Raymond Yee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Raymond Yee has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
- George J. Klein
Division of Cardiology, Department of Medicine, University of Western Ontario, London, Ontario, Canada
8 shared publications - Andrew D. Krahn
Division of Cardiology, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
5 shared publications Francois Philippon
Division de Cardiologie, Departement de Medicine, Universite Laval, Ville de Quebec, Quebec, Canada
5 shared publications- Allan C. Skanes
Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Western University, London, ON, Canada (A.C.S., P.L.-S., H.R.K., J.D.R.).
4 shared publications - Jaimie Manlucu
University of Western Ontario
4 shared publications Bernard Thibault
Division of Cardiology, Montreal Heart Institute, Montreal, Québec, Canada
3 shared publications
Latest Publications
- Open Access
- 5 January 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (4) , e583-e594
Real-world performance of intrinsic antitachycardia pacing: Primary results from a global prospective postapproval registry study
- 5 January 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (4) , e583-e594
Open AccessReal-world performance of intrinsic antitachycardia pacing: Primary results from a global prospective postapproval registry study
- Open Access
- 1 November 2021
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 37 (11) , 1857-1860
Canadian Heart Rhythm Society Task Force Report on Physician Training and Maintenance of Competency for Cardiovascular Implantable Electronic Device Therapies: Executive Summary
- 1 November 2021
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 37 (11) , 1857-1860
Open AccessCanadian Heart Rhythm Society Task Force Report on Physician Training and Maintenance of Competency for Cardiovascular Implantable Electronic Device Therapies: Executive Summary
- Open Access
- 28 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytab096
A case report of inappropriate inhibition of ventricular pacing due to a unique pacemaker electrogram storage feature
Background: Modern permanent pacemakers (PPMs) have individual features designed to identify cardiac rhythm abnormalities and improve their performance. Inappropriate pacing inhibition may be an undesired outcome from these features and cause symptoms in patients who require frequent pacing, leading to dizziness, and syncope. Inappropriate inhibition can be difficult to identify in circumstances that are intermittent and difficult to reproduce. Case summary: A 57-year-old female underwent a mitral valve replacement (MVR) for severe mitral stenosis. One month following MVR, she presented with symptomatic third-degree atrioventricular block, and a dual-chamber PPM (Advisa™, Medtronic, Minneapolis, USA) was implanted and programmed DDD 50–130 b.p.m. At the 3-month follow-up, she reported frequent episodes of lightheadedness. She was found to have intermittent ventricular pacing inhibition on a 48-h Holter monitor due to an internal function of the Advisa™ series of PPMs that attempts to store an electrogram (EGM) every 1 h and 30 s. During the EGM storage, an amplified signal from the storage capacitor can result in oversensing by the ventricular channel and inappropriate pacing inhibition. Discussion: To rectify the issue, the ventricular lead sensitivity value was increased from 0.9 mV to 1.2 mV. No instances of inappropriate ventricular pacing inhibition were noted on follow-up. To our knowledge, this is a rare case of inappropriate ventricular pacing inhibition caused by a combination of PPM self-adjusting sensitivity algorithm and oversensing every 1 h and 30 s from an amplified storage capacitor. Physicians should be aware of this possible complication and differentiate it from device or lead malfunction.
- 28 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytab096
Open AccessA case report of inappropriate inhibition of ventricular pacing due to a unique pacemaker electrogram storage feature
Background: Modern permanent pacemakers (PPMs) have individual features designed to identify cardiac rhythm abnormalities and improve their performance. Inappropriate pacing inhibition may be an undesired outcome from these features and cause symptoms in patients who require frequent pacing, leading to dizziness, and syncope. Inappropriate inhibition can be difficult to identify in circumstances that are intermittent and difficult to reproduce. Case summary: A 57-year-old female underwent a mitral valve replacement (MVR) for severe mitral stenosis. One month following MVR, she presented with symptomatic third-degree atrioventricular block, and a dual-chamber PPM (Advisa™, Medtronic, Minneapolis, USA) was implanted and programmed DDD 50–130 b.p.m. At the 3-month follow-up, she reported frequent episodes of lightheadedness. She was found to have intermittent ventricular pacing inhibition on a 48-h Holter monitor due to an internal function of the Advisa™ series of PPMs that attempts to store an electrogram (EGM) every 1 h and 30 s. During the EGM storage, an amplified signal from the storage capacitor can result in oversensing by the ventricular channel and inappropriate pacing inhibition. Discussion: To rectify the issue, the ventricular lead sensitivity value was increased from 0.9 mV to 1.2 mV. No instances of inappropriate ventricular pacing inhibition were noted on follow-up. To our knowledge, this is a rare case of inappropriate ventricular pacing inhibition caused by a combination of PPM self-adjusting sensitivity algorithm and oversensing every 1 h and 30 s from an amplified storage capacitor. Physicians should be aware of this possible complication and differentiate it from device or lead malfunction.
- 16 September 2020
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (12) , 3207-3214
A simple maneuver to determine if septal accessory pathway ablation requires a left atrial approach
Introduction: Septal accessory pathway (AP) ablation can be challenging due to the complex anatomy of the septal region. The decision to access the left atrium (LA) is often made after failure of ablation from the right. We sought to establish whether the difference between ventriculo‐atrial (VA) time during right ventricular (RV) apical pacing versus the VA during tachycardia would help establish the successful site for ablation of septal APs.Methods: Intracardiac electrograms of patients with orthodromic reciprocating tachycardia (ORT) using a septal AP with successful catheter ablation were reviewed. The ∆VA was the difference between the VA interval during RV apical pacing and the VA interval during ORT. The difference in the VA interval during right ventricular entrainment and ORT (StimA–VA) was also measured.Results: The median ∆VA time was significantly less in patients with a septal AP ablated on the right side compared with patients with a septal AP ablated on the left side (12 ± 19 vs. 56 ± 10 ms, p < .001). The StimA–VA was significantly different between the two groups (22 ± 14 vs. 53 ± 9 ms, p < .001). The ∆VA and StimA–VA were always 40 ms in patients with non‐decremental septal APs ablated from the right side and always greater than 40 ms in those with septal APs ablated from the left.Conclusion: ΔVA and StimA–VA values identified with RV apical pacing in the setting of ORT involving a septal AP predict when left atrial access will be necessary for successful ablation.
- 16 September 2020
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (12) , 3207-3214
A simple maneuver to determine if septal accessory pathway ablation requires a left atrial approach
Introduction: Septal accessory pathway (AP) ablation can be challenging due to the complex anatomy of the septal region. The decision to access the left atrium (LA) is often made after failure of ablation from the right. We sought to establish whether the difference between ventriculo‐atrial (VA) time during right ventricular (RV) apical pacing versus the VA during tachycardia would help establish the successful site for ablation of septal APs.Methods: Intracardiac electrograms of patients with orthodromic reciprocating tachycardia (ORT) using a septal AP with successful catheter ablation were reviewed. The ∆VA was the difference between the VA interval during RV apical pacing and the VA interval during ORT. The difference in the VA interval during right ventricular entrainment and ORT (StimA–VA) was also measured.Results: The median ∆VA time was significantly less in patients with a septal AP ablated on the right side compared with patients with a septal AP ablated on the left side (12 ± 19 vs. 56 ± 10 ms, p < .001). The StimA–VA was significantly different between the two groups (22 ± 14 vs. 53 ± 9 ms, p < .001). The ∆VA and StimA–VA were always 40 ms in patients with non‐decremental septal APs ablated from the right side and always greater than 40 ms in those with septal APs ablated from the left.Conclusion: ΔVA and StimA–VA values identified with RV apical pacing in the setting of ORT involving a septal AP predict when left atrial access will be necessary for successful ablation.
- 1 March 2018
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 10 (1)
Contemporary Review of the Cardiovascular Implantable Electronic Devices with Future Directions
- 1 March 2018
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 10 (1)
Contemporary Review of the Cardiovascular Implantable Electronic Devices with Future Directions
- 1 March 2018
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 10 (1)
Contemporary Issues in Patients with Implantable Devices
- 1 March 2018
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 10 (1)
Contemporary Issues in Patients with Implantable Devices
- 1 March 2018
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 10 (1) , 119-125
Implantable Cardioverter Defibrillator Implantation with or Without Defibrillation Testing
- 1 March 2018
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 10 (1) , 119-125
Implantable Cardioverter Defibrillator Implantation with or Without Defibrillation Testing
- 1 September 2017
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 10 (9)
Initial Clinical Experience With a New Automated Antitachycardia Pacing Algorithm
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD) decreases patient shock burden but has recognized limitations. A new automated ATP (AATP) based on electrophysiological first principles was designed. The study objective was to assess the feasibility and safety of AATP in ambulatory ICD patients. Methods and Results: Enrolled patients had dual chamber or cardiac resynchronization therapy ICDs, history of ≥1 ICD-treated ventricular tachycardias (VT)/ventricular fibrillation episode, or a recorded, sustained monomorphic VT. Detection was set to ventricular fibrillation number of intervals to detect=24/32, VT number of intervals to detect≥16, and a fast VT zone of 240 to 320 ms. AATP prescribed the components and delivery of successive ATP sequences in real time, using the same settings for all patients. ICD datalogs were uploaded every ≈3 months, at unscheduled visits, exit, and death. Episodes and adverse events were adjudicated by separate committees. Results were adjusted (generalized estimating equations) for multiple episodes. AATP was downloaded into the ICDs of 144 patients (121 men), aged 67.4±11.9 years, left ventricular ejection fraction 33.1±13.6% (n=137), and treated 1626 episodes in 49 patients during 14.5±5.1 months of follow-up. Datalogs permitted adjudication of 702 episodes, including 669 sustained monomorphic VT, 20 polymorphic VT, 10 supraventricular tachycardia, and 3 malsensing episodes. AATP terminated 39 of 69 (59% adjusted) sustained monomorphic VT in the fast VT zone, 509 of 590 (85% adjusted) in the VT zone, and 6 of 10 in the ventricular fibrillation zone. No supraventricular tachycardias converted to VT or ventricular fibrillation. No anomalous AATP behavior was observed. Conclusions: The new AATP algorithm safely generated ATP sequences and controlled therapy progression in all zones without need for individualized programing.
- 1 September 2017
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 10 (9)
Initial Clinical Experience With a New Automated Antitachycardia Pacing Algorithm
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD) decreases patient shock burden but has recognized limitations. A new automated ATP (AATP) based on electrophysiological first principles was designed. The study objective was to assess the feasibility and safety of AATP in ambulatory ICD patients. Methods and Results: Enrolled patients had dual chamber or cardiac resynchronization therapy ICDs, history of ≥1 ICD-treated ventricular tachycardias (VT)/ventricular fibrillation episode, or a recorded, sustained monomorphic VT. Detection was set to ventricular fibrillation number of intervals to detect=24/32, VT number of intervals to detect≥16, and a fast VT zone of 240 to 320 ms. AATP prescribed the components and delivery of successive ATP sequences in real time, using the same settings for all patients. ICD datalogs were uploaded every ≈3 months, at unscheduled visits, exit, and death. Episodes and adverse events were adjudicated by separate committees. Results were adjusted (generalized estimating equations) for multiple episodes. AATP was downloaded into the ICDs of 144 patients (121 men), aged 67.4±11.9 years, left ventricular ejection fraction 33.1±13.6% (n=137), and treated 1626 episodes in 49 patients during 14.5±5.1 months of follow-up. Datalogs permitted adjudication of 702 episodes, including 669 sustained monomorphic VT, 20 polymorphic VT, 10 supraventricular tachycardia, and 3 malsensing episodes. AATP terminated 39 of 69 (59% adjusted) sustained monomorphic VT in the fast VT zone, 509 of 590 (85% adjusted) in the VT zone, and 6 of 10 in the ventricular fibrillation zone. No supraventricular tachycardias converted to VT or ventricular fibrillation. No anomalous AATP behavior was observed. Conclusions: The new AATP algorithm safely generated ATP sequences and controlled therapy progression in all zones without need for individualized programing.
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 82-13
Objective criteria for septal fibrosis in non-ischemic dilated cardiomyopathy: validation for the prediction of future cardiovascular events
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 82-13
Open AccessObjective criteria for septal fibrosis in non-ischemic dilated cardiomyopathy: validation for the prediction of future cardiovascular events