Lintong Du, Rui Xu, Shuxin Liu, Rongjun Shao, Lin Li, Yuhang Zhang, Ziqiang Li, Yuan Qu, Dapeng Tian, Jiamiao Yang

    The Shack-Hartmann wavefront sensor (SHWS) is a widely used non-interferometric wavefront measurement technique. However, for high-slope wavefronts, spot crosstalk and asymmetric distortion cause severe matching ambiguity and centroiding errors. This creates an inherent conflict between dynamic range and reconstruction accuracy. To address this, a graph-theoretic computational model named G-SHWS is proposed. By minimizing the global pairing cost of a bipartite graph constructed between fitted and actual spots, G-SHWS drives the fitted distribution to approximate the true distribution and maps the subaperture attribution of the fitted spots to the actual spots, achieving precise spot-subaperture matching under severe aliasing. Furthermore, incorporating a Graph Attention Network (GAT) embedded with SHWS matching topology, the model utilizes a graph structure to explicitly encode the matching relationships obtained from the matching process, and combines the spatial features and intensity morphology of spots to achieve high-precision reconstruction of strongly distorted wavefronts, effectively circumventing the inherent centroiding errors under large aberrations. Experimental results demonstrate that G-SHWS extends the measurable range of SHWS to 21 times the conventional limit while maintaining a reconstruction error of less than $$0.05{\rm{\lambda }}$$ 0.05 λ , and remains robust under severe spot loss. These advancements significantly enhance the SHWS’s ability to measure complex aberrations, providing a reliable computational framework for large dynamic range wavefront sensing.

  • Open Access

    基于混合视觉的金刚线布局智能检测方法

    by Sun Xiaolong, Li Lin, Li Ziqiang, Yang Jiamiao

    硅片切割工艺在太阳能电池制造等工业领域中具有关键地位,其中,金刚线线槽及线网布局的精确检测对硅片质量与切割精度至关重要。然而,传统人工检测方法存在效率低、一致性差的缺点,而纯深度学习方法在应对此类高密度、弱对比度的周期性结构时,常因特征混淆导致定位与分割精度不足。因此,提出了一种混合检测方法,该方法首先通过频域分析与曲线拟合构建线槽位置编码模型,实现线槽的微米级分割与定位,随后设计了一种轻量化网络DARMobileV2实现单一线槽图像的快速分类,最后结合位置编码信息重构出完整的线网布局情况。实验结果表明,在典型检测条件下,该方法在边缘计算设备上检测准确率不低于99.6%,检测时间低于1 s,相较传统的人工检测方法,错检率降低97.74%,速度提升52.4倍,为硅片精密切割工艺提供了一种高效、可靠的自动化检测解决方案。

  • Genetic-algorithm-based nonlinear calibration method for the digital micromirror device

    by Jingyu Tan, Shenghao Chen, Chunxu Ding, Lin Li, Jiamiao Yang

    As an important modulation device for optical imaging, precision detection, and high-end display, the nonlinear error of the digital micromirror device (DMD) has become a key performance-limiting factor. Traditional calibration methods rely on simplified models, struggle to characterize full-range nonlinearity, and cannot directly optimize the key parameter, like micromirror flipping time. To address these challenges, this paper proposes a genetic algorithm (GA)-based nonlinear calibration method. By using a photodetector (PD) for real-time light intensity feedback and GA to optimize the flipping time, high-precision calibration is achieved. Simulations and experiments demonstrate global optimization and uniform modulation, with DMD linearity improved by 42.2% post-calibration. Optimal parameters show strong adaptability across frame rates, enhancing optimization efficiency. Notably, the method remains effective under hardware-limited high frame rates, expanding the working range and applicability.

  • A fast optical design method for the objective under Köhler illumination to reduce ghost images

    by Yang Shen, Bowen Liu, Yuan Qu, Peng Miao, Yan Shi, Rongjun Shao, Jiamiao Yang

    In high-precision microscopy, the Köhler illumination is often used to ensure clear surface details. However, it can introduce artifacts, such as ghost images, which must be effectively controlled. Here, we propose a matrix optics method (MOM) to estimate the ghost images formed in the microscope objective under the Köhler illumination. On the basis of MOM, we develop a function for the evaluation of image quality and ghost image intensity. Using this function, we can optimize the objective to mitigate the ghost images and preserve a good image quality simultaneously. The research results show that our method can reduce the intensity of ghost image by 60.6% as well as the time consumption from 158 s to 3 s for each iteration. This method can be potentially useful for the optical design of microscope objectives.